A novel pancake Rogowski coil without magnetic core is introduced in this paper. Owing to its special pancake winding structure, the coil is of low self-resistance and high self-inductance, and thus has excellent low ...A novel pancake Rogowski coil without magnetic core is introduced in this paper. Owing to its special pancake winding structure, the coil is of low self-resistance and high self-inductance, and thus has excellent low frequency characteristic in the self-integral mode. Moreover, because of its unique installation method, the coil has a flexible sensitivity and can be applied under situations where toroidal air-core Rogowski coils or printed aircuit board (PCB) coils are not available. The parameters and performance of the pancake Rogowski coil are presented, and the principle of shielding is given. Measurements of step pulse current and oscillating pulse current by the coil are studied experimentally to illustrate its good linearity, reliable and flexible sensitivity and excellent frequency characteristic, especially its advantage in low frequency characteristic. The pancake Rogowski coil can be designed to assume round, square or rectangle shape, and has thus broad prospects in its application to the current measurement in such areas as plasma physics and pulsed power technology.展开更多
A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which...A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.展开更多
A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil ...A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil has both excellent dynamic and static characteristics. Calibrating results and the comparison between the standard current shunt and the developed Rogowski coil for the measurement of nanosecond discharge pulses demonstrate that the developed Rogowski coil can reproduce the actual waveform of the discharge current accurately.展开更多
Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and e...Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.展开更多
During the aluminum electrolytic roasting process,each component of the electrobath of aluminum performs unsteadily when the electrolytic bath is in the pre-roasting stage. It is important to monitor the currents of t...During the aluminum electrolytic roasting process,each component of the electrobath of aluminum performs unsteadily when the electrolytic bath is in the pre-roasting stage. It is important to monitor the currents of the anodes and the cathodes of the aluminum electrobath at regular intervals. Both practice and investigation indicate that Rogowski coil can be adopted to measure heavy direct current of the anodes and the cathodes of the aluminum electrobath. The paper not only introduces the typical application of the Rogowski coil to inspect the state of aluminum electrobath in the roasting process, but also analyzes the principles of the coil sensor including its dynamic properties and some important measurement results respectively. The optimal parameters of the coil can be simulated by means of an advanced simulation tool: simulink tools based on MATLAB soft environment. Based on the gathered current data, an even-current coefficient has been introduced, and the current curve can be drawn. Since they are applied in AL-Electrolyzing, it is possible to distinguish the anode of which the current is not evenly distributed, and to take adjusting measures over a period of time to ensure that the current is evenly distributed.展开更多
A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual ...A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual inductance, resistance, and capacitance of the coil. The designed Rogowski coil was calibrated under square wave voltage and arbitrary sine wave voltage. Then, according to the parameters of the Rogowski coil, the effect of changing some of these variables was simulated using a bode plot. Comparison shows that the simulation results were consistent with the experimental ones. A needle-plate in air gap model was set up and its PD under impulse voltage was measured. The results demonstrate that the