While we studied pharmacokinetics of SM-12502 which was under development as an anti-PAF agent, we found three subjects showing a slow metabolic phenotype in its pharmacokinetics. Analyzing the genes for CYP2A6 from t...While we studied pharmacokinetics of SM-12502 which was under development as an anti-PAF agent, we found three subjects showing a slow metabolic phenotype in its pharmacokinetics. Analyzing the genes for CYP2A6 from the three subjects, we discovered that the three subjects possessed the whole CYP2A6 gene deletion (CYP2A6*4C), a novel genetic polymorphism of the CYP2A6 gene. Genetically engineered Salmonella YG7108 cells expressing human CYP2A6 or CYP2E1 together with the NADPH-CYP reductase were established in our laboratory to compare the mutagen-producing capacity of these enzymes for various N-nitrosamines. We found that CYP2E1 was responsible for the metabolic activation of N-nitrosamines with relatively short alkyl chains, whereas CYP2A6 was involved in the metabolic activation of N-nitrosamines possessing relatively bulky alkyl chains such as a tobacco-specific nitrosamine, NNK, which has been known to cause lung tumor in rodents. Thus, to examine a hypothesis that individuals possessing the CYP2A6*4C have the reduced risk of lung cancer due to the lack of the capacity of the metabolic activation of certain carcinogens in tobacco smoke, a case-control study was performed.展开更多
Background: Female sexual dysfunction (FSD) is a highly prevalent and often underestimated problem. However, large-scale, population-based epidemiological surveys of FSD are scarce in China. The present study was c...Background: Female sexual dysfunction (FSD) is a highly prevalent and often underestimated problem. However, large-scale, population-based epidemiological surveys of FSD are scarce in China. The present study was conducted to evaluate the prevalence and the potential risk factors of FSD across a selection of social groups in Beijing, China, based on the Female Sexual Function Index (FSFI). Methods: A cross-sectional study based on the multiple-stage cluster sampling was performed with adult women throughout the Dongcbeng and Shunyi districts of Beijing. The Chinese version of FSFI was used, as well as questions on demographic characteristics, the disease-related context, and social relationships. Results: A total of 6000 consecutive women entered this study, with an actual response from 5024 women, corresponding to a response rate of 83.7%. A total of 4697 (78.3%) questionnaires were effective. The prevalence of adult FSD in Beijing was 2973 (63.3%) using a score of 26.55 as the boundary value, whereas the total mean FSFI score was 23.92 ~ 6.37. However, 1423 (30.3%) women did not seek help. By multivariate logistic regression analysis, the possible potential risk factors included age (odds ratio [OR] = 1.051 ), dissatisfaction with the spouse's sexual ability (OR = 3.520), poor marital affection (OR = 2.087), spouse sexual difficulties (OR = 1.720), dissatisfaction with married life (OR = 1.476), living in a rural area (OR = 1.292), chronic pelvic pain (OR = 1.261), chronic disease (OR = 1.534), previous pelvic surgery (OR = 1.605), vaginal delivery (OR = 2.285), lower education (OR = 3.449) and postmenopausal (OR = 3.183). Conclusions: As suggested by the FSFI scores, female sexual problems are highly prevalent in Beijing. Dissatisfaction with the spouse's sexual ability, poor marital affection, sexual difficulties of the spouse, dissatisfaction with the marriage, rural life, CPP, and postmenopausal were conceivable risk factors for FSD in Beijing women.展开更多
Domestic coal stove is widely used in China, especially for countryside during heating period of winter, and polycyclic aromatic hydrocarbons (PAHs) are important in flue gas of the stove. By using dilution tunnel s...Domestic coal stove is widely used in China, especially for countryside during heating period of winter, and polycyclic aromatic hydrocarbons (PAHs) are important in flue gas of the stove. By using dilution tunnel system, samples of both gaseous and particulate phases from domestic coal combustion were collected and 18 PAH species were analyzed by GC-MS. The average emission factors of total 18 PAH species was 171.73 mg/kg, ranging from 140.75 to 229.11 mg/kg for bituminous coals, while was 93.98 mg/kg, ranging from 58.48 to 129.47 mg/kg for anthracite coals. PAHs in gaseous phases occupied 95% of the total of PAHs emission of coal combustion. In particulate phase, 3-ring and 4- ring PAHs were the main components, accounting for 80% of the total particulate PAHs. The total toxicity potency evaluated by benzo[a]pyrene-equivalent carcinogenic power, sum of 7 carcinogenic PAH components and 2,3,7,8-tetrachlorodibenzodioxin had a similar tendency. And as a result, the toxic potential of bituminous coal was higher than that of anthracite coal. Efficient emission control should be conducted to reduce PAH emissions in order to protect ecosystem and human health.展开更多
