Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the p...Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner.展开更多
This study investigates the efficiency of two types of rehabilitation methods based on economic justification that can lead to logical decision making between the retrofitting schemes. Among various rehabilitation met...This study investigates the efficiency of two types of rehabilitation methods based on economic justification that can lead to logical decision making between the retrofitting schemes. Among various rehabilitation methods, concentric chevron bracing(CCB) and cylindrical friction damper(CFD) were selected. The performance assessment procedure of the frames is divided into two distinct phases. First, the limit state probabilities of the structures before and after rehabilitation are investigated. In the second phase, the seismic risk of structures in terms of life safety and financial losses(decision variables) using the recently published FEMA P58 methodology is evaluated. The results show that the proposed retrofitting methods improve the serviceability and life safety performance levels of steel and RC structures at different rates when subjected to earthquake loads. Moreover, these procedures reveal that financial losses are greatly decreased, and were more tangible by the application of CFD rather than using CCB. Although using both retrofitting methods reduced damage state probabilities, incorporation of a site-specific seismic hazard curve to evaluate mean annual occurrence frequency at the collapse prevention limit state caused unexpected results to be obtained. Contrary to CFD, the collapse probability of the structures retrofitted with CCB increased when compared with the primary structures.展开更多
This paper presents an investigation of the seismic behavior of reinforced concrete(RC)structures in which shear walls are the main lateral load-resisting elements and the participation of flat slab floor systems is n...This paper presents an investigation of the seismic behavior of reinforced concrete(RC)structures in which shear walls are the main lateral load-resisting elements and the participation of flat slab floor systems is not considered in the seismic design procedure.In this regard,the behavior of six prototype structures(with different heights and plan layouts)is investigated through nonlinear static and time history analyses,implemented in the OpenSees platform.The results of the analyses are presented in terms of the behavior of the slab-column connections and their mode of failure at different loading stages.Moreover,the global response of the buildings is discussed in terms of some parameters,such as lateral overstrength due to the gravity flat slab-column frames.According to the nonlinear static analyses,in structures in which the slab-column connections were designed only for gravity loads,the slab-column connections exhibited a punching mode of failure even in the early stages of loading.However,the punching failure was eliminated in structures in which a minimum transverse reinforcement recommended in ACI 318(2019)was provided in the slabs at joint regions.Furthermore,despite neglecting the contribution of gravity flat slab-column frames in the lateral load resistance of the structures,a relatively significant overstrength was imposed on the structures by the gravity frames.展开更多
The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving ...The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving seismic design to mitigate earthquake-induced damages and enhance structural performance. In this study, a specific reinforced concrete (RC) frame structure at Kyungpook National University, designed for educational purposes, is analyzed as a representative case. Utilizing SAP 2000, the research conducts a nonlinear time history analysis to assess the structural performance under seismic conditions. The primary objective is to evaluate the influence of different column section designs, while maintaining identical column section areas, on structural behavior. The study employs two distinct seismic waves from Abeno (ABN) and Takatori (TKT) for the analysis, comparing the structural performance under varying seismic conditions. Key aspects examined include displacement, base shear force, base moment, joint radians, and layer displacement angle. This research is anticipated to serve as a valuable reference for seismic restraint reinforcement work on RC buildings, enriching the methods used for evaluating structures through nonlinear time history analysis based on the synthetic seismic wave approach.展开更多
According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification in...According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.展开更多
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ...The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.展开更多
The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an eff...The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters(EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes(i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities.展开更多
A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given...A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given structure is to "preserve living spaces for people in the buildings." In this paper,factors that may influence the collapse resistance of RC frames in a mega-earthquake are analyzed based on seismic damage observed in the 2008 Wenchuan earthquake. Methodologies to improve structural collapse resistance focus on three aspects:global strength margin,global redundancy and global integration of the structural system. Fundamental principles and design concepts for collapse prevention under a mega-earthquake are proposed,and issues that need further research are identified.展开更多
The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analyt...The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analytical model of the overall structure was developed in OpenSees.The multi-spring contact element was adopted to simulate gap open-close behavior at connection interfaces.The limit states of external mild steel dampers and unbonded post-tensioning strands were considered.Static pushover analyses were performed up to the roof drift of 10%.The nonlinear dynamic responses under four groups of ground motions(with different fault distances and site conditions)at six hazard levels(from the service to the very rare earthquake(VRE))were compared.Incremental dynamic analyses were implemented to quantify the structural collapse risk.The results showed that the structural responses of SC-RCF were satisfactory under all levels of earthquakes.The collapse safety of the structure under earthquakes up to VRE1 was adequate,while the structure would collapse to a large extent under VRE2 and VRE3.展开更多
On 3 August 2014, the Ludian earthquake struck northwest Yunnan Province with a surface wave magnitude of 6.5. This moderate earthquake unexpectedly caused high fatalities and great economic loss. Four strong motion s...On 3 August 2014, the Ludian earthquake struck northwest Yunnan Province with a surface wave magnitude of 6.5. This moderate earthquake unexpectedly caused high fatalities and great economic loss. Four strong motion stations were located in the areas with intensity V, VI, VII and IX, near the epicentre. The characteristics of the ground motion are discussed herein, including 1) ground motion was strong at a period of less than 1.4 s, which covered the natural vibration period of a large number of structures; and 2) the release energy was concentrated geographically. Based on materials collected during emergency building inspections, the damage patterns of adobe, masonry, timber frame and reinforced concrete (RC) frame structures in areas with different intensities are summarised. Earthquake damage matrices of local buildings are also given for fragility evaluation and earthquake damage prediction. It is found that the collapse ratios of RC frame and confined masonry structures based on the new design code are significantly lower than non-seismic buildings. However, the RC frame structures still failed to achieve the 'strong column, weak beam' design target. Traditional timber frame structures with a light infill wall showed good aseismic performance.展开更多
The natural landscape in China exposes many existing RC buildings to aggressive environments.Such exposure can lead to deterioration in structural performance with regard to resisting events such as earthquakes.Corros...The natural landscape in China exposes many existing RC buildings to aggressive environments.Such exposure can lead to deterioration in structural performance with regard to resisting events such as earthquakes.Corrosion of embedded reinforcement is one of the most common mechanisms by which such structural degradation occurs.There has been increasing attention in recent years toward seismic resilience in communities and their constituent construction;however,to date,studies have neglected the effect of natural aging.This study aims to examine the effect of reinforcement corrosion on the seismic resilience of RC frames that are designed according to Chinese seismic design codes.A total of twenty RC frames are used to represent design and construction that is typical of coastal China,with consideration given to various seismic fortification levels and elevation arrangements.Seismic fragility relationships are developed for case frames under varying levels of reinforcement corrosion,i.e.,corrosion rates are increased from 5%to 15%.Subsequently,the seismic resilience levels of uncorroded and corroded RC frames are compared using a normalized loss factor.It was found that the loss of resilience of the corroded frames is greater than that of their uncorroded counterparts.At the Rare Earthquake hazard level,the corrosioninduced increase in loss of resilience can be more than 200%,showing the significant effect of reinforcement corrosion on structural resilience under the influence of earthquakes.展开更多
The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 eart...The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.展开更多
Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To ...Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values.展开更多
Structural health monitoring of RC structures under seismic loads has recently attracted much attention in the earthquake engineering research community. In this study, a piezoceramic-based device called "smart aggre...Structural health monitoring of RC structures under seismic loads has recently attracted much attention in the earthquake engineering research community. In this study, a piezoceramic-based device called "smart aggregate" was used for the health monitoring of RC frame structures under earthquake excitations. Three RC moment frames instrumented with smart aggregates were tested using a shaketable with different ground excitation intensities. Distributed piezoceramic- based smart aggregates were embedded in the RC structures and used to monitor their health condition during the tests. The sensitivity and effectiveness of the proposed piezoceramic-based approach were investigated and evaluated by analyzing the measured responses. The displacement ductility demand of the structural members was calculated and compared with the damage index determined from the health monitoring system. The comparison shows that the damage index is compatible with the calculated ductility demand.展开更多
Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the ...Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction, the general design practice is to treat infills as nonstructural elements and their stiffness, strength and interaction with the frame is often ignored, primarily because of difficulties in simulation and lack of modeling guidelines in design codes. The Indian Standard, like many other national codes, does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames. This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills. Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered. HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames. The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.展开更多
Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and med...Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and mediumrise reinforced concrete(RC)frame structures with 4 and 8 stories,respectively.The sensitivity of the aleatory randomness estimated in fragility curves to various S_(a)(T_(1))-based IMs is analyzed at three damage limit states,i.e.,immediate occupancy,life safety,and collapse prevention.In addition,the effect of characterization methods of bidirectional ground motion intensity on the record-to-record variability is investigated.It is found that the damage limit state of the structure has an important influence on the applicability of the ground motion IM.The S_(a)(T_(1))-based IMs,considering the effect of softened period,can maintain lower record-to-record variability in the three limit states,and the S_(a)(T_(1))-based IMs,considering the effect of higher modes,do not show their advantage over S_(a)(T_(1)).Furthermore,the optimal multiplier C and exponentαin the dual-parameter ground motion IM are proposed to obtain a lower record-to-record variability in the fragility analysis of different damage limit state.Finally,the improved dual-parameter ground motion IM is applied in the risk assessment of the 8-story frame structure.展开更多
Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Inf...Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenehuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.展开更多
In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground...In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground motion records from the main shock were obtained from three nearby stations. The acceleration records were analyzed in terms of instantaneous tangential acceleration αv normal acceleration αN, Euclidean norm of acceleration vector lal, velocity vector |v|, displacement vector |d|, temporal curvature κ,κt, and temporal torsion γ and γt.Results of the kinematic relationship between the above factors and some additional in depth information obtained from extensive analyses are provided and discussed.展开更多
Frequent aftershocks often follow a strong mainshock.They can significantly increase cumulative damage to a structure.A model of a five-story reinforced concrete frame structure was designed and a nonlinear mathematic...Frequent aftershocks often follow a strong mainshock.They can significantly increase cumulative damage to a structure.A model of a five-story reinforced concrete frame structure was designed and a nonlinear mathematical model of the structure was developed to investigate the damage states resulting from different mainshock-aftershock sequences.Mainshock-aftershock sequences consisting of one of three recorded mainshocks combined with one of five recorded aftershocks were created for input to the mathematical model.Inelastic energy dissipation and the Park-Ang damage index were used as measures of cumulative damage to the structure.The results demonstrate that consideration of only the single mainshock ground motion in seismic building design can result in the design and construction of unsafe buildings.Total cumulative damage to a structure is caused by the combination of damage states resulting from the mainshock and the aftershock(s).展开更多
On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major fai...On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major failure occurr<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ing</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> on the connection between the RC column top and steel roof as well as the cracks in the RC column base w</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> observed during the emergent inspection. According to the earlier studies, it was implied that the presence of the slotted hole possibly deteriorates the seismic capacity;however, the length of slotted hole was fixed at a certain value. Facing this concern, this research attempts to clarify the influence of the slotted hole length through a comprehensive parametric study by pushover and seismic response analyses. In conclusion, it has been discovered that the slotted hole deteriorates the seismic capacity for the connection failure up to almost 50% of that without slotted hole. Moreover, the discrepancy of characteristics obtained by the static and dynamic analyses is originated by means of the presence of slotted hole. This slotted hole effect should be noted by structural engineers and researchers to provide the adequate seismic diagnosis and strengthening.</span></span></span>展开更多
文摘Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner.
文摘This study investigates the efficiency of two types of rehabilitation methods based on economic justification that can lead to logical decision making between the retrofitting schemes. Among various rehabilitation methods, concentric chevron bracing(CCB) and cylindrical friction damper(CFD) were selected. The performance assessment procedure of the frames is divided into two distinct phases. First, the limit state probabilities of the structures before and after rehabilitation are investigated. In the second phase, the seismic risk of structures in terms of life safety and financial losses(decision variables) using the recently published FEMA P58 methodology is evaluated. The results show that the proposed retrofitting methods improve the serviceability and life safety performance levels of steel and RC structures at different rates when subjected to earthquake loads. Moreover, these procedures reveal that financial losses are greatly decreased, and were more tangible by the application of CFD rather than using CCB. Although using both retrofitting methods reduced damage state probabilities, incorporation of a site-specific seismic hazard curve to evaluate mean annual occurrence frequency at the collapse prevention limit state caused unexpected results to be obtained. Contrary to CFD, the collapse probability of the structures retrofitted with CCB increased when compared with the primary structures.
