Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,...Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data.展开更多
Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiograp...Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations.展开更多
Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances i...Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances in technology it is now possible to have digital solutions for radiography problems at a very cost effective, environment friendly and also with better image quality in certain applications when compared to CRF. Rather than using a CRF a computed radiography (CR) uses imaging plates to capture the image. The imaging plate contains photosensitive phosphors which contain the latent image. Later this plate is introduced into a reader which is then converted into a digital image. The major advantage and the cost effective element of this system is the ability to reuse the imaging plates unlike the photographic film where in only a single image can be captured and cannot be reused. The computed radiography drastically reduces the cost by eliminating the use of chemicals like film developers and fixers and also the need for a storage room. It also helps to reduce the costs that are involved in the disposal of wastes due to conventional radiography. This paper investigates whether it is cost effective to use computed radiography over film based system at Al-Batnan Medical Center (BMC), Tobruk, Libya by using Cost Benefit Analysis (CBA). Apart from the initial cost of the CR System, based on the data collected from the center, from the year 2008 to 2012 (until June 2012) a total of 581,566 images were produced with the total cost incurred using film based system being USD 4,652,528. If the same number of images were produced using a CR system the total cost incurred would have been USD 82,600. Taking into consideration the cost of a new CR system to be USD 120,000 the overall cost of producing these images is USD 202,600. It is observed that an amount of USD 4,449,928 could have been saved over the period of 5 years starting from 2008 to 2012 by using the CR system at BMC. Using Cost Benefit Analysis, the average value of the net difference between the costs and benefits for the conventional film based system is ?83.38 where as for the Computed System it is 22.06. Based on the principles of Cost Benefit Analysis it can be concluded that the system with a net positive difference is more cost beneficial than the other. With the help of the above two analysis it can be concluded that the use of computed radiography is definitely more cost effective for use at BMC, when compared to the conventional x-ray radiography.展开更多
Objective: Maxillofacial injuries are one of the commonest injuries encountered. Roentgenographic evaluation of maxillofacial trauma is of prime importance for diagnosis and treatment of these injuries. Study Design: ...Objective: Maxillofacial injuries are one of the commonest injuries encountered. Roentgenographic evaluation of maxillofacial trauma is of prime importance for diagnosis and treatment of these injuries. Study Design: Forty patients were evaluated in the prospective four-year study. We studied and evaluated the demography and diagnostic efficacy of clinical, plain radiography, and computed scan in maxillofacial trauma. Result: Road traffic accidents were the commonest cause of maxillofacial injuries. Patients having multiple fractures, mandibular fractures were the commonest. Conclusion: Computed tomography proved a useful adjunct in midfacial trauma.展开更多
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica...The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone.展开更多
The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mec...The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mechanical grain harvesting.However,conventional BR evaluation and measurement methods have challenges and limitations.Microstructural crack parameters evaluation of maize kernel is of great importance to BR.In this connection,X-ray computed microtomography(μ-CT)has proven to be a quite useful method for the assessment of microstructure,as it provides important microstructural parameters,such as object volume,surface,surface/volume ratio,number of closed pores,and others.X-ray computed microtomography is a non-destructive technique that enables the reuse of samples already measured and also yields bidimensional(2D)cross-sectional images of the sample as well as volume rendering.In this paper,six different maize hybrid genotypes are used as materials,and the BR of the maize kernels of each variety is tested in the field mechanical grain harvesting,and the BR is used as an index for evaluating the breakage resistance of the variety.The crack characteristic parameters of kernel were detected by X-ray micro-computed tomography,and the relationship between the BR and the kernel crack characteristics was analyzed by stepwise regression analysis.Establishing a relationship between crack characteristic parameters and BR of maize is vital for judging breakage resistance.The results of stepwise multiple linear regression(MLR)showed that the crack characteristics of the object surface,number of closed pores,surface of closed pores,and closed porosity percent were significantly correlated to the BR of field mechanical grain harvesting,with the standard partial regression coefficients of–0.998,–0.988,–0.999,and–0.998,respectively.The R2 of this model was 0.999.Results validation showed that the Stepwise MLR Model could well predict the BR of maize based on these four variables.展开更多
