Magnetic drive pump has gotten great achievement and has been widely used in some special fields. Currently, the researches on magnetic drive pump have focused on hydraulic design, bearing, axial force in China, and a...Magnetic drive pump has gotten great achievement and has been widely used in some special fields. Currently, the researches on magnetic drive pump have focused on hydraulic design, bearing, axial force in China, and a new magnetic drive pump with low flow and high head have been developed overseas. However, low efficiency and large size are the common disadvantages for the magnetic drive pump. In order to study the performance of high-speed magnetic drive pump, FLUENT was used to simulate the inner flow field of magnetic drive pumps with different rotate speeds, and get velocity and pressure distributions of inner flow field. According to analysis the changes of velocity and pressure to ensure the stable operation of pump and avoid cavitation. Based on the analysis of velocity and pressure, this paper presents the pump efficiency of magnetic drive pumps with different rotated speeds by calculating the power loss in impeller and volute, hydraulic loss, volumetric loss, mechanical loss and discussing the different reasons of power loss between the magnetic drive pumps with different rotated speeds. In addition, the magnetic drive pumps were tested in a closed testing system. Pressure sensors were set in inlet and outlet of magnetic drive pumps to get the pressure and the head, while the pump efficiency could be got by calculating the power loss between the input power and the outlet power. The results of simulation and test were similar, which shows that the method of simulation is feasible. The proposed research provides the instruction to design high-speed magnetic drive pump.展开更多
Wave-driven circulation in a reef-lagoon-channel system has significant ecological,geomorphological,and environmental implications.However,there is still research gap in fully understanding the responses of wave-drive...Wave-driven circulation in a reef-lagoon-channel system has significant ecological,geomorphological,and environmental implications.However,there is still research gap in fully understanding the responses of wave-driven circulation in the system to varying incident wave forcing and reef morphology.To better interpret the wave-current process inside an idealized reef-lagoon-channel configuration,a numerical model based on the horizontally two-dimensional(2DH)fully nonlinear Boussinesq equations is presented in this study.The adopted model is firstly validated by a published laboratory dataset for wave height,wave setup and mean current in the system.Subsequently,the impacts of wave forcing(incident wave height,incident wave period,reef-flat wave level)and reef morphological(fore-reef slope,cross-shore reef-flat width,channel width,reef roughness)factors that are not fully considered in the previous laboratory studies are reported through the numerical simulations in this study.Finally,the model is applied to analyze the wave pump efficiency parameter in the system,and an empirical equation to predict this parameter is also proposed.展开更多
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des...In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.展开更多
Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly ...Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.展开更多
Diyarbaklr basalt aquifer is volcanic-rock aquifers which contain high quality water. It was main resources for Diyarbaklr city center drinking supply up to 2005. Somewhere, basalt aquifer groundwater is still used fo...Diyarbaklr basalt aquifer is volcanic-rock aquifers which contain high quality water. It was main resources for Diyarbaklr city center drinking supply up to 2005. Somewhere, basalt aquifer groundwater is still used for irrigation in rural areas of Diyarbaklr city. In the study, Diyarbaklr city center's (which is located on the Tigris river basin) basalt aquifer groundwater potentials and hydrogeological features are examined and modeled by using GIS programmer. Firstly, general geological data, meteorological data and general information about natural water sources are collected together, afterwards, logs of well drilled by public institutions and private individuals within the Diyarbaklr city center are analyzed. Static water level, dynamic water level and well pumps yields are classified in these logs. Then, thematic maps produced with the help of Arc Info Professional GIS programmer with geostatistical analyst tool. Groundwater source potential of Diyarbaktr is examined by means of these thematic maps. In hydrogeological research, productivity by aquifer features, water retention capacity and groundwater level data evaluated with geological structure of area are taken into consideration.展开更多
This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory(EEPROM).The low power is minimized by a capacitance divider circuit ...This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory(EEPROM).The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique.The high efficiency is dependent on the zero threshold voltage(V_(th)) MOSFET and the charge transfer switch(CTS) charge pump.The proposed high voltage generator circuit has been implemented in a 0.35μm EEPROM CMOS process.Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48μW and a higher pumping efficiency(83.3%) than previously reported circuits.This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation.展开更多