文摘This paper presents an investigation of the seismic behavior of reinforced concrete(RC)structures in which shear walls are the main lateral load-resisting elements and the participation of flat slab floor systems is not considered in the seismic design procedure.In this regard,the behavior of six prototype structures(with different heights and plan layouts)is investigated through nonlinear static and time history analyses,implemented in the OpenSees platform.The results of the analyses are presented in terms of the behavior of the slab-column connections and their mode of failure at different loading stages.Moreover,the global response of the buildings is discussed in terms of some parameters,such as lateral overstrength due to the gravity flat slab-column frames.According to the nonlinear static analyses,in structures in which the slab-column connections were designed only for gravity loads,the slab-column connections exhibited a punching mode of failure even in the early stages of loading.However,the punching failure was eliminated in structures in which a minimum transverse reinforcement recommended in ACI 318(2019)was provided in the slabs at joint regions.Furthermore,despite neglecting the contribution of gravity flat slab-column frames in the lateral load resistance of the structures,a relatively significant overstrength was imposed on the structures by the gravity frames.
文摘The significant impact of earthquakes on human lives and the built environment underscores the extensive human and economic losses caused by structural collapses. Over the years, researchers have focused on improving seismic design to mitigate earthquake-induced damages and enhance structural performance. In this study, a specific reinforced concrete (RC) frame structure at Kyungpook National University, designed for educational purposes, is analyzed as a representative case. Utilizing SAP 2000, the research conducts a nonlinear time history analysis to assess the structural performance under seismic conditions. The primary objective is to evaluate the influence of different column section designs, while maintaining identical column section areas, on structural behavior. The study employs two distinct seismic waves from Abeno (ABN) and Takatori (TKT) for the analysis, comparing the structural performance under varying seismic conditions. Key aspects examined include displacement, base shear force, base moment, joint radians, and layer displacement angle. This research is anticipated to serve as a valuable reference for seismic restraint reinforcement work on RC buildings, enriching the methods used for evaluating structures through nonlinear time history analysis based on the synthetic seismic wave approach.
基金National Science Foundation of China Under Grant No.90815025&51178249the National Key Technologies R&D Program Under Grant No.2009BAJ28B01&2006BAJ03A02-01+1 种基金Tsinghua University Research Funds No.2010THZ02-1the Program for New Century Excellent Talents in University
文摘According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.
基金National Natural Science Foundation of China(NSFC)under Grant Nos.51638012 and 51578401
文摘The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.
基金Beijing Natural Science Foundation under Grant No. 8192008the Scientific Research Foundation of Graduate School of Southeast University under Grant No. YBPY2021+1 种基金the Science and Technology Project of Beijing Municipal Education Commission under Grant No. KM201910016014the Program for Changjiang Scholars and Innovative Research Team in University under Grant No. IRT_17R06。
文摘The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters(EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes(i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities.
基金National Natural Science Foundation of China Under Grant No.90815025 The National Key Technologies R&D Program Under Grant No.2009BAJ28B01,2006BAJ03A02-01 for Changjiang Scholars and Innovative Research Team in Universities
文摘A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given structure is to "preserve living spaces for people in the buildings." In this paper,factors that may influence the collapse resistance of RC frames in a mega-earthquake are analyzed based on seismic damage observed in the 2008 Wenchuan earthquake. Methodologies to improve structural collapse resistance focus on three aspects:global strength margin,global redundancy and global integration of the structural system. Fundamental principles and design concepts for collapse prevention under a mega-earthquake are proposed,and issues that need further research are identified.
基金Key Project of the Key Laboratory of Earthquake Engineering and Engineering Vibration,China Earthquake Administration under Grant No.2019EEEVL0304National Natural Science Foundation of China(NSFC)under Grant No.51678543。
文摘The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analytical model of the overall structure was developed in OpenSees.The multi-spring contact element was adopted to simulate gap open-close behavior at connection interfaces.The limit states of external mild steel dampers and unbonded post-tensioning strands were considered.Static pushover analyses were performed up to the roof drift of 10%.The nonlinear dynamic responses under four groups of ground motions(with different fault distances and site conditions)at six hazard levels(from the service to the very rare earthquake(VRE))were compared.Incremental dynamic analyses were implemented to quantify the structural collapse risk.The results showed that the structural responses of SC-RCF were satisfactory under all levels of earthquakes.The collapse safety of the structure under earthquakes up to VRE1 was adequate,while the structure would collapse to a large extent under VRE2 and VRE3.