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised...Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%.展开更多
A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfe...A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.展开更多
Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collec...Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research.展开更多
Computed radiography(CR)imaging has high irradiation tolerance and it is easy to archive CR images along with other image information by Digital Imaging and Communications in Medicine(DICOM)format,and to process them....Computed radiography(CR)imaging has high irradiation tolerance and it is easy to archive CR images along with other image information by Digital Imaging and Communications in Medicine(DICOM)format,and to process them.CR can be used in radiation Quality Control(QC)task and verification of treatment setting-up.In this paper,the role of high-energy CR in radiation oncology is studied.The patients were imaged by CR system and EPID before radiotherapy.All verification images were acquired with 1–2 MU(Monitor Unit)using 6 MV X-rays.QC for a linac was done with film and high-energy CR to collect the data on daily,weekly and monthly basis.The QC included Multileaf Collimators(MLC)calibration and mechanical iso-centre check.CR was also adapted to verify patient position,the film was used to compare with digitally reconstructed radiographs(DRR)and portal image from EPID. Treatment setting-up was verified based on the result of comparison.High quality verification images could be acquired by the CR system.Comparing to EPID,the results showed that the system was suitable for practical use to acquire daily verification images,and it was useful to fulfill part of quality assurance(QA)in radiation oncology.The quality of image acquired by the high-energy CR system is comparable or even better than DRRs and portal images. The final treatment set-up for the patients could be verified more accurately with the CR system.展开更多
This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray ...This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems.展开更多
In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR ...In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR imaging, such as effect of ratio of target to film(TF) and source to target(ST) distances and X-ray penetration thickness of the composite material were optimized based on clarity and the actual dimensions of the objects. The optimized parameters were used in the FXR imaging of the ballistic event of 9 mm soft projectile on E-glass/epoxy composite. The real time deformation patterns of both the projectile and composite target during the ballistic impact were captured and studied at different time intervals. The notable failure modes of the 10 mm thick target with time include fibre breakage, bulging on the back side, delamination, recovery of the bulging, reverse bulging and its recovery. However, with increase in thickness of the target to 30 mm the only failure mechanism observed is the breaking of fibres. The ballistic impact event was also numerically simulated using commercially available LS-DYNA software. The numerically simulated deformation patterns of the projectile and target at different time intervals are closely matching with the corresponding radiographic images.展开更多
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ...Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.展开更多
Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral ra...Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral range and provide a high spatial and temporal resolution.展开更多
This paper studied the thermal physical properties of foundation materials in the molten salt tank of thermal energy storage system after molten salt leakage by Transient plane source experiment and X-ray computed mic...This paper studied the thermal physical properties of foundation materials in the molten salt tank of thermal energy storage system after molten salt leakage by Transient plane source experiment and X-ray computed microtomography simulation methods.The microstructure,thermal properties and pressure resistance with different particle diameters were addressed.The measured heat conductivities from Transient plane source experiment for three cases are 0.49 W/(m·K),0.48 W/(m·K),and 0.51 W/(m·K),and the porosity is 30.1%,30.7%,and 31.2% respectively.The heat conductivity simulating results of three cases are 0.471 W/(m·K),0.482W/(m·K),and 0.513 W/(m·K).The ratio of difference between the results of simulation and Transient plane source measurement is as low as 1.2%,verifying the reliability of experimental and simulation results to a certain degree.Compared with the heat conductivity of 0.097-0.129 W/(m·K) and porosity of 71.6%-78.9% without leaking salt,the porosity is reduced by more than 50% while the heat conductivity increased by 4 to 5 times after molten salt leakage.This significant increase in heat conductivity has a great impact on security operation,structure design,and modeling of the tank foundation for solar power plants.展开更多
