Chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol and 2,4, 6-trichlorophenol) may be presented in natural waters or drinking water as a result of disinfection processes involving ch...Chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol and 2,4, 6-trichlorophenol) may be presented in natural waters or drinking water as a result of disinfection processes involving chlorination, or as contaminants derived from domestic products, industrial operations and agricultural chemicals. A previous HPLC-UV method for determination of phenol and five chlorophenols in tap water using 4-fluoro-7-nitro-2,1,3-benzoxadiaole as a UV labeling reagent shows limited sensitivity. Here, we present an improved HPLC-fluorescence detection method for simultaneous determination of phenol and the above chlorophenols in tap water after pre-column derivatization with 3-chlorocarbonyl-6,7-dimethoxy-1-methyl-2(1H)-quino- xalinone (DMEQ-COCl), using a short, narrow column (50 × 2.1 mm i.d., packed with 5 μm particles of C18 material) to improve the sensitivity. Standard samples containing the compounds are derivatized with DMEQ-COCl in borate buffer (pH 9.0) at room temperature for 3 mins. The response is linear in the concentration range of 0.01 - 0.05 to 0.5 mg/L with r2 values ≥0.9967 for all compounds. The lower limits of detection are 0.001 to 0.008 mg/L, and the coefficients of variation are less than 8.8%. The recovery values from tap water spiked with standard samples are satisfactory. The present method is suitable for examining whether or not tap water samples are contaminated with phenol and chlorophenols in excess of regulatory values.展开更多
Raspberry ketone {RK, 4-(4-hydroxyphenyl)butan-2-one} is a natural compound contained in raspberry, and is added to cosmetics for skin whitening. It is very important to measure the RK level in cosmetics for quality a...Raspberry ketone {RK, 4-(4-hydroxyphenyl)butan-2-one} is a natural compound contained in raspberry, and is added to cosmetics for skin whitening. It is very important to measure the RK level in cosmetics for quality assessment, since RK structurally resembles 4-(4-hydroxyphenyl)-2-butanol, which causes leukoderma on consumers’ skin. Here, we present a simple HPLC-fluorescence method for determination of RK in a fragrance mist by pre-column derivatization with 4-hydrazino-7-nitro-2,1,3-benzoxadiazole hydrazine (NBD-H), which reacts with the carbonyl group of RK. The NBD-RK derivative was eluted from a reversed-phase ODS column, and detected with excitation at 470 nm and emission at 550 nm. The retention time of NBD-RK derivative obtained by reaction with NBD-H at 80°C for 20 min was 10.3 min. The standard curve was linear in the range of 0.2 to 10 μg/mL, with a correlation coefficient (r<sup>2</sup>) value of 0.9980. The lower limit of detection was 0.018 μg/mL (absolute amount of 1.8 pmol). The coefficients of variation were less than 8.1%. The content of RK in fragrance mist (1.00 mL) was 1.18 ± 0.07 mg (range: 1.12 to 1.28 mg, n = 5). Recovery tests were satisfactory (83.9% ± 3.9%;range: 79.6 to 88.8%, n = 5).展开更多
A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, trigly...A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, triglycine and glutathione were separated on a reversed-phase C-18 column with methanol-water-triethylamine eluent, derivatization and chromatographic conditions were optimized. The five derivatives were eluted in 28 min with a good reproducibility. Linear range of the calibration graph was 0.08-260 nmol/ml(-1). The relative standard deviations(n=6) are < 5%. Detection limits (signal-to-noise ratio=3) for the five derivatives are 20-40 fmol.展开更多
[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was ...[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was extracted using the wa- ter extraction method, further isolated and purified by DEAE cellulose-52 columns. The obtained tea polysaccharide and four components TPS1, TPS2, TPS3 and TPS, were first derived by 1-phenyl-3-methyl-5-pyrazolone (PMP), and then the PMP derivatives of monosaccharide were analyzed by high performance liquid chromatog- raphy (HPLC). [Result] Pu-erh tea polysaccharide contained eight kinds of monosac- chaddes (mannose, rhamnose, glucuronic acid, galacturonic acid, grucose, galactose, arabinose, fucose), without xylose; so it was the same with TPS1; each of TPS2, TPS3 and TPS4 contained seven monosaccharides, while no fucose. [Conclusion] This method is simplified and rapid, which can be used to determine the monosac- charide composition of Pu-erh tea polysaccharide and monosaccharide content.展开更多
