期刊文献+
共找到101,998篇文章
< 1 2 250 >
每页显示 20 50 100
Stereotactic body radiotherapy in pancreatic adenocarcinoma 被引量:1
1
作者 Carolina de la Pinta 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第1期14-19,共6页
Background:Stereotactic body radiotherapy(SBRT)in pancreatic cancer allows high delivery of radiation doses on tumors without affecting surrounding tissue.This review aimed at the SBRT application in the treatment of ... Background:Stereotactic body radiotherapy(SBRT)in pancreatic cancer allows high delivery of radiation doses on tumors without affecting surrounding tissue.This review aimed at the SBRT application in the treatment of pancreatic cancer.Data sources:We retrieved articles published in MEDLINE/PubMed from January 2017 to December 2022.Keywords used in the search included:“pancreatic adenocarcinoma”OR“pancreatic cancer”AND“stereotactic ablative radiotherapy(SABR)”OR“stereotactic body radiotherapy(SBRT)”OR“chemoradiotherapy(CRT)”.English language articles with information on technical characteristics,doses and fractionation,indications,recurrence patterns,local control and toxicities of SBRT in pancreatic tumors were included.All articles were assessed for validity and relevant content.Results:Optimal doses and fractionation have not yet been defined.However,SBRT could be the standard treatment in patients with pancreatic adenocarcinoma in addition to CRT.Furthermore,the combination of SBRT with chemotherapy may have additive or synergic effect on pancreatic adenocarcinoma.Conclusions:SBRT is an effective modality for patients with pancreatic cancer,supported by clinical practice guidelines as it has demonstrated good tolerance and good disease control.SBRT opens a possibility of improving outcomes for these patients,both in neoadjuvant treatment and with radical intent. 展开更多
关键词 CHEMOradiotherapy Pancreatic adenocarcinoma radiotherapy Stereotactic body radiotherapy Stereotactic ablative radiotherapy
下载PDF
Correlation between dose-volume parameters and rectal bleeding after 12 fractions of carbon ion radiotherapy for prostate cancer
2
作者 Takashi Ono Hiraku Sato +5 位作者 Yuya Miyasaka Yasuhito Hagiwara Natsuko Yano Hiroko Akamatsu Mayumi Harada Mayumi Ichikawa 《World Journal of Radiology》 2024年第7期256-264,共9页
BACKGROUND Carbon ion radiotherapy(CIRT)is currently used to treat prostate cancer.Rectal bleeding is a major cause of toxicity even with CIRT.However,to date,a correlation between the dose and volume parameters of th... BACKGROUND Carbon ion radiotherapy(CIRT)is currently used to treat prostate cancer.Rectal bleeding is a major cause of toxicity even with CIRT.However,to date,a correlation between the dose and volume parameters of the 12 fractions of CIRT for prostate cancer and rectal bleeding has not been shown.Similarly,the clinical risk factors for rectal bleeding were absent after 12 fractions of CIRT.AIM To identify the risk factors for rectal bleeding in 12 fractions of CIRT for prostate cancer.METHODS Among 259 patients who received 51.6 Gy[relative biological effectiveness(RBE)],in 12 fractions of CIRT,15 had grade 1(5.8%)and nine had grade 2 rectal bleeding(3.5%).The dose-volume parameters included the volume(cc)of the rectum irradiated with at least x Gy(RBE)(Vx)and the minimum dose in the most irradiated x cc normal rectal volume(Dx).RESULTS The mean values of D6cc,D2cc,V10 Gy(RBE),V20 Gy(RBE),V30 Gy(RBE),and V40 Gy(RBE)were significantly higher in the patients with rectal bleeding than in those without.The cutoff values were D6cc=34.34 Gy(RBE),D2cc=46.46 Gy(RBE),V10 Gy(RBE)=9.85 cc,V20 Gy(RBE)=7.00 cc,V30 Gy(RBE)=6.91 cc,and V40 Gy(RBE)=4.26 cc.The D2cc,V10 Gy(RBE),and V20 Gy(RBE)cutoff values were significant predictors of grade 2 rectal bleeding.CONCLUSION The above dose-volume parameters may serve as guidelines for preventing rectal bleeding after 12 fractions of CIRT for prostate cancer. 展开更多
关键词 Carbon ion radiotherapy Prostate cancer Rectal bleeding Dose volume parameters PREVENTION
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
3
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy Intensity modulated radiation therapy TOXICITY Helical tomotherapy volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Three-Dimensional Conformal and Intensity Modulated Dynamic Radiotherapy in Juvenile Nasopharyngeal Angiofibroma
4
作者 María Fátima Chilaca Rosas David Rafael Salazar Calderon +6 位作者 Manuel Tadeo Contreras Aguilar Carlos Eduardo Barrios Merino Melissa García Lezama Benjamín Conde Castro Shelley Astrid Martínez Torres Katia Hernández Salgado Rafael Medrano Guzmán 《International Journal of Otolaryngology and Head & Neck Surgery》 2023年第4期269-278,共10页
Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable pa... Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable patients, radiotherapy is a therapeutic option for local control. Our aim in this study was to analyze the clinical benefit and local control provided by two modalities of radiotherapy: the Three-Dimensional Conformal (3DC) technique and volumetric modulated arc therapy (VMAT), applied to pediatric patients with JNA considered unresectable and non-recurrent. Methods: In retrospective study, the information was recorded from pediatric patients with a diagnosis of non-recurrent and unresectable JNA treated with radiotherapy at the Oncology Hospital of the National Medical Center SXXI of Mexico City, from March 2010 to March 2021. Radiotherapy management and its association with clinical outcomes of tumour control, and symptoms were assessed. In addition, an evaluation of acute and chronic toxicity was performed. Results: It was found that the median age was 14 years. 9 patients (37.5%) underwent 3DC and 15 (62.5%) VMAT. In terms of local control, and progression-free survival, we did not find significant difference between radiotherapy modalities (p ≤ 0.57). Acute toxicity for both modalities presented statistical differences for radio epithelitis (p = 0.03). Only Grade I and II radiation-induced acute toxicity was observed. Regarding chronic toxicity, statistical significance was observed for craniofacial hypoplasia, in relation to its absence in the VMAT group (p = 0.001). Conclusion: The VMAT presents improvements in dosimetry parameters that improve patient toxicity. In both techniques adequate tumour control was observed, however, the rarity of the disease is a limitation to establish the most appropriate therapeutic technique. 展开更多
关键词 Intensity-modulated radiotherapy Nasopharyngeal Angiofibroma PEDIATRIC radiotherapy TOXICITY
下载PDF
Hemostatic radiotherapy for bleeding gastrointestinal
5
作者 Vrushab Rao Soumya Singh Bhooshan Zade 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第5期2261-2263,共3页
Hemostatic radiotherapy is a non-invasive treatment for bleeding gastrointestinal(GI)tumors,promoting tumor shrinkage,blood supply reduction,and fibrotic tissue formation.It is effective in cases where traditional int... Hemostatic radiotherapy is a non-invasive treatment for bleeding gastrointestinal(GI)tumors,promoting tumor shrinkage,blood supply reduction,and fibrotic tissue formation.It is effective in cases where traditional interventions are insufficient or contraindicated and can prevent recurrent bleeding in patients with GI bleeding histories.Hypofractionation schedules are also effective for tumor control and patient compliance. 展开更多
关键词 Gastrointestinal tumors Hemostatic radiotherapy Palliative radiotherapy Acute bleeding HYPOFRACTIONATION
下载PDF
Postoperative chemoradiotherapy with capecitabine and oxaliplatin vs.capecitabine for pathological stage N2 rectal cancer
6
作者 Ning Li Yuan Zhu +20 位作者 Luying Liu Yanru Feng Wenling Wang Jun Wang Hao Wang Gaofeng Li Yuan Tang Chen Hu Wenyang Liu Hua Ren Shulian Wang Weihu Wang Yongwen Song Yueping Liu Hui Fang Yu Tang Ningning Lu Bo Chen Shunan Qi Yexiong Li Jing Jin 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2024年第5期577-586,共10页
Objective:Several studies have been conducted on the effects and toxicity of adding oxaliplatin to fluorouracilbased or capecitabine-based chemoradiotherapy(CRT)regimens as significantly increasing the toxic response ... Objective:Several studies have been conducted on the effects and toxicity of adding oxaliplatin to fluorouracilbased or capecitabine-based chemoradiotherapy(CRT)regimens as significantly increasing the toxic response without benefit to survival.In this study,we further explored the role of these two postoperative CRT regimens in patients with pathological stage N2 rectal cancer.Methods:This study was a subgroup analysis of a randomized clinical trial.A total of 180 patients with pathological stage N2 rectal cancer were eligible,85 received capecitabine with radiotherapy(RT),and 95 received capecitabine and oxaliplatin with RT.Patients in both groups received adjuvant chemotherapy[capecitabine and oxaliplatin(XELOX);or fluorouracil,leucovorin,and oxaliplatin(FOLFOX)]after CRT.Results:At a median follow-up of 59.2[interquartile range(IQR),34.0−96.8]months,the three-year diseasefree survival(DFS)was 53.3%and 64.9%in the control group and the experimental group,respectively[hazard ratio(HR),0.63;95%confidence interval(95%CI),0.41−0.98;P=0.04].There was no significant difference between the groups in overall survival(OS)(HR,0.62;95%CI,0.37−1.05;P=0.07),the incidence of locoregional recurrence(HR,0.62;95%CI,0.24−1.64;P=0.33),the incidence of distant metastasis(HR,0.67;95%CI,0.42−1.06;P=0.09)and grade 3−4 acute toxicities(P=0.78).For patients with survival longer than 3 years,the conditional overall survival(COS)was significantly better in the experimental group(HR,0.39;95%CI,0.16−0.96;P=0.03).Conclusions:Our results indicated that adding oxaliplatin to capecitabine-based postoperative CRT is safe and effective in patients with pathological stage N2 rectal cancer. 展开更多
关键词 CHEMOradiotherapy OXALIPLATIN CAPECITABINE rectal neoplasms drug therapy radiotherapy treatment outcome
下载PDF
Dosimetric consequences of tumor volume changes after kilovoltage cone-beam computed tomography for non-operative lung cancer during adaptive intensity-modulated radiotherapy or fractionated stereotactic radiotherapy
7
作者 Jian Hu Ximing Xu +4 位作者 Guangjin Yuan Wei Ge Liming Xu Aihua Zhang Junjian Deng 《Oncology and Translational Medicine》 CAS 2015年第5期195-200,共6页
