According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification in...According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.展开更多
Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To ...Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values.展开更多
Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and med...Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and mediumrise reinforced concrete(RC)frame structures with 4 and 8 stories,respectively.The sensitivity of the aleatory randomness estimated in fragility curves to various S_(a)(T_(1))-based IMs is analyzed at three damage limit states,i.e.,immediate occupancy,life safety,and collapse prevention.In addition,the effect of characterization methods of bidirectional ground motion intensity on the record-to-record variability is investigated.It is found that the damage limit state of the structure has an important influence on the applicability of the ground motion IM.The S_(a)(T_(1))-based IMs,considering the effect of softened period,can maintain lower record-to-record variability in the three limit states,and the S_(a)(T_(1))-based IMs,considering the effect of higher modes,do not show their advantage over S_(a)(T_(1)).Furthermore,the optimal multiplier C and exponentαin the dual-parameter ground motion IM are proposed to obtain a lower record-to-record variability in the fragility analysis of different damage limit state.Finally,the improved dual-parameter ground motion IM is applied in the risk assessment of the 8-story frame structure.展开更多
Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Inf...Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenehuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.展开更多
On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major fai...On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major failure occurr<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ing</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> on the connection between the RC column top and steel roof as well as the cracks in the RC column base w</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> observed during the emergent inspection. According to the earlier studies, it was implied that the presence of the slotted hole possibly deteriorates the seismic capacity;however, the length of slotted hole was fixed at a certain value. Facing this concern, this research attempts to clarify the influence of the slotted hole length through a comprehensive parametric study by pushover and seismic response analyses. In conclusion, it has been discovered that the slotted hole deteriorates the seismic capacity for the connection failure up to almost 50% of that without slotted hole. Moreover, the discrepancy of characteristics obtained by the static and dynamic analyses is originated by means of the presence of slotted hole. This slotted hole effect should be noted by structural engineers and researchers to provide the adequate seismic diagnosis and strengthening.</span></span></span>展开更多
The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving ...The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving seismic design to mitigate earthquake-induced damages and enhance structural performance. In this study, a specific reinforced concrete (RC) frame structure at Kyungpook National University, designed for educational purposes, is analyzed as a representative case. Utilizing SAP 2000, the research conducts a nonlinear time history analysis to assess the structural performance under seismic conditions. The primary objective is to evaluate the influence of different column section designs, while maintaining identical column section areas, on structural behavior. The study employs two distinct seismic waves from Abeno (ABN) and Takatori (TKT) for the analysis, comparing the structural performance under varying seismic conditions. Key aspects examined include displacement, base shear force, base moment, joint radians, and layer displacement angle. This research is anticipated to serve as a valuable reference for seismic restraint reinforcement work on RC buildings, enriching the methods used for evaluating structures through nonlinear time history analysis based on the synthetic seismic wave approach.展开更多
In order to analyze and simulate the impact collapse or seismic response of the reinforced concrete(RC)structures,a combined fiber beam model is proposed by dividing the cross section of RC beam into concrete fiber an...In order to analyze and simulate the impact collapse or seismic response of the reinforced concrete(RC)structures,a combined fiber beam model is proposed by dividing the cross section of RC beam into concrete fiber and steel fiber.The stress-strain relationship of concrete fiber is based on a model proposed by concrete codes for concrete structures.The stress-strain behavior of steel fiber is based on a model suggested by others.These constitutive models are implemented into a general finite element program ABAQUS through the user defined subroutines to provide effective computational tools for the inelastic analysis of RC frame structures.The fiber model proposed in this paper is validated by comparing with experiment data of the RC column under cyclical lateral loading.The damage evolution of a three-dimension frame subjected to impact loading is also investigated.展开更多
In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground...In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground motion records from the main shock were obtained from three nearby stations. The acceleration records were analyzed in terms of instantaneous tangential acceleration αv normal acceleration αN, Euclidean norm of acceleration vector lal, velocity vector |v|, displacement vector |d|, temporal curvature κ,κt, and temporal torsion γ and γt.Results of the kinematic relationship between the above factors and some additional in depth information obtained from extensive analyses are provided and discussed.展开更多
基金National Science Foundation of China Under Grant No.90815025&51178249the National Key Technologies R&D Program Under Grant No.2009BAJ28B01&2006BAJ03A02-01+1 种基金Tsinghua University Research Funds No.2010THZ02-1the Program for New Century Excellent Talents in University
文摘According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.
基金Supported by the National Natural Science Foundation of China(No.51525803)the Scientific and Technological Development Plans of Tianjin Construction System(No.2013-35)+1 种基金International Science&Technology Cooperation Program of China(No.2012DFA70810)the Basic Science Research Foundation of IEM,CEA(No.2013B07)
文摘Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values.