基金supported by National Science and Technology Support Scheme of China (Grant No. 2008BAF34B10)
文摘Magnetic drive pump has gotten great achievement and has been widely used in some special fields. Currently, the researches on magnetic drive pump have focused on hydraulic design, bearing, axial force in China, and a new magnetic drive pump with low flow and high head have been developed overseas. However, low efficiency and large size are the common disadvantages for the magnetic drive pump. In order to study the performance of high-speed magnetic drive pump, FLUENT was used to simulate the inner flow field of magnetic drive pumps with different rotate speeds, and get velocity and pressure distributions of inner flow field. According to analysis the changes of velocity and pressure to ensure the stable operation of pump and avoid cavitation. Based on the analysis of velocity and pressure, this paper presents the pump efficiency of magnetic drive pumps with different rotated speeds by calculating the power loss in impeller and volute, hydraulic loss, volumetric loss, mechanical loss and discussing the different reasons of power loss between the magnetic drive pumps with different rotated speeds. In addition, the magnetic drive pumps were tested in a closed testing system. Pressure sensors were set in inlet and outlet of magnetic drive pumps to get the pressure and the head, while the pump efficiency could be got by calculating the power loss between the input power and the outlet power. The results of simulation and test were similar, which shows that the method of simulation is feasible. The proposed research provides the instruction to design high-speed magnetic drive pump.
基金supported by the National Natural Science Foundation of China(Grant Nos.51979013 and 51909013)the National Key Research and Development Program of China(Grant Nos.2021YFC3100502 and 2021YFB2601104).
文摘Wave-driven circulation in a reef-lagoon-channel system has significant ecological,geomorphological,and environmental implications.However,there is still research gap in fully understanding the responses of wave-driven circulation in the system to varying incident wave forcing and reef morphology.To better interpret the wave-current process inside an idealized reef-lagoon-channel configuration,a numerical model based on the horizontally two-dimensional(2DH)fully nonlinear Boussinesq equations is presented in this study.The adopted model is firstly validated by a published laboratory dataset for wave height,wave setup and mean current in the system.Subsequently,the impacts of wave forcing(incident wave height,incident wave period,reef-flat wave level)and reef morphological(fore-reef slope,cross-shore reef-flat width,channel width,reef roughness)factors that are not fully considered in the previous laboratory studies are reported through the numerical simulations in this study.Finally,the model is applied to analyze the wave pump efficiency parameter in the system,and an empirical equation to predict this parameter is also proposed.
文摘In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.
文摘Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.
文摘Diyarbaklr basalt aquifer is volcanic-rock aquifers which contain high quality water. It was main resources for Diyarbaklr city center drinking supply up to 2005. Somewhere, basalt aquifer groundwater is still used for irrigation in rural areas of Diyarbaklr city. In the study, Diyarbaklr city center's (which is located on the Tigris river basin) basalt aquifer groundwater potentials and hydrogeological features are examined and modeled by using GIS programmer. Firstly, general geological data, meteorological data and general information about natural water sources are collected together, afterwards, logs of well drilled by public institutions and private individuals within the Diyarbaklr city center are analyzed. Static water level, dynamic water level and well pumps yields are classified in these logs. Then, thematic maps produced with the help of Arc Info Professional GIS programmer with geostatistical analyst tool. Groundwater source potential of Diyarbaktr is examined by means of these thematic maps. In hydrogeological research, productivity by aquifer features, water retention capacity and groundwater level data evaluated with geological structure of area are taken into consideration.
基金supported by the National Natural Science Foundation of China(No.61072010)
文摘This paper presents a low power and high efficiency high voltage generator circuit embedded in electrically erasable programmable read-only memory(EEPROM).The low power is minimized by a capacitance divider circuit and a regulator circuit using the controlling clock switch technique.The high efficiency is dependent on the zero threshold voltage(V_(th)) MOSFET and the charge transfer switch(CTS) charge pump.The proposed high voltage generator circuit has been implemented in a 0.35μm EEPROM CMOS process.Measured results show that the proposed high voltage generator circuit has a low power consumption of about 150.48μW and a higher pumping efficiency(83.3%) than previously reported circuits.This high voltage generator circuit can also be widely used in low-power flash devices due to its high efficiency and low power dissipation.