Platinum-Iridium alloy films were prepared by MOCVD on Mo substrate using metal-acetylacetonate precursors. Effects of deposition conditions on composition, microstructure and mechanical properties were determined. In...Platinum-Iridium alloy films were prepared by MOCVD on Mo substrate using metal-acetylacetonate precursors. Effects of deposition conditions on composition, microstructure and mechanical properties were determined. In these experimental conditions, the purities of films are high and more than 99.0%. The films are homogeneous and monophase solid solution of Pt and Ir. Weight percentage of platinum are much higher than iridium in the alloy. Lattice constant of the alloy changes with the platinum composition. Iridium composition showing an up-down-up trend at the precursor temperature of 190~230℃ and the deposition temperature at 400~ 550℃. The hardness of Pt-Ir alloys prepared by MOCVD is three times more than the alloys prepared by casting.展开更多
Platinum, palladium and their alloy films on polyimide were formed by catalyst-enhanced chemical vapor deposition (CVD) in the carrier gas (N2, O2) at 220-300℃ under reduced pressure and normal pressure. The depo...Platinum, palladium and their alloy films on polyimide were formed by catalyst-enhanced chemical vapor deposition (CVD) in the carrier gas (N2, O2) at 220-300℃ under reduced pressure and normal pressure. The deposition of palladium complexes [ Pd((η3-allyl)(hfac) and Pd(hfac)2 ] gives pure palladium film, while the deposition of platinum needs the enhancement of palladium complex by mixing precursor platinum complex Pt(COD)Me2 and palladium complex in the same chamber. The co-deposition of Pd and Pt metals was used for the deposition of alloy films. During the CVD of palladium-platinum alloy, the Pd/Pt atomic ratios vary under different co-deposition conditions. These metal films were characterized by XPS and SEM, and show a good adhesive property.展开更多
To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is wel...To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.展开更多
基金supported by National Natural Science Foundation of China(Grant No.50771051)the Natural Science Foundation of Yunnan,China(Program No2003PY10and No2011FZ220)
文摘Platinum-Iridium alloy films were prepared by MOCVD on Mo substrate using metal-acetylacetonate precursors. Effects of deposition conditions on composition, microstructure and mechanical properties were determined. In these experimental conditions, the purities of films are high and more than 99.0%. The films are homogeneous and monophase solid solution of Pt and Ir. Weight percentage of platinum are much higher than iridium in the alloy. Lattice constant of the alloy changes with the platinum composition. Iridium composition showing an up-down-up trend at the precursor temperature of 190~230℃ and the deposition temperature at 400~ 550℃. The hardness of Pt-Ir alloys prepared by MOCVD is three times more than the alloys prepared by casting.
基金Funded by the National Natural Science Foundation of China (Nos. 20275011 and 20675033)
文摘Platinum, palladium and their alloy films on polyimide were formed by catalyst-enhanced chemical vapor deposition (CVD) in the carrier gas (N2, O2) at 220-300℃ under reduced pressure and normal pressure. The deposition of palladium complexes [ Pd((η3-allyl)(hfac) and Pd(hfac)2 ] gives pure palladium film, while the deposition of platinum needs the enhancement of palladium complex by mixing precursor platinum complex Pt(COD)Me2 and palladium complex in the same chamber. The co-deposition of Pd and Pt metals was used for the deposition of alloy films. During the CVD of palladium-platinum alloy, the Pd/Pt atomic ratios vary under different co-deposition conditions. These metal films were characterized by XPS and SEM, and show a good adhesive property.
基金The National Natural Science Foundation of China(No.50878125)
文摘To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.