AIM: To determine the diagnostic accuracy and radiation dose of conventional radiography and multidetector computed tomography(MDCT) in suspected scaphoid fractures.METHODS: One hundred twenty-four consecutive patient...AIM: To determine the diagnostic accuracy and radiation dose of conventional radiography and multidetector computed tomography(MDCT) in suspected scaphoid fractures.METHODS: One hundred twenty-four consecutive patients were enrolled in our study who had suffered from a wrist trauma and showed typical clinical symptoms suspicious of an acute scaphoid fracture. All patients had initially undergone conventional radiography. Subsequent MDCT was performed within 10 d because of persisting clinical symptoms. Using the MDCT data as the reference standard, a fourfold table was used to classify the test results. The effective dose and impaired energy were assessed in order to compare the radiation burden of the two techniques. The Wilcoxon test was performed to compare the two diagnostic modalities.RESULTS: Conventional radiography showed 34 acute fractures of the scaphoid in 124 patients(42.2%). Subsequent MDCT revealed a total of 42 scaphoid fractures. The sensitivity of conventional radiography for scaphoid fracture detection was 42.8% and its specificity was 80% resulting in an overall accuracy of 59.6%. Conventional radiography was significantly inferior to MDCT(P < 0.01) concerning scaphoidfracture detection. The mean effective dose of MDCT was 0.1 m Sv compared to 0.002 m Sv of conventional radiography.CONCLUSION: Conventional radiography is insufficient for accurate scaphoid fracture detection. Regarding the almost negligible effective dose, MDCT should serve as the first imaging modality in wrist trauma.展开更多
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba...BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS.展开更多
Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were adde...Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction.展开更多
基金financially supported by the National Natural Science Foundation of China(No.51304076)the Natural Science Foundation of Hunan Province,China(No.14JJ4064)
文摘Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data.
文摘Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations.
文摘Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances in technology it is now possible to have digital solutions for radiography problems at a very cost effective, environment friendly and also with better image quality in certain applications when compared to CRF. Rather than using a CRF a computed radiography (CR) uses imaging plates to capture the image. The imaging plate contains photosensitive phosphors which contain the latent image. Later this plate is introduced into a reader which is then converted into a digital image. The major advantage and the cost effective element of this system is the ability to reuse the imaging plates unlike the photographic film where in only a single image can be captured and cannot be reused. The computed radiography drastically reduces the cost by eliminating the use of chemicals like film developers and fixers and also the need for a storage room. It also helps to reduce the costs that are involved in the disposal of wastes due to conventional radiography. This paper investigates whether it is cost effective to use computed radiography over film based system at Al-Batnan Medical Center (BMC), Tobruk, Libya by using Cost Benefit Analysis (CBA). Apart from the initial cost of the CR System, based on the data collected from the center, from the year 2008 to 2012 (until June 2012) a total of 581,566 images were produced with the total cost incurred using film based system being USD 4,652,528. If the same number of images were produced using a CR system the total cost incurred would have been USD 82,600. Taking into consideration the cost of a new CR system to be USD 120,000 the overall cost of producing these images is USD 202,600. It is observed that an amount of USD 4,449,928 could have been saved over the period of 5 years starting from 2008 to 2012 by using the CR system at BMC. Using Cost Benefit Analysis, the average value of the net difference between the costs and benefits for the conventional film based system is ?83.38 where as for the Computed System it is 22.06. Based on the principles of Cost Benefit Analysis it can be concluded that the system with a net positive difference is more cost beneficial than the other. With the help of the above two analysis it can be concluded that the use of computed radiography is definitely more cost effective for use at BMC, when compared to the conventional x-ray radiography.
文摘Objective: Maxillofacial injuries are one of the commonest injuries encountered. Roentgenographic evaluation of maxillofacial trauma is of prime importance for diagnosis and treatment of these injuries. Study Design: Forty patients were evaluated in the prospective four-year study. We studied and evaluated the demography and diagnostic efficacy of clinical, plain radiography, and computed scan in maxillofacial trauma. Result: Road traffic accidents were the commonest cause of maxillofacial injuries. Patients having multiple fractures, mandibular fractures were the commonest. Conclusion: Computed tomography proved a useful adjunct in midfacial trauma.
基金Funded by the National Natural Science Foundation of China(No.51072035),the Ph D Program’s Foundation of Ministry of Education of China(No.20090092110029)the Research Innovation Program for College Graduates of Jiangsu Province(No.CXZZ_0145)the Scientific Research Foundation of Graduate School of Southeast University(Nos.YBJJ1127 and YBPY1208)
文摘The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone.