A sensitive HPLC method for the detection of amino acids with pre-column fluorescence derivatization with carbazole-9-yl-acetyl chloride has been developed. This method, in conjunction with a multi-gradient program, o...A sensitive HPLC method for the detection of amino acids with pre-column fluorescence derivatization with carbazole-9-yl-acetyl chloride has been developed. This method, in conjunction with a multi-gradient program, offers baseline resolution of the common CRAC-amino acids from a linear acetonitrile gradient. Separation of amino acid derivatives was obtained on a reversed-phase C-18 column. Derivatization and chromatographic conditions were optimized. Amino acid derivatives were eluted in 40 min with good reproducibility. The relative standard deviations (n=6) at an analytical concentration of 100 pmol are < 4%. The methods described are also suitable for the analysis of amino acids in different biological samples.展开更多
Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new met...Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new method is described for the determination of sparfloxacin in human urine. The linear range is 0.05 mg/L to 4.0 mg/L, the recoveries are 91.5%similar to 95.7% and the RSD is 1.2%similar to4.2%. The results showed that this method is suitable for the determination of sparfloxacin in human urine.展开更多
A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were...A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.展开更多
High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral der...High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.展开更多
A simple vortex-assisted cloud-point extraction(VA-CPE)method combined with the fluorescence(FL)strategy was developed to extract and determine inorganic Se(IV)in environmental water.Toluene was used as an extraction ...A simple vortex-assisted cloud-point extraction(VA-CPE)method combined with the fluorescence(FL)strategy was developed to extract and determine inorganic Se(IV)in environmental water.Toluene was used as an extraction reagent,and Se(VI)was reduced to Se(IV)by subjecting its solution in 4 mol/L HCl to microwave heating for generating a yellow piazselenol complex using 3,3'-diaminobenzidine(DAB)and Se(IV).The concentration of the complex exhibited an excellent linear relation with the FL at 560 nm with an excitation wavelength of 420 nm.In addition,the effects of the toluene volume,pH,and VA-CPE parameters were investigated and the interference from coexisting ions was also studied.This method was successfully applied to determine the concentration selenium in environmental water samples with a detection limit of 0.05μg/L in the line range from 0.50μg/L to 50.00μg/L.展开更多
The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluoresce...The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (po- lymyxin E) has neither strong UV chromophore nor fluorophore. So, its assay for metabolism, pharmacokinetics studies for bioavailability and bioequivalence are difficult because of poor detectability. Therefore an enhanced UV or fluores-cence detection by chemical derivatization is required. MEKC-LIF method was proposed for colistin with a 488/520 nm argon-ion laser using a pre-CE derivatization with fluorescein isothiocyanate (FITC). Borate buffer was used as background buffer (BGB). The different parameters affecting the proposed derivatization reaction including concentration of the derivatizing reagent, reaction time and temperature were studied and optimized. The derivative was stable for up to 3 days. Different micelles (TX-100 and SDS) were examined as BGB additives separately but negative-charged mixed micelles (SDS/TX-100) were shown to be the best additive to BGB for the analysis of colistin particularly in human urine as they enhance both selectivity and sensitivity of the proposed method. BGB was used with pH 9.5, 10 kV, 8 s inj time, capillary length 75 cm × 75 μm ID (66 cm effective length), detection was LIF Ex 488 nm;Em 520 nm. The method was applied to colistin analysis in human urine and the recovery was > 98% (n = 5). LOD and LOQ in urine after pre-column derivatization using FITC were 100 and 250 ng/ml, respectively. Urine samples were analysed by direct injection without sample pre-treatment. The mechanism of enhancement of fluorescence of the derivative by surfactant was proposed.展开更多
文摘Chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol and 2,4, 6-trichlorophenol) may be presented in natural waters or drinking water as a result of disinfection processes involving chlorination, or as contaminants derived from domestic products, industrial operations and agricultural chemicals. A previous HPLC-UV method for determination of phenol and five chlorophenols in tap water using 4-fluoro-7-nitro-2,1,3-benzoxadiaole as a UV labeling reagent shows limited sensitivity. Here, we present an improved HPLC-fluorescence detection method for simultaneous determination of phenol and the above chlorophenols in tap water after pre-column derivatization with 3-chlorocarbonyl-6,7-dimethoxy-1-methyl-2(1H)-quino- xalinone (DMEQ-COCl), using a short, narrow column (50 × 2.1 mm i.d., packed with 5 μm particles of C18 material) to improve the sensitivity. Standard samples containing the compounds are derivatized with DMEQ-COCl in borate buffer (pH 9.0) at room temperature for 3 mins. The response is linear in the concentration range of 0.01 - 0.05 to 0.5 mg/L with r2 values ≥0.9967 for all compounds. The lower limits of detection are 0.001 to 0.008 mg/L, and the coefficients of variation are less than 8.8%. The recovery values from tap water spiked with standard samples are satisfactory. The present method is suitable for examining whether or not tap water samples are contaminated with phenol and chlorophenols in excess of regulatory values.
文摘Raspberry ketone {RK, 4-(4-hydroxyphenyl)butan-2-one} is a natural compound contained in raspberry, and is added to cosmetics for skin whitening. It is very important to measure the RK level in cosmetics for quality assessment, since RK structurally resembles 4-(4-hydroxyphenyl)-2-butanol, which causes leukoderma on consumers’ skin. Here, we present a simple HPLC-fluorescence method for determination of RK in a fragrance mist by pre-column derivatization with 4-hydrazino-7-nitro-2,1,3-benzoxadiazole hydrazine (NBD-H), which reacts with the carbonyl group of RK. The NBD-RK derivative was eluted from a reversed-phase ODS column, and detected with excitation at 470 nm and emission at 550 nm. The retention time of NBD-RK derivative obtained by reaction with NBD-H at 80°C for 20 min was 10.3 min. The standard curve was linear in the range of 0.2 to 10 μg/mL, with a correlation coefficient (r<sup>2</sup>) value of 0.9980. The lower limit of detection was 0.018 μg/mL (absolute amount of 1.8 pmol). The coefficients of variation were less than 8.1%. The content of RK in fragrance mist (1.00 mL) was 1.18 ± 0.07 mg (range: 1.12 to 1.28 mg, n = 5). Recovery tests were satisfactory (83.9% ± 3.9%;range: 79.6 to 88.8%, n = 5).
文摘A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, triglycine and glutathione were separated on a reversed-phase C-18 column with methanol-water-triethylamine eluent, derivatization and chromatographic conditions were optimized. The five derivatives were eluted in 28 min with a good reproducibility. Linear range of the calibration graph was 0.08-260 nmol/ml(-1). The relative standard deviations(n=6) are < 5%. Detection limits (signal-to-noise ratio=3) for the five derivatives are 20-40 fmol.
基金Supported by National Key Technologies R & D Program(2007BAD58B03)~~
文摘[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was extracted using the wa- ter extraction method, further isolated and purified by DEAE cellulose-52 columns. The obtained tea polysaccharide and four components TPS1, TPS2, TPS3 and TPS, were first derived by 1-phenyl-3-methyl-5-pyrazolone (PMP), and then the PMP derivatives of monosaccharide were analyzed by high performance liquid chromatog- raphy (HPLC). [Result] Pu-erh tea polysaccharide contained eight kinds of monosac- chaddes (mannose, rhamnose, glucuronic acid, galacturonic acid, grucose, galactose, arabinose, fucose), without xylose; so it was the same with TPS1; each of TPS2, TPS3 and TPS4 contained seven monosaccharides, while no fucose. [Conclusion] This method is simplified and rapid, which can be used to determine the monosac- charide composition of Pu-erh tea polysaccharide and monosaccharide content.
