Management of Severe Femoral Bone Defect in Revision Total Hip Arthroplasty-A 236 Hip,6-14-year Follow-up Study 被引量:4
1
作者 张国强 王岩 +5 位作者 陈继营 周勇刚 曹秀堂 柴伟 倪明 李想 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第4期606-610,共5页
Summary: This study evaluated the clinical effect of impaction bone graft and distal press-fit fixation for the reconstruction of severe femoral bone defect in revision total hip arthroplasty. A total of 234 patients... Summary: This study evaluated the clinical effect of impaction bone graft and distal press-fit fixation for the reconstruction of severe femoral bone defect in revision total hip arthroplasty. A total of 234 patients (involving 236 hips) with Paprosky III and 1V femoral bone defects were treated with the revision total hip arthroplasty from June 1998 to Aug. 2006. Impaction bone graft technique was used for 112 hips, with allogeneic freeze-dried bone as bone graft and SP II as prosthesis. With 124 hips, modular distal press-fit fixation and tapered femoral stem (MP stem) were employed. After the operation, the subjects were followed up on regular basis and results were assessed by using the Harris Hip Score (HHS) and 12-item Short Form Health Survey (SF-12). Radiolucence, subsidence and loosening were observed and complications, including infection, fracture, dislocation etc. were recorded. A 6-14-year follow-up showed that prostheses failed, due to infection, in 4 patients of impaction bone graft group and that 6 patients in the press-fit fixation group experienced prosthesis failure, with the survival rates for the two techniques being 96.43% and 95.16%, respectively. One-way ANOVA showed that prosthesis survival was significantly associated with surgery-related complications (P〈0.05) and was not related to the type of the bone defects (P〉0.05). The rate of complications bore significant association with the type of bone defects in the two groups (P〈0.05). Our study showed that the two revision methods could achieve satisfactory mid-term and long-term results for the reconstruction of severe bone defects. It is of great significance for attaining high prosthesis survival rate to select suitable operation on the basis of the type of bone defect. Careful operative manipulation and post-operative rehabilitation aimed at reducing complications are also important. 展开更多
关键词 revision total hip arthroplasty bone defects press-fit fixation
下载PDF
基于磁机械效应的列车轮对勒伤检测方法
2
作者 邓远辉 陈钘 +1 位作者 李路明 杨德智 《无损检测》 北大核心 2007年第6期301-303,364,共4页
轮对的勒伤缺陷对火车的运行安全危害严重。提出了基于微磁的检测方法,分析了磁机械效应原理,试验研究了列车轮对勒伤部位因应力集中导致的磁场分布变化,研制了勒伤检测仪。实验研究表明,该方法对勒伤缺陷十分敏感,具有良好的检测效果。
关键词 磁机械效应 磁场分布 应力集中 勒伤 列车轮对
下载PDF
压装车轴镶入部裂纹缺陷信息提取
3
作者 武冬冬 杨凯 彭朝勇 《中国铁道科学》 EI CAS CSCD 北大核心 2021年第3期121-126,共6页
针对轨道车辆压装车轴镶入部在定期超声波检测时噪声信号幅值较大、缺陷信号被淹没在噪声信号中无法直接识别的状况,基于超声波检测信号采集数据分析信号典型特征,结果表明有较高辨识度的缺陷信号具有能量集中、信噪比高且快速收敛的特... 针对轨道车辆压装车轴镶入部在定期超声波检测时噪声信号幅值较大、缺陷信号被淹没在噪声信号中无法直接识别的状况,基于超声波检测信号采集数据分析信号典型特征,结果表明有较高辨识度的缺陷信号具有能量集中、信噪比高且快速收敛的特性。采用小包波变换对采集的压装后的车轴镶入部超声波检测信号进行分解,提取区别于噪声信息的缺陷特征系数和缺陷幅值系数,以此重建信号波形;再采用基于logistic函数的自寻优阈值滤波改进算法提高缺陷信号信噪比,以检测淹没在噪声信号中的缺陷信号,并基于神经网络进行验证。结果表明:基于缺陷特征系数和缺陷幅值系数的重建信号波形,可以准确区分超声波检测数据中噪声信号和含有疲劳裂纹的缺陷信号,对于缺陷深度大于0.5 mm的裂纹缺陷,识别准确率为100%。 展开更多
关键词 无损检测 信息提取 压装车轴 裂纹缺陷 超声波 神经网络