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant No.2014B-01China Postdoctoral Science Foundation under Grant No.2013M531083+3 种基金Natural Science Foundation of Hei Longjiang Province of China under Grant No.LC2012C32National Natural Science Foundation of China under Grant Nos.513085115150853551208234
文摘On 3 August 2014, the Ludian earthquake struck northwest Yunnan Province with a surface wave magnitude of 6.5. This moderate earthquake unexpectedly caused high fatalities and great economic loss. Four strong motion stations were located in the areas with intensity V, VI, VII and IX, near the epicentre. The characteristics of the ground motion are discussed herein, including 1) ground motion was strong at a period of less than 1.4 s, which covered the natural vibration period of a large number of structures; and 2) the release energy was concentrated geographically. Based on materials collected during emergency building inspections, the damage patterns of adobe, masonry, timber frame and reinforced concrete (RC) frame structures in areas with different intensities are summarised. Earthquake damage matrices of local buildings are also given for fragility evaluation and earthquake damage prediction. It is found that the collapse ratios of RC frame and confined masonry structures based on the new design code are significantly lower than non-seismic buildings. However, the RC frame structures still failed to achieve the 'strong column, weak beam' design target. Traditional timber frame structures with a light infill wall showed good aseismic performance.
基金National Natural Science Foundation of China under Grant No.51778198the Natural Science Foundation for Excellent Young Scientists of Heilongjiang Province under Grant No.YQ2020E023。
文摘The natural landscape in China exposes many existing RC buildings to aggressive environments.Such exposure can lead to deterioration in structural performance with regard to resisting events such as earthquakes.Corrosion of embedded reinforcement is one of the most common mechanisms by which such structural degradation occurs.There has been increasing attention in recent years toward seismic resilience in communities and their constituent construction;however,to date,studies have neglected the effect of natural aging.This study aims to examine the effect of reinforcement corrosion on the seismic resilience of RC frames that are designed according to Chinese seismic design codes.A total of twenty RC frames are used to represent design and construction that is typical of coastal China,with consideration given to various seismic fortification levels and elevation arrangements.Seismic fragility relationships are developed for case frames under varying levels of reinforcement corrosion,i.e.,corrosion rates are increased from 5%to 15%.Subsequently,the seismic resilience levels of uncorroded and corroded RC frames are compared using a normalized loss factor.It was found that the loss of resilience of the corroded frames is greater than that of their uncorroded counterparts.At the Rare Earthquake hazard level,the corrosioninduced increase in loss of resilience can be more than 200%,showing the significant effect of reinforcement corrosion on structural resilience under the influence of earthquakes.
基金jointly sponsored by the Institute of Engineering Mechanicsthe Natural Science Foundation of China(No.52122811)。
文摘The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.
基金Supported by the National Natural Science Foundation of China(No.51525803)the Scientific and Technological Development Plans of Tianjin Construction System(No.2013-35)+1 种基金International Science&Technology Cooperation Program of China(No.2012DFA70810)the Basic Science Research Foundation of IEM,CEA(No.2013B07)
文摘Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values.
基金NSC under Grant No.98-2221-E-027-057-MY2the Center for Research on Earthquake Engineering(NCREE)
文摘Structural health monitoring of RC structures under seismic loads has recently attracted much attention in the earthquake engineering research community. In this study, a piezoceramic-based device called "smart aggregate" was used for the health monitoring of RC frame structures under earthquake excitations. Three RC moment frames instrumented with smart aggregates were tested using a shaketable with different ground excitation intensities. Distributed piezoceramic- based smart aggregates were embedded in the RC structures and used to monitor their health condition during the tests. The sensitivity and effectiveness of the proposed piezoceramic-based approach were investigated and evaluated by analyzing the measured responses. The displacement ductility demand of the structural members was calculated and compared with the damage index determined from the health monitoring system. The comparison shows that the damage index is compatible with the calculated ductility demand.
文摘Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction, the general design practice is to treat infills as nonstructural elements and their stiffness, strength and interaction with the frame is often ignored, primarily because of difficulties in simulation and lack of modeling guidelines in design codes. The Indian Standard, like many other national codes, does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames. This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills. Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered. HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames. The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.
基金the Jiangsu Youth Fund Projects(SBK2021044269)the National Natural Science Foundation of China Youth Fund(52108457,52108133)+4 种基金the Natural Science Foundation of the Jiangsu Higher Education Institutions of China(20KJB560014)Fundamental Research Funds for the Central Universities(B210201019)High-level Talent Research Fund of Nanjing Forestry University(163050115)Nanjing Forestry University Undergraduate Innovation Training Program(2021NFUSPITP0221,2020NFUSPITP0352 and 2020NFUSPITP0373)Jiangsu Undergraduate Innovation Training Program(202110298079Y).
