Implementation of a Multi-sampling-frequency System for RR-interval Timing and Blood Pressure Detection
1
作者 XU Liang FAN Bao-lin +1 位作者 WANG Xing PENG Yi 《Chinese Journal of Biomedical Engineering(English Edition)》 2006年第4期151-158,共8页
In order to analyze the experimental cardiovascular signal with high accuracy, a system, integrating real-time monitoring and off-line further analysis, was developed and verified. The design, data processing and anal... In order to analyze the experimental cardiovascular signal with high accuracy, a system, integrating real-time monitoring and off-line further analysis, was developed and verified. The design, data processing and analysis methods as well as testing results are described. With 5 sampling frequency choices and 8 channel data acquisition, the system achieved high performances in beat-to-beat monitoring, signal processing and analysis. Tests were carried out to validate its performance in real-time monitoring, effectiveness of digital filters, QRS and blood pressure detection reliability, and RR-interval timing accuracy. The QRS detection rate was at least 99.46% for the records with few noises from MIT-BIH arrhythmia database using the algorithm for real-time monitoring, and no less than 96.43% for the records with some noises. In the condition that noise amplitude levels were less than 80%,the standard deviations for RR-interval timing were less than 1 ms with a generated ECG corrupted with various noises from MIT-BIH Noise Stress Test Database. Besides, the system is open for function expansion to meet further study-specific needs. 展开更多
关键词 Experimental cardiovascular data Beat-to-beat detection ECG signal processing RR-interval timing accuracy Blood pressure detection
下载PDF
Higher resolution helium measuring system for deuterium plasma on EAST tokamak via normal Penning gauge
2
作者 王厚银 胡建生 +4 位作者 余耀伟 曹斌 吴金华 沈国清 万朝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第1期90-96,共7页
Although the deuterium and helium have almost the same mass,a Penning Optical Gas Analyzer(POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST,since 2014.The POGA ... Although the deuterium and helium have almost the same mass,a Penning Optical Gas Analyzer(POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST,since 2014.The POGA system was developed successfully in 2015,it was the first time that EAST could detect helium partial pressure in deuterium plasma(wall conditioning and plasma operation scenario).With dedicated calibration and proper adjustment of the parameters,the minimum concentration of helium in deuterium gas can be measured as about 0.5% instead of 1% on the other tokamak devices.Moreover,the He and D2 partial pressures are measured simultaneously.At present,the measurable range of deuterium partial pressure is 1×10^-7 mbar to 1×10^-5mbar,meanwhile the range of helium is 1×10^-8 mbar to 1×10^-5 mbar.The measurable range can be modified by means of the adjustment of POGA system's parameters.It is possible to detect the interesting part of the gas with a time resolution of less than 5 ms(the 200 ms because of conductance of transfer pipe at present).The POGA system was routinely employed to wall conditioning and helium enrichment investigation in2015.Last but not the least,the low temperature plasma of POGA is generated by normal penning gauge Pfeiffer IKR gauge instead of Alcatel CF2 P,which has been suspended for a few years and was used for almost all the POGA systems in the world. 展开更多
关键词 penning discharge helium pressure detecting low temperature plasma PMT IKR 251 gauge
下载PDF
Graphene aerogel-based vibration sensor with high sensitivity and wide frequency response range
3
作者 Zibo Wang Zhuojian Xiao +6 位作者 Jie Mei Yanchun Wang Xiao Zhang Xiaojun Wei Huaping Liu Sishen Xie Weiya Zhou 《Nano Research》 SCIE EI CSCD 2023年第8期11342-11349,共8页
Compared with piezoresistive sensors,pressure sensors based on the contact resistance effect are proven to have higher sensitivity and the ability to detect ultra-low pressure,thus attracting extensive research intere... Compared with piezoresistive sensors,pressure sensors based on the contact resistance effect are proven to have higher sensitivity and the ability to detect ultra-low pressure,thus attracting extensive research interest in wearable devices and artificial intelligence systems.However,most studies focus on static or low-frequency pressure detection,and there are few reports on high-frequency dynamic pressure detection.Limited by the viscoelasticity of polymers(necessary materials for traditional vibration sensors),the development of vibration sensors with high frequency response remains a great challenge.Here,we report a graphene aerogel-based vibration sensor with higher sensitivity and wider frequency response range(2 Hz–10 kHz)than both conventional piezoresistive and similar sensors.By modulating the microscopic morphology and mechanical properties,the super-elastic graphene aerogels suitable for vibration sensing have been prepared successfully.Meanwhile,the mechanism of the effect of density on the vibration sensor’s sensitivity is studied in detail.On this basis,the sensitivity,signal fidelity and signal-to-noise ratio of the sensor are further improved by optimizing the structure configuration.The developed sensor exhibits remarkable repeatability,excellent stability,high resolution(0.0039 g)and good linearity(non-linearity error<0.8%)without hysteresis.As demos,the sensor can not only monitor low-frequency physiological signals and motion of the human body,but also respond to the high-frequency vibrations of rotating machines.In addition,the sensor can also detect static pressure.We expect the vibration sensor to meet a wider range of functional needs in wearable devices,smart robots,and industrial equipment. 展开更多
关键词 vibration sensor graphene aerogel high frequency vibration dynamic pressure detection mechanical property
原文传递