The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(S...The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(SSRT) technique combined with optical microscopy(OM), scanning electron microscopy(SEM) and transmission electron microscopy(TEM). The results show that the through-thickness corrosion resistance is ranked in the order of T/2>surface>T/4. And the 75 mm-thick 7050 alloy plate presents better corrosion resistance than the 35 mm-thick plate. The results are discussed in terms of the combined effect of recrystallization and cooling rate in quenching. Alloy with lower volume fraction of recrystallization and smaller grain aspect ratio displays better corrosion resistance. The lower corrosion resistance caused by the slower cooling rate results from the higher coverage rate of grain boundary precipitates and larger width of precipitate free zone.展开更多
The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron micros...The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM). The results show that the cathodic diffusion current density presents the variation trend of initial increase and subsequent decrease with the decrease of TEL thickness, and the maximum deposits at 58 μm. The cotangent-hyperbolic impedance(O) is rationally first introduced to study the diffusion process of the reactants through the corrosion products layer with many permeable holes. The initial corrosion rate of 907 steel under different TEL thickness increases with the decrease of TEL thickness except that of 104 μm,whereas the corrosion rate after long time corrosion can be ranked as 104 μm﹥402 μm﹥198 μm﹥301 μm﹥bulk solution.展开更多
The microstructure and corrosion resistance of dissimilar weld-joints between stainless steel SAF 2205 and stainless steel AISI 316L were investigated. Welding was accomplished by different types of welding wires AWS ...The microstructure and corrosion resistance of dissimilar weld-joints between stainless steel SAF 2205 and stainless steel AISI 316L were investigated. Welding was accomplished by different types of welding wires AWS ER 347, AWS ER 316L and AWS ER 309L. To verify soundness of welded samples, nondestructive tests were performed. Metallographic samples were prepared from cross-section areas of weld- joints to investigate microstructure of different regions of weld-joints by optical microscopy and scanning electron microscopy. Corrosion resistance of weld-joints was evaluated in NaCI solution by potentiodynamic polarization and electrochemical impedance techniques. In the weld metal AWS ER 347, the brittle sigma phase was created, resulting in the decrease of weld-joint corrosion resistance. According to the results of metallurgical investigations and corrosion tests, welding wire AWS ER 309L was suitable for welding duplex stainless steel (SAF 2205) to austenitic stainless steel (AIS1316L) by gas tungsten arc welding (GTAW) process.展开更多
In this study,ceramic coatings were deposited on 6061 Al alloy using a plasma electrolytic oxidation(PEO)technique,and the effect of concentrations of KOH and Na_2SiO_3 as electrolytes for PEO process was studied on...In this study,ceramic coatings were deposited on 6061 Al alloy using a plasma electrolytic oxidation(PEO)technique,and the effect of concentrations of KOH and Na_2SiO_3 as electrolytes for PEO process was studied on microstructure,chemical composition,and electrochemical behavior of PEO coatings formed on the 6061 Al alloy.The results indicated that the increase in concentration of KOH led to rise in electrical conductivity of electrolyte.Consequently,the breakdown voltage reduced,which in turn improved the surface quality and the corrosion behavior.Moreover,the increase in concentration of Na_2SiO_3 resulted in the increase in incorporation of Si in the coating,which led to a higher corrosion potential in the concentration of 4 g L^(-1).According to this investigation,the best protection behavior of coatings can be obtained when the KOH and Na_2SiO_3 concentrations in PEO electrolyte are equal to 4 g L^(-1).展开更多
Corrosion evolution during immersion tests (up to 43 days) of NiCu steel in deaerated 0.1 mol/L bicarbonate solutions was investigated by electrochemical measurements, scanning electron microscopy (SEM) and X-ray ...Corrosion evolution during immersion tests (up to 43 days) of NiCu steel in deaerated 0.1 mol/L bicarbonate solutions was investigated by electrochemical measurements, scanning electron microscopy (SEM) and X-ray diffraction (XRD). Results show that NiCu steel transformed from the anodic dissolution in the early stage of immersion to a metastable passive state in the final stage as the open-circuit potential value shifted positively, which was aroused by the precipitation of corrosion products. This process was mainly promoted by the trace amount of oxygen. Simultaneously, dominant cathodic reaction transformed from the hydrogen evolution in early stage to reduction processes of corrosion products in later stages. Possible corrosion processes were discussed with the assistance of a corresponding Pourbaix diagram.展开更多
The effect of solution pH,Cl;concentration and temperature on the electrochemical corrosion behavior of PH13-8Mo steel in acidic solution was investigated by using the electrochemical tests,scanning electron microscop...The effect of solution pH,Cl;concentration and temperature on the electrochemical corrosion behavior of PH13-8Mo steel in acidic solution was investigated by using the electrochemical tests,scanning electron microscopy and X-ray photoelectron spectroscopy.The PH13-8Mo martensitic precipitation hardened stainless steel is in the passivity state when the pH value is above 3.0,below which the anodic polarization curves of the steel are actively dissolved.The corrosion current density gradually decreases with increasing the solution pH and decreasing Cl;concentration and solution temperature.Pits are initiated on the sample surface in the presence of the Cl;and gradually developed into uniform corrosion with increasing the Cl;concentrations.Moreover,the corrosion is more serious with an increase in solution temperature.展开更多
基金Project(2012CB619503)supported by the National Basic Research Program of ChinaProject(2013AH100055)supported by the Foshan Civic Technological Innovation Foundation,China
文摘The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(SSRT) technique combined with optical microscopy(OM), scanning electron microscopy(SEM) and transmission electron microscopy(TEM). The results show that the through-thickness corrosion resistance is ranked in the order of T/2>surface>T/4. And the 75 mm-thick 7050 alloy plate presents better corrosion resistance than the 35 mm-thick plate. The results are discussed in terms of the combined effect of recrystallization and cooling rate in quenching. Alloy with lower volume fraction of recrystallization and smaller grain aspect ratio displays better corrosion resistance. The lower corrosion resistance caused by the slower cooling rate results from the higher coverage rate of grain boundary precipitates and larger width of precipitate free zone.
