The concepts of entransy flux and entransy dissipation in radiative heat transfer were introduced based on the analogy with heat conduction and heat convection processes. Entransy will be partially dissipated during t...The concepts of entransy flux and entransy dissipation in radiative heat transfer were introduced based on the analogy with heat conduction and heat convection processes. Entransy will be partially dissipated during the radiative heat transfer processes due to the irreversibility. The extremum principle of entransy dissipation was developed for optimizing radiative heat transfer processes. This principle states that for a fixed boundary temperature the radiative heat transfer is optimized when the entransy dissipation is maximized, while for a fixed boundary heat flux the radiative heat transfer process is optimized when the entransy dissipation is minimized. Finally, examples for the application of the entransy dissipation extre- mum principle are presented.展开更多
The entransy dissipation extremum principle provides new warranty and criterion for optimization of heat transfer.For two cases(body with heat generation and body heated externally)of a solid conducting wall with an o...The entransy dissipation extremum principle provides new warranty and criterion for optimization of heat transfer.For two cases(body with heat generation and body heated externally)of a solid conducting wall with an open cavity,a dimensionless equivalent thermal resistance based on entransy dissipation definition was taken as the optimization objective to optimize the model constructal ge- ometry.Numerical results validated the necessity and feasibility of the presented method.Comparisons of the numerical results based on minimization of dimensionless maximum thermal resistance and minimization of dimensionless equivalent thermal resistance,respectively,showed that there was no obvious difference between the two results when the volume fractionΦoccupied by cavity was small, but the difference between the two results increased with the increases ofΦand the body aspect ratio H/L for any model.The optimal cavities for bodies heated externally were more slender than those for bodies with heat generation.Heat origin had obvious effect on the global performance of heat transfer. The entransy dissipation of body heated externally increased 2―3 times than that of body with heat generation,indicating that the global performance of heat transfer weakened.The method presented herein provides some guidelines for some relevant thermal design problems.展开更多
The constructal optimizations of T-shaped fin with two-dimensional heat transfer model are carried out by finite element method and taking the minimization of equivalent thermal resistance based on entransy dissipatio...The constructal optimizations of T-shaped fin with two-dimensional heat transfer model are carried out by finite element method and taking the minimization of equivalent thermal resistance based on entransy dissipation and the minimization of maximum thermal resistance as optimization objectives, respectively. The effects of the global parameter a (integrating the coefficient of convective heat transfer, the overall area occupied by fin and its thermal conductivity) and the volume fraction ? of fin on the minimums of equivalent thermal resistance and maximum thermal resistance as well as their corresponding optimal configurations are analyzed. The comparison of the results based on the above two optimization objectives is conducted. The results show that the optimal structures based on the two optimization objectives are obviously different from each other. Compared with the optimization result by taking the minimization of maximum thermal resistance as the objective, the optimization result by taking the equivalent thermal resistance minimization as the objective can reduce the average temperature difference in the fin obviously. The increases of a and ? can all improve the working status of local hot spot and the global heat transfer performance of the system. But the improvement effects of the increases of a and ? on the minimization of equivalent thermal resistance are different from those on the minimization of maximum thermal resistance. For either objective, the effect of a is different from that of ?. The T-shaped fin with minimum equivalent thermal resistance is much taller than that with minimum maximum thermal resistance; for either optimization objective, the stem of fin is thicker than the branches of fin, and the stem thickness is relatively close to branch thickness when the minimization of equivalent thermal resistance is taken as the optimization objective. The T-shaped fin with flat stem and slender branches can benefit the reduction of the maximum thermal resistance.展开更多
Heat exchanger network optimization has an important role in high-efficiency energy utilization and energy conservation. The thermal resistance of a heat exchanger network is defined based on its entransy dissipation....Heat exchanger network optimization has an important role in high-efficiency energy utilization and energy conservation. The thermal resistance of a heat exchanger network is defined based on its entransy dissipation. In two-stream heat exchanger networks, only heat exchanges between hot and cold fluids are considered. Thermal resistance analysis indicates that the maximum heat transfer rate between two fluids corresponds to the minimum entransy-dissipation-based thermal resistance; i.e. the minimum thermal resistance principle can be exploited in optimizing heat exchanger networks.展开更多
Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mas...Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mass flow rate of gas and the maximum entransy dissipation rate all depend on the dimensionless diameter of one tube,the dimensionless pressure difference number and the dimensionless length of flow channel of gas.Besides the three dimensionless groups,the optimal numbers of riser tubes and downcomer tubes and their summation all depend on the dimensionless height of one tube.The maximum entransy dissipation rate increases as the pressure difference that drives the gas flowing increases,and as the diameter of one tube and the length of flow channel both decrease.The mean heat flux in the heat transfer process of hot gas grows greatly,and the performance of the system is improved.Compared with the optimal construct with heat transfer rate maximization,the optimal construct with entransy dissipation rate maximization can improved the heat transfer effect of the steam generator more.展开更多
Analogizing with the heat conduction process, the entransy dissipation extremum principle for thermal insulation process can be described as: for a fixed boundary heat flux (heat loss) with certain constraints, the th...Analogizing with the heat conduction process, the entransy dissipation extremum principle for thermal insulation process can be described as: for a fixed boundary heat flux (heat loss) with certain constraints, the thermal insulation process is optimized when the entransy dissipation is maximized (maximum average temperature difference), while for a fixed boundary temperature, the thermal insulation process is optimized when the entransy dissipation is minimized (minimum average heat loss rate). Based on the constructal theory, the constructal optimizations of a single plane and cylindrical insulation layers as well as multi-layer insulation layers of the steel rolling reheating furnace walls are carried out for the fixed boundary temperatures and by taking the minimization of entransy dissipation rate as optimization objective. The optimal constructs of these three kinds of insulation structures with distributed thicknesses are obtained. The results show that compared with the insulation layers with uniform thicknesses and the optimal constructs of the insulation layers obtained by minimum heat loss rate, the optimal constructs of the insulation layers obtained by minimum entransy dissipation rate are obviously different from those of the former two insulation layers; the optimal constructs of the insulation layers obtained by minimum entransy dissipation rate can effectively reduce the average heat loss rates of the insulation layers, and can help to improve their global thermal insulation performances. The entransy dissipation extremum principle is applied to the constructal optimizations of insulation systems, which will help to extend the application range of the entransy dissipation extremum principle.展开更多
For distribution optimization of the flow rate of cold fluid and heat transfer area in the parallel thermal network of the thermal control system in spacecraft,a physical and mathematical model is set up,analyzed and ...For distribution optimization of the flow rate of cold fluid and heat transfer area in the parallel thermal network of the thermal control system in spacecraft,a physical and mathematical model is set up,analyzed and discussed with the entransy theory.It is found that the optimization objective of this problem and the optimization direction of the extremum entransy dissipation principle are consistent in theory.For a two-branch thermal network system,the distributions of the flow rate of the cold fluid and the heat transfer area are optimized by calculating the extremum entransy dissipation with the Newton method.The influential factors of the optimized distributions are also analyzed and discussed.The results show that the main influence factors are the heat transfer rate of the branches and the total heat transfer area.The total flow rate of the cold fluid has a threshold,beyond which further increasing its value brings very little influence on the optimization results.Moreover,the difference between the extremum entransy dissipation principle and the minimum entropy generation principle is also discussed when they are used to analyze the problem in this paper,and the extremum entransy dissipation principle is found to be more suitable.In addition,the Newton method is mathematically efficient to solve the problem,which could accomplish the optimized distribution in a very short time for a ten-branch thermal network system.展开更多
The uniformity principle of temperature difference field is a phenomenological principle,which has not been theoretically proved.For one-dimensional two-and three-stream heat exchangers,the extremum principle of entra...The uniformity principle of temperature difference field is a phenomenological principle,which has not been theoretically proved.For one-dimensional two-and three-stream heat exchangers,the extremum principle of entransy dissipation was used to optimize the heat transfer process by variational calculus.It was indicated that the temperature difference field between the hot and cold fluids should be completely uniform if the entransy dissipation reached a minimum for a given heat duty,or if the heat duty reached a maximum for a given entransy dissipation.So,the uniformity principle of temperature difference field of heat exchangers was primarily proved.展开更多
