In the present study, comprehensive stress testing of tenatoprazole was carried out according to ICH guide-line Q1A (R2). Tenatoprazole was subjected to stress conditions of hydrolysis, oxidation, photolysis and neutr...In the present study, comprehensive stress testing of tenatoprazole was carried out according to ICH guide-line Q1A (R2). Tenatoprazole was subjected to stress conditions of hydrolysis, oxidation, photolysis and neutral decomposition. Extensive degradation was found to occur in acidic, neutral and oxidative conditions. Mild degradation was observed in basic conditions. The drug is relatively stable in the solid-state. Successful separation of drug from degradation products formed under stress conditions was achieved on a Kromasil C18 column (250 mm × 4.6 mm, 5.0 μ particle size) using methanol: THF: acetate buffer (68:12:20 v/v) pH adjusted to 6.0 with acetic acid as mobile phase, flow rate was 1.0 mL●min–1 and column was maintained at 45°C. Quantification and linearity was achieved at 307 nm over the concentration range of 0.5 - 160 μg●mL–1 for tenatoprazole. The method was validated for specificity, linearity, accuracy, precision, LOD, LOQ and robustness.展开更多
A stability-indicating RP-HPLC method has been developed and validated for simultaneous determination of Valsartan & Hydrochlorothiazide and their impurities in FDC (Fixed Dose Combination) tablet dosage form. The...A stability-indicating RP-HPLC method has been developed and validated for simultaneous determination of Valsartan & Hydrochlorothiazide and their impurities in FDC (Fixed Dose Combination) tablet dosage form. The method was developed using L1 column (250 × 4.6 mm;5 μm) with gradient elution using the mobile phase consisting of solvent-A (0.1% Ortho phosphoric acid) and solvent-B (100% Acetonitrile);the gradient program (T<sub>min</sub>/%B) was set as 0/10, 5/10, 20/60, 40/60, 41/10 and 50/10. The eluted compounds were monitored at 265 nm. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The influence of Acid, Alkaline, Oxidative, Photolytic, Thermal and Humidity stress conditions, on drug product was studied. The limit of quantification results of Valsartan, Hydrochlorothiazide and their impurities are, VAL: 0.303 μg/mL, HCTZ: 0.019 μg/mL, VAL RC-B: 0.085 μg/mL, VAL RC-C: 0.327 μg/mL, HCT RC-A: 0.017 μg/mL, CTZ: 0.080 μg/mL and 5-Chloro HCT: 0.047 μg/mL. The proposed method is suitable for the estimation of Valsartan & Hydrochlorothiazide impurities in tablets dosage form.展开更多
文摘In the present study, comprehensive stress testing of tenatoprazole was carried out according to ICH guide-line Q1A (R2). Tenatoprazole was subjected to stress conditions of hydrolysis, oxidation, photolysis and neutral decomposition. Extensive degradation was found to occur in acidic, neutral and oxidative conditions. Mild degradation was observed in basic conditions. The drug is relatively stable in the solid-state. Successful separation of drug from degradation products formed under stress conditions was achieved on a Kromasil C18 column (250 mm × 4.6 mm, 5.0 μ particle size) using methanol: THF: acetate buffer (68:12:20 v/v) pH adjusted to 6.0 with acetic acid as mobile phase, flow rate was 1.0 mL●min–1 and column was maintained at 45°C. Quantification and linearity was achieved at 307 nm over the concentration range of 0.5 - 160 μg●mL–1 for tenatoprazole. The method was validated for specificity, linearity, accuracy, precision, LOD, LOQ and robustness.
文摘A stability-indicating RP-HPLC method has been developed and validated for simultaneous determination of Valsartan & Hydrochlorothiazide and their impurities in FDC (Fixed Dose Combination) tablet dosage form. The method was developed using L1 column (250 × 4.6 mm;5 μm) with gradient elution using the mobile phase consisting of solvent-A (0.1% Ortho phosphoric acid) and solvent-B (100% Acetonitrile);the gradient program (T<sub>min</sub>/%B) was set as 0/10, 5/10, 20/60, 40/60, 41/10 and 50/10. The eluted compounds were monitored at 265 nm. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The influence of Acid, Alkaline, Oxidative, Photolytic, Thermal and Humidity stress conditions, on drug product was studied. The limit of quantification results of Valsartan, Hydrochlorothiazide and their impurities are, VAL: 0.303 μg/mL, HCTZ: 0.019 μg/mL, VAL RC-B: 0.085 μg/mL, VAL RC-C: 0.327 μg/mL, HCT RC-A: 0.017 μg/mL, CTZ: 0.080 μg/mL and 5-Chloro HCT: 0.047 μg/mL. The proposed method is suitable for the estimation of Valsartan & Hydrochlorothiazide impurities in tablets dosage form.