The low voltage powerline is becoming a powerful solution to home network, building automation, and internet access as a result of its wide distribution, easy access and little maintenance. The character of powerline ...The low voltage powerline is becoming a powerful solution to home network, building automation, and internet access as a result of its wide distribution, easy access and little maintenance. The character of powerline channel is very complicated because it is an open net. This article analysed the character of the powerline channel,introduced the basics of OFDM(Orthogonal Frequency Division Multiplexing), and studied the OFDM applied into powerline high speed digital communication.展开更多
In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office...In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate.展开更多
Based on the experimental results, a simplified model for low-voltage powerline used as a high frequency communication channel is presented. With this model, the Orthogonal Frequency Division Multiplexing (OFDM) based...Based on the experimental results, a simplified model for low-voltage powerline used as a high frequency communication channel is presented. With this model, the Orthogonal Frequency Division Multiplexing (OFDM) based high rate digital communication over low-voltage powerline is analyzed and simulated. The capability of the signal transmission system in overcoming multi-path interference and selection of the system parameters are discussed. And time-domain simulation is carried out to investigate the transmission capability of the OFDM communication system for different mapping schemes and transmission power levels. Simulation results show that it is possible to realize high rate digital communication over low-voltage powerline using OFDM when the transmitted power is large enough.展开更多
Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and redu...Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference.展开更多
The development trend of PLC is that the functions are more, the integration level is greater and the network function is greater. Nowadays, the manufacturers of PLC develop there own network. PLC technique has two de...The development trend of PLC is that the functions are more, the integration level is greater and the network function is greater. Nowadays, the manufacturers of PLC develop there own network. PLC technique has two development trends. On one hand, PLC network system is not a self-contained closed system any longer and develops towards open system. Various PLC not only has distinctive PLC network systems and completes device control task, but also network with the superior computer management system to realize information exchange, which makes it become one part of information management system. On the other hand, the field-bus technique is widely applied. PLC is connected with the intelligent equipments installed on site such as intelligent instrument, sensor, intelligent solenoid valve, intelligent drive actuator by a transmission media ( such as twisted pair, coaxial cable and cable), and they transmit information mutually according to the same communication protocol, which can form a field industrial control network. Compared with single PLC remote network, the network not only has the advantages of flexible configurations, easy expansion, low cost and higher cost perfomaance, but also has opening significance.展开更多
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s...Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.展开更多
Noise characteristics of an indoor power line network strongly influence the link capability to achieve high data rates. The appliances shared with PLC modems in the same powerline network generate different types of ...Noise characteristics of an indoor power line network strongly influence the link capability to achieve high data rates. The appliances shared with PLC modems in the same powerline network generate different types of noises, among them the impulsive noises are the main source of interference resulting in signal distortions and bit errors during data transmission. With regard to impulsive noise many models were proposed in the literature and shared the same impulsive noise definition: “unpredictable noises measured in the receiver side”. Authors are, consequently, confronted to model thousands of impulsive noises whose plurality would very likely come from the diversity of paths that the original impulsive noise took. In this paper, an innovative modelling approach is applied to impulsive noises which are studied here directly at their sources. Noise at receiver would be simply the noise model at source convolved by powerline channel block. In the new analytical model, the impulsive noise at source is described by a succession of short pulses, each modeled by a phase-shifted Gaussian. Noises at source are classified into 6 different classes [1], and a noise generator is established for each class.展开更多
This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) ...This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) based OFDM-CDMA(Code Division Multiple Access) communication systems for high speed Power Line Communication (PLC) channels.This system gives much better robustness to Inter-Channel Interference (ICI), Multi-User Interference (MUI) and noise interference, which is verified by simulation.展开更多
Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queu...Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queueing theoretic framework. The proposed PLC network model consists of a base station (BS), which is located at a transformer station and connected to the backbone communication networks, and a number of subscriber stations that are interconnected with each other and with the BS via the power line transmission medium. An orthogonal frequency division multiplexing based technique is assumed for forming the transmission channels in a frequency spectrum. The channels are subject to failure during service due to noise. We determine the steady-state solution of the proposed model and derive a set of performance metrics of interest. Numerical and simulation results are presented to provide further insights into the analytical results. The proposed modeling method is expected to be used for evaluation and design of future PLC networks.展开更多
Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the intere...Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the interest of both utilities and residents. They help to achieve load balance and increase the grid reliability by encouraging residents to reduce their power usage during peak load periods in return for incentives. To automate this process, appliances, in-house sensors, and the AMI controller need to be networked together. In this paper, we compare mainstream network technologies applicable to home appliance control and propose a solution combining Power Line Communication (PLC) with wireless communication in smart homes for the purpose of energy saving. We extended NS-2, a popular network simulator, to model such combined network scenarios. Using a number of different routing strategies, we then model and evaluate the network performance of DR programs in smart homes in such a combined network.展开更多