Large amounts of heavy metals discharged by industrial cities that are located along the middle reach of Yellow River, China have detrimental impacts on both the ecological environment and human health. In this study,...Large amounts of heavy metals discharged by industrial cities that are located along the middle reach of Yellow River, China have detrimental impacts on both the ecological environment and human health. In this study, fourteen surface sediment samples were taken in the middle reach of the Yellow River. Contents of Zn, Pb, Ni, Cu, Cr, Cd, As were measured, and the pollution status was assessed using three widely used pollution assessment methods, including the single factor index method, Nemerow pollution index method and potential ecological risk index. The concentrations of the studied heavy metals followed the order: Zn 〉 Cr 〉 Cu 〉 Ni 〉 Pb 〉 As 〉 Cd. Nearly 50% of sites had Cu and Cr accumulation. The concentration of Cu at the Yiluo River exceeded the secondary standard value of the Environmental quality standard for soils. Comparison of heavy metal concentrations between this study and other selected rivers indicated that Cu and Cr may be the major pollutants in our case. The single factor index indicated that many samples were at high levels of pollution for Cu and Cd; the Nemerow pollution index indicated that the Yihe River, Luohe River, Yiluo River and Huayuankou were polluted. According to the results of potential ecological risk assessment, Cd in the tributaries of Luo River, Yihe River,and Yiluo River showed high risk toward the ecosystem and human health, Cd in Huanyuankou and Cu in Yiluo River showed a middle level of risk and other samples were at a low level of risk.展开更多
Polycyclic aromatic hydrocarbons(PAHs) are carcinogenic or mutagenic and are important toxic pollutants in the flue gas of boilers. Two industrial grade biomass boilers were selected to investigate the characteristi...Polycyclic aromatic hydrocarbons(PAHs) are carcinogenic or mutagenic and are important toxic pollutants in the flue gas of boilers. Two industrial grade biomass boilers were selected to investigate the characteristics of particulate-bound PAHs: one biomass boiler retro-fitted from an oil boiler(BB1) and one specially designed(BB2) biomass boiler. One coal-fired boiler was also selected for comparison. By using a dilution tunnel system, particulate samples from boilers were collected and 10 PAH species were analyzed by gas chromatography–mass spectrometry(GC–MS). The total emission factors(EFs) of PAHs ranged from 0.0064 to0.0380 mg/kg, with an average of 0.0225 mg/kg, for the biomass boiler emission samples. The total PAH EFs for the tested coal-fired boiler were 1.8 times lower than the average value of the biomass boilers. The PAH diagnostic ratios for wood pellets and straw pellets were similar.The ratio of indeno(1,2,3-cd)pyrene/[indeno(1,2,3-cd)pyrene + benzo(g,h,i)perylene] for the two biomass boilers was lower than those of the reference data for other burning devices, which can probably be used as an indicator to distinguish the emission of biomass boilers from that of industrial coal-fired boilers and residential stoves. The toxic potential of the emission from wood pellet burning was higher than that from straw pellet burning, however both of them were much lower than residential stove exhausts.展开更多
文摘While we studied pharmacokinetics of SM-12502 which was under development as an anti-PAF agent, we found three subjects showing a slow metabolic phenotype in its pharmacokinetics. Analyzing the genes for CYP2A6 from the three subjects, we discovered that the three subjects possessed the whole CYP2A6 gene deletion (CYP2A6*4C), a novel genetic polymorphism of the CYP2A6 gene. Genetically engineered Salmonella YG7108 cells expressing human CYP2A6 or CYP2E1 together with the NADPH-CYP reductase were established in our laboratory to compare the mutagen-producing capacity of these enzymes for various N-nitrosamines. We found that CYP2E1 was responsible for the metabolic activation of N-nitrosamines with relatively short alkyl chains, whereas CYP2A6 was involved in the metabolic activation of N-nitrosamines possessing relatively bulky alkyl chains such as a tobacco-specific nitrosamine, NNK, which has been known to cause lung tumor in rodents. Thus, to examine a hypothesis that individuals possessing the CYP2A6*4C have the reduced risk of lung cancer due to the lack of the capacity of the metabolic activation of certain carcinogens in tobacco smoke, a case-control study was performed.
文摘Background: Female sexual dysfunction (FSD) is a highly prevalent and often underestimated problem. However, large-scale, population-based epidemiological surveys of FSD are scarce in China. The present study was conducted to evaluate the prevalence and the potential risk factors of FSD across a selection of social groups in Beijing, China, based on the Female Sexual Function Index (FSFI). Methods: A cross-sectional study based on the multiple-stage cluster sampling was performed with adult women throughout the Dongcbeng and Shunyi districts of Beijing. The Chinese version of FSFI was used, as well as questions on demographic characteristics, the disease-related context, and social relationships. Results: A total of 6000 consecutive women entered this study, with an actual response from 5024 women, corresponding to a response rate of 83.7%. A total of 4697 (78.3%) questionnaires were effective. The prevalence of adult FSD in Beijing was 2973 (63.3%) using a score of 26.55 as the boundary value, whereas the total mean FSFI score was 23.92 ~ 6.37. However, 1423 (30.3%) women did not seek help. By multivariate logistic regression analysis, the possible potential risk factors included age (odds ratio [OR] = 1.051 ), dissatisfaction with the spouse's sexual ability (OR = 3.520), poor marital affection (OR = 2.087), spouse sexual difficulties (OR = 1.720), dissatisfaction with married life (OR = 1.476), living in a rural area (OR = 1.292), chronic pelvic pain (OR = 1.261), chronic disease (OR = 1.534), previous pelvic surgery (OR = 1.605), vaginal delivery (OR = 2.285), lower education (OR = 3.449) and postmenopausal (OR = 3.183). Conclusions: As suggested by the FSFI scores, female sexual problems are highly prevalent in Beijing. Dissatisfaction with the spouse's sexual ability, poor marital affection, sexual difficulties of the spouse, dissatisfaction with the marriage, rural life, CPP, and postmenopausal were conceivable risk factors for FSD in Beijing women.
