In our previous work, a novel algorithm to perform robust pose estimation was presented. The pose was estimated using points on the object to regions on image correspondence. The laboratory experiments conducted in th...In our previous work, a novel algorithm to perform robust pose estimation was presented. The pose was estimated using points on the object to regions on image correspondence. The laboratory experiments conducted in the previous work showed that the accuracy of the estimated pose was over 99% for position and 84% for orientation estimations respectively. However, for larger objects, the algorithm requires a high number of points to achieve the same accuracy. The requirement of higher number of points makes the algorithm, computationally intensive resulting in the algorithm infeasible for real-time computer vision applications. In this paper, the algorithm is parallelized to run on NVIDIA GPUs. The results indicate that even for objects having more than 2000 points, the algorithm can estimate the pose in real time for each frame of high-resolution videos.展开更多
Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is ...Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.展开更多
The electrical capacitance tomography (ECT) with neural network multi-criteria image reconstruction technique (NN-MOIRT) is developed for real time imaging of a gas-solid fluidized bed using FCC particles with eva...The electrical capacitance tomography (ECT) with neural network multi-criteria image reconstruction technique (NN-MOIRT) is developed for real time imaging of a gas-solid fluidized bed using FCC particles with evaporative liquid injection. Some aspects of the fundamental characteristics of the gas-solid flow with evaporative liquid injection including real time and time averaged cross-sectional solids concentration distributions, the cross-sectional solids concentration fluctuations and the quasi-3D flow structures are studied. A two-region model and a direct image calculation are proposed to describe the dynamic behavior in both the bubble/void phase and the emulsion phase based on the tomographic images. Comparisons are made between the fundamental behaviors of the gas-solid flows with and without evaporative liquid injection for various gas velocities ranging from bubbling to turbulent fluidization regimes. Significant differences are observed in the behavior of the gas-solid flow with the evaporative liquid injection compared to the fluidized bed without liquid injection.展开更多
文摘In our previous work, a novel algorithm to perform robust pose estimation was presented. The pose was estimated using points on the object to regions on image correspondence. The laboratory experiments conducted in the previous work showed that the accuracy of the estimated pose was over 99% for position and 84% for orientation estimations respectively. However, for larger objects, the algorithm requires a high number of points to achieve the same accuracy. The requirement of higher number of points makes the algorithm, computationally intensive resulting in the algorithm infeasible for real-time computer vision applications. In this paper, the algorithm is parallelized to run on NVIDIA GPUs. The results indicate that even for objects having more than 2000 points, the algorithm can estimate the pose in real time for each frame of high-resolution videos.
文摘Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.
基金support of the National Science Foundation on the development of the ECT used in this study is gratefully acknowledged
文摘The electrical capacitance tomography (ECT) with neural network multi-criteria image reconstruction technique (NN-MOIRT) is developed for real time imaging of a gas-solid fluidized bed using FCC particles with evaporative liquid injection. Some aspects of the fundamental characteristics of the gas-solid flow with evaporative liquid injection including real time and time averaged cross-sectional solids concentration distributions, the cross-sectional solids concentration fluctuations and the quasi-3D flow structures are studied. A two-region model and a direct image calculation are proposed to describe the dynamic behavior in both the bubble/void phase and the emulsion phase based on the tomographic images. Comparisons are made between the fundamental behaviors of the gas-solid flows with and without evaporative liquid injection for various gas velocities ranging from bubbling to turbulent fluidization regimes. Significant differences are observed in the behavior of the gas-solid flow with the evaporative liquid injection compared to the fluidized bed without liquid injection.