The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar c...The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar collectors with different length and diameter tubes, different coating materials, and with / without guide plates, respectively. Threedimensional mathematical models on natural and forced convections in the solar collectors are established and the experimental data is validated by field synergy and entransy principles. The results of natural convection show that the water temperature increases and thermal efficiency decreases gradually with the evacuated tube length. The thermal efficiency increases when absorption rates increase from 0. 95 to 1. 0 and emission rates decrease from 0. 16 to 0. 06. The thermal efficiency of solar collectors is increased after being equipped with the guide plate, which is attributed to the disappearance of the mixed flowand the enhancement of the heat transfer at the bottom of the evacuated tube. The results of forced convertion indicate that the Reynolds, Nusselt and entransy increments of the horizontal double collectors are higher than those of the vertical single collector while the entransy dissipation is lower than that of the vertical single collector. It is concluded that the solar collectors with guide plates are suitable for natural convection while the double horizontal collectors are suitable for forced convection in the thermal field of solar-assisted fuel cell systems with lowand medium temperatures.展开更多
This review paper summarizes constructal design progress performed by the authors for eight types of heat sinks with ten performance indexes being taken as the optimization objectives,respectively,by combining the met...This review paper summarizes constructal design progress performed by the authors for eight types of heat sinks with ten performance indexes being taken as the optimization objectives,respectively,by combining the methods of theoretical analysis and numerical calculation.The eight types of heat sinks are uniform height rectangular fin heat sink,non-uniform height rectangular fin heat sink,inline cylindrical pin-fin heat sink(ICPHS),plate single-row pin fin heat sink(PSRPHS),plate inline pin fin heat sink(PIPHS),plate staggered pin fin heat sink(PSPHS),single-layered microchannel heat sink(SLMCHS)with rectangular cross sections and double-layered microchannel heat sink(DLMCHS)with rectangular cross sections,respectively.And the ten performance indexes are heat transfer rate maximization,maximum thermal resistance minimization,minimization of equivalent thermal resistance which is defined based on the entransy dissipation rate(equivalent thermal resistance for short),field synergy number maximization,entropy generation rate minimization,operation cost minimization,thermo-economic function value minimization,pressure drop minimization,enhanced heat transfer factor maximization and efficiency evaluation criterion number maximization,respectively.The optimal constructs of the eight types of heat sinks with different constraints and based on the different optimization objectives are compared with each other.The results indicated that the optimal constructs mostly are different based on different optimization objectives under the same boundary condition.The optimization objective should be suitable chosen based on the focus when the constructal design for one heat sink is performed.The results obtained herein have some important theoretical significances and application values,and can provide scientific bases and theoretical guidelines for the thermal design of real heat sinks and their applications.展开更多
基金Supported by the National Basic Research Program of China ("973" Project) (Grant No. 2007CB206901)
文摘The concepts of entransy flux and entransy dissipation in radiative heat transfer were introduced based on the analogy with heat conduction and heat convection processes. Entransy will be partially dissipated during the radiative heat transfer processes due to the irreversibility. The extremum principle of entransy dissipation was developed for optimizing radiative heat transfer processes. This principle states that for a fixed boundary temperature the radiative heat transfer is optimized when the entransy dissipation is maximized, while for a fixed boundary heat flux the radiative heat transfer process is optimized when the entransy dissipation is minimized. Finally, examples for the application of the entransy dissipation extre- mum principle are presented.
基金Supported by the Program for New Century Excellent Talents in Universities of China(Grant No.20041006)the Foundation for the Authors of National Excellent Doctoral Dissertation of China(Grant No.200136)
文摘The entransy dissipation extremum principle provides new warranty and criterion for optimization of heat transfer.For two cases(body with heat generation and body heated externally)of a solid conducting wall with an open cavity,a dimensionless equivalent thermal resistance based on entransy dissipation definition was taken as the optimization objective to optimize the model constructal ge- ometry.Numerical results validated the necessity and feasibility of the presented method.Comparisons of the numerical results based on minimization of dimensionless maximum thermal resistance and minimization of dimensionless equivalent thermal resistance,respectively,showed that there was no obvious difference between the two results when the volume fractionΦoccupied by cavity was small, but the difference between the two results increased with the increases ofΦand the body aspect ratio H/L for any model.The optimal cavities for bodies heated externally were more slender than those for bodies with heat generation.Heat origin had obvious effect on the global performance of heat transfer. The entransy dissipation of body heated externally increased 2―3 times than that of body with heat generation,indicating that the global performance of heat transfer weakened.The method presented herein provides some guidelines for some relevant thermal design problems.
