The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process...The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,展开更多
Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ...Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ordinary solution techniques lead to instability near the limit points and also have problems in case of snap-through and snap-back. Thus they fail to predict the complete load-displacement response. The arc-length method serves the purpose well in principle, received wide acceptance in finite element analysis, and has been used extensively. However modifications to the basic idea are vital to meet the particular needs of the analysis. This paper reviews some of the recent developments of the method in the last two decades, with particular emphasis on nonlinear finite element analysis of reinforced concrete structures.展开更多
文摘The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,
文摘Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ordinary solution techniques lead to instability near the limit points and also have problems in case of snap-through and snap-back. Thus they fail to predict the complete load-displacement response. The arc-length method serves the purpose well in principle, received wide acceptance in finite element analysis, and has been used extensively. However modifications to the basic idea are vital to meet the particular needs of the analysis. This paper reviews some of the recent developments of the method in the last two decades, with particular emphasis on nonlinear finite element analysis of reinforced concrete structures.