The purpose of this paper is to study the energy efficiency of a local living space exposed to solar radiation in the subtropical climate of Casablanca. The study was mainly focused on the contribution of a phase chan...The purpose of this paper is to study the energy efficiency of a local living space exposed to solar radiation in the subtropical climate of Casablanca. The study was mainly focused on the contribution of a phase change material (PCM), inserted into a 7-cm thick air layer of a double brick wall, in two different locations. We note that the experimental study was conducted using two real-scale test cavities, located in the Faculty of Science Ain Chock-Casablanca. Two PCM mounting methods were used for the south and west walls, in order to test its energy efficiency as a storage and retrieval means of the solar flux coming from the outside. In the case of the southern wall, the PCM is put directly on the internal side of the outside part of the double wall (Case 1). For the west wall, the PCM is placed 1.2 cm away from the internal side of the outer part of the double wall (Case 2). The first result shows that the PCM placed to the wall allows storing the solar heat during the day and releasing it to the outside of the building at night. While in the second case, the PCM keeps the heat stored day and night.展开更多
A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studie...A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studies of a real OT under operating use conditions, in this research different air flow configurations, considering some air curtain solutions on the ceiling and at the sliding door always assumed to be open as a basic boundary condition, were investigated by numerical simulations. Indoor air quality (IAQ) indexes and thermal comfort parameters, deduced from simulation results were calculated and discussed referring to the best performance and efficacy between the air flow schemes to contrast the incorrect use conditions of the OT. Referring to the studied schemes, the reciprocal comparison emphasizes that a successful outcome in preventing surgical site infection can depend as much on resolving human factors (i.e. operational use conditions, door opening/closing), as on overcoming physical and technical obstacles.展开更多
A low-power complementary metal oxide semiconductor(CMOS) operational amplifier (op-amp) for real-time signal processing of micro air vehicle (MAV) is designed in this paper.Traditional folded cascode architectu...A low-power complementary metal oxide semiconductor(CMOS) operational amplifier (op-amp) for real-time signal processing of micro air vehicle (MAV) is designed in this paper.Traditional folded cascode architecture with positive channel metal oxide semiconductor(PMOS) differential input transistors and sub-threshold technology are applied under the low supply voltage.Simulation results show that this amplifier has significantly low power,while maintaining almost the same gain,bandwidth and other key performances.The power required is only 0.12 mW,which is applicable to low-power and low-voltage real-time signal acquisition and processing system.展开更多
Trichloroethylene (TCE) is a chlorinated liquid that is commonly used for metal degreasing, household and industrial dry cleaning, and in paints and glues. Tetrachloroethylene, also known as perchloroethylene (PCE), i...Trichloroethylene (TCE) is a chlorinated liquid that is commonly used for metal degreasing, household and industrial dry cleaning, and in paints and glues. Tetrachloroethylene, also known as perchloroethylene (PCE), is an excellent solvent for organic materials. PCE is volatile, highly stable, non-flammable and widely used in dry cleaning. A new method has been developed for measuring TCE and PCE in ambient air in real-time. Based upon the chemical fingerprinting and concentration levels, the method was able to isolate the source of the emissions to the responsible facility. Real-time monitoring was accomplished by utilizing a low pressure chemical ionization source (LPCI) interfaced to a tandem mass spectrometer (TAGA). Monitoring the response of specific parent/daughter ion pairs, the TAGA was used to measure concentrations of TCE and PCE. By optimizing various TAGA parameters, detection limits (DL) as low as 0.5 μg/m3 was achieved for TCE and PCE. Unlike methods using cartridge sampling and GC/MS analysis, this new method provides a real time measurement for a wide range of TCE and PCE concentrations. This unique method was applied in 2000 and 2002 to measure TCE emitted from a manufacturer of stainless steel tubing in Eastern Ontario. The maximum half-hour average concentration of TCE measured downwind of the facility was 1300 μg/m3 and the maximum instantaneous level was measured at 115,000 μg/m3. The information collected by the TAGA unit was used by the Standard Development Branch of Ontario Ministry of the Environment to adopt the half-hour Point of Impingement (POI) standard of TCE to be 36 μg/m3 in 2010. This method successfully identified and simultaneously measured TCE and PCE during a 2011 air monitoring survey of a hazardous waste disposal and treatment facility in Southern Ontario.展开更多
文摘The purpose of this paper is to study the energy efficiency of a local living space exposed to solar radiation in the subtropical climate of Casablanca. The study was mainly focused on the contribution of a phase change material (PCM), inserted into a 7-cm thick air layer of a double brick wall, in two different locations. We note that the experimental study was conducted using two real-scale test cavities, located in the Faculty of Science Ain Chock-Casablanca. Two PCM mounting methods were used for the south and west walls, in order to test its energy efficiency as a storage and retrieval means of the solar flux coming from the outside. In the case of the southern wall, the PCM is put directly on the internal side of the outside part of the double wall (Case 1). For the west wall, the PCM is placed 1.2 cm away from the internal side of the outer part of the double wall (Case 2). The first result shows that the PCM placed to the wall allows storing the solar heat during the day and releasing it to the outside of the building at night. While in the second case, the PCM keeps the heat stored day and night.
文摘A study on performances of different ventilation schemes provided by vertical and horizontal uni-directional air flow was carried out in a standard orthopaedic operating theatre (OT). Starting from our previous studies of a real OT under operating use conditions, in this research different air flow configurations, considering some air curtain solutions on the ceiling and at the sliding door always assumed to be open as a basic boundary condition, were investigated by numerical simulations. Indoor air quality (IAQ) indexes and thermal comfort parameters, deduced from simulation results were calculated and discussed referring to the best performance and efficacy between the air flow schemes to contrast the incorrect use conditions of the OT. Referring to the studied schemes, the reciprocal comparison emphasizes that a successful outcome in preventing surgical site infection can depend as much on resolving human factors (i.e. operational use conditions, door opening/closing), as on overcoming physical and technical obstacles.
基金Sponsored by the National Natural Science Foundation of China (60843005)the Basic Research Foundation of Beijing Institute of Technology(20070142018)
文摘A low-power complementary metal oxide semiconductor(CMOS) operational amplifier (op-amp) for real-time signal processing of micro air vehicle (MAV) is designed in this paper.Traditional folded cascode architecture with positive channel metal oxide semiconductor(PMOS) differential input transistors and sub-threshold technology are applied under the low supply voltage.Simulation results show that this amplifier has significantly low power,while maintaining almost the same gain,bandwidth and other key performances.The power required is only 0.12 mW,which is applicable to low-power and low-voltage real-time signal acquisition and processing system.
文摘Trichloroethylene (TCE) is a chlorinated liquid that is commonly used for metal degreasing, household and industrial dry cleaning, and in paints and glues. Tetrachloroethylene, also known as perchloroethylene (PCE), is an excellent solvent for organic materials. PCE is volatile, highly stable, non-flammable and widely used in dry cleaning. A new method has been developed for measuring TCE and PCE in ambient air in real-time. Based upon the chemical fingerprinting and concentration levels, the method was able to isolate the source of the emissions to the responsible facility. Real-time monitoring was accomplished by utilizing a low pressure chemical ionization source (LPCI) interfaced to a tandem mass spectrometer (TAGA). Monitoring the response of specific parent/daughter ion pairs, the TAGA was used to measure concentrations of TCE and PCE. By optimizing various TAGA parameters, detection limits (DL) as low as 0.5 μg/m3 was achieved for TCE and PCE. Unlike methods using cartridge sampling and GC/MS analysis, this new method provides a real time measurement for a wide range of TCE and PCE concentrations. This unique method was applied in 2000 and 2002 to measure TCE emitted from a manufacturer of stainless steel tubing in Eastern Ontario. The maximum half-hour average concentration of TCE measured downwind of the facility was 1300 μg/m3 and the maximum instantaneous level was measured at 115,000 μg/m3. The information collected by the TAGA unit was used by the Standard Development Branch of Ontario Ministry of the Environment to adopt the half-hour Point of Impingement (POI) standard of TCE to be 36 μg/m3 in 2010. This method successfully identified and simultaneously measured TCE and PCE during a 2011 air monitoring survey of a hazardous waste disposal and treatment facility in Southern Ontario.