基金supported by the National Natural Science Foundation of China (Grant No. 10905093)the Program for New Century Excellent Talents in University of China (Grant No. NCET-04-1006)+1 种基金the Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No. 200136)the Natural Science Foundation for Youngsters of Naval University of Engineering (Grant No. HGDQNJJ10017)
文摘The constructal optimizations of T-shaped fin with two-dimensional heat transfer model are carried out by finite element method and taking the minimization of equivalent thermal resistance based on entransy dissipation and the minimization of maximum thermal resistance as optimization objectives, respectively. The effects of the global parameter a (integrating the coefficient of convective heat transfer, the overall area occupied by fin and its thermal conductivity) and the volume fraction ? of fin on the minimums of equivalent thermal resistance and maximum thermal resistance as well as their corresponding optimal configurations are analyzed. The comparison of the results based on the above two optimization objectives is conducted. The results show that the optimal structures based on the two optimization objectives are obviously different from each other. Compared with the optimization result by taking the minimization of maximum thermal resistance as the objective, the optimization result by taking the equivalent thermal resistance minimization as the objective can reduce the average temperature difference in the fin obviously. The increases of a and ? can all improve the working status of local hot spot and the global heat transfer performance of the system. But the improvement effects of the increases of a and ? on the minimization of equivalent thermal resistance are different from those on the minimization of maximum thermal resistance. For either objective, the effect of a is different from that of ?. The T-shaped fin with minimum equivalent thermal resistance is much taller than that with minimum maximum thermal resistance; for either optimization objective, the stem of fin is thicker than the branches of fin, and the stem thickness is relatively close to branch thickness when the minimization of equivalent thermal resistance is taken as the optimization objective. The T-shaped fin with flat stem and slender branches can benefit the reduction of the maximum thermal resistance.
基金supported by the National Basic Research Program of China (G2007CB206901)
文摘Heat exchanger network optimization has an important role in high-efficiency energy utilization and energy conservation. The thermal resistance of a heat exchanger network is defined based on its entransy dissipation. In two-stream heat exchanger networks, only heat exchanges between hot and cold fluids are considered. Thermal resistance analysis indicates that the maximum heat transfer rate between two fluids corresponds to the minimum entransy-dissipation-based thermal resistance; i.e. the minimum thermal resistance principle can be exploited in optimizing heat exchanger networks.
基金supported by the National Natural Science Foundation of China (Grant No 10905093)the Program for New Century Excellent Talents in University of China (Grant No NCET-04-1006)the Foun-dation for the Author of National Excellent Doctoral Dissertation of China (Grant No 200136)
文摘Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mass flow rate of gas and the maximum entransy dissipation rate all depend on the dimensionless diameter of one tube,the dimensionless pressure difference number and the dimensionless length of flow channel of gas.Besides the three dimensionless groups,the optimal numbers of riser tubes and downcomer tubes and their summation all depend on the dimensionless height of one tube.The maximum entransy dissipation rate increases as the pressure difference that drives the gas flowing increases,and as the diameter of one tube and the length of flow channel both decrease.The mean heat flux in the heat transfer process of hot gas grows greatly,and the performance of the system is improved.Compared with the optimal construct with heat transfer rate maximization,the optimal construct with entransy dissipation rate maximization can improved the heat transfer effect of the steam generator more.
基金supported by the National Key Basic Research and Development Program of China (‘973’ Program) (Grant No. 2012CB720405)the National Natural Science Foundation of China (Grant No. 51176203)the Natural Science Foundation for Youngsters of Naval University of Engineering (Grant No. HGDQNJJ11008)
文摘Analogizing with the heat conduction process, the entransy dissipation extremum principle for thermal insulation process can be described as: for a fixed boundary heat flux (heat loss) with certain constraints, the thermal insulation process is optimized when the entransy dissipation is maximized (maximum average temperature difference), while for a fixed boundary temperature, the thermal insulation process is optimized when the entransy dissipation is minimized (minimum average heat loss rate). Based on the constructal theory, the constructal optimizations of a single plane and cylindrical insulation layers as well as multi-layer insulation layers of the steel rolling reheating furnace walls are carried out for the fixed boundary temperatures and by taking the minimization of entransy dissipation rate as optimization objective. The optimal constructs of these three kinds of insulation structures with distributed thicknesses are obtained. The results show that compared with the insulation layers with uniform thicknesses and the optimal constructs of the insulation layers obtained by minimum heat loss rate, the optimal constructs of the insulation layers obtained by minimum entransy dissipation rate are obviously different from those of the former two insulation layers; the optimal constructs of the insulation layers obtained by minimum entransy dissipation rate can effectively reduce the average heat loss rates of the insulation layers, and can help to improve their global thermal insulation performances. The entransy dissipation extremum principle is applied to the constructal optimizations of insulation systems, which will help to extend the application range of the entransy dissipation extremum principle.