Objective The aim of this study was to investigate tumor volume changes with kilovoltage cone-beam computed tomography (kV-CBCT) and their dosimetric consequences for non-operative lung cancer during intensity-modul... Objective The aim of this study was to investigate tumor volume changes with kilovoltage cone-beam computed tomography (kV-CBCT) and their dosimetric consequences for non-operative lung cancer during intensity-modulated radiotherapy (IMRT) or fractionated stereotactic radiotherapy. Methods Eighteen patients with non-operative lung cancer who received IMRT consisting of 1.8-2.2 Gy/fraction and five fractions per week or stereotactic radiotherapy with 5-8 Gy/fraction and three fractions a week were studied, kV-CBCT was performed once per week during IMRT and at every fraction during stereotactic radiotherapy. The gross tumor volume (GTV) was contoured on the kV-CBCT images, and adaptive treatment plans were created using merged kV-CBCT and primary planning computed tomogra- phy image sets. Tumor volume changes and dosimetric parameters, including the minimum dose to 95% (D95) or 1% (D1) of the planning target volume (PTV), mean lung dose (MLD), and volume of lung tissue that received more than 5 (Vs), 10 (Vl0), 20 (V20), and 30 (V30) Gy were retrospectively analyzed. Results The average maximum change in GTV observed during IMRT or fractionated stereotactic radio- therapy was -25.85% (range, -13.09% --56.76%). The D95 and Dr of PTV for the adaptive treatment plans in all patients were not significantly different from those for the initial or former adaptive treatment plans. In patients with tumor volume changes of 〉20% in the third or fourth week of treatment during IMRT, adap- tive treatment plans offered clinically meaningful decreases in MLD and V5, V10, V20, and V30; however, in patients with tumor volume changes of 〈 20% in the third or fourth week of treatment as well as in patients with stereotactic radiotherapy, there were no significant or clinically meaningful decreases in the dosimetric parameters. Conclusion Adaptive treatment planning for decreasing tumor volume during IMRT may be beneficial for patients who experience tumor volume changes of 〉20% in the third or fourth week of treatment. 展开更多
关键词 lung cancer kilovoltage cone-beam computed tomography (kV-CBCT) intensity-modulated radiotherapy (IMRT) stereotactic radiotherapy tumor changes adaptive planning
下载PDF
Simultaneous integrated dose reduction intensity-modulated radiotherapy effectively reduces cardiac toxicity in limited-stage small cell lung cancer 被引量:1
8
作者 Jing Luo Jiawei Song +6 位作者 Li Xiao Jiajia Zhang Yipeng Cao Jun Wang Ping Wang Lujun Zhao Ningbo Liu 《Cancer Biology & Medicine》 SCIE CAS CSCD 2023年第6期452-464,共13页
Objective:To assess the clinical outcomes and toxicities of once daily(QD)simultaneous dose reduction intensity-modulated radiotherapy(SDR-IMRT-QD;SDR-QD)versus conventional QD IMRT(C-QD)and twice daily(BID)IMRT in pa... Objective:To assess the clinical outcomes and toxicities of once daily(QD)simultaneous dose reduction intensity-modulated radiotherapy(SDR-IMRT-QD;SDR-QD)versus conventional QD IMRT(C-QD)and twice daily(BID)IMRT in patients with limited-stage small cell lung cancer(LS-SCLC).Methods:After propensity score matching(PSM),a retrospective analysis involving 300 patients with LS-SCLC treated using SDR-QD,C-QD,or BID was performed from January 1,2014 to December 31,2019.The prescribed irradiation dose in the SDR-QD cohort was 60 Gy/PGTV and 54 Gy/PTV QD.The radiation dose was 60 Gy for both PGTV and PTV QD in the C-QD cohort.The radiation dose was 45 Gy for both PGTV and PTV in the BID cohort.Toxicities,short-term effects,and survival outcomes were recorded.A meta-analysis on the protective effects of pharmaceuticals for cardiac toxicities induced by anti-tumor therapy was performed.Results:The median overall survival time(MST)in the 3 cohorts were 32.7 months(SDR-QD),26.3 months(C-QD),and 33.6 months(BID);the differences between groups were statistically significant.Lower toxicities and doses to organs-at-risk(OARs)occurred in the SDR-QD and BID cohorts.Further,the cardiac dose dosimetric parameter Vheart40 was negatively associated with survival(r=-0.35,P=0.007).A Vheart40 value of 16.5%was recommended as a cut-off point,which yielded 54.7%sensitivity and 85.7%specificity for predicting negative survival outcomes.The meta-analysis indicated that pharmaceuticals significantly reduced the cardiac toxicities induced by chemotherapy,but not radiotherapy.Conclusions:SDR-QD was shown to have similar toxicities and survival compared with BID,but fewer toxicities and better survival than C-QD.In addition,cardiac dose exposure was negatively associated with survival.Thus,16.5%of the cardiac dosimetric parameter Vheart40 is recommended as the cut-off point,and a Vheart40>16.5%predicts poor survival. 展开更多
关键词 CARDIAC radiotherapy doses
下载PDF
Prognostic value and predictive threshold of tumor volume for patients with locally advanced nasopharyngeal carcinoma receiving intensity-modulated radiotherapy 被引量:12
9
作者 Yu-Xiang He Ying Wang +9 位作者 Peng-Fei Cao Lin Shen Ya-Jie Zhao Zi-Jian Zhang Deng-Ming Chen Tu-Bao Yang Xin-Qiong Huang Zhou Qin You-Yi Dai Liang-Fang Shen 《Chinese Journal of Cancer》 SCIE CAS CSCD 2016年第12期725-734,共10页