基金This work was supported by the National Key R&D Program of China(2016YFD0300110,2016YFD0300101)the earmarked fund for China Agriculture Research System(CARS-02-25)the Agricultural Science and Technology Innovation Project of Chinese Academy of Agricultural Sciences。
文摘The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mechanical grain harvesting.However,conventional BR evaluation and measurement methods have challenges and limitations.Microstructural crack parameters evaluation of maize kernel is of great importance to BR.In this connection,X-ray computed microtomography(μ-CT)has proven to be a quite useful method for the assessment of microstructure,as it provides important microstructural parameters,such as object volume,surface,surface/volume ratio,number of closed pores,and others.X-ray computed microtomography is a non-destructive technique that enables the reuse of samples already measured and also yields bidimensional(2D)cross-sectional images of the sample as well as volume rendering.In this paper,six different maize hybrid genotypes are used as materials,and the BR of the maize kernels of each variety is tested in the field mechanical grain harvesting,and the BR is used as an index for evaluating the breakage resistance of the variety.The crack characteristic parameters of kernel were detected by X-ray micro-computed tomography,and the relationship between the BR and the kernel crack characteristics was analyzed by stepwise regression analysis.Establishing a relationship between crack characteristic parameters and BR of maize is vital for judging breakage resistance.The results of stepwise multiple linear regression(MLR)showed that the crack characteristics of the object surface,number of closed pores,surface of closed pores,and closed porosity percent were significantly correlated to the BR of field mechanical grain harvesting,with the standard partial regression coefficients of–0.998,–0.988,–0.999,and–0.998,respectively.The R2 of this model was 0.999.Results validation showed that the Stepwise MLR Model could well predict the BR of maize based on these four variables.
基金support from the EPSRC under grants EP/L014289/1 EP/N032888/1 and EP/M014045/1the STFC Global Challenges Network in Batteries and Electrochemical Energy Devices under the grant ST/N002385/1 for facilitation of travelfunding from the Royal Academy of Engineering
文摘Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the National Natural Science Foundation of China(Grant Nos.11205189,11375225,and U1332109)the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42,Y4545320Y2,and 542014IHEPZZBS50659)
文摘A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.
基金Supported by the National Key Research and Development Program of China(Nos.2018YFD0900901,2019YFD0901300)the Scientific Research Fund of the Second Institute of Oceanography,MNR(Nos.JG1906,JG1616,JG1910)+4 种基金the National Natural Science Foundation of China(Nos.41606192/41176140,41706125,41806136)the National Science&Technology Basic Work Program of China(No.2015FY110600)the Key Projects of Philosophy and Social Sciences Research,Ministry of Education,China(No.18JZD059)the Zhejiang Qingshan Lake Innovation Platform for Marine Science and Technology(No.2017E80001)the Project of Long-term Observation and Research Plan in the Changjiang Estuary and Adjacent East China Sea(No.LORCE,14282)。
文摘Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research.
基金Supported by the Municipal Health Bureau of Shanghai(Contract No.04017)
文摘Computed radiography(CR)imaging has high irradiation tolerance and it is easy to archive CR images along with other image information by Digital Imaging and Communications in Medicine(DICOM)format,and to process them.CR can be used in radiation Quality Control(QC)task and verification of treatment setting-up.In this paper,the role of high-energy CR in radiation oncology is studied.The patients were imaged by CR system and EPID before radiotherapy.All verification images were acquired with 1–2 MU(Monitor Unit)using 6 MV X-rays.QC for a linac was done with film and high-energy CR to collect the data on daily,weekly and monthly basis.The QC included Multileaf Collimators(MLC)calibration and mechanical iso-centre check.CR was also adapted to verify patient position,the film was used to compare with digitally reconstructed radiographs(DRR)and portal image from EPID. Treatment setting-up was verified based on the result of comparison.High quality verification images could be acquired by the CR system.Comparing to EPID,the results showed that the system was suitable for practical use to acquire daily verification images,and it was useful to fulfill part of quality assurance(QA)in radiation oncology.The quality of image acquired by the high-energy CR system is comparable or even better than DRRs and portal images. The final treatment set-up for the patients could be verified more accurately with the CR system.
