Tri-training利用无标签数据进行分类可有效提高分类器的泛化能力,但其易将无标签数据误标,从而形成训练噪声。提出一种基于密度峰值聚类的Tri-training(Tri-training with density peaks clustering,DPC-TT)算法。密度峰值聚类通过类...Tri-training利用无标签数据进行分类可有效提高分类器的泛化能力,但其易将无标签数据误标,从而形成训练噪声。提出一种基于密度峰值聚类的Tri-training(Tri-training with density peaks clustering,DPC-TT)算法。密度峰值聚类通过类簇中心和局部密度可选出数据空间结构表现较好的样本。DPC-TT算法采用密度峰值聚类算法获取训练数据的类簇中心和样本的局部密度,对类簇中心的截断距离范围内的样本认定为空间结构表现较好,标记为核心数据,使用核心数据更新分类器,可降低迭代过程中的训练噪声,进而提高分类器的性能。实验结果表明:相比于标准Tritraining算法及其改进算法,DPC-TT算法具有更好的分类性能。展开更多
Relativistic symmetries of the Dirac equation under spin and pseudo-spin symmetries are investigated and a combina- tion of Deng-Fan and Eckart potentials with Coulomb-like and Yukawa-like tensor interaction terms are...Relativistic symmetries of the Dirac equation under spin and pseudo-spin symmetries are investigated and a combina- tion of Deng-Fan and Eckart potentials with Coulomb-like and Yukawa-like tensor interaction terms are considered. The energy equation is obtained by using the Nikiforov-Uvarov method and the corresponding wave functions are expressed in terms of the hypergeometric functions. The effects of the Coulomb and Yukawa tensor interactions are numerically discussed as well.展开更多
On December 6,CIIS,Japan Institute of International Affairs(JIIA)and Institute of Foreign Affairs and National Security,Korea National Diplomatic Academy(IFANS KNDA)co-hosted the 16th China-Japan-ROK Trilateral Cooper...On December 6,CIIS,Japan Institute of International Affairs(JIIA)and Institute of Foreign Affairs and National Security,Korea National Diplomatic Academy(IFANS KNDA)co-hosted the 16th China-Japan-ROK Trilateral Cooperation Forum.CIIS President Chen Bo,JIIA Director General Yoshida Tomoyuki and Senior Executive Director Lee Moonhee of IFANS,KNDA delivered opening remarks.Experts and scholars discussed the global and regional security situation,prospects of Asia-Pacific economic cooperation and trilateral cooperation between China,Japan and the ROK.展开更多
AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffract...AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses(IOL).METHODS:During this retrospective observational study,patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated.According to the IOLs’different types and design,the patients were divided into AT LISA tri839MP group(tri839 group)and AcrySof PanOptix TFNT00 group(TFNT group).Study parameters included preoperative and postoperative uncorrected distance visual acuity(UDVA)at 5 m,uncorrected near visual acuity(UNVA)at 30 cm and 40 cm,uncorrected intermediate visual acuity(UIVA)at 60 cm and 80 cm,postoperative refractive status,objective visual qualities and total high order aberrations(HOAs)postoperatively.The postoperative complications were also recorded.RESULTS:Totally 56 eyes of 28 patients(tri839 group,n=26;TFNT group,n=30)were included.Preoperative baseline characteristics between groups were not statistically significantly different.UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema.TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk(0.05±0.19 vs 0.15±0.10 logMAR,P=0.013),1mo(0.05±0.12 vs 0.15±0.09 logMAR,P=0.001)and 3mo(0.04±0.12 vs 0.15±0.11 logMAR,P=0.001)follow-up,while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d(0.14±0.15 vs 0.20±0.14 logMAR,P=0.041)and 1mo(0.09±0.07 vs 0.14±0.10 logMAR,P=0.042)follow-up.Postoperative refractive status showed stable at every visit.Modulated transfer function(MTF)values and strehl ratio(SR)values were improved and HOAs were lower significantly after surgery.CONCLUSION:FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision,high postoperative refractive stability and good visual quality but without significantly difference.iTrace aberration instrument can accurately evaluate the visual quality under different status.展开更多
文摘Tri-training利用无标签数据进行分类可有效提高分类器的泛化能力,但其易将无标签数据误标,从而形成训练噪声。提出一种基于密度峰值聚类的Tri-training(Tri-training with density peaks clustering,DPC-TT)算法。密度峰值聚类通过类簇中心和局部密度可选出数据空间结构表现较好的样本。DPC-TT算法采用密度峰值聚类算法获取训练数据的类簇中心和样本的局部密度,对类簇中心的截断距离范围内的样本认定为空间结构表现较好,标记为核心数据,使用核心数据更新分类器,可降低迭代过程中的训练噪声,进而提高分类器的性能。实验结果表明:相比于标准Tritraining算法及其改进算法,DPC-TT算法具有更好的分类性能。
文摘Relativistic symmetries of the Dirac equation under spin and pseudo-spin symmetries are investigated and a combina- tion of Deng-Fan and Eckart potentials with Coulomb-like and Yukawa-like tensor interaction terms are considered. The energy equation is obtained by using the Nikiforov-Uvarov method and the corresponding wave functions are expressed in terms of the hypergeometric functions. The effects of the Coulomb and Yukawa tensor interactions are numerically discussed as well.
文摘On December 6,CIIS,Japan Institute of International Affairs(JIIA)and Institute of Foreign Affairs and National Security,Korea National Diplomatic Academy(IFANS KNDA)co-hosted the 16th China-Japan-ROK Trilateral Cooperation Forum.CIIS President Chen Bo,JIIA Director General Yoshida Tomoyuki and Senior Executive Director Lee Moonhee of IFANS,KNDA delivered opening remarks.Experts and scholars discussed the global and regional security situation,prospects of Asia-Pacific economic cooperation and trilateral cooperation between China,Japan and the ROK.
基金Supported by Medical Science and Technology Research Foundation Project of Guangdong Province(No.C2021087)The Scientific Research Foundation Project of Guangzhou Aier Eye Hospital,Jinan University(No.GA2023004).
文摘AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses(IOL).METHODS:During this retrospective observational study,patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated.According to the IOLs’different types and design,the patients were divided into AT LISA tri839MP group(tri839 group)and AcrySof PanOptix TFNT00 group(TFNT group).Study parameters included preoperative and postoperative uncorrected distance visual acuity(UDVA)at 5 m,uncorrected near visual acuity(UNVA)at 30 cm and 40 cm,uncorrected intermediate visual acuity(UIVA)at 60 cm and 80 cm,postoperative refractive status,objective visual qualities and total high order aberrations(HOAs)postoperatively.The postoperative complications were also recorded.RESULTS:Totally 56 eyes of 28 patients(tri839 group,n=26;TFNT group,n=30)were included.Preoperative baseline characteristics between groups were not statistically significantly different.UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema.TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk(0.05±0.19 vs 0.15±0.10 logMAR,P=0.013),1mo(0.05±0.12 vs 0.15±0.09 logMAR,P=0.001)and 3mo(0.04±0.12 vs 0.15±0.11 logMAR,P=0.001)follow-up,while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d(0.14±0.15 vs 0.20±0.14 logMAR,P=0.041)and 1mo(0.09±0.07 vs 0.14±0.10 logMAR,P=0.042)follow-up.Postoperative refractive status showed stable at every visit.Modulated transfer function(MTF)values and strehl ratio(SR)values were improved and HOAs were lower significantly after surgery.CONCLUSION:FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision,high postoperative refractive stability and good visual quality but without significantly difference.iTrace aberration instrument can accurately evaluate the visual quality under different status.