基金supported by the Natural Science Foundation of China(No.41275135,41105090)the National High Technology Research and Development Program(863)of China(No.2012AA063506)the Open Foundation of Environmental Simulation and Pollution Control State Key Laboratories(Peking University)
文摘Domestic coal stove is widely used in China, especially for countryside during heating period of winter, and polycyclic aromatic hydrocarbons (PAHs) are important in flue gas of the stove. By using dilution tunnel system, samples of both gaseous and particulate phases from domestic coal combustion were collected and 18 PAH species were analyzed by GC-MS. The average emission factors of total 18 PAH species was 171.73 mg/kg, ranging from 140.75 to 229.11 mg/kg for bituminous coals, while was 93.98 mg/kg, ranging from 58.48 to 129.47 mg/kg for anthracite coals. PAHs in gaseous phases occupied 95% of the total of PAHs emission of coal combustion. In particulate phase, 3-ring and 4- ring PAHs were the main components, accounting for 80% of the total particulate PAHs. The total toxicity potency evaluated by benzo[a]pyrene-equivalent carcinogenic power, sum of 7 carcinogenic PAH components and 2,3,7,8-tetrachlorodibenzodioxin had a similar tendency. And as a result, the toxic potential of bituminous coal was higher than that of anthracite coal. Efficient emission control should be conducted to reduce PAH emissions in order to protect ecosystem and human health.
基金supported by the National Basic Research Program (973) of China (No. 2015CB453103)the Strategic Priority Research Program of the Chinese Academy of Sciences (No. XDB14020102)the National Natural Science Foundation of China (Nos. 21477150 and 21321004)
文摘Large amounts of heavy metals discharged by industrial cities that are located along the middle reach of Yellow River, China have detrimental impacts on both the ecological environment and human health. In this study, fourteen surface sediment samples were taken in the middle reach of the Yellow River. Contents of Zn, Pb, Ni, Cu, Cr, Cd, As were measured, and the pollution status was assessed using three widely used pollution assessment methods, including the single factor index method, Nemerow pollution index method and potential ecological risk index. The concentrations of the studied heavy metals followed the order: Zn 〉 Cr 〉 Cu 〉 Ni 〉 Pb 〉 As 〉 Cd. Nearly 50% of sites had Cu and Cr accumulation. The concentration of Cu at the Yiluo River exceeded the secondary standard value of the Environmental quality standard for soils. Comparison of heavy metal concentrations between this study and other selected rivers indicated that Cu and Cr may be the major pollutants in our case. The single factor index indicated that many samples were at high levels of pollution for Cu and Cd; the Nemerow pollution index indicated that the Yihe River, Luohe River, Yiluo River and Huayuankou were polluted. According to the results of potential ecological risk assessment, Cd in the tributaries of Luo River, Yihe River,and Yiluo River showed high risk toward the ecosystem and human health, Cd in Huanyuankou and Cu in Yiluo River showed a middle level of risk and other samples were at a low level of risk.
基金supported by the National Natural Science Foundation of China (Nos.41105090,41275135)the International S&T Cooperation Program of China (No.2012DFG90290)+1 种基金the National High Technology Research and Development Program (863) of China (No.2012AA063506)China Ministry of Environmental Protection's Special Funds for Scientific Research on Public Welfare (No.20130916)
文摘Polycyclic aromatic hydrocarbons(PAHs) are carcinogenic or mutagenic and are important toxic pollutants in the flue gas of boilers. Two industrial grade biomass boilers were selected to investigate the characteristics of particulate-bound PAHs: one biomass boiler retro-fitted from an oil boiler(BB1) and one specially designed(BB2) biomass boiler. One coal-fired boiler was also selected for comparison. By using a dilution tunnel system, particulate samples from boilers were collected and 10 PAH species were analyzed by gas chromatography–mass spectrometry(GC–MS). The total emission factors(EFs) of PAHs ranged from 0.0064 to0.0380 mg/kg, with an average of 0.0225 mg/kg, for the biomass boiler emission samples. The total PAH EFs for the tested coal-fired boiler were 1.8 times lower than the average value of the biomass boilers. The PAH diagnostic ratios for wood pellets and straw pellets were similar.The ratio of indeno(1,2,3-cd)pyrene/[indeno(1,2,3-cd)pyrene + benzo(g,h,i)perylene] for the two biomass boilers was lower than those of the reference data for other burning devices, which can probably be used as an indicator to distinguish the emission of biomass boilers from that of industrial coal-fired boilers and residential stoves. The toxic potential of the emission from wood pellet burning was higher than that from straw pellet burning, however both of them were much lower than residential stove exhausts.