A kind of integrated network architecture visible light communication (VLC) and power line communication (PLC) is put forward. This architecture is low cost and easy to implement which overcomes the shortcoming of the...A kind of integrated network architecture visible light communication (VLC) and power line communication (PLC) is put forward. This architecture is low cost and easy to implement which overcomes the shortcoming of the traditional network architecture. Furthermore, the VLC-PLC integration technology is applied to typical power grid business scene, which is substation intelligent inspection. The business process of master station platform is analyzed. During the intelligent inspection, the VLC-PLC system provides voice communication for on-site inspection personnel and management personnel, and position service. The system can ensure the safety and security of power production.展开更多
The length of data frame is an important parameter in Medium Access Control(MAC) layer protocol. A method of finding the optimal length of data frame when impulsive disturbance is involved in PowerLine Communications ...The length of data frame is an important parameter in Medium Access Control(MAC) layer protocol. A method of finding the optimal length of data frame when impulsive disturbance is involved in PowerLine Communications (PLC) is proposed. Having analyzed the characteristics of impulsive disturbance in powerline and the collision mechanism between the disturbance and data frame, this letter gives the function of the network channel utilization with the length of data frame in MAC layer and the impulsive disturbance. Our stochastic process simulation shows that it is feasible to get the optimal length of data frame.展开更多
With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With...With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With the continuous maturity of low-voltage power line communication (PLC), this leads us to see hopes of using PLC technology to realize remote meter reading. In this paper, based on current PLC technology and combining domestic and foreign successful cases, a beneficial exploration and research is conducted from the composition and establishment of software and the design of software and protocol.展开更多
In China there built a large scale of power line communication (Abbr. PLC) testing network. This paper presents the research and development on PLC technology in China and also the application and popularization of PL...In China there built a large scale of power line communication (Abbr. PLC) testing network. This paper presents the research and development on PLC technology in China and also the application and popularization of PLC in Chinese market. At the end, the next focal points of PLC technology research are deeply discussed.展开更多
This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-poin...This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-point digital signal processor (DSP) along with 4 MSPS analog-to-digital converter (ADC) is used to develop the intelligent electronic device. An optimized algorithm to process the analog signal in real-time and to extract the meaningful result using signal processing techniques has been implemented on the device. A laboratory environment has setup with all the necessary equipment including the development of the load model to evaluate the performance of the IED. Smart meter and concentrator is also connected to the low voltage (LV) network to monitor the PLC communication using the IED. The device has been tested in the laboratory and it has produced very promising results for time domain as well as frequency domain analysis. Those results imply that the IED is fully capable of monitoring high frequency disturbances in CENELEC PLC band.展开更多
文摘The low voltage powerline is becoming a powerful solution to home network, building automation, and internet access as a result of its wide distribution, easy access and little maintenance. The character of powerline channel is very complicated because it is an open net. This article analysed the character of the powerline channel,introduced the basics of OFDM(Orthogonal Frequency Division Multiplexing), and studied the OFDM applied into powerline high speed digital communication.
文摘In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate.
文摘Based on the experimental results, a simplified model for low-voltage powerline used as a high frequency communication channel is presented. With this model, the Orthogonal Frequency Division Multiplexing (OFDM) based high rate digital communication over low-voltage powerline is analyzed and simulated. The capability of the signal transmission system in overcoming multi-path interference and selection of the system parameters are discussed. And time-domain simulation is carried out to investigate the transmission capability of the OFDM communication system for different mapping schemes and transmission power levels. Simulation results show that it is possible to realize high rate digital communication over low-voltage powerline using OFDM when the transmitted power is large enough.
基金Supported by Headquarters Technology Project of State Grid Corporation of China(No.5700-202118203A-0-0-00)。
文摘Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference.
文摘The development trend of PLC is that the functions are more, the integration level is greater and the network function is greater. Nowadays, the manufacturers of PLC develop there own network. PLC technique has two development trends. On one hand, PLC network system is not a self-contained closed system any longer and develops towards open system. Various PLC not only has distinctive PLC network systems and completes device control task, but also network with the superior computer management system to realize information exchange, which makes it become one part of information management system. On the other hand, the field-bus technique is widely applied. PLC is connected with the intelligent equipments installed on site such as intelligent instrument, sensor, intelligent solenoid valve, intelligent drive actuator by a transmission media ( such as twisted pair, coaxial cable and cable), and they transmit information mutually according to the same communication protocol, which can form a field industrial control network. Compared with single PLC remote network, the network not only has the advantages of flexible configurations, easy expansion, low cost and higher cost perfomaance, but also has opening significance.
文摘Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.