基金Projects(21073162,21273199) supported by the National Natural Science Foundation of ChinaProject(GCTKF2012013) supported by the Science and Technology Bureau of Jiaxing Municipality and the State Key Laboratory Breeding Base of Green Chemistry-Synthesis Technology,China
文摘The corrosion behavior of 907 steel under thin electrolyte layer(TEL) has been investigated by means of cathodic polarization curve measurement, electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM). The results show that the cathodic diffusion current density presents the variation trend of initial increase and subsequent decrease with the decrease of TEL thickness, and the maximum deposits at 58 μm. The cotangent-hyperbolic impedance(O) is rationally first introduced to study the diffusion process of the reactants through the corrosion products layer with many permeable holes. The initial corrosion rate of 907 steel under different TEL thickness increases with the decrease of TEL thickness except that of 104 μm,whereas the corrosion rate after long time corrosion can be ranked as 104 μm﹥402 μm﹥198 μm﹥301 μm﹥bulk solution.
文摘The microstructure and corrosion resistance of dissimilar weld-joints between stainless steel SAF 2205 and stainless steel AISI 316L were investigated. Welding was accomplished by different types of welding wires AWS ER 347, AWS ER 316L and AWS ER 309L. To verify soundness of welded samples, nondestructive tests were performed. Metallographic samples were prepared from cross-section areas of weld- joints to investigate microstructure of different regions of weld-joints by optical microscopy and scanning electron microscopy. Corrosion resistance of weld-joints was evaluated in NaCI solution by potentiodynamic polarization and electrochemical impedance techniques. In the weld metal AWS ER 347, the brittle sigma phase was created, resulting in the decrease of weld-joint corrosion resistance. According to the results of metallurgical investigations and corrosion tests, welding wire AWS ER 309L was suitable for welding duplex stainless steel (SAF 2205) to austenitic stainless steel (AIS1316L) by gas tungsten arc welding (GTAW) process.
文摘In this study,ceramic coatings were deposited on 6061 Al alloy using a plasma electrolytic oxidation(PEO)technique,and the effect of concentrations of KOH and Na_2SiO_3 as electrolytes for PEO process was studied on microstructure,chemical composition,and electrochemical behavior of PEO coatings formed on the 6061 Al alloy.The results indicated that the increase in concentration of KOH led to rise in electrical conductivity of electrolyte.Consequently,the breakdown voltage reduced,which in turn improved the surface quality and the corrosion behavior.Moreover,the increase in concentration of Na_2SiO_3 resulted in the increase in incorporation of Si in the coating,which led to a higher corrosion potential in the concentration of 4 g L^(-1).According to this investigation,the best protection behavior of coatings can be obtained when the KOH and Na_2SiO_3 concentrations in PEO electrolyte are equal to 4 g L^(-1).
基金supported by the National Natural Science Foundation of China (No. 51471175)
文摘Corrosion evolution during immersion tests (up to 43 days) of NiCu steel in deaerated 0.1 mol/L bicarbonate solutions was investigated by electrochemical measurements, scanning electron microscopy (SEM) and X-ray diffraction (XRD). Results show that NiCu steel transformed from the anodic dissolution in the early stage of immersion to a metastable passive state in the final stage as the open-circuit potential value shifted positively, which was aroused by the precipitation of corrosion products. This process was mainly promoted by the trace amount of oxygen. Simultaneously, dominant cathodic reaction transformed from the hydrogen evolution in early stage to reduction processes of corrosion products in later stages. Possible corrosion processes were discussed with the assistance of a corresponding Pourbaix diagram.
基金financially sponsored by the National Basic Research Program of China(2014CB643306)
文摘The effect of solution pH,Cl;concentration and temperature on the electrochemical corrosion behavior of PH13-8Mo steel in acidic solution was investigated by using the electrochemical tests,scanning electron microscopy and X-ray photoelectron spectroscopy.The PH13-8Mo martensitic precipitation hardened stainless steel is in the passivity state when the pH value is above 3.0,below which the anodic polarization curves of the steel are actively dissolved.The corrosion current density gradually decreases with increasing the solution pH and decreasing Cl;concentration and solution temperature.Pits are initiated on the sample surface in the presence of the Cl;and gradually developed into uniform corrosion with increasing the Cl;concentrations.Moreover,the corrosion is more serious with an increase in solution temperature.