基金the Jiangsu Youth Fund Projects(SBK2021044269)the National Natural Science Foundation of China Youth Fund(52108457,52108133)+4 种基金the Natural Science Foundation of the Jiangsu Higher Education Institutions of China(20KJB560014)Fundamental Research Funds for the Central Universities(B210201019)High-level Talent Research Fund of Nanjing Forestry University(163050115)Nanjing Forestry University Undergraduate Innovation Training Program(2021NFUSPITP0221,2020NFUSPITP0352 and 2020NFUSPITP0373)Jiangsu Undergraduate Innovation Training Program(202110298079Y).
文摘Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and mediumrise reinforced concrete(RC)frame structures with 4 and 8 stories,respectively.The sensitivity of the aleatory randomness estimated in fragility curves to various S_(a)(T_(1))-based IMs is analyzed at three damage limit states,i.e.,immediate occupancy,life safety,and collapse prevention.In addition,the effect of characterization methods of bidirectional ground motion intensity on the record-to-record variability is investigated.It is found that the damage limit state of the structure has an important influence on the applicability of the ground motion IM.The S_(a)(T_(1))-based IMs,considering the effect of softened period,can maintain lower record-to-record variability in the three limit states,and the S_(a)(T_(1))-based IMs,considering the effect of higher modes,do not show their advantage over S_(a)(T_(1)).Furthermore,the optimal multiplier C and exponentαin the dual-parameter ground motion IM are proposed to obtain a lower record-to-record variability in the fragility analysis of different damage limit state.Finally,the improved dual-parameter ground motion IM is applied in the risk assessment of the 8-story frame structure.
基金the partial financial support from Kwang-Hua Fund for College of Civil Engineering,Tongji Universitythe National Natural Science Foundation of China(Grant No.51078274,51021140006)
文摘Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenehuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.
文摘On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major failure occurr<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ing</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> on the connection between the RC column top and steel roof as well as the cracks in the RC column base w</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> observed during the emergent inspection. According to the earlier studies, it was implied that the presence of the slotted hole possibly deteriorates the seismic capacity;however, the length of slotted hole was fixed at a certain value. Facing this concern, this research attempts to clarify the influence of the slotted hole length through a comprehensive parametric study by pushover and seismic response analyses. In conclusion, it has been discovered that the slotted hole deteriorates the seismic capacity for the connection failure up to almost 50% of that without slotted hole. Moreover, the discrepancy of characteristics obtained by the static and dynamic analyses is originated by means of the presence of slotted hole. This slotted hole effect should be noted by structural engineers and researchers to provide the adequate seismic diagnosis and strengthening.</span></span></span>
文摘The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving seismic design to mitigate earthquake-induced damages and enhance structural performance. In this study, a specific reinforced concrete (RC) frame structure at Kyungpook National University, designed for educational purposes, is analyzed as a representative case. Utilizing SAP 2000, the research conducts a nonlinear time history analysis to assess the structural performance under seismic conditions. The primary objective is to evaluate the influence of different column section designs, while maintaining identical column section areas, on structural behavior. The study employs two distinct seismic waves from Abeno (ABN) and Takatori (TKT) for the analysis, comparing the structural performance under varying seismic conditions. Key aspects examined include displacement, base shear force, base moment, joint radians, and layer displacement angle. This research is anticipated to serve as a valuable reference for seismic restraint reinforcement work on RC buildings, enriching the methods used for evaluating structures through nonlinear time history analysis based on the synthetic seismic wave approach.
基金supported by the National Natural Science Foundation of China(Grant No.90815026)
文摘In order to analyze and simulate the impact collapse or seismic response of the reinforced concrete(RC)structures,a combined fiber beam model is proposed by dividing the cross section of RC beam into concrete fiber and steel fiber.The stress-strain relationship of concrete fiber is based on a model proposed by concrete codes for concrete structures.The stress-strain behavior of steel fiber is based on a model suggested by others.These constitutive models are implemented into a general finite element program ABAQUS through the user defined subroutines to provide effective computational tools for the inelastic analysis of RC frame structures.The fiber model proposed in this paper is validated by comparing with experiment data of the RC column under cyclical lateral loading.The damage evolution of a three-dimension frame subjected to impact loading is also investigated.
基金NSFC program (No. 50678161)the National Major Basic Research 973 Program Under Grant No. 2007CB714205+1 种基金the Science and Technology Support Program Under Grant No. 2006BAC13B02-0301 of the Ministry of Science and Technology of Chinathe Basic Science Research Foundation Program through Institute of Engineering Mechanics, CEA
文摘In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground motion records from the main shock were obtained from three nearby stations. The acceleration records were analyzed in terms of instantaneous tangential acceleration αv normal acceleration αN, Euclidean norm of acceleration vector lal, velocity vector |v|, displacement vector |d|, temporal curvature κ,κt, and temporal torsion γ and γt.Results of the kinematic relationship between the above factors and some additional in depth information obtained from extensive analyses are provided and discussed.