文摘Based on the multiple stripes analysis method,an investigation of the estimation of aleatory randomness by S_(a)(T_(1))-based intensity measures(IMs)in the fragility analysis is carried out for two typical low-and mediumrise reinforced concrete(RC)frame structures with 4 and 8 stories,respectively.The sensitivity of the aleatory randomness estimated in fragility curves to various S_(a)(T_(1))-based IMs is analyzed at three damage limit states,i.e.,immediate occupancy,life safety,and collapse prevention.In addition,the effect of characterization methods of bidirectional ground motion intensity on the record-to-record variability is investigated.It is found that the damage limit state of the structure has an important influence on the applicability of the ground motion IM.The S_(a)(T_(1))-based IMs,considering the effect of softened period,can maintain lower record-to-record variability in the three limit states,and the S_(a)(T_(1))-based IMs,considering the effect of higher modes,do not show their advantage over S_(a)(T_(1)).Furthermore,the optimal multiplier C and exponentαin the dual-parameter ground motion IM are proposed to obtain a lower record-to-record variability in the fragility analysis of different damage limit state.Finally,the improved dual-parameter ground motion IM is applied in the risk assessment of the 8-story frame structure.
基金the partial financial support from Kwang-Hua Fund for College of Civil Engineering,Tongji Universitythe National Natural Science Foundation of China(Grant No.51078274,51021140006)
文摘Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenehuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.
基金NSFC program (No. 50678161)the National Major Basic Research 973 Program Under Grant No. 2007CB714205+1 种基金the Science and Technology Support Program Under Grant No. 2006BAC13B02-0301 of the Ministry of Science and Technology of Chinathe Basic Science Research Foundation Program through Institute of Engineering Mechanics, CEA
文摘In this paper, analytical results from 3D temporal characteristics of the responses of an RC frame building subjected to both a large aflershock and the main shock of Wenchuan M8.0 earthquake are presented. The ground motion records from the main shock were obtained from three nearby stations. The acceleration records were analyzed in terms of instantaneous tangential acceleration αv normal acceleration αN, Euclidean norm of acceleration vector lal, velocity vector |v|, displacement vector |d|, temporal curvature κ,κt, and temporal torsion γ and γt.Results of the kinematic relationship between the above factors and some additional in depth information obtained from extensive analyses are provided and discussed.
基金The research was funded by the Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration(No.2019A01)the Nation Key R&D Program of China(No.2018YFC1504602)the Heilongjiang Touyan Innovation Team Program.
文摘Frequent aftershocks often follow a strong mainshock.They can significantly increase cumulative damage to a structure.A model of a five-story reinforced concrete frame structure was designed and a nonlinear mathematical model of the structure was developed to investigate the damage states resulting from different mainshock-aftershock sequences.Mainshock-aftershock sequences consisting of one of three recorded mainshocks combined with one of five recorded aftershocks were created for input to the mathematical model.Inelastic energy dissipation and the Park-Ang damage index were used as measures of cumulative damage to the structure.The results demonstrate that consideration of only the single mainshock ground motion in seismic building design can result in the design and construction of unsafe buildings.Total cumulative damage to a structure is caused by the combination of damage states resulting from the mainshock and the aftershock(s).
文摘On the 2011 off the Pacific Coast of Tohoku Earthquake, gymnasium buildings exhibited the unexpected structural damages, which prevented a use as evacuation shelters in during- and post-disaster periods. The major failure occurr<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ing</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> on the connection between the RC column top and steel roof as well as the cracks in the RC column base w</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> observed during the emergent inspection. According to the earlier studies, it was implied that the presence of the slotted hole possibly deteriorates the seismic capacity;however, the length of slotted hole was fixed at a certain value. Facing this concern, this research attempts to clarify the influence of the slotted hole length through a comprehensive parametric study by pushover and seismic response analyses. In conclusion, it has been discovered that the slotted hole deteriorates the seismic capacity for the connection failure up to almost 50% of that without slotted hole. Moreover, the discrepancy of characteristics obtained by the static and dynamic analyses is originated by means of the presence of slotted hole. This slotted hole effect should be noted by structural engineers and researchers to provide the adequate seismic diagnosis and strengthening.</span></span></span>