The China initiative Accelerator Driven System,CiADS,physics design adopts 162.5 MHz,325 MHz,and 650 MHz cavities,which are driven by the corresponding radio frequency(RF)power system,requiring frequency translation f...The China initiative Accelerator Driven System,CiADS,physics design adopts 162.5 MHz,325 MHz,and 650 MHz cavities,which are driven by the corresponding radio frequency(RF)power system,requiring frequency translation front-end for the RF station.For that application,a general-purpose design front-end prototype has been developed to evaluate the multi-frequency point supported design feasibility.The difficult parts to achieve the requirements of the general-purpose design are reasonable device selection and balanced design.With a carefully selected low-noise wide-band RF mixer and amplifier to balance the performance of multi-frequency supported down-conversion,specially designed LO distribution net to increase isolation between adjacent channels,and external band-pass filter to realize expected up-conversion frequencies,high maintenance and modular front-end generalpurpose design has been implemented.Results of standard parameters show an R2 value of at least 99.991%in the range of-60-10 dBm for linearity,up to 18 dBm for P1dB,and up to 89 dBc for cross talk between adjacent channels.The phase noise spectrum is lower than 80 dBc in the range of 0-1 MHz;cumulative phase noise is 0.006°;and amplitude and phase stability are 0.022%and 0.034°,respectively.展开更多
RF circuit board has a significant impact on performance of the Digital Beam Position Monitor (DBPM) in storage ring of a synchrotron radiation facility.In this paper,a front-end RF board is designed for DBPM,and sche...RF circuit board has a significant impact on performance of the Digital Beam Position Monitor (DBPM) in storage ring of a synchrotron radiation facility.In this paper,a front-end RF board is designed for DBPM,and schematics of the RF board and the test results are given.In view of the inevitable inconsistency in the multi-channel circuit,a calibration circuit is designed to reduce such an influence.The test results show that the calibration method is useful for beam current dependence which is sensitive to channels inconsistency.展开更多
The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect ...The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect in rapid-cycling synchrotrons owing to the increased beam intensity. To satisfy the requirements of dual-harmonic acceleration, a new radiofrequency(RF) system based on a magnetic alloy-loaded cavity is proposed. This paper presents design considerations and experimental results regarding the performance evaluation of the proposed RF system through high-power tests and beam commissioning. The test results demonstrate that the RF system satisfies the desired specifications and affords significant benefits for CSNS-Ⅱ.展开更多
文摘The China initiative Accelerator Driven System,CiADS,physics design adopts 162.5 MHz,325 MHz,and 650 MHz cavities,which are driven by the corresponding radio frequency(RF)power system,requiring frequency translation front-end for the RF station.For that application,a general-purpose design front-end prototype has been developed to evaluate the multi-frequency point supported design feasibility.The difficult parts to achieve the requirements of the general-purpose design are reasonable device selection and balanced design.With a carefully selected low-noise wide-band RF mixer and amplifier to balance the performance of multi-frequency supported down-conversion,specially designed LO distribution net to increase isolation between adjacent channels,and external band-pass filter to realize expected up-conversion frequencies,high maintenance and modular front-end generalpurpose design has been implemented.Results of standard parameters show an R2 value of at least 99.991%in the range of-60-10 dBm for linearity,up to 18 dBm for P1dB,and up to 89 dBc for cross talk between adjacent channels.The phase noise spectrum is lower than 80 dBc in the range of 0-1 MHz;cumulative phase noise is 0.006°;and amplitude and phase stability are 0.022%and 0.034°,respectively.
基金Supported by 100 Talents Program of The Chinese Academy of Sciences
文摘RF circuit board has a significant impact on performance of the Digital Beam Position Monitor (DBPM) in storage ring of a synchrotron radiation facility.In this paper,a front-end RF board is designed for DBPM,and schematics of the RF board and the test results are given.In view of the inevitable inconsistency in the multi-channel circuit,a calibration circuit is designed to reduce such an influence.The test results show that the calibration method is useful for beam current dependence which is sensitive to channels inconsistency.
基金This work was supported by funds from the National Natural Science Foundation of China(Nos.11875270,U1832210,12205317)Youth Innovation Promotion Association CAS(No.2018015)Guangdong Basic and Applied Basic Research Foundation(No.2019B1515120046).
文摘The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect in rapid-cycling synchrotrons owing to the increased beam intensity. To satisfy the requirements of dual-harmonic acceleration, a new radiofrequency(RF) system based on a magnetic alloy-loaded cavity is proposed. This paper presents design considerations and experimental results regarding the performance evaluation of the proposed RF system through high-power tests and beam commissioning. The test results demonstrate that the RF system satisfies the desired specifications and affords significant benefits for CSNS-Ⅱ.