文摘Noise characteristics of an indoor power line network strongly influence the link capability to achieve high data rates. The appliances shared with PLC modems in the same powerline network generate different types of noises, among them the impulsive noises are the main source of interference resulting in signal distortions and bit errors during data transmission. With regard to impulsive noise many models were proposed in the literature and shared the same impulsive noise definition: “unpredictable noises measured in the receiver side”. Authors are, consequently, confronted to model thousands of impulsive noises whose plurality would very likely come from the diversity of paths that the original impulsive noise took. In this paper, an innovative modelling approach is applied to impulsive noises which are studied here directly at their sources. Noise at receiver would be simply the noise model at source convolved by powerline channel block. In the new analytical model, the impulsive noise at source is described by a succession of short pulses, each modeled by a phase-shifted Gaussian. Noises at source are classified into 6 different classes [1], and a noise generator is established for each class.
基金the National Natural Science Foundation of China(No.60072048)
文摘This letter derives the Equivalent M-band Discrete Wavelet(EMDW) transmission mode of Orthogonal Frequency Division Multiplexing(OFDM) transmission systems, and presents a new Quadrature M-band Discrete Wavelet(QMDW) based OFDM-CDMA(Code Division Multiple Access) communication systems for high speed Power Line Communication (PLC) channels.This system gives much better robustness to Inter-Channel Interference (ICI), Multi-User Interference (MUI) and noise interference, which is verified by simulation.
文摘Power line communication (PLC) is a promising smart grid application for information transmission using existing power lines. We analytically model a finite-source PLC network subject to channel failure through a queueing theoretic framework. The proposed PLC network model consists of a base station (BS), which is located at a transformer station and connected to the backbone communication networks, and a number of subscriber stations that are interconnected with each other and with the BS via the power line transmission medium. An orthogonal frequency division multiplexing based technique is assumed for forming the transmission channels in a frequency spectrum. The channels are subject to failure during service due to noise. We determine the steady-state solution of the proposed model and derive a set of performance metrics of interest. Numerical and simulation results are presented to provide further insights into the analytical results. The proposed modeling method is expected to be used for evaluation and design of future PLC networks.
文摘Integrating the power grid technology with renewable power generation technologies, Demand Response (DR) programs enabled by the Advanced Metering Infrastructure (AMI) were introduced into the power grid in the interest of both utilities and residents. They help to achieve load balance and increase the grid reliability by encouraging residents to reduce their power usage during peak load periods in return for incentives. To automate this process, appliances, in-house sensors, and the AMI controller need to be networked together. In this paper, we compare mainstream network technologies applicable to home appliance control and propose a solution combining Power Line Communication (PLC) with wireless communication in smart homes for the purpose of energy saving. We extended NS-2, a popular network simulator, to model such combined network scenarios. Using a number of different routing strategies, we then model and evaluate the network performance of DR programs in smart homes in such a combined network.
文摘A kind of integrated network architecture visible light communication (VLC) and power line communication (PLC) is put forward. This architecture is low cost and easy to implement which overcomes the shortcoming of the traditional network architecture. Furthermore, the VLC-PLC integration technology is applied to typical power grid business scene, which is substation intelligent inspection. The business process of master station platform is analyzed. During the intelligent inspection, the VLC-PLC system provides voice communication for on-site inspection personnel and management personnel, and position service. The system can ensure the safety and security of power production.
文摘The length of data frame is an important parameter in Medium Access Control(MAC) layer protocol. A method of finding the optimal length of data frame when impulsive disturbance is involved in PowerLine Communications (PLC) is proposed. Having analyzed the characteristics of impulsive disturbance in powerline and the collision mechanism between the disturbance and data frame, this letter gives the function of the network channel utilization with the length of data frame in MAC layer and the impulsive disturbance. Our stochastic process simulation shows that it is feasible to get the optimal length of data frame.
文摘With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With the continuous maturity of low-voltage power line communication (PLC), this leads us to see hopes of using PLC technology to realize remote meter reading. In this paper, based on current PLC technology and combining domestic and foreign successful cases, a beneficial exploration and research is conducted from the composition and establishment of software and the design of software and protocol.
文摘In China there built a large scale of power line communication (Abbr. PLC) testing network. This paper presents the research and development on PLC technology in China and also the application and popularization of PLC in Chinese market. At the end, the next focal points of PLC technology research are deeply discussed.
文摘This paper proposes the design and development of a novel, portable and low-cost intelligent electronic device (IED) for real-time monitoring of high frequency phenomena in CENELEC PLC band. A high speed floating-point digital signal processor (DSP) along with 4 MSPS analog-to-digital converter (ADC) is used to develop the intelligent electronic device. An optimized algorithm to process the analog signal in real-time and to extract the meaningful result using signal processing techniques has been implemented on the device. A laboratory environment has setup with all the necessary equipment including the development of the load model to evaluate the performance of the IED. Smart meter and concentrator is also connected to the low voltage (LV) network to monitor the PLC communication using the IED. The device has been tested in the laboratory and it has produced very promising results for time domain as well as frequency domain analysis. Those results imply that the IED is fully capable of monitoring high frequency disturbances in CENELEC PLC band.