Based on the durability characteristics of prestressed concrete structures,the durability limit states of carbonation and chloride ion attack are defined, respectively.Durability predicting models on the basis of reli...Based on the durability characteristics of prestressed concrete structures,the durability limit states of carbonation and chloride ion attack are defined, respectively.Durability predicting models on the basis of reliability mathematics and stochastic processes areconstructed, and the pure theoretical formulae of failure probability of prestressed concretestructures are analyzed. In addition, a simple durability design method for carbonation ofstructures is put forward. According to the analysis, the durability of prestressed concretestructures is superior to that of traditional structures. The research also indicates that theconcrete cover prescribed in the current code (GB 50010-2002) is not adequate. The rational coverthickness should notbe less than 35 or 45 mm according to carbonation or chloride ion attack,respectively.展开更多
Like reinforced concrete (RC) structure, Prestressed concrete (PC) structures cannot escape from corrosion related problems, especially when they are subjected to very aggressive environment, such as chloride envi...Like reinforced concrete (RC) structure, Prestressed concrete (PC) structures cannot escape from corrosion related problems, especially when they are subjected to very aggressive environment, such as chloride environment. The corrosion of PC and RC structures can take place if the concrete quality is not adequate, the concrete cover is less than that specified in the design, poor detailing during design and construction. For RC structures, corrosion in the reinforcing steel generally leads to serviceability problems (staining, cracking and spalling of concrete). By contrast, for PC structures, corrosion of prestressing strands may initiate structural collapse due to higher stress levels in the steel and smaller diameter of the prestressing steel. Research on corrosion effect on concrete structure has mainly considered the effect of corrosion have on reinforced and full prestressed concrete structure. In this study, a structural framework will be developed to predict the flexural strength of partial prestressed concrete structures in a chloride environment. The corrosion model previously developed for reinforced and prestressed concrete structures will be combined to predict the effect of corrosion has on partial prestressed concrete structures. Note that in partial prestressed concrete structures, both non prestressing steel (passive) and prestressing (active) reinforcement are utilized to carry the load. The framework developed will be combined with probability analysis to take into account the variability of parameters influencing the corrosion process. This approach allows more accurate prediction of service life of partial prestressed concrete structures in a chloride environment.展开更多
The seismic performances of the large-span prestressed concrete frame structure of bunker bay of thermal power plant under different intensity level was investigated by shaking table tests.A 1/8 microconcrete nonfull ...The seismic performances of the large-span prestressed concrete frame structure of bunker bay of thermal power plant under different intensity level was investigated by shaking table tests.A 1/8 microconcrete nonfull weight scaled model was designed according to the prototype structure and the conditions of laboratory.Three kinds of scaled ground motion accelerations were employed as seismic excitations.White noise was input in the structure through each seismic wave applied.The experimental results indicate that the structure is safe to endure seven degree intensity as required in Chinese codes.The natural vibration frequency of the structure is decreasing with the increasing of the seismic intensity,the natural vibration frequency of the structure decreases by about 24.5%,and the structural stiffness reduces by nearly 44% in seven degree intensity of seldom occurred earthquake.The damage at the top of column in the first floor is the most serious,the weak part of the structure is at the first floor,and the strong beam/weak column phenomenon appeared obviously,so this kind of large-span prestressed concrete frame should not be used in a high intensity district.展开更多
文摘Based on the durability characteristics of prestressed concrete structures,the durability limit states of carbonation and chloride ion attack are defined, respectively.Durability predicting models on the basis of reliability mathematics and stochastic processes areconstructed, and the pure theoretical formulae of failure probability of prestressed concretestructures are analyzed. In addition, a simple durability design method for carbonation ofstructures is put forward. According to the analysis, the durability of prestressed concretestructures is superior to that of traditional structures. The research also indicates that theconcrete cover prescribed in the current code (GB 50010-2002) is not adequate. The rational coverthickness should notbe less than 35 or 45 mm according to carbonation or chloride ion attack,respectively.
文摘Like reinforced concrete (RC) structure, Prestressed concrete (PC) structures cannot escape from corrosion related problems, especially when they are subjected to very aggressive environment, such as chloride environment. The corrosion of PC and RC structures can take place if the concrete quality is not adequate, the concrete cover is less than that specified in the design, poor detailing during design and construction. For RC structures, corrosion in the reinforcing steel generally leads to serviceability problems (staining, cracking and spalling of concrete). By contrast, for PC structures, corrosion of prestressing strands may initiate structural collapse due to higher stress levels in the steel and smaller diameter of the prestressing steel. Research on corrosion effect on concrete structure has mainly considered the effect of corrosion have on reinforced and full prestressed concrete structure. In this study, a structural framework will be developed to predict the flexural strength of partial prestressed concrete structures in a chloride environment. The corrosion model previously developed for reinforced and prestressed concrete structures will be combined to predict the effect of corrosion has on partial prestressed concrete structures. Note that in partial prestressed concrete structures, both non prestressing steel (passive) and prestressing (active) reinforcement are utilized to carry the load. The framework developed will be combined with probability analysis to take into account the variability of parameters influencing the corrosion process. This approach allows more accurate prediction of service life of partial prestressed concrete structures in a chloride environment.
基金Supported by the National Natural Science Foundation of China (50878172)the Scientific Research Foundation for the Returned Overseas Chinese Scholars of Ministry of Education of China (20083j0012)
文摘The seismic performances of the large-span prestressed concrete frame structure of bunker bay of thermal power plant under different intensity level was investigated by shaking table tests.A 1/8 microconcrete nonfull weight scaled model was designed according to the prototype structure and the conditions of laboratory.Three kinds of scaled ground motion accelerations were employed as seismic excitations.White noise was input in the structure through each seismic wave applied.The experimental results indicate that the structure is safe to endure seven degree intensity as required in Chinese codes.The natural vibration frequency of the structure is decreasing with the increasing of the seismic intensity,the natural vibration frequency of the structure decreases by about 24.5%,and the structural stiffness reduces by nearly 44% in seven degree intensity of seldom occurred earthquake.The damage at the top of column in the first floor is the most serious,the weak part of the structure is at the first floor,and the strong beam/weak column phenomenon appeared obviously,so this kind of large-span prestressed concrete frame should not be used in a high intensity district.