Background: Gross target volume of primary tumor(GTV?P) is very important for the prognosis prediction of patients with nasopharyngeal carcinoma(NPC), but it is unknown whether the same is true for locally advanced NP... Background: Gross target volume of primary tumor(GTV?P) is very important for the prognosis prediction of patients with nasopharyngeal carcinoma(NPC), but it is unknown whether the same is true for locally advanced NPC patients treated with intensity?modulated radiotherapy(IMRT). This study aimed to clarify the prognostic value of tumor volume for patient with locally advanced NPC receiving IMRT and to ind a suitable cut?of value of GTV?P for prognosis prediction.Methods: Clinical data of 358 patients with locally advanced NPC who received IMRT were reviewed. Receiver oper?ating characteristic(ROC) curves were used to identify the cut?of values of GTV?P for the prediction of diferent end?points [overall survival(OS), local relapse?free survival(LRFS), distant metastasis?free survival(DMFS), and disease?free survival(DFS)] and to test the prognostic value of GTV?P when compared with that of the American Joint Committee on Cancer T staging system.Results: The 358 patients with locally advanced NPC were divided into two groups by the cut?of value of GTV?P as determined using ROC curves: 219(61.2%) patients with GTV?P ≤46.4 mL and 139(38.8%) with GTV?P >46.4 mL. The 3?year OS, LRFS, DMFS, and DFS rates were all higher in patients with GTV?P ≤46.4 mL than in those with GTV?P > 46.4 mL(all P < 0.05). Multivariate analysis indicated that GTV?P >46.4 mL was an independent unfavorable prognostic factor for patient survival. The ROC curve veriied that the predictive ability of GTV?P was superior to that of T category(P < 0.001). The cut?of values of GTV?P for the prediction of OS, LRFS, DMFS, and DFS were 46.4, 57.9, 75.4 and 46.4 mL, respectively.Conclusion: In patients with locally advanced NPC, GTV?P >46.4 mL is an independent unfavorable prognostic indi?cator for survival after IMRT, with a prognostic value superior to that of T category. 展开更多
关键词 Nasopharyngeal carcinoma Intensity-modulated radiotherapy Gross target volume of primary tumor PROGNOSIS
下载PDF
Partial and Full Arc Volumetric Modulated Arc Therapy in Lung Cancer Stereotactic Body Radiotherapy with Different Definitions of Internal Target Volume Based on 4D CT 被引量:2
10
作者 Wu Wang Didi Chen +5 位作者 Ce Han Xiaomin Zheng Yongqiang Zhou Changfei Gong Congying Xie Xiance Jin 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期491-502,共12页
Purpose: To investigate the feasibility of partial arc volumetric modulated arc therapy (VMAT) in lung cancer stereotactic body radiotherapy (SBRT), as well the volumetric and dosimetric effects of different internal ... Purpose: To investigate the feasibility of partial arc volumetric modulated arc therapy (VMAT) in lung cancer stereotactic body radiotherapy (SBRT), as well the volumetric and dosimetric effects of different internal target volume (ITV) definitions with 4D CT. Methods: Fourteen patients with primary and metastatic lung cancer underwent SBRT were enrolled. Full and partial arc VMAT plans were generated with four different ITVs: ITVall, ITVMIP, ITVAIP and ITV2phases, representing ITVs generated from all 10 respiratory phases, maximum intensity projection (MIP), average intensity projection (AIP), and 2 extreme respiratory phases. Volumetric and dosimetric differences, as well as MU and delivery time were investigated. Results: Partial arc VMAT irradiated more dose at 2 cm away from planning target volume (PTV) (P = 0.002), however, it achieved better protection on mean lung dose , lung V5, spinal cord, heart and esophagus compared with full arc VMAT. The average MU and delivery time of partial arc VMAT were 240 and 1.6 min less than those of full arc VMAT. There were no significant differences on target coverage and organ at risks (OARs) sparing among four ITVs. The average percent volume differences of ITVMIP, ITVAIP and ITV2phases to ITVall were 8.6%, 13.4%, and 25.2%, respectively. Conclusions: Although partial arc VMAT delivered more dose 2 cm out of PTV, it decreases the dose to lung, spinal cord, and esophagus, as well decreased the total MU and delivery time compared with full arc VMAT without sacrificing target coverage. Partial arc VMAT was feasible and more efficient for lung SBRT. 展开更多
关键词 Lung Cancer STEREOTACTIC Body radiotherapy Four Dimensional COMPUTED Tomography Internal Target volume volumeTRIC modulated ARC Therapy
下载PDF
Present situation and prospect of immunotherapy for unresectable locally advanced esophageal cancer during peri-radiotherapy 被引量:1
11
作者 Feng-Mei Wang Peng Mo +2 位作者 Xue Yan Xin-Yue Lin Zhi-Chao Fu 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第1期1-7,共7页
Four major studies(Checkmate577,Keynote-590,Checkmate649 and Attraction-4)of locally advanced esophageal cancer published in 2020 have established the importance of immunotherapy,represented by anti-programmed death p... Four major studies(Checkmate577,Keynote-590,Checkmate649 and Attraction-4)of locally advanced esophageal cancer published in 2020 have established the importance of immunotherapy,represented by anti-programmed death protein(PD)-1 in postoperative adjuvant treatment and advanced first-line treatment of locally advanced or advanced esophageal cancer and esophagogastric junction cancer,from the aspects of proof of concept,long-term survival,overall survival rate and progression-free survival.For unresectable or inoperable nonmetastatic esophageal cancer,concurrent radiotherapy and chemotherapy is the standard treatment recommended by various guidelines.Because its curative effect is still not ideal,it is necessary to explore radical radiotherapy and chemotherapy in the future,and it is considered to be promising to combine them with immunotherapeutic drugs such as anti-PD-1.This paper mainly discusses how to combine radical concurrent radiotherapy and chemotherapy with immunotherapy for unresectable local advanced esophageal cancer. 展开更多
