Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca...Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.展开更多
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ...AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.展开更多
Extracapsular cataract extraction was performed combined with posterior chamber intraocular lens implantation on 120 inpatients (122 eyes) with traumatic cataract from 1992 to 1997. The results revealed that this comb...Extracapsular cataract extraction was performed combined with posterior chamber intraocular lens implantation on 120 inpatients (122 eyes) with traumatic cataract from 1992 to 1997. The results revealed that this combined operation can make most of them get useful visual acuity, although they were often accompanied with several comlicated eye injuries. We think the most important thing is to choose suitable opertion time, the reasonable operation method and take close followup after operation.展开更多
Background:To evaluate the long-term safety,efficacy,predictability,and stability of implantable collamer lens with a central hole(EVO ICL)implantation for correcting high myopia(HM)and super high myopia(SHM).Methods:...Background:To evaluate the long-term safety,efficacy,predictability,and stability of implantable collamer lens with a central hole(EVO ICL)implantation for correcting high myopia(HM)and super high myopia(SHM).Methods:This prospective study evaluated 83 eyes of 46 patients who were divided into groups based on their spherical equivalent refractive error(SE):HM group(−12 D≤SE<−6 D)and SHM group(SE<−12 D).They were followed up for 5 years after ICL implantation;assessments of uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),manifest refractive error,axial length,intraocular pressure,corneal endothelial cell density,and vault were conducted,and a questionnaire was administered.ResuIts:At 5 years postoperatively,the safety indices of the HM and SHM groups were 1.03±0.10 and 1.32±0.39,and the efficacy indices were 0.83±0.25 and 0.86±0.32,respectively.In the HM group,60.47%and 79.07%of the eyes were within±0.50 D and±1.00 D of the attempted correction,while it was achieved for 22.50%and 47.50%of the eyes in the SHM group,respectively.The SE of the HM group decreased from−9.72±1.41 D preoperatively to 0.04±0.39 D 1 month postoperatively and−0.67±0.57 D 5 years postoperatively,while in the SHM group,it decreased from−15.78±3.06 D preoperatively to−0.69±0.97 D 1 month postoperatively and−1.74±1.19 D 5 years postoperatively.Conclusion:EVO ICL implantation is safe,effective,and predictable for correcting HM and SHM.CDVA improved more after surgery for SHM,but the growth of axial length still needs attention.展开更多
Purpose:To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens(ICL,STAAR Surgical)with a central port.Methods:This prospective,ob...Purpose:To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens(ICL,STAAR Surgical)with a central port.Methods:This prospective,observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant.A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography(AS-OCT)device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery.Results:Preoperative mean pupil size under photopic conditions was 3.38±0.64 mm;after surgery,this increased to 3.48±0.61 mm.Mean pupil size under scotopic light conditions was 5.72±0.79 mm before surgery and 5.84±0.77 mm postoperatively.The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10±0.44 mm(P=0.078)and 0.12±0.58 mm(P=0.098),respectively.The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes(60%).The mean central vault value was 412±177μm under maximum miosis and 506±190μm under maximum mydriasis.We found a positive correlation between vault and differences in pupil diameter under all light conditions(P<0.05).Conclusion:Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane.The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault.展开更多
文摘Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.
基金Supported by National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y2023809).
文摘AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.
文摘Extracapsular cataract extraction was performed combined with posterior chamber intraocular lens implantation on 120 inpatients (122 eyes) with traumatic cataract from 1992 to 1997. The results revealed that this combined operation can make most of them get useful visual acuity, although they were often accompanied with several comlicated eye injuries. We think the most important thing is to choose suitable opertion time, the reasonable operation method and take close followup after operation.
基金supported by National Natural Science Foundation of China(Grant No.81770955)Joint Research Project of New Frontier Technology in municipal hospitals(Grant No.SHDC12018103)+3 种基金Project of Shanghai Science and Technology(Grant No.20410710100)Major Clinical Research Project of Shanghai Shenkang Hospital Development Center(Grant No.SHDC-2020CR1043B)Project of Shanghai Xuhui District Science and Technology(Grant No.2020-015)Shanghai Science and Technology Commission(Grant No.19140900700).
文摘Background:To evaluate the long-term safety,efficacy,predictability,and stability of implantable collamer lens with a central hole(EVO ICL)implantation for correcting high myopia(HM)and super high myopia(SHM).Methods:This prospective study evaluated 83 eyes of 46 patients who were divided into groups based on their spherical equivalent refractive error(SE):HM group(−12 D≤SE<−6 D)and SHM group(SE<−12 D).They were followed up for 5 years after ICL implantation;assessments of uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),manifest refractive error,axial length,intraocular pressure,corneal endothelial cell density,and vault were conducted,and a questionnaire was administered.ResuIts:At 5 years postoperatively,the safety indices of the HM and SHM groups were 1.03±0.10 and 1.32±0.39,and the efficacy indices were 0.83±0.25 and 0.86±0.32,respectively.In the HM group,60.47%and 79.07%of the eyes were within±0.50 D and±1.00 D of the attempted correction,while it was achieved for 22.50%and 47.50%of the eyes in the SHM group,respectively.The SE of the HM group decreased from−9.72±1.41 D preoperatively to 0.04±0.39 D 1 month postoperatively and−0.67±0.57 D 5 years postoperatively,while in the SHM group,it decreased from−15.78±3.06 D preoperatively to−0.69±0.97 D 1 month postoperatively and−1.74±1.19 D 5 years postoperatively.Conclusion:EVO ICL implantation is safe,effective,and predictable for correcting HM and SHM.CDVA improved more after surgery for SHM,but the growth of axial length still needs attention.
文摘Purpose:To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens(ICL,STAAR Surgical)with a central port.Methods:This prospective,observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant.A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography(AS-OCT)device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery.Results:Preoperative mean pupil size under photopic conditions was 3.38±0.64 mm;after surgery,this increased to 3.48±0.61 mm.Mean pupil size under scotopic light conditions was 5.72±0.79 mm before surgery and 5.84±0.77 mm postoperatively.The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10±0.44 mm(P=0.078)and 0.12±0.58 mm(P=0.098),respectively.The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes(60%).The mean central vault value was 412±177μm under maximum miosis and 506±190μm under maximum mydriasis.We found a positive correlation between vault and differences in pupil diameter under all light conditions(P<0.05).Conclusion:Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane.The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault.