期刊文献+
共找到69,945篇文章
< 1 2 250 >
每页显示 20 50 100
Is there utility for fluorine-18-fluorodeoxyglucose positron-emission tomography scan before surgery in breast cancer? A 15-year overall survival analysis
1
作者 Justine Perrin Karim Farid +6 位作者 Hilde Van Parijs Olena Gorobets Vincent Vinh-Hung Nam P Nguyen Navid Djassemi Mark De Ridder Hendrik Everaert 《World Journal of Clinical Oncology》 CAS 2022年第4期287-302,共16页
BACKGROUND The prognostic value of preoperative fluorine-18-fluorodeoxyglucose positronemission tomography(18 F-FDG PET)scan for determining overall survival(OS)in breast cancer(BC)patients is controversial.AIM To eva... BACKGROUND The prognostic value of preoperative fluorine-18-fluorodeoxyglucose positronemission tomography(18 F-FDG PET)scan for determining overall survival(OS)in breast cancer(BC)patients is controversial.AIM To evaluate the OS predictive value of preoperative PET positivity after 15 years.METHODS We performed a retrospective search of the Universitair Ziekenhuis Brussel patient database for nonmetastatic patients who underwent preoperative PET between 2002-2008.PET positivity was determined by anatomical region of interest(AROI)findings for breast and axillary,sternal,and distant sites.The prognostic role of PET was examined as a qualitative binary factor(positive vs negative status)and as a continuous variable[maximum standard uptake value(SUVmax)]in multivariate survival analyses using Cox proportional hazards models.Among the 104 identified patients who received PET,36 were further analyzed for the SUVmax in the AROI.RESULTS Poor OS within the 15-year study period was predicted by PET-positive status for axillary(P=0.033),sternal(P=0.033),and combined PET-axillary/sternal(P=0.008)nodes.Poor disease-free survival was associated with PET-positive axillary status(P=0.040)and combined axillary/sternal status(P=0.023).Cox models confirmed the long-term prognostic value of combined PETaxillary/sternal status[hazard ratio(HR):3.08,95%confidence interval:1.42-6.69].SUVmax of ipsilateral breast and axilla as continuous covariates were significant predictors of long-term OS with HRs of 1.25(P=0.048)and 1.54(P=0.029),corresponding to relative increase in the risk of death of 25%and 54%per SUVmax unit,respectively.In addition,the ratio of the ipsilateral axillary SUVmax over the contralateral axillary SUVmax was the most significant OS predictor(P=0.027),with 1.94 HR,indicating a two-fold relative increase of mortality risk.CONCLUSION Preoperative PET is valuable for prediction of long-term survival.Ipsilateral axillary SUVmax ratio over the uninvolved side represents a new prognostic finding that warrants further investigation. 展开更多
关键词 Restricted mean survival time Long-term prognosis Overall survival Preoperative workup Breast surgery positron-emission tomography scan
下载PDF
Positron-emission tomography for hepatocellular carcinoma:Current status and future prospects 被引量:7
2
作者 Ren-Cai Lu Bo She +4 位作者 Wen-Tao Gao Yun-Hai Ji Dong-Dong Xu Quan-Shi Wang Shao-Bo Wang 《World Journal of Gastroenterology》 SCIE CAS 2019年第32期4682-4695,共14页
Hepatocellular carcinoma(HCC)is one of the leading causes of cancer mortality worldwide.Various imaging modalities provide important information about HCC for its clinical management.Since positron-emission tomography... Hepatocellular carcinoma(HCC)is one of the leading causes of cancer mortality worldwide.Various imaging modalities provide important information about HCC for its clinical management.Since positron-emission tomography(PET)or PET-computed tomography was introduced to the oncologic setting,it has played crucial roles in detecting,distinguishing,accurately staging,and evaluating local,residual,and recurrent HCC.PET imaging visualizes tissue metabolic information that is closely associated with treatment.Dynamic PET imaging and dual-tracer have emerged as complementary techniques that aid in various aspects of HCC diagnosis.The advent of new radiotracers and the development of immuno-PET and PET-magnetic resonance imaging have improved the ability to detect lesions and have made great progress in treatment surveillance.The current PET diagnostic capabilities for HCC and the supplementary techniques are reviewed herein. 展开更多
关键词 HEPATOCELLULAR CARCINOMA positron-emission tomography Radiotracer Immuno-positron EMISSION tomography
下载PDF
Findings of <sup>18</sup>F-Fluorodeoxyglucose Positron-Emission Tomography in Methotrexate-Related Lymphoproliferative Disorder
3
作者 Atsushi K. Kono Kazuhiro Kitajima +3 位作者 Hiroshi Mmatsuoka Kyoko Otani Tomoo Itoh Kazuro Sugimura 《Open Journal of Radiology》 2014年第4期293-300,共8页
Introduction: The use of methotrexate (MTX) for rheumatoid arthritis (RA) is increasing. However, the immune suppression state leads to the occurrence of lymphoproliferative disorder (MTX-LPD). The purpose of this stu... Introduction: The use of methotrexate (MTX) for rheumatoid arthritis (RA) is increasing. However, the immune suppression state leads to the occurrence of lymphoproliferative disorder (MTX-LPD). The purpose of this study was to describe the findings of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in MTX-LPD patients, and compare it with non-MTX-related malignant lymphoma (ML). Materials and Methods: We retrospectively reviewed 11 MTX-LPD patients (9 female, mean age 68.3 years) and 21 ML patients (7 female, mean age 60.6 years) with a histopathological diagnosis. FDG-PET imaging was performed using a standard oncology procedure. We assessed the disease distribution based on FDG-PET images and measured the maximum standardized up take values (SUVmax) for each region. Results: Mean values of SUVmax in MTX-LPD and ML were 14.6 and 17.2, respectively (p = 0.49). In MTX-LPD, 55 lesions met the Cotswold classification, consisting of 37 nodal and 18 extranodal lesions. In ML, 82 lesions were found, consisting of 68 nodal and 14 extranodal lesions. MTX-LPD showed a higher incident of the involvement in extranodal lesions throughout the whole body (p < 0.001). Conclusion: Because this disease occurs widely throughout the whole body, we need to pay attention to the less frequent sites as well when performing PET imaging in patients with MTX-LPD. 展开更多
关键词 FLUORODEOXYGLUCOSE (FDG) F 18 Lymphoma METHOTREXATE positron-emission tomography (PET) RHEUMATOID ARTHRITIS
下载PDF
Positron-emission tomography/computed tomography imaging in head and neck oncology:An update
4
作者 Viet D Nguyen Bundhit Tantiwongkosi +1 位作者 Wyatt J Weinheimer Frank R Miller 《World Journal of Otorhinolaryngology》 2016年第2期23-32,共10页
Cancers of the head and neck account for more than half a million cases worldwide annually, with a significant majority diagnosed as squamous cell carcinoma(HNSCC). Imaging studies such as contrast-enhanced computed t... Cancers of the head and neck account for more than half a million cases worldwide annually, with a significant majority diagnosed as squamous cell carcinoma(HNSCC). Imaging studies such as contrast-enhanced computed tomography(CT), magnetic resonance imaging(MRI) and ^(18)F-2-fluoro-2-deoxy-D-glucose positron-emission tomography/computed tomography(^(18)F-FDG PET/CT) are widely used to determine the presence and extent of tumors and metastatic disease, both before and after treatment. Advances in PET/CT imaging have allowed it to emerge as a superior imaging modality compared to both CT and MRI, especially in detection of carcinoma of unknown primary, cervical lymph node metastasis, distant metastasis, residual/recurrent cancer and second primary tumors, often leading to alteration in management. PET/CT biomarker may further provide an overall assessment of tumor aggressiveness with prognostic implications. As new developments emerged leading to better understanding and use of PET/CT in head and neck oncology, the aim of this article is to review the roles of PET/CT in both pre- and post-treatment management of HNSCC and PET-derived parameters as prognostic indicators. 展开更多
关键词 Positron emission tomography STAGING Diagnosis Computed tomography Head and neck cancer Management of squamous cell carcinoma Carcinoma of unknown primary Second primary malignancy SURVEILLANCE RECURRENCE PROGNOSIS
下载PDF
Recent progress in the applications of presynaptic dopaminergic positron emission tomography imaging in parkinsonism
5
作者 Yujie Yang Xinyi Li +7 位作者 Jiaying Lu Jingjie Ge Mingjia Chen Ruixin Yao Mei Tian Jian Wang Fengtao Liu Chuantao Zuo 《Neural Regeneration Research》 SCIE CAS 2025年第1期93-106,共14页
Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.... Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.This review provides a comprehensive summary of the latest developments in the application of presynaptic dopaminergic positron emission tomography imaging in disorders that manifest parkinsonism.We conducted a thorough literature search using reputable databases such as PubMed and Web of Science.Selection criteria involved identifying peer-reviewed articles published within the last 5 years,with emphasis on their relevance to clinical applications.The findings from these studies highlight that presynaptic dopaminergic positron emission tomography has demonstrated potential not only in diagnosing and differentiating various Parkinsonian conditions but also in assessing disease severity and predicting prognosis.Moreover,when employed in conjunction with other imaging modalities and advanced analytical methods,presynaptic dopaminergic positron emission tomography has been validated as a reliable in vivo biomarker.This validation extends to screening and exploring potential neuropathological mechanisms associated with dopaminergic depletion.In summary,the insights gained from interpreting these studies are crucial for enhancing the effectiveness of preclinical investigations and clinical trials,ultimately advancing toward the goals of neuroregeneration in parkinsonian disorders. 展开更多
关键词 aromatic amino acid decarboxylase brain imaging dopamine transporter Parkinson’s disease PARKINSONISM positron emission tomography presynaptic dopaminergic function vesicle monoamine transporter type 2
下载PDF
Macular microvascular and structural changes on optical coherence tomography angiography in atypical optic neuritis
6
作者 Chinmay Mahatme Madhurima Kaushik +2 位作者 Veerappan Rathinasabapathy Saravanan Karthik Kumar Virna M Shah 《World Journal of Methodology》 2025年第1期88-94,共7页
BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic im... BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases. 展开更多
关键词 Optical coherence tomography angiography Atypical optic neuritis Macular microvascular changes Neuromyelitis optica spectrum disorders Myelin oligodendrocyte glycoprotein antibody disorder
下载PDF
Tomographic reconstruction of the Earth’s magnetosheath from multiple spacecraft:a theoretical study 被引量:2
7
作者 A.M.Jorgensen TianRan Sun +4 位作者 Y.Huang L.Li R.Xu L.Dai Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期204-214,共11页
Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous recon... Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous reconstruction of the magnetosheath and magnetopause using a few images recorded simultaneously from a few spacecraft.This work is motivated by the prospect of possibly having two or three soft X-ray imagers in space in the coming years,and that many phenomena which occur at the magnetopause boundary,such as reconnection events and pressure pulse responses,do not lend themselves as well to superposed epoch analysis.If the reconstruction is successful-which we demonstrate in this paper that it can be-this collection of imagers can be used to reconstruct the magnetosheath and magnetopause from a single image from each spacecraft,allowing for high time resolution reconstructions.In this paper we explore the reconstruction using,two,three,and four spacecraft.We show that the location of the subsolar point of the magnetopause can be determined with just two satellites,and that volume emissions of soft X-rays,and the shape of the boundary,can be reconstructed using three or more satellites. 展开更多
关键词 MAGNETOSHEATH tomography soft X-ray imaging SMILE
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:4
8
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst Computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
9
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
IN VIVO VALIDATION OF DUAL-MODALITY SYSTEM FOR SIMULTANEOUS POSITRON EMISSION TOMOGRAPHY AND OPTICAL TOMOGRAPHIC IMAGING
10
作者 XIN WANG BIN ZHANG +4 位作者 XU CAO FEI LIU SHUANGQUAN LIU BAOCI SHAN JING BAI 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第2期165-171,共7页
We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast canc... We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast cancer cells which expressed redfluorescent protein(RFP).For FMT system,reflective illumination mode was adopted with full-angle data acquisition.[18F]-Fluorodeoxyglucose([18F]-FDG)was used as radioactive tracer for PET.Both data were acquired simultaneously and then reconstructed separately before fusion.Fluorescent tomography results showed exactly where the tumor was located while PET results offered more metabolic information.Results confirmed feasibility for tumor detection and showed superiority to single modality imaging. 展开更多
关键词 Dual-modality imaging positron emission tomography fluorescence molecular tomography
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
11
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
Preoperative prediction of lymphovascular and perineural invasion in gastric cancer using spectral computed tomography imaging and machine learning 被引量:1
12
作者 Hui-Ting Ge Jian-Wu Chen +5 位作者 Li-Li Wang Tian-Xiu Zou Bin Zheng Yuan-Fen Liu Yun-Jing Xue Wei-Wen Lin 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期542-555,共14页
BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative predictio... BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative prediction of LVI/PNI status could help clinicians identify high-risk patients and guide treatment deci-sions.However,prior models using conventional computed tomography(CT)images to predict LVI or PNI separately have had limited accuracy.Spectral CT provides quantitative enhancement parameters that may better capture tumor invasion.We hypothesized that a predictive model combining clinical and spectral CT parameters would accurately preoperatively predict LVI/PNI status in GC patients.AIM To develop and test a machine learning model that fuses spectral CT parameters and clinical indicators to predict LVI/PNI status accurately.METHODS This study used a retrospective dataset involving 257 GC patients(training cohort,n=172;validation cohort,n=85).First,several clinical indicators,including serum tumor markers,CT-TN stages and CT-detected extramural vein invasion(CT-EMVI),were extracted,as were quantitative spectral CT parameters from the delineated tumor regions.Next,a two-step feature selection approach using correlation-based methods and information gain ranking inside a 10-fold cross-validation loop was utilized to select informative clinical and spectral CT parameters.A logistic regression(LR)-based nomogram model was subsequently constructed to predict LVI/PNI status,and its performance was evaluated using the area under the receiver operating characteristic curve(AUC).RESULTS In both the training and validation cohorts,CT T3-4 stage,CT-N positive status,and CT-EMVI positive status are more prevalent in the LVI/PNI-positive group and these differences are statistically significant(P<0.05).LR analysis of the training group showed preoperative CT-T stage,CT-EMVI,single-energy CT values of 70 keV of venous phase(VP-70 keV),and the ratio of standardized iodine concentration of equilibrium phase(EP-NIC)were independent influencing factors.The AUCs of VP-70 keV and EP-NIC were 0.888 and 0.824,respectively,which were slightly greater than those of CT-T and CT-EMVI(AUC=0.793,0.762).The nomogram combining CT-T stage,CT-EMVI,VP-70 keV and EP-NIC yielded AUCs of 0.918(0.866-0.954)and 0.874(0.784-0.936)in the training and validation cohorts,which are significantly higher than using each of single independent factors(P<0.05).CONCLUSION The study found that using portal venous and EP spectral CT parameters allows effective preoperative detection of LVI/PNI in GC,with accuracy boosted by integrating clinical markers. 展开更多
关键词 Spectral computed tomography Gastric cancer Lymphovascular invasion Perineural invasion
下载PDF
Computed tomography for prediction of esophageal variceal bleeding 被引量:1
13
作者 Mohammed Elhendawy Ferial Elkalla 《World Journal of Gastrointestinal Endoscopy》 2024年第3期175-177,共3页
This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is ... This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is one of the most common and severe complications related to portal hypertension(PH).Despite marked advances in its management during the last three decades,EVB is still associated with significant morbidity and mortality.The risk of first EVB is related to the severity of both PH and liver disease,and to the size and endoscopic appearance of esophageal varices.Indeed,hepatic venous pressure gradient(HVPG)and esophagogastroduodenoscopy(EGD)are currently recognized as the“gold standard”and the diagnostic reference standard for the prediction of EVB,respectively.However,HVPG is an invasive,expensive,and technically complex procedure,not widely available in clinical practice,whereas EGD is mainly limited by its invasive nature.In this scenario,computed tomography(CT)has been recently proposed as a promising modality for the non-invasive prediction of EVB.While CT serves solely as a diagnostic tool and cannot replace EGD or HVPG for delivering therapeutic and physiological information,it has the potential to enhance the prediction of EVB more effectively when combined with liver disease scores,HVPG,and EGD.However,to date,evidence concerning the role of CT in this setting is still lacking,therefore we aim to summarize and discuss the current evidence concerning the role of CT in predicting the risk of EVB. 展开更多
关键词 Esophageal variceal bleeding Variceal upper gastrointestinal bleeding Portal hypertension Computed tomography Computed tomography angiography
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients 被引量:1
14
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Lymphatic plastic bronchitis and primary chylothorax: A study based on computed tomography lymphangiography 被引量:1
15
作者 Xing-Peng Li Yan Zhang +4 位作者 Xiao-Li Sun Kun Hao Meng-Ke Liu Qi Hao Ren-Gui Wang 《World Journal of Clinical Cases》 SCIE 2024年第14期2350-2358,共9页
BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two disea... BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two diseases.AIM To improve the diagnosis of lymphatic PB or primary chylothorax,a retrospective analysis of the clinical features and CTL characteristics of 71 patients diagnosed with lymphatic PB or primary chylothorax was performed.METHODS The clinical and CTL data of 71 patients(20 with lymphatic PB,41 with primary chylothorax,and 10 with lymphatic PB with primary chylothorax)were collected retrospectively.CTL was performed in all patients.The clinical manifestations,CTL findings,and conventional chest CT findings of the three groups of patients were compared.The chi-square test or Fisher's exact test was used to compare the differences among the three groups.A difference was considered to be statistically significant when P<0.05.RESULTS(1)The percentages of abnormal contrast medium deposits on CTL in the three groups were as follows:Thoracic duct outlet in 14(70.0%),33(80.5%)and 8(80.0%)patients;peritracheal region in 18(90.0%),15(36.6%)and 8(80.0%)patients;pleura in 6(30.0%),33(80.5%)and 9(90.0%)patients;pericardium in 6(30.0%),6(14.6%)and 4(40.0%)patients;and hilum in 16(80.0%),11(26.8%)and 7(70.0%)patients;and(2)the abnormalities on conven-tional chest CT in the three groups were as follows:Ground-glass opacity in 19(95.0%),18(43.9%)and 8(80.0%)patients;atelectasis in 4(20.0%),26(63.4%)and 7(70.0%)patients;interlobular septal thickening in 12(60.0%),11(26.8%)and 3(30.0%)patients;bronchovascular bundle thickening in 14(70.0%),6(14.6%)and 4(40.0%)patients;localized mediastinal changes in 14(70.0%),14(34.1%),and 7(70.0%)patients;diffuse mediastinal changes in 6(30.0%),5(12.2%),and 3(30.0%)patients;cystic lesions in the axilla in 2(10.0%),6(14.6%),and 2(20.0%)patients;and cystic lesions in the chest wall in 0(0%),2(4.9%),and 2(4.9%)patients.CONCLUSION CTL is well suited to clarify the characteristics of lymphatic PB and primary chylothorax.This method is an excellent tool for diagnosing these two diseases. 展开更多
关键词 LYMPHATIC Plastic bronchitis Primary chylothorax Direct lymphangiography Computed tomography lymphangiography
下载PDF
Evaluation of retinal and choroidal thickness changes in overweight and obese adults without ocular symptoms by swept-source optical coherence tomography 被引量:1
16
作者 Qing-Jian Li Sheng-Mei Zhou +7 位作者 Ling-Yu Zhang An-Ni Lin Yang Zhang Jing Jiang Xin Che Yi-Wen Qian Yan Liu Zhi-Liang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期707-712,共6页
AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass... AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults. 展开更多
关键词 OVERWEIGHT OBESITY body mass index choroidal thickness retinal thickness swept-source optical coherence tomography
下载PDF
Computed tomography for the prediction of oesophageal variceal bleeding:A surrogate or complementary to the gold standard? 被引量:1
17
作者 Yasser Fouad Mohamed Alboraie 《World Journal of Gastrointestinal Endoscopy》 2024年第3期98-101,共4页
In this editorial we comment on the in-press article in the World Journal of Gastrointestinal endoscopy about the role of computed tomography(CT)for the prediction of esophageal variceal bleeding.The mortality and mor... In this editorial we comment on the in-press article in the World Journal of Gastrointestinal endoscopy about the role of computed tomography(CT)for the prediction of esophageal variceal bleeding.The mortality and morbidity are much increased in patients with chronic liver diseases when complicated with variceal bleeding.Predicting the patient at a risk of bleeding is extremely important and receives a great deal of attention,paving the way for primary prophylaxis either using medical treatment including carvedilol or propranolol,or endoscopic band ligation.Endoscopic examination and the hepatic venous pressure gradient are the gold standards in the diagnosis and prediction of variceal bleeding.Several non-invasive laboratory and radiological examinations are used for the prediction of variceal bleeding.The contrast-enhanced multislice CT is a widely used non-invasive,radiological examination that has many advantages.In this editorial we briefly comment on the current research regarding the use of CT as a non-invasive tool in predicting the variceal bleeding. 展开更多
关键词 Computed tomography Esophageal varices BLEEDING Non-invasive predictor ENDOSCOPY
下载PDF
Avoiding misdiagnosis of multilocular thymic cysts as malignant tumors on computer tomography 被引量:1
18
作者 Yu-Hong Zhang Yan-Miao Liu +2 位作者 Kai-Li Shen Jing-Jing Wu Fu-Shan Tang 《World Journal of Clinical Cases》 SCIE 2024年第19期3671-3675,共5页
This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tum... This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tumor,resulting in an unnecessary surgical procedure.Both MTCs and thymic tumors are rare conditions that heavily rely on radiological imaging for accurate diagnosis.However,the similarity in their imaging presentations can lead to misinterpretation,resulting in unnecessary surgical procedures.Due to the ongoing lack of comprehensive knowledge about MTCs and thymic tumors,we offer a summary of diagnostic techniques documented in recent literature and examine potential causes of misdiagnosis.When computer tomography(CT)values surpass 20 Hounsfield units and display comparable morphology,there is a risk of misdiagnosing MTCs as thymic tumors.Employing various differential diagnostic methods like biopsy,molecular biology,multi-slice CT,CT functional imaging,positron emission tomography/CT molecular functional imaging,magnetic resonance imaging and radiomics,proves advantageous in reducing clinical misdiagnosis.A deeper understanding of these conditions requires increased attention and exploration by healthcare providers.Moreover,the continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future.continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future. 展开更多
关键词 Thymic tumor Multilocular thymic cyst MISDIAGNOSIS Differential diagnosis Imaging manifestation Computed tomography
下载PDF
Computed tomography-based nomogram of Siewert type Ⅱ/Ⅲ adenocarcinoma of esophagogastric junction to predict response to docetaxel, oxaliplatin and S-1 被引量:1
19
作者 Chuan-Qinyuan Zhou Dan Gao +7 位作者 Yan Gui Ning-Pu Li Wen-Wen Guo Hai-Ying Zhou Rui Li Jing Chen Xiao-Ming Zhang Tian-Wu Chen 《World Journal of Radiology》 2024年第1期9-19,共11页
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba... BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS. 展开更多
关键词 Esophagogastric junction ADENOCARCINOMA Neoadjuvant chemotherapy RESPONSE tomography X-ray computed Predictor
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography 被引量:1
20
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部