文摘A sensitive HPLC method for the detection of amino acids with pre-column fluorescence derivatization with carbazole-9-yl-acetyl chloride has been developed. This method, in conjunction with a multi-gradient program, offers baseline resolution of the common CRAC-amino acids from a linear acetonitrile gradient. Separation of amino acid derivatives was obtained on a reversed-phase C-18 column. Derivatization and chromatographic conditions were optimized. Amino acid derivatives were eluted in 40 min with good reproducibility. The relative standard deviations (n=6) at an analytical concentration of 100 pmol are < 4%. The methods described are also suitable for the analysis of amino acids in different biological samples.
文摘Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new method is described for the determination of sparfloxacin in human urine. The linear range is 0.05 mg/L to 4.0 mg/L, the recoveries are 91.5%similar to 95.7% and the RSD is 1.2%similar to4.2%. The results showed that this method is suitable for the determination of sparfloxacin in human urine.
基金Supported by Open Project of the Key Laboratory of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base(201603)Basic Research Project of Application of Suzhou City(SNG201622)
文摘A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.
文摘High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.
基金Scientific Research Staring Foundation for the Returned Overseas Chinese Scholars,Ministry of Education of China(No.[2015] 1098)Cooperation of Production and Research Foundation of Science and Technology Bureau in Yulin,Shaanxi Province,China(No.2016CXY-02)+1 种基金Key Science and Technology of Program of Shaanxi Province,China(No.2017GY-131)Foundation of Yulin University for the Introduction of Talents,China(Nos.14GK23,17GK15)
文摘A simple vortex-assisted cloud-point extraction(VA-CPE)method combined with the fluorescence(FL)strategy was developed to extract and determine inorganic Se(IV)in environmental water.Toluene was used as an extraction reagent,and Se(VI)was reduced to Se(IV)by subjecting its solution in 4 mol/L HCl to microwave heating for generating a yellow piazselenol complex using 3,3'-diaminobenzidine(DAB)and Se(IV).The concentration of the complex exhibited an excellent linear relation with the FL at 560 nm with an excitation wavelength of 420 nm.In addition,the effects of the toluene volume,pH,and VA-CPE parameters were investigated and the interference from coexisting ions was also studied.This method was successfully applied to determine the concentration selenium in environmental water samples with a detection limit of 0.05μg/L in the line range from 0.50μg/L to 50.00μg/L.
文摘The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (po- lymyxin E) has neither strong UV chromophore nor fluorophore. So, its assay for metabolism, pharmacokinetics studies for bioavailability and bioequivalence are difficult because of poor detectability. Therefore an enhanced UV or fluores-cence detection by chemical derivatization is required. MEKC-LIF method was proposed for colistin with a 488/520 nm argon-ion laser using a pre-CE derivatization with fluorescein isothiocyanate (FITC). Borate buffer was used as background buffer (BGB). The different parameters affecting the proposed derivatization reaction including concentration of the derivatizing reagent, reaction time and temperature were studied and optimized. The derivative was stable for up to 3 days. Different micelles (TX-100 and SDS) were examined as BGB additives separately but negative-charged mixed micelles (SDS/TX-100) were shown to be the best additive to BGB for the analysis of colistin particularly in human urine as they enhance both selectivity and sensitivity of the proposed method. BGB was used with pH 9.5, 10 kV, 8 s inj time, capillary length 75 cm × 75 μm ID (66 cm effective length), detection was LIF Ex 488 nm;Em 520 nm. The method was applied to colistin analysis in human urine and the recovery was > 98% (n = 5). LOD and LOQ in urine after pre-column derivatization using FITC were 100 and 250 ng/ml, respectively. Urine samples were analysed by direct injection without sample pre-treatment. The mechanism of enhancement of fluorescence of the derivative by surfactant was proposed.