关键词 Esophageal carcinoma Locally advanced radiotherapy IMMUNOTHERAPY
下载PDF
Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT), 5F Intensity Modulated Radiotherapy (IMRT) and 3D Conformal Radiotherapy (3DCRT) in Rectal Carcinoma Receiving Neoadjuvant Chemoradiotherapy 被引量:1
12
作者 Ge Wen Jinshan Zhang +6 位作者 Feng Chi Li Chen Sijuan Huang Shaoqing Niu Yuanhong Gao Bixiu Wen Yujing Zhang 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第1期54-63,共10页
Objective: To investigate better dosimetric distribution of volumetric modulated arc therapy (VMAT) vs. 5F intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3DCRT) in patients with locally advance... Objective: To investigate better dosimetric distribution of volumetric modulated arc therapy (VMAT) vs. 5F intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3DCRT) in patients with locally advanced rectal cancer (LARC) when treated with neoadjuvant chemoradiotherapy. Methods: 3D-CRT, 5F-IMRT and VMAT plans for preoperative radiotherapy were 66011designed in 12 patients with locally advanced rectal cancer. The conformity index (CI) and homogeneity index (HI) in target volume, and the dose and volume of the organs at risk (OAR) irradiated including small bowel, bladder and bilatera1 femoral heads were compared among the three plans. Results: The CI for planning target volume (PTV) 2 and HI for PTV1 of VMRT and 5F-IMRT were superior to 3D-CRT. The CI of VMAT, 5F-IMRT and 3D-CRT plans were 0.71, 0.69 and 0.62 (p = 0.011 and p = 0.019, respectively). The HI of the VMAT and 5F-IMRT plans were both 1.04 and 3D-CRT planning was 1.06 (p = 0.022 and p = 0.006, respectively). The V35 - V45 of small bowel in VMAT were significantly less than in 5F-IMRT and 3D-CRT. V35 was 47.0, 56.4, and 72.8 cm3 for VMAT, 5F-IMRT, and 3D-CRT (p = 0.021 and p = 0.034, respectively), while V40 was 30.5, 35.5, 45.1 cm3 (p = 0.024 and p = 0.032, respectively) and V45 was 15.1, 18.1, 30.0 cm3 (p = 0.033 and p = 0.032, respectively). The D5, V30 and V50 of bladder in 3D-CRT were less than in VMAT and 5F-IMRT planning (p = 0.034, 0.004, 0.002 and p = 0.027, 0.003, 0.002, respectively). The Dmean of left femoral head in VMAT and 5F-IMRT were less than in 3D-CRT planning (p = 0.028 and p = 0.022, respectively) and the Dmean, V30 of right femoral head in VMAT and 5F-IMRT were better than in 3D-CRT planning (p = 0.044, 0.036 and p = 0.023, 0.028, respectively). Conclusions: Dosimetric analyses demonstrated that IMRT is superior to 3D-CRT in the conformity and homogeneity of dose distribution to the target volume, and provide a better protection to OARs sparing in patients with locally advanced rectal cancer for preoperative radiotherapy. With similar target coverage, VMRT is superior to 5F-IMRT in normal tissue sparing. 展开更多
关键词 RECTAL Cancer PREOPERATIVE radiotherapy Dosimetry Conformity INDEX HOMOGENEITY INDEX
下载PDF
Radiotherapy for hyoid bone metastasis from lung adenocarcinoma:A case report 被引量:1
13
作者 Jonathan Hsu Kambridge Hribar Joseph Poen 《World Journal of Clinical Oncology》 2024年第1期159-164,共6页
BACKGROUND Metastasis to the hyoid bone is an exceptionally rare occurrence,with documented cases limited to breast,liver,colon,skin,lung,and prostate cancers.This report highlights an unusual case involving the metas... BACKGROUND Metastasis to the hyoid bone is an exceptionally rare occurrence,with documented cases limited to breast,liver,colon,skin,lung,and prostate cancers.This report highlights an unusual case involving the metastasis of lung adenocarcinoma to the hyoid bone,accompanied by a distinctive headache.Previous documentation involved surgical resection of the hyoid mass.We present a case displaying the benefits of palliative radiotherapy.CASE SUMMARY A 72-year-old non-smoking,non-alcoholic woman,initially under investigation for a year-long elevation in absolute lymphocyte count,presented with a monthlong history of intermittent throat pain.Despite negative findings in gastroenterological and otolaryngologic examinations,a contrast-enhanced chest computed tomography scan revealed a mediastinal mass and questionable soft tissue thickening in her left anterolateral neck.Subsequent imaging and biopsies confirmed the presence of lung adenocarcinoma metastasis to the hyoid bone.The patient was treated with platinum-based chemo-immunotherapy along with pembrolizumab.Ultimately,the lung cancer was unresponsive.Our patient opted for palliative radiation therapy instead of surgical resection to address her throat pain.As a result,her throat pain was alleviated,and it also incidentally resolved her chronic headaches.This is the second documented case of lung adenocarcinoma metastasizing to the hyoid bone.CONCLUSION Palliative radiotherapy may add to the quality of life in symptomatic patients with cancer metastatic to the hyoid bone. 展开更多
关键词 METASTASIS radiotherapy Adenocarcinoma HYOID THROAT HEADACHE Case report
下载PDF
Volumetric modulated arc radiotherapy for limited osteosclerotic myeloma
14
作者 Aurélie Robles Antonin Levy +9 位作者 Coralie Moncharmont Lamine Farid Jean-Baptiste Guy Nadia Malkoun Lysian Cartier Cyrus Chargari Isabelle Guichard Jean-Noёl Talabard Guy de Laroche Nicolas Magné 《World Journal of Radiology》 CAS 2013年第4期173-177,共5页
AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:... AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:A 70-year-old male with histologically confirmed osteosclerotic myeloma was treated in our department in July 2010 with VMAT. Fourty-six Gray in 23 fractions were given on three bone lesions. Doses delivered to target volume and critical organs were compared with a tridimensional conformal radiotherapy (3D-RT) plan. Treatment was well tolerated without any side effects.RESULTS:VMAT improved dose homogeneity within the target volume, as compared to 3D-RT (standard deviations:2.9 Gy and 1.6 Gy for 3D and VMAT, respectively). VMAT resulted in a better sparing of critical organs. Dose delivered to 20% of organ volume (D20) was reduced from 22 Gy (3D-RT) to 15 Gy (VMAT) for small bowel, from 24 Gy (3D-RT) to 17 Gy (VMAT) for bladder and from 47 Gy (3D-RT) to 3 Gy (VMAT) for spinal cord. Volumes of critical organs that received at least 20 Gy (V20) were decreased by the use of VMAT, as compared to 3D-RT (V20 bladder:10% vs 99%; V20 small bowel:6% vs 21%). One year after treatment completion, no tumor progression has been reported. CONCLUSION:VMAT improved dose distribution as compared to 3D-RT for limited osteosclerotic myeloma, with better saving of critical organs. 展开更多
关键词 volumeTRIC intensity-modulated ARC radiotherapy Conformal radiotherapy Critical organs Osteosclerotic MYELOMA Polyneuropathy organomegaly ENDOCRINOPATHY monoclonal GAMMOPATHY and skin change syndrome
下载PDF
Signal intensity changes of dentate nucleus on plain MR T1WI innasopharyngeal carcinoma patients after radiotherapy andmultiple injections of gadolinium-base contrast agent
15
作者 SUN Jiping ZHOU Jian +2 位作者 TAO Zhigang LIANG Jiafeng DING Zhongxiang 《中国医学影像技术》 CSCD 北大核心 2024年第8期1170-1173,共4页
Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(... Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(GBCA).Methods Fifty patients with pathologically confirmed nasopharyngeal carcinoma and received intensity-modulated radiotherapy were retrospectively enrolled as the nasopharyngeal carcinoma group,and 50 patients with other malignant tumors and without history of brain radiotherapy were retrospectively enrolled as the control group.All patients received yearly GBCA enhanced MR examinations for the nasopharynx or the head.T1WI signal intensities of the dentate nucleus and the pons on same plane were measured based on images in the year of confirmed diagnosis(recorded as the first year)and in the second to the fifth years.T1WI signal intensity ratio of year i(ranging from 1 to 5)was calculated with values of dentate nucleus divided by values of the pons(ΔSI i),while the percentage of relative changes of year j(ranging from 2 to 5)was calculated withΔSI j compared toΔSI 1(Rchange j).The values of these two parameters were compared,and the correlation ofΔSI and GBCA injection year-time was evaluated within each group.Results No significant difference of gender,age norΔSI 1 was found between groups(all P>0.05).The second to the fifth yearΔSI and Rchange in nasopharyngeal carcinoma group were all higher than those in control group(all P<0.05).Within both groups,ΔSI was positively correlated with GBCA injection year-time(both P<0.05).Conclusion Patients with nasopharyngeal carcinoma who underwent radiotherapy and multiple times of intravenous injection of GBCA tended to be found with gradually worsening GBCA deposition in dentate nucleus,for which radiotherapy might be a risk factor. 展开更多
关键词 nasopharyngeal neoplasms radiotherapy contrast media cerebellar nuclei
下载PDF
Targeting the organelle for radiosensitization in cancer radiotherapy
16
作者 Xiaoyan Sun Linjie Wu +2 位作者 Lina Du Wenhong Xu Min Han 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2024年第2期52-71,共20页
Radiotherapy is a well-established cytotoxic therapy for local solid cancers, utilizing high-energy ionizing radiation to destroy cancer cells. However, this method has several limitations, including low radiation ene... Radiotherapy is a well-established cytotoxic therapy for local solid cancers, utilizing high-energy ionizing radiation to destroy cancer cells. However, this method has several limitations, including low radiation energy deposition, severe damage to surrounding normal cells, and high tumor resistance to radiation. Among various radiotherapy methods, boron neutron capture therapy (BNCT) has emerged as a principal approach to improve the therapeutic ratio of malignancies and reduce lethality to surrounding normal tissue, but it remains deficient in terms of insufficient boron accumulation as well as short retention time, which limits the curative effect. Recently, a series of radiosensitizers that can selectively accumulate in specific organelles of cancer cells have been developed to precisely target radiotherapy, thereby reducing side effects of normal tissue damage, overcoming radioresistance, and improving radiosensitivity. In this review, we mainly focus on the field of nanomedicine-based cancer radiotherapy and discuss the organelle-targeted radiosensitizers, specifically including nucleus, mitochondria, endoplasmic reticulum and lysosomes. Furthermore, the organelle-targeted boron carriers used in BNCT are particularly presented. Through demonstrating recent developments in organelle-targeted radiosensitization, we hope to provide insight into the design of organelle-targeted radiosensitizers for clinical cancer treatment. 展开更多
关键词 Cancer radiotherapy Organelle-target RADIOSENSITIZATION Boron neutron capture therapy NANOMEDICINES
下载PDF
Prognosis of radiotherapy for esophageal cancer in elderly patients exceeding seventy-five years old
17
作者 Li-Li Hu Feng Rong +5 位作者 Lei Liu Ling Zhang Lei-Lei Zhang Qun Yang Zhao-Long Xia Hui Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第12期4636-4649,共14页
BACKGROUND Esophageal cancer(EC)often occurs in the elderly,with approximately 33%of patients aged≥75 years at the time of diagnosis.AIM To evaluate the prognostic factors for radiotherapy(RT)in elderly patients with... BACKGROUND Esophageal cancer(EC)often occurs in the elderly,with approximately 33%of patients aged≥75 years at the time of diagnosis.AIM To evaluate the prognostic factors for radiotherapy(RT)in elderly patients with unresectable EC.METHODS We retrospectively analyzed the clinical characteristics,toxic reactions,and survival information of EC patients aged≥75 years who underwent intensity-modulated RT at Lu’an Hospital of Anhui Medical University between January 2016 and September 2023.Kaplan-Meier analysis was used to draw the overall survival(OS)curves,and Cox regression analysis was employed to evaluate the influence of various clinical factors on the prognosis.RESULTS A total of 139 patients were enrolled.The median follow-up time was 52.0 months.The median OS was 20.0 months.The 1-year,2-year,3-year,and 5-year OS rates were 69.8%,38.7%,28.2%,and 17.5%,respectively.Univariate analysis showed that age,radiation dose,and chemotherapy had no significant impact on prognosis.Multivariate analysis indicated that clinical stage[Ⅲ-Ⅳa vsⅠ-Ⅱ,hazard ratio(HR)=2.421,95%confidence interval(CI):1.242-4.718,P=0.009;IVb vsⅠ-Ⅱ,HR=4.222,95%CI:1.888-9.438,P<0.001),Charlson comorbidity index(CCI)(0 vs≥1,HR=1.539,95%CI:1.015-2.332,P=0.042),and nutritional risk screening 2002(NRS2002)(<3 vs≥3,HR=2.491,95%CI:1.601-3.875,P<0.001)were independent prognostic factors for OS.CONCLUSION Our results suggest that CCI and NRS2002 were independent prognostic factors of OS for unresectable elderly EC patients undergoing RT.For elderly patients with EC,full attention should be given to biological age-related indicators,such as comorbidities and nutrition,when formulating treatment protocols.These factors should be considered in future clinical practice. 展开更多
关键词 Elderly patient Esophageal cancer radiotherapy PROGNOSIS COMORBIDITY Nutritional risk
下载PDF
Potential of non-Western medicines in chemoradiotherapy for cervical cancer
18
作者 Takashi Ono Masashi Koto 《World Journal of Clinical Cases》 SCIE 2025年第2期21-23,共3页
This editorial explores the potential integration of non-Western medicine into radiotherapy for cervical cancer.While radiotherapy remains a radical treatment for cervical cancer,its associated toxicity and decline in... This editorial explores the potential integration of non-Western medicine into radiotherapy for cervical cancer.While radiotherapy remains a radical treatment for cervical cancer,its associated toxicity and decline in quality of life can significantly impact patients’lives.Currently,most treatments are supportive,with no specific treatment options available in Western medicine.Non-Western medicine,often less toxic and easier to administer,has shown promising results when used alongside radiotherapy for cervical cancer.Despite these potential benefits,challenges such as limited evidence and restricted application areas persist.While non-Western medicines may offer potential improvements in chemoradiotherapy outcomes for cervical cancer,further research is necessary to substantiate these benefits. 展开更多
关键词 Cervical cancer radiotherapy Non-Western medicine KAMPO Herbal medicine
下载PDF
The Effect of Treatment Position on Rectal and Bladder Dose-Volume Histograms for Prostate Radiotherapy Planned with 3-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy
19
作者 Kotaro Terashima Katsumasa Nakamura +10 位作者 Tomonari Sasaki Saiji Ohga Tadamasa Yoshitake Kazushige Atsumi Makoto Shinoto Kaori Asai Keiji Matsumoto Hidenari Hirata Yoshiyuki Shioyama Akihiro Nishie Hiroshi Honda 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第2期88-97,共10页
Purpose: To compare target coverage and organ at risk (OAR) sparing in the supine and prone positions with 3-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric modulated... Purpose: To compare target coverage and organ at risk (OAR) sparing in the supine and prone positions with 3-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in low- and high-risk prostate radiotherapy cases. Materials and Methods: Using magnetic resonance images of five healthy volunteers, six treatment plans (supine 3DCRT, prone 3DCRT, supine IMRT, prone IMRT, supine VMAT and prone VMAT) were generated. Planning target volume 1 (PTV1) was defined as the prostate gland plus the seminal vesicles with adequate margins in a high-risk setting, while PTV2 was defined as prostate only with margins in a low-risk setting. The mean dose for both PTV1 and PTV2 was set at 78 Gy. Plans generated by each of the 3 techniques were compared between the supine and prone positions using dose-volume histograms (DVHs). Results: For PTV1, prone 3DCRT provided a significantly higher D98% than did supine 3DCRT, and its homogeneity index (HI) was significantly better. IMRT and VMAT values did not differ significantly between the prone and supine positions. For PTV2, no values differed significantly between the supine and prone positions under any treatment plan. With respect to OAR, the rectal D mean, D2%, V50, and V60 values of PTV1 were statistically higher in supine 3DCRT than in prone 3DCRT, while there were no significant differences in rectal values between the supine and prone positions with IMRT or VMAT. The rectal Dmean, V50, V60, V70, and V75 values of prone 3DCRT were significantly higher than those of supine IMRT or supine VMAT. There were no significant differences in any values for the rectum and bladder for PTV2. Conclusion: Although prone 3DCRT was found to be superior to supine 3DCRT in terms of rectal sparing in high-risk prostate cancer, IMRT and VMAT techniques could possibly cover this disadvantage. 展开更多
关键词 PROSTATE radiotherapy Dosimetric Comparison 3DCRT IMRT VMAT
下载PDF
Enhancing Precision in Radiotherapy Delivery: Validating Monte Carlo Simulation Models for 6 MV Elekta Synergy Agility LINAC Photon Beam Using Two Models of the GAMOS Code
20
作者 Nogaye Ndiaye Oumar Ndiaye +7 位作者 Papa Macoumba Faye Kodjo Joël Fabrice N’Guessan Djicknack Dione Khady Sy Moussa Hamady Sy Jean Paul Latyr Faye Alassane Traoré Ababacar Sadikhe Ndao 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期146-163,共18页
The most crucial requirement in radiation therapy treatment planning is a fast and accurate treatment planning system that minimizes damage to healthy tissues surrounding cancer cells. The use of Monte Carlo toolkits ... The most crucial requirement in radiation therapy treatment planning is a fast and accurate treatment planning system that minimizes damage to healthy tissues surrounding cancer cells. The use of Monte Carlo toolkits has become indispensable for research aimed at precisely determining the dose in radiotherapy. Among the numerous algorithms developed in recent years, the GAMOS code, which utilizes the Geant4 toolkit for Monte Carlo simula-tions, incorporates various electromagnetic physics models and multiple scattering models for simulating particle interactions with matter. This makes it a valuable tool for dose calculations in medical applications and throughout the patient’s volume. The aim of this present work aims to vali-date the GAMOS code for the simulation of a 6 MV photon-beam output from the Elekta Synergy Agility linear accelerator. The simulation involves mod-eling the major components of the accelerator head and the interactions of the radiation beam with a homogeneous water phantom and particle information was collected following the modeling of the phase space. This space was po-sitioned under the X and Y jaws, utilizing three electromagnetic physics mod-els of the GAMOS code: Standard, Penelope, and Low-Energy, along with three multiple scattering models: Goudsmit-Saunderson, Urban, and Wentzel-VI. The obtained phase space file was used as a particle source to simulate dose distributions (depth-dose and dose profile) for field sizes of 5 × 5 cm<sup>2</sup> and 10 × 10 cm<sup>2</sup> at depths of 10 cm and 20 cm in a water phantom, with a source-surface distance (SSD) of 90 cm from the target. We compared the three electromagnetic physics models and the three multiple scattering mod-els of the GAMOS code to experimental results. Validation of our results was performed using the gamma index, with an acceptability criterion of 3% for the dose difference (DD) and 3 mm for the distance-to-agreement (DTA). We achieved agreements of 94% and 96%, respectively, between simulation and experimentation for the three electromagnetic physics models and three mul-tiple scattering models, for field sizes of 5 × 5 cm<sup>2</sup> and 10 × 10 cm<sup>2</sup> for depth-dose curves. For dose profile curves, a good agreement of 100% was found between simulation and experimentation for the three electromagnetic physics models, as well as for the three multiple scattering models for a field size of 5 × 5 cm<sup>2</sup> at 10 cm and 20 cm depths. For a field size of 10 × 10 cm<sup>2</sup>, the Penelope model dominated with 98% for 10 cm, along with the three multiple scattering models. The Penelope model and the Standard model, along with the three multiple scattering models, dominated with 100% for 20 cm. Our study, which compared these different GAMOS code models, can be crucial for enhancing the accuracy and quality of radiotherapy, contributing to more effective patient treatment. Our research compares various electro-magnetic physics models and multiple scattering models with experimental measurements, enabling us to choose the models that produce the most reli-able results, thereby directly impacting the quality of simulations. This en-hances confidence in using these models for treatment planning. Our re-search consistently contributes to the progress of Monte Carlo simulation techniques in radiation therapy, enriching the scientific literature. 展开更多
关键词 GAMOS Monte Carlo LINAC radiotherapy Dose Distribution Phase Space Gamma Index 6 MV Photon Beam
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部