基金Project supported by the National Natural Science Foundation of China (Grant No.10576006)the Foundation of China Academy of Engineering Physics (Grant Nos.2007A01001 and 2009B0202020)
文摘This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems.
文摘In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR imaging, such as effect of ratio of target to film(TF) and source to target(ST) distances and X-ray penetration thickness of the composite material were optimized based on clarity and the actual dimensions of the objects. The optimized parameters were used in the FXR imaging of the ballistic event of 9 mm soft projectile on E-glass/epoxy composite. The real time deformation patterns of both the projectile and composite target during the ballistic impact were captured and studied at different time intervals. The notable failure modes of the 10 mm thick target with time include fibre breakage, bulging on the back side, delamination, recovery of the bulging, reverse bulging and its recovery. However, with increase in thickness of the target to 30 mm the only failure mechanism observed is the breaking of fibres. The ballistic impact event was also numerically simulated using commercially available LS-DYNA software. The numerically simulated deformation patterns of the projectile and target at different time intervals are closely matching with the corresponding radiographic images.
基金This work was partially supported by Quaid-i-Azam University Research Grant, Ministry of Science & Technology Grant, Pakistan Science Foundation Project No. PSF/R&D/C-QU/Phys (199), Higher Education Commission Project for Plasma Physics, Pakistan Atomic
文摘Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.
文摘Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral range and provide a high spatial and temporal resolution.
基金supported by the National Natural Science Foundation of China (52036008)。
文摘This paper studied the thermal physical properties of foundation materials in the molten salt tank of thermal energy storage system after molten salt leakage by Transient plane source experiment and X-ray computed microtomography simulation methods.The microstructure,thermal properties and pressure resistance with different particle diameters were addressed.The measured heat conductivities from Transient plane source experiment for three cases are 0.49 W/(m·K),0.48 W/(m·K),and 0.51 W/(m·K),and the porosity is 30.1%,30.7%,and 31.2% respectively.The heat conductivity simulating results of three cases are 0.471 W/(m·K),0.482W/(m·K),and 0.513 W/(m·K).The ratio of difference between the results of simulation and Transient plane source measurement is as low as 1.2%,verifying the reliability of experimental and simulation results to a certain degree.Compared with the heat conductivity of 0.097-0.129 W/(m·K) and porosity of 71.6%-78.9% without leaking salt,the porosity is reduced by more than 50% while the heat conductivity increased by 4 to 5 times after molten salt leakage.This significant increase in heat conductivity has a great impact on security operation,structure design,and modeling of the tank foundation for solar power plants.
文摘AIM: To determine the diagnostic accuracy and radiation dose of conventional radiography and multidetector computed tomography(MDCT) in suspected scaphoid fractures.METHODS: One hundred twenty-four consecutive patients were enrolled in our study who had suffered from a wrist trauma and showed typical clinical symptoms suspicious of an acute scaphoid fracture. All patients had initially undergone conventional radiography. Subsequent MDCT was performed within 10 d because of persisting clinical symptoms. Using the MDCT data as the reference standard, a fourfold table was used to classify the test results. The effective dose and impaired energy were assessed in order to compare the radiation burden of the two techniques. The Wilcoxon test was performed to compare the two diagnostic modalities.RESULTS: Conventional radiography showed 34 acute fractures of the scaphoid in 124 patients(42.2%). Subsequent MDCT revealed a total of 42 scaphoid fractures. The sensitivity of conventional radiography for scaphoid fracture detection was 42.8% and its specificity was 80% resulting in an overall accuracy of 59.6%. Conventional radiography was significantly inferior to MDCT(P < 0.01) concerning scaphoidfracture detection. The mean effective dose of MDCT was 0.1 m Sv compared to 0.002 m Sv of conventional radiography.CONCLUSION: Conventional radiography is insufficient for accurate scaphoid fracture detection. Regarding the almost negligible effective dose, MDCT should serve as the first imaging modality in wrist trauma.
文摘BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS.
基金supported by the Fundamental Research Funds for the Central Universities of Ministry of Education of China(Nos.lzujbky-2016-208 and lzujbky-2016-32)the Lanzhou University Construction Project for Innovation and Cooperative Education Base
文摘Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction.