The long time practice of observational research on earthquake prediction has shown that the information on shortterm and imminent earthquake precursors can hardly be detected, but it is very important for practical ...The long time practice of observational research on earthquake prediction has shown that the information on shortterm and imminent earthquake precursors can hardly be detected, but it is very important for practical and effective earthquake prediction. The result of analysis and study in this paper has shown that the anomaly of quasi static atmospheric electric field may be a kind of reliable information on short term and imminent earthquake precursors.On such a basis, the 20 years′ continuous and reliable data of atmospheric electric field observed at the Baijiatuan seismic station are used to study the correlation between the anomalies in seismic activity and relative quiet periods bear on the occurrence of near earthquakes within 200 km range around Beijing after the Tangshan earthquake. The observational results recently reported before hand in written form and earthquakes that actually occurred in near field in corresponding time periods are compared and analyzed. The efficacy of these written prediction opinions about near earthquakes in the recent 10 years is tested. From the test results, the brilliant prospect that the anomaly of quasi static atmospheric electric field may really become a reliable mark for making short term and imminent earthquake predictions is discussed. Besides, as a preliminary step, some judgment indexes for predicting earthquakes by use of the observational data of atmospheric electric field before earthquakes are put forward. In the last part, it is pointed out that it would be possible to obtain more believable judgment indexes for determining the three elements of near earthquakes before greater earthquakes ( M S5) only if a relatively reasonable station network (2~4 stations every 10 000 km 2) is deployed and further investigation is made.展开更多
在Visual C++ 6.0开发环境中,利用VB提供的报表控件Crystal Report Active X可实现报表及报表打印功能。其过程是:① 用Crystal Report Pro设计报表;② 在VC中添加Crystal Report Active X控件;③ 双击添加的控件,在属性页中切换到Contr...在Visual C++ 6.0开发环境中,利用VB提供的报表控件Crystal Report Active X可实现报表及报表打印功能。其过程是:① 用Crystal Report Pro设计报表;② 在VC中添加Crystal Report Active X控件;③ 双击添加的控件,在属性页中切换到Control tab并选定报表文件;④ 添加显示打印按钮和消息响应函数;⑤ 使用ODBC与数据库进行连接。展开更多
Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was ...Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was used. A total of 105 patients(210 eyes) were divided into three groups according to the type of IOLs: ZA9003(35 patients, 70 eyes), MCX11 ASP(35 patients, 70 eyes) or HQ-201HEP(35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration(SA) and total higher-order aberrations(HOAs). Results: The global score was significantly lower in the spherical IOL group than the aspherical IOL group of-020 μm SA(P < 0.05) and the aspherical IOL group of-027 μm SA(P < 0.05), and no significant difference was found in the global score between the aspherical IOL group of-020 μm SA than the aspherical IOL group of-027 μm SA(P > 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion: Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations.展开更多
<strong>Background:</strong> Computed tomography (CT) Scan is the imaging of choice for the diagnosis of sino nasal (SN) pathologies in sub-Saharan African setting. However, it is often requested by non ex...<strong>Background:</strong> Computed tomography (CT) Scan is the imaging of choice for the diagnosis of sino nasal (SN) pathologies in sub-Saharan African setting. However, it is often requested by non experienced practitioners. We aimed to describe the utility and the appropriateness of CT Scan request forms and results in the diagnosis of SN pathologies. <strong>Method:</strong> We conducted a retrospective cross-sectional study in four health facilities in Yaoundé, Cameroun, from October 2018 to September 2019. All patients to whom SN CT Scan was performed were called for an appointment. After informed consent, data on the appropriateness and conformity of the request form were collected and compared to the guidelines of the French society of radiology. CT Scan results were also collected and the quality of the report was evaluated. <strong>Results:</strong> A total of 206 SN CT Scan request forms and reports were included, with a mean patient age of 37.7 ± 16.1 years. The request form was conformed to guidelines in 8.3% of cases and was found appropriate in 62.6% of cases. No CT Scan report had all the items required, and 159 (77.2%) reports were useful. The most common diagnosis in patients with abnormal results was chronic sinusitis (49.5%) and SN polyp or polyposis (19.4%). <strong>Conclusion:</strong> Most of SN CT Scan requested were appropriate and useful. However, the conformity of request forms and reports to the guidelines is low. Suggesting the need for capacity building for the diagnosis of SN pathologies especially for non specialists like general practitioners and nurses.展开更多
文摘The long time practice of observational research on earthquake prediction has shown that the information on shortterm and imminent earthquake precursors can hardly be detected, but it is very important for practical and effective earthquake prediction. The result of analysis and study in this paper has shown that the anomaly of quasi static atmospheric electric field may be a kind of reliable information on short term and imminent earthquake precursors.On such a basis, the 20 years′ continuous and reliable data of atmospheric electric field observed at the Baijiatuan seismic station are used to study the correlation between the anomalies in seismic activity and relative quiet periods bear on the occurrence of near earthquakes within 200 km range around Beijing after the Tangshan earthquake. The observational results recently reported before hand in written form and earthquakes that actually occurred in near field in corresponding time periods are compared and analyzed. The efficacy of these written prediction opinions about near earthquakes in the recent 10 years is tested. From the test results, the brilliant prospect that the anomaly of quasi static atmospheric electric field may really become a reliable mark for making short term and imminent earthquake predictions is discussed. Besides, as a preliminary step, some judgment indexes for predicting earthquakes by use of the observational data of atmospheric electric field before earthquakes are put forward. In the last part, it is pointed out that it would be possible to obtain more believable judgment indexes for determining the three elements of near earthquakes before greater earthquakes ( M S5) only if a relatively reasonable station network (2~4 stations every 10 000 km 2) is deployed and further investigation is made.
基金supported by the Health Bureau of Shanghai City(201440029)
文摘Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was used. A total of 105 patients(210 eyes) were divided into three groups according to the type of IOLs: ZA9003(35 patients, 70 eyes), MCX11 ASP(35 patients, 70 eyes) or HQ-201HEP(35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration(SA) and total higher-order aberrations(HOAs). Results: The global score was significantly lower in the spherical IOL group than the aspherical IOL group of-020 μm SA(P < 0.05) and the aspherical IOL group of-027 μm SA(P < 0.05), and no significant difference was found in the global score between the aspherical IOL group of-020 μm SA than the aspherical IOL group of-027 μm SA(P > 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion: Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations.
文摘<strong>Background:</strong> Computed tomography (CT) Scan is the imaging of choice for the diagnosis of sino nasal (SN) pathologies in sub-Saharan African setting. However, it is often requested by non experienced practitioners. We aimed to describe the utility and the appropriateness of CT Scan request forms and results in the diagnosis of SN pathologies. <strong>Method:</strong> We conducted a retrospective cross-sectional study in four health facilities in Yaoundé, Cameroun, from October 2018 to September 2019. All patients to whom SN CT Scan was performed were called for an appointment. After informed consent, data on the appropriateness and conformity of the request form were collected and compared to the guidelines of the French society of radiology. CT Scan results were also collected and the quality of the report was evaluated. <strong>Results:</strong> A total of 206 SN CT Scan request forms and reports were included, with a mean patient age of 37.7 ± 16.1 years. The request form was conformed to guidelines in 8.3% of cases and was found appropriate in 62.6% of cases. No CT Scan report had all the items required, and 159 (77.2%) reports were useful. The most common diagnosis in patients with abnormal results was chronic sinusitis (49.5%) and SN polyp or polyposis (19.4%). <strong>Conclusion:</strong> Most of SN CT Scan requested were appropriate and useful. However, the conformity of request forms and reports to the guidelines is low. Suggesting the need for capacity building for the diagnosis of SN pathologies especially for non specialists like general practitioners and nurses.