基金supported by Tsinghua University Initiative Scientific Research Program
文摘For distribution optimization of the flow rate of cold fluid and heat transfer area in the parallel thermal network of the thermal control system in spacecraft,a physical and mathematical model is set up,analyzed and discussed with the entransy theory.It is found that the optimization objective of this problem and the optimization direction of the extremum entransy dissipation principle are consistent in theory.For a two-branch thermal network system,the distributions of the flow rate of the cold fluid and the heat transfer area are optimized by calculating the extremum entransy dissipation with the Newton method.The influential factors of the optimized distributions are also analyzed and discussed.The results show that the main influence factors are the heat transfer rate of the branches and the total heat transfer area.The total flow rate of the cold fluid has a threshold,beyond which further increasing its value brings very little influence on the optimization results.Moreover,the difference between the extremum entransy dissipation principle and the minimum entropy generation principle is also discussed when they are used to analyze the problem in this paper,and the extremum entransy dissipation principle is found to be more suitable.In addition,the Newton method is mathematically efficient to solve the problem,which could accomplish the optimized distribution in a very short time for a ten-branch thermal network system.
文摘The uniformity principle of temperature difference field is a phenomenological principle,which has not been theoretically proved.For one-dimensional two-and three-stream heat exchangers,the extremum principle of entransy dissipation was used to optimize the heat transfer process by variational calculus.It was indicated that the temperature difference field between the hot and cold fluids should be completely uniform if the entransy dissipation reached a minimum for a given heat duty,or if the heat duty reached a maximum for a given entransy dissipation.So,the uniformity principle of temperature difference field of heat exchangers was primarily proved.
基金The National Natural Science Foundation of China(No.51376110,51541604)the Major International(Regional) Joint Research Project of the National Natural Science Foundation of China(No.61320106011)
文摘The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar collectors with different length and diameter tubes, different coating materials, and with / without guide plates, respectively. Threedimensional mathematical models on natural and forced convections in the solar collectors are established and the experimental data is validated by field synergy and entransy principles. The results of natural convection show that the water temperature increases and thermal efficiency decreases gradually with the evacuated tube length. The thermal efficiency increases when absorption rates increase from 0. 95 to 1. 0 and emission rates decrease from 0. 16 to 0. 06. The thermal efficiency of solar collectors is increased after being equipped with the guide plate, which is attributed to the disappearance of the mixed flowand the enhancement of the heat transfer at the bottom of the evacuated tube. The results of forced convertion indicate that the Reynolds, Nusselt and entransy increments of the horizontal double collectors are higher than those of the vertical single collector while the entransy dissipation is lower than that of the vertical single collector. It is concluded that the solar collectors with guide plates are suitable for natural convection while the double horizontal collectors are suitable for forced convection in the thermal field of solar-assisted fuel cell systems with lowand medium temperatures.
基金supported by the National Natural Science Foundation of China(Grant Nos.51779262,51506220 and 51579244)。
文摘This review paper summarizes constructal design progress performed by the authors for eight types of heat sinks with ten performance indexes being taken as the optimization objectives,respectively,by combining the methods of theoretical analysis and numerical calculation.The eight types of heat sinks are uniform height rectangular fin heat sink,non-uniform height rectangular fin heat sink,inline cylindrical pin-fin heat sink(ICPHS),plate single-row pin fin heat sink(PSRPHS),plate inline pin fin heat sink(PIPHS),plate staggered pin fin heat sink(PSPHS),single-layered microchannel heat sink(SLMCHS)with rectangular cross sections and double-layered microchannel heat sink(DLMCHS)with rectangular cross sections,respectively.And the ten performance indexes are heat transfer rate maximization,maximum thermal resistance minimization,minimization of equivalent thermal resistance which is defined based on the entransy dissipation rate(equivalent thermal resistance for short),field synergy number maximization,entropy generation rate minimization,operation cost minimization,thermo-economic function value minimization,pressure drop minimization,enhanced heat transfer factor maximization and efficiency evaluation criterion number maximization,respectively.The optimal constructs of the eight types of heat sinks with different constraints and based on the different optimization objectives are compared with each other.The results indicated that the optimal constructs mostly are different based on different optimization objectives under the same boundary condition.The optimization objective should be suitable chosen based on the focus when the constructal design for one heat sink is performed.The results obtained herein have some important theoretical significances and application values,and can provide scientific bases and theoretical guidelines for the thermal design of real heat sinks and their applications.