This article examines the influence of seawater temperature and total dissolved solids (TDS) on reverse osmosis (RO) desalination in the Arabian Gulf region, with a focus on the impact of climate change. The study hig...This article examines the influence of seawater temperature and total dissolved solids (TDS) on reverse osmosis (RO) desalination in the Arabian Gulf region, with a focus on the impact of climate change. The study highlights the changes in seawater temperature and TDS levels over the years and discusses their effects on the efficiency and productivity of RO desalination plants. It emphasizes the importance of monitoring TDS levels and controlling seawater temperature to optimize water production. The article also suggests various solutions, including intensive pre-treatment, development of high-performance membranes, exploration of alternative water sources, and regulation of discharges into the Gulf, to ensure sustainable water supply in the face of rising TDS levels and seawater temperature. Further research and comprehensive monitoring are recommended to understand the implications of these findings and develop effective strategies for the management of marine resources in the Arabian Gulf.展开更多
Certain areas in Senegal have a serious problem of high fluoride and salinity in underground water because of soil properties. This water currently used for drink has a bad taste on consumption and caused diseases lik...Certain areas in Senegal have a serious problem of high fluoride and salinity in underground water because of soil properties. This water currently used for drink has a bad taste on consumption and caused diseases like dental fluorosis and skeletal fluorosis. A membrane filtration plant constructed by Pall Corporation was improved through nanofiltration (NF) and Low Pressure Reverse Osmosis (LPRO). Both NF and LPRO membranes were shown applicable for salinity and fluoride ions removal from brackish and high fluorinated drinking water in a remote community. The NF membrane has given a fluorine retention rate varying between 63.3% and 71% while the LPRO membrane allow to reach 97 to 98.9% for fluorine rejection. Highest salinity rejection rates expressed through conductivity measurements are around 46% and 97% for respectively NF and LPRO.展开更多
Brackish water (BW) desalination is a primary path to relieve the shortage of water. As one of the BW desalination methods, reverse osmosis (RO) technology has advantage for both technology and process procedure. The ...Brackish water (BW) desalination is a primary path to relieve the shortage of water. As one of the BW desalination methods, reverse osmosis (RO) technology has advantage for both technology and process procedure. The expounding of this research studied or reviewed recent years, reverse osmosis membrane, energy recovery, new energy and application technology in BW desalination of RO at home and abroad. Wind power and solar energy can be combined with energy recovery device for RO. The research also explains that BW desalination by RO is practical and feasible in some areas in China.展开更多
Reverse Osmosis (RO) desalination plants are highly nonlinear multi-input-multioutput systems that are affected by uncertainties, constraints and some physical phenomena such as membrane fouling that are mathematicall...Reverse Osmosis (RO) desalination plants are highly nonlinear multi-input-multioutput systems that are affected by uncertainties, constraints and some physical phenomena such as membrane fouling that are mathematically difficult to describe. Such systems require effective control strategies that take these effects into account. Such a control strategy is the nonlinear model predictive (NMPC) controller. However, an NMPC depends very much on the accuracy of the internal model used for prediction in order to maintain feasible operating conditions of the RO desalination plant. Recurrent Neural Networks (RNNs), especially the Long-Short-Term Memory (LSTM) can capture complex nonlinear dynamic behavior and provide long-range predictions even in the presence of disturbances. Therefore, in this paper an NMPC for a RO desalination plant that utilizes an LSTM as the predictive model will be presented. It will be tested to maintain a given permeate flow rate and keep the permeate concentration under a certain limit by manipulating the feed pressure. Results show a good performance of the system.展开更多
For further reducing the load of subsequent processing,the activated carbon adsorption method was used to remove organic compounds from reverse osmosis water concentrate,and the influence of variety of activated carbo...For further reducing the load of subsequent processing,the activated carbon adsorption method was used to remove organic compounds from reverse osmosis water concentrate,and the influence of variety of activated carbon,residence time,dosage of activated carbon and p H on the removal rate of COD was studied.The results show that the removal rate of COD was up to 61.8%under the conditions of influent p H=6,400 ml water,30 min of residence time and 1.5 g of 2#activated carbon as the adsorbent.In the dynamic adsorption experiment and field application,the adsorption tower was loaded with 40 tons of 2#activated carbon,and the inflow of influent water was 100 m^3/h;average COD was 142 mg/L,and p H was 8.04;the residence time was 36 min.Under the above conditions,when effluent COD was less than 60 mg/L,the adsorption capacity of activated carbon was up to 1330 m^3/t.展开更多
Enhancing the water permeation while maintaining high salt rejection of existing reverse osmosis(RO)membranes remains a considerable challenge.Herein,we proposed to introduce polymer of intrinsic microporosity,PIM-1,i...Enhancing the water permeation while maintaining high salt rejection of existing reverse osmosis(RO)membranes remains a considerable challenge.Herein,we proposed to introduce polymer of intrinsic microporosity,PIM-1,into the selective layer of reverse osmosis membranes to break the trade-off effect between permeability and selectivity.A water-soluble a-LPIM-1 of low-molecular-weight and hydroxyl terminals was synthesized.These designed characteristics endowed it with high solubility and reactivity.Then it was mixed with m-phenylenediamine and together served as aqueous monomer to react with organic monomer of trimesoyl chloride via interfacial polymerization.The characterization results exhibited that more“nodule”rather than“leaf”structure formed on RO membrane surface,which indicated that the introduction of the high free-volume of a-LPIM-1 with three dimensional twisted and folded structure into the selective layer effectively caused the frustrated packing between polymer chains.In virtue of this effect,even with reduced surface roughness and unchanged layer thickness,the water permeability of prepared reverse osmosis membranes increased 2.1 times to 62.8 L·m^(-2)·h^(-1) with acceptable Na Cl rejection of 97.6%.This attempt developed a new strategy to break the trade-off effect faced by traditional polyamide reverse osmosis membranes.展开更多
Chronic Kidney Disease with unknown etiology (CKDu) is one of the crucial health issues in North Central, Uva, North Western, North, Central, and Eastern Provinces of Sri Lanka and incapacitates the kidney function. T...Chronic Kidney Disease with unknown etiology (CKDu) is one of the crucial health issues in North Central, Uva, North Western, North, Central, and Eastern Provinces of Sri Lanka and incapacitates the kidney function. The main source for the CKDu has not yet been identified, though many scientists believed that the number of certain drinking water quality parameters is changed due to the contamination of water sources by agricultural activities. Hence, the government of Sri Lanka introduces electrically driven Brackish Water Reverse Osmosis (BWRO) plants with a capacity of 10 tones/day to supply safe drinking water for the impacted community though it is an energy-intensive process. Concurrently, a smaller version of an electrically driven BWRO plant was introduced to the rural farming community for their domestic use. However, it was not practically worked out due to various reasons such as high cost, unavailability of electrical power supply for those villages. In this study, an economical air operated domestic use BWRO plant with zero-emission was designed. This anticipated system significantly reduces the government expenditures to subsidize the water purification cost by 50% of the existing expenses. Besides, simple payback time was found to be 2.5 years, and the benefit-cost ratio to be more than 1. Evaluating the performance with the conventional values, it comprehends with more sustainable and economically viable system compared to the existing method of water purification.展开更多
The alarming water and energy crisis in many regions of the world can be eased by combining renewable energy with desalination technologies. The ADIRA project funded by the EU looked for demonstrating the feasibility ...The alarming water and energy crisis in many regions of the world can be eased by combining renewable energy with desalination technologies. The ADIRA project funded by the EU looked for demonstrating the feasibility of water desalination in areas around the Mediterranean by installing a number of autonomous desalination systems (ADS) which are able to convert brackish or seawater into potable water for the needs of small communities. Within the activities of the ADIRA project a reverse osmosis unit powered by photovoltaic electricity was installed in a village in the northern part of Jordan with a capacity of 0.5 m3/day. The system was composed of a softener, reverse osmosis unit, PV panels (432 Wp) and storage batteries. Residential type “OSMONICS” membrane (TFM-100) was utilized in the RO unit. Field tests were performed on brackish water (1700 mg/L total dissolved solids (TDS)). This paper sheds the light on the process flow diagram, sizing of the system main components and presents some of the results obtained.展开更多
When designing and building an optimal reverse osmosis (RO) desalination plant, it is important that engineers select effective membrane parameters for optimal application performance. The membrane selection can deter...When designing and building an optimal reverse osmosis (RO) desalination plant, it is important that engineers select effective membrane parameters for optimal application performance. The membrane selection can determine the success or failure of the entire desalination operation. The objective of this work is to review available membrane types and design parameters that can be selected for optimal application to yield the highest potential for plant operations. Factors such as osmotic pressure, water flux values, and membrane resistance will all be evaluated as functions of membrane parameters. The optimization of these parameters will be determined through the deployment of the solution-diffusion model devolved from the Maxwell Stephan Equation. When applying the solution-diffusion model to evaluate RO membranes, the Maxwell Stephan Equation provides mathematical analysis through which the steps for mass transfer through a RO membrane may be observed and calculated. A practical study of the use of the solution-diffusion model will be discussed. This study uses the diffusion-solution model to evaluate the effectiveness of a variety of Toray RO membranes. This practical application confirms two principal hypotheses when using the diffusion-solution model for membrane evaluation. First, there is an inverse relationship between membrane and water flux rate. Second, there is a proportional linear relationship between overall water flux rate and the applied pressure across a membrane.展开更多
Photovoltaic based reverse osmosis desalination systems (PV/RO) present an effective method of water desalination especially in remote areas. The increase of the feed water temperature leads to an amelioration of the ...Photovoltaic based reverse osmosis desalination systems (PV/RO) present an effective method of water desalination especially in remote areas. The increase of the feed water temperature leads to an amelioration of the plant performances. Photovoltaic Thermal Collector (PV/T) represents an ideal power source as it provides both electric and thermal energies for the reverse osmosis process. Nevertheless, PV/T based RO plants should be controlled in order to solve operation problems related to electrical efficiency, reverse osmosis membrane, produced water and the rejected salts. This paper suggests a fuzzy logic controller for the flow rate of the circulating fluid into the PV/T collectors so as to ameliorate the system performances. The designed controller has improved the PV/T field electrical efficiency and preserved the reverse osmosis membrane which upgrades the system productivity. LABVIEW software is used to simulate the controlled system and validate the effectiveness of the controller.展开更多
Thin-film composite(TFC) reverse osmosis(RO) membranes are playing the dominating role in desalination.Tremendous efforts have been put in the studies on the polyamide selective layers. However, the effect of the subs...Thin-film composite(TFC) reverse osmosis(RO) membranes are playing the dominating role in desalination.Tremendous efforts have been put in the studies on the polyamide selective layers. However, the effect of the substrate layers is far less concerned. In this review, we summarize the works that consider the impacts of the substrates, including pore sizes, surface hydrophilicity, on the processes of interfacial polymerization and consequently on the morphologies of the active layers and on final RO performances of the composite membranes. All the works indicate that the pore sizes and surface hydrophilicity of the substrate evidently influence the RO performances of the composite membranes. Unfortunately, we find that the observations and understandings on the substrate effect are frequently varied from case to case because of the lack of substrates with uniform pores and surface chemistries. We suggest using track-etched membranes or anodized alumina membranes having relatively uniform pores and functionalizable pore walls as model substrates to elucidate the substrate effect.Moreover, we argue that homoporous membranes derived from block copolymers have the potential to be used as substrates for the large-scale production of high-performances TFC RO membranes.展开更多
Fouling phenomenon is considered among the major reasons that cause significant increase of operating cost of desalination plants equipped with reverse osmosis(RO)membranes.This phenomenon is studied in the present wo...Fouling phenomenon is considered among the major reasons that cause significant increase of operating cost of desalination plants equipped with reverse osmosis(RO)membranes.This phenomenon is studied in the present work in the case of RO polyamide aromatic membranes using model seawater containing inorganic salts and colloidal compounds.Different solubility conditions of CaCO3 and CaSO4 were applied to study RO performances with and without colloid presence.During experiments,the membrane permeate fluxes were continuously monitored.Moreover,studies of chemical composition,structure,and morphology of the materials deposited on the membrane surface were conducted using energy dispersive microanalysis(EDS)X-ray diffraction and scanning electronic microscopy(SEM).Results show that in conditions of calcium carbonate oversaturation there is a reduction in the permeate flow of 11.2%due to fouling of the membrane by the precipitation of this compound.While in the same conditions of calcium sulphate oversaturation the reduction of the flow is 5%,so we can conclude that in conditions of oversaturation of both salts,calcium carbonate produces a greater fouling of the membrane that in its view causes greater decrease in the flow of permeate.All this based on the results of the test with both salts in oversaturated conditions.Resulting in the formation of calcite and gypsum crystals onto the membranes as XRD analyses stated.Additional presence of colloidal silica in those conditions intensifies strongly the fouling,leading until to 24.1%of permeate flux decrease.展开更多
In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continue...In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continues to rapidly grow in the world.Nanofiltration(NF)and reverse osmosis(RO)as the highefficient,low energy consumption,and environmental friendly membrane separation techniques,show great promise in the application of biomedical separation field.The chemical compositions,microstructures and surface properties of NF/RO membranes determine the separation accuracy,efficiency and operation cost in their applications.Accordingly,recent studies have focused on tuning the structures and tailoring the performance of NF/RO membranes via the design and synthesis of various advanced membrane materials,and exploring universal and convenient membrane preparation strategies,with the objective of promoting the better and faster development of NF/RO membrane separation technology in the biomedical separation field.This paper reviews the recent studies on the NF/RO membranes constructed with various materials,including the polymeric materials,different dimensional inorganic/organic nanomaterials,porous polymeric materials and metal coordination polymers,etc.Moreover,the influence of membrane chemical compositions,interior microstructures,and surface characteristics on the separation performance of NF/RO membranes,are comprehensively discussed.Subsequently,the applications of NF/RO membranes in biomedical separation field are systematically reported.Finally,the perspective for future challenges of NF/RO membrane separation techniques in this field is discussed.展开更多
Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutral...Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutralization, clari-flocculation and biological processes are followed to clean the effluents before feeding to RO membrane modules. The characteristics of untreated composite effluents such as pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total dissolved solids (TDS), and total chromium were in the range of 4.00-4.60, 680-3600 mg/L, 1698-7546 mg/L, 980-1480 mg/L, 4200-14500 mg/L, and 26.4-190 mg/L, respectively. Inorganic ions like Ca2+, Na+, Cl– and SO42– were found more in the wastewaters. Conventional treatments significantly removed the organic pollutants however failed to remove dissolved inorganic salts. Membrane technology removed the salts as well as remaining organic pollutants and the product water is reused in the process. The studied tanneries (5 numbers) have achieved 93-98%, 92-99% and 91-96% removal of TDS, sodium and chloride, respectively. Seventy to eighty five percentage of wastewater was recovered and recycled in the industrial processes. The rejects are subject to either solar evaporation system or Multiple Effect Evaporation (MEE) technology. The resulting salts are collected in polythene bags and disposed into scientifically managed secured land fill (SLF) site. The cost of wastewater treatment for operation and maintenances of RO including the pre-treatments (conventional methods) is INR 100-110 m-3.展开更多
Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using...Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using other much cheaper scale inhibitors, RO running cost will decrease greatly. The present paper investigated the inhi- bition of CaCO3 precipitation by zinc ions in RO system. The results show that the zinc ion concentration of 2mg?L-1 was able to exert a marked suppression effect on both bulk precipitation of CaCO3 and on membrane scaling on waters of moderate hardness.展开更多
Aims to investigate the performance of the pilot-scale reclamation plant for coal gasification wastewater( CGW) using ultrafiltration and reverse osmosis with appropriate pretreatment alternatives,different pre-treatm...Aims to investigate the performance of the pilot-scale reclamation plant for coal gasification wastewater( CGW) using ultrafiltration and reverse osmosis with appropriate pretreatment alternatives,different pre-treatment alternatives- coagulation,adsorption,and ozonation methods were employed to treat the secondary effluent of coal gasification wastewater( SECGW) in a pilot-scale pressurized membrane system. The performance was compared to choose the most suitable pre-treatment alternative for the SECGW reclamation.Ozone reaction achieved highest COD removal efficiency( 79.6%- 91.0%),resulting in the stable normalized parameters of the subsequent ultrafiltration and reverse osmoses. In contrast,the coagulation and adsorption processes achieved only 32. 8%- 45. 7% and 53. 1%- 64. 6% decreases in COD,respectively. The residual organic pollutants in the reverse osmosis feed water led to an increase in normalized pressure drop and a decrease in normalized permeability( or membrane transference coefficient). The hydrophobic fraction was the main constituent( approx. 70% of DOC) in pretreated SECGW, and the hydrophobic-neutral fraction contributed mostly to the UV absorbance( 53%). Fluorescence excitation emission matrices revealed that ozonation removed most of the hydrophobic and aromatic proteins such as tyrosine and tryptophan which dominated in raw wastewater. The recalcitrant compounds such as phenolic compounds, heterocyclic compounds,especially long-chain hydrocarbons,which were easily attached to the membrane surface and contributed to organic fouling,could be oxidized and mineralized by ozone. Among the three pretreatments,ozonation showed highest removal efficiencies of hydrophobic and aromatic proteins,therefore resulting in highest normalized permeability.展开更多
文摘This article examines the influence of seawater temperature and total dissolved solids (TDS) on reverse osmosis (RO) desalination in the Arabian Gulf region, with a focus on the impact of climate change. The study highlights the changes in seawater temperature and TDS levels over the years and discusses their effects on the efficiency and productivity of RO desalination plants. It emphasizes the importance of monitoring TDS levels and controlling seawater temperature to optimize water production. The article also suggests various solutions, including intensive pre-treatment, development of high-performance membranes, exploration of alternative water sources, and regulation of discharges into the Gulf, to ensure sustainable water supply in the face of rising TDS levels and seawater temperature. Further research and comprehensive monitoring are recommended to understand the implications of these findings and develop effective strategies for the management of marine resources in the Arabian Gulf.
文摘Certain areas in Senegal have a serious problem of high fluoride and salinity in underground water because of soil properties. This water currently used for drink has a bad taste on consumption and caused diseases like dental fluorosis and skeletal fluorosis. A membrane filtration plant constructed by Pall Corporation was improved through nanofiltration (NF) and Low Pressure Reverse Osmosis (LPRO). Both NF and LPRO membranes were shown applicable for salinity and fluoride ions removal from brackish and high fluorinated drinking water in a remote community. The NF membrane has given a fluorine retention rate varying between 63.3% and 71% while the LPRO membrane allow to reach 97 to 98.9% for fluorine rejection. Highest salinity rejection rates expressed through conductivity measurements are around 46% and 97% for respectively NF and LPRO.
文摘Brackish water (BW) desalination is a primary path to relieve the shortage of water. As one of the BW desalination methods, reverse osmosis (RO) technology has advantage for both technology and process procedure. The expounding of this research studied or reviewed recent years, reverse osmosis membrane, energy recovery, new energy and application technology in BW desalination of RO at home and abroad. Wind power and solar energy can be combined with energy recovery device for RO. The research also explains that BW desalination by RO is practical and feasible in some areas in China.
文摘Reverse Osmosis (RO) desalination plants are highly nonlinear multi-input-multioutput systems that are affected by uncertainties, constraints and some physical phenomena such as membrane fouling that are mathematically difficult to describe. Such systems require effective control strategies that take these effects into account. Such a control strategy is the nonlinear model predictive (NMPC) controller. However, an NMPC depends very much on the accuracy of the internal model used for prediction in order to maintain feasible operating conditions of the RO desalination plant. Recurrent Neural Networks (RNNs), especially the Long-Short-Term Memory (LSTM) can capture complex nonlinear dynamic behavior and provide long-range predictions even in the presence of disturbances. Therefore, in this paper an NMPC for a RO desalination plant that utilizes an LSTM as the predictive model will be presented. It will be tested to maintain a given permeate flow rate and keep the permeate concentration under a certain limit by manipulating the feed pressure. Results show a good performance of the system.
基金Supported by Industrial Water Treatment Engineering Technology Innovation Team,Shaanxi Science and Technology Innovation Team(2015KCT-22)
文摘For further reducing the load of subsequent processing,the activated carbon adsorption method was used to remove organic compounds from reverse osmosis water concentrate,and the influence of variety of activated carbon,residence time,dosage of activated carbon and p H on the removal rate of COD was studied.The results show that the removal rate of COD was up to 61.8%under the conditions of influent p H=6,400 ml water,30 min of residence time and 1.5 g of 2#activated carbon as the adsorbent.In the dynamic adsorption experiment and field application,the adsorption tower was loaded with 40 tons of 2#activated carbon,and the inflow of influent water was 100 m^3/h;average COD was 142 mg/L,and p H was 8.04;the residence time was 36 min.Under the above conditions,when effluent COD was less than 60 mg/L,the adsorption capacity of activated carbon was up to 1330 m^3/t.
基金supported by Zhejiang Provincial Natural Science Foundation of China (LZ20B060001)National Natural Science Foundation of China (22008208&21908192)China Postdoctoral Science Foundation (2019TQ0276)。
文摘Enhancing the water permeation while maintaining high salt rejection of existing reverse osmosis(RO)membranes remains a considerable challenge.Herein,we proposed to introduce polymer of intrinsic microporosity,PIM-1,into the selective layer of reverse osmosis membranes to break the trade-off effect between permeability and selectivity.A water-soluble a-LPIM-1 of low-molecular-weight and hydroxyl terminals was synthesized.These designed characteristics endowed it with high solubility and reactivity.Then it was mixed with m-phenylenediamine and together served as aqueous monomer to react with organic monomer of trimesoyl chloride via interfacial polymerization.The characterization results exhibited that more“nodule”rather than“leaf”structure formed on RO membrane surface,which indicated that the introduction of the high free-volume of a-LPIM-1 with three dimensional twisted and folded structure into the selective layer effectively caused the frustrated packing between polymer chains.In virtue of this effect,even with reduced surface roughness and unchanged layer thickness,the water permeability of prepared reverse osmosis membranes increased 2.1 times to 62.8 L·m^(-2)·h^(-1) with acceptable Na Cl rejection of 97.6%.This attempt developed a new strategy to break the trade-off effect faced by traditional polyamide reverse osmosis membranes.
文摘Chronic Kidney Disease with unknown etiology (CKDu) is one of the crucial health issues in North Central, Uva, North Western, North, Central, and Eastern Provinces of Sri Lanka and incapacitates the kidney function. The main source for the CKDu has not yet been identified, though many scientists believed that the number of certain drinking water quality parameters is changed due to the contamination of water sources by agricultural activities. Hence, the government of Sri Lanka introduces electrically driven Brackish Water Reverse Osmosis (BWRO) plants with a capacity of 10 tones/day to supply safe drinking water for the impacted community though it is an energy-intensive process. Concurrently, a smaller version of an electrically driven BWRO plant was introduced to the rural farming community for their domestic use. However, it was not practically worked out due to various reasons such as high cost, unavailability of electrical power supply for those villages. In this study, an economical air operated domestic use BWRO plant with zero-emission was designed. This anticipated system significantly reduces the government expenditures to subsidize the water purification cost by 50% of the existing expenses. Besides, simple payback time was found to be 2.5 years, and the benefit-cost ratio to be more than 1. Evaluating the performance with the conventional values, it comprehends with more sustainable and economically viable system compared to the existing method of water purification.
文摘The alarming water and energy crisis in many regions of the world can be eased by combining renewable energy with desalination technologies. The ADIRA project funded by the EU looked for demonstrating the feasibility of water desalination in areas around the Mediterranean by installing a number of autonomous desalination systems (ADS) which are able to convert brackish or seawater into potable water for the needs of small communities. Within the activities of the ADIRA project a reverse osmosis unit powered by photovoltaic electricity was installed in a village in the northern part of Jordan with a capacity of 0.5 m3/day. The system was composed of a softener, reverse osmosis unit, PV panels (432 Wp) and storage batteries. Residential type “OSMONICS” membrane (TFM-100) was utilized in the RO unit. Field tests were performed on brackish water (1700 mg/L total dissolved solids (TDS)). This paper sheds the light on the process flow diagram, sizing of the system main components and presents some of the results obtained.
文摘When designing and building an optimal reverse osmosis (RO) desalination plant, it is important that engineers select effective membrane parameters for optimal application performance. The membrane selection can determine the success or failure of the entire desalination operation. The objective of this work is to review available membrane types and design parameters that can be selected for optimal application to yield the highest potential for plant operations. Factors such as osmotic pressure, water flux values, and membrane resistance will all be evaluated as functions of membrane parameters. The optimization of these parameters will be determined through the deployment of the solution-diffusion model devolved from the Maxwell Stephan Equation. When applying the solution-diffusion model to evaluate RO membranes, the Maxwell Stephan Equation provides mathematical analysis through which the steps for mass transfer through a RO membrane may be observed and calculated. A practical study of the use of the solution-diffusion model will be discussed. This study uses the diffusion-solution model to evaluate the effectiveness of a variety of Toray RO membranes. This practical application confirms two principal hypotheses when using the diffusion-solution model for membrane evaluation. First, there is an inverse relationship between membrane and water flux rate. Second, there is a proportional linear relationship between overall water flux rate and the applied pressure across a membrane.
文摘Photovoltaic based reverse osmosis desalination systems (PV/RO) present an effective method of water desalination especially in remote areas. The increase of the feed water temperature leads to an amelioration of the plant performances. Photovoltaic Thermal Collector (PV/T) represents an ideal power source as it provides both electric and thermal energies for the reverse osmosis process. Nevertheless, PV/T based RO plants should be controlled in order to solve operation problems related to electrical efficiency, reverse osmosis membrane, produced water and the rejected salts. This paper suggests a fuzzy logic controller for the flow rate of the circulating fluid into the PV/T collectors so as to ameliorate the system performances. The designed controller has improved the PV/T field electrical efficiency and preserved the reverse osmosis membrane which upgrades the system productivity. LABVIEW software is used to simulate the controlled system and validate the effectiveness of the controller.
基金Supported by the National Basic Research Program of China(2015CB655301)the Natural Science Foundation of Jiangsu Province(BK20150063)the Project of Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)
文摘Thin-film composite(TFC) reverse osmosis(RO) membranes are playing the dominating role in desalination.Tremendous efforts have been put in the studies on the polyamide selective layers. However, the effect of the substrate layers is far less concerned. In this review, we summarize the works that consider the impacts of the substrates, including pore sizes, surface hydrophilicity, on the processes of interfacial polymerization and consequently on the morphologies of the active layers and on final RO performances of the composite membranes. All the works indicate that the pore sizes and surface hydrophilicity of the substrate evidently influence the RO performances of the composite membranes. Unfortunately, we find that the observations and understandings on the substrate effect are frequently varied from case to case because of the lack of substrates with uniform pores and surface chemistries. We suggest using track-etched membranes or anodized alumina membranes having relatively uniform pores and functionalizable pore walls as model substrates to elucidate the substrate effect.Moreover, we argue that homoporous membranes derived from block copolymers have the potential to be used as substrates for the large-scale production of high-performances TFC RO membranes.
基金funded by the Project AM11/04 of the Junta de Andalucía(Spain)。
文摘Fouling phenomenon is considered among the major reasons that cause significant increase of operating cost of desalination plants equipped with reverse osmosis(RO)membranes.This phenomenon is studied in the present work in the case of RO polyamide aromatic membranes using model seawater containing inorganic salts and colloidal compounds.Different solubility conditions of CaCO3 and CaSO4 were applied to study RO performances with and without colloid presence.During experiments,the membrane permeate fluxes were continuously monitored.Moreover,studies of chemical composition,structure,and morphology of the materials deposited on the membrane surface were conducted using energy dispersive microanalysis(EDS)X-ray diffraction and scanning electronic microscopy(SEM).Results show that in conditions of calcium carbonate oversaturation there is a reduction in the permeate flow of 11.2%due to fouling of the membrane by the precipitation of this compound.While in the same conditions of calcium sulphate oversaturation the reduction of the flow is 5%,so we can conclude that in conditions of oversaturation of both salts,calcium carbonate produces a greater fouling of the membrane that in its view causes greater decrease in the flow of permeate.All this based on the results of the test with both salts in oversaturated conditions.Resulting in the formation of calcite and gypsum crystals onto the membranes as XRD analyses stated.Additional presence of colloidal silica in those conditions intensifies strongly the fouling,leading until to 24.1%of permeate flux decrease.
基金financially supported by the Provincial Key Research and Development Program of Zhejiang Province(2021C01173)the National Natural Science Foundation of China(21975221 and 21776252)。
文摘In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continues to rapidly grow in the world.Nanofiltration(NF)and reverse osmosis(RO)as the highefficient,low energy consumption,and environmental friendly membrane separation techniques,show great promise in the application of biomedical separation field.The chemical compositions,microstructures and surface properties of NF/RO membranes determine the separation accuracy,efficiency and operation cost in their applications.Accordingly,recent studies have focused on tuning the structures and tailoring the performance of NF/RO membranes via the design and synthesis of various advanced membrane materials,and exploring universal and convenient membrane preparation strategies,with the objective of promoting the better and faster development of NF/RO membrane separation technology in the biomedical separation field.This paper reviews the recent studies on the NF/RO membranes constructed with various materials,including the polymeric materials,different dimensional inorganic/organic nanomaterials,porous polymeric materials and metal coordination polymers,etc.Moreover,the influence of membrane chemical compositions,interior microstructures,and surface characteristics on the separation performance of NF/RO membranes,are comprehensively discussed.Subsequently,the applications of NF/RO membranes in biomedical separation field are systematically reported.Finally,the perspective for future challenges of NF/RO membrane separation techniques in this field is discussed.
文摘Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutralization, clari-flocculation and biological processes are followed to clean the effluents before feeding to RO membrane modules. The characteristics of untreated composite effluents such as pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total dissolved solids (TDS), and total chromium were in the range of 4.00-4.60, 680-3600 mg/L, 1698-7546 mg/L, 980-1480 mg/L, 4200-14500 mg/L, and 26.4-190 mg/L, respectively. Inorganic ions like Ca2+, Na+, Cl– and SO42– were found more in the wastewaters. Conventional treatments significantly removed the organic pollutants however failed to remove dissolved inorganic salts. Membrane technology removed the salts as well as remaining organic pollutants and the product water is reused in the process. The studied tanneries (5 numbers) have achieved 93-98%, 92-99% and 91-96% removal of TDS, sodium and chloride, respectively. Seventy to eighty five percentage of wastewater was recovered and recycled in the industrial processes. The rejects are subject to either solar evaporation system or Multiple Effect Evaporation (MEE) technology. The resulting salts are collected in polythene bags and disposed into scientifically managed secured land fill (SLF) site. The cost of wastewater treatment for operation and maintenances of RO including the pre-treatments (conventional methods) is INR 100-110 m-3.
基金Supported by the National Natural Science Foundation of China (20476096, 20776133), Zhejiang Provincial Bureau of Science & Technology (2005C33040) and Bureau of Education (Key Discipline of Environmental Engineering 56310503014).
基金Supported by the National Natural Science Foundation of China (No.20306015) and the Scientific Research Foundation of theState Education Ministry for Returned Overseas Chinese Scholars (No.[2003]406).
文摘Scaling of reverse osmosis (RO) membrane surface is one of the main problems in desalination proc- esses. To mitigate scales, organic anti-scalants are often used. If the dosages of anti-scalants are reduced, by using other much cheaper scale inhibitors, RO running cost will decrease greatly. The present paper investigated the inhi- bition of CaCO3 precipitation by zinc ions in RO system. The results show that the zinc ion concentration of 2mg?L-1 was able to exert a marked suppression effect on both bulk precipitation of CaCO3 and on membrane scaling on waters of moderate hardness.
基金Sponsored by the State Key Laboratory of Urban Water Resource and Environment(Harbin Institute of Technology)(Grant No.2015DX02)
文摘Aims to investigate the performance of the pilot-scale reclamation plant for coal gasification wastewater( CGW) using ultrafiltration and reverse osmosis with appropriate pretreatment alternatives,different pre-treatment alternatives- coagulation,adsorption,and ozonation methods were employed to treat the secondary effluent of coal gasification wastewater( SECGW) in a pilot-scale pressurized membrane system. The performance was compared to choose the most suitable pre-treatment alternative for the SECGW reclamation.Ozone reaction achieved highest COD removal efficiency( 79.6%- 91.0%),resulting in the stable normalized parameters of the subsequent ultrafiltration and reverse osmoses. In contrast,the coagulation and adsorption processes achieved only 32. 8%- 45. 7% and 53. 1%- 64. 6% decreases in COD,respectively. The residual organic pollutants in the reverse osmosis feed water led to an increase in normalized pressure drop and a decrease in normalized permeability( or membrane transference coefficient). The hydrophobic fraction was the main constituent( approx. 70% of DOC) in pretreated SECGW, and the hydrophobic-neutral fraction contributed mostly to the UV absorbance( 53%). Fluorescence excitation emission matrices revealed that ozonation removed most of the hydrophobic and aromatic proteins such as tyrosine and tryptophan which dominated in raw wastewater. The recalcitrant compounds such as phenolic compounds, heterocyclic compounds,especially long-chain hydrocarbons,which were easily attached to the membrane surface and contributed to organic fouling,could be oxidized and mineralized by ozone. Among the three pretreatments,ozonation showed highest removal efficiencies of hydrophobic and aromatic proteins,therefore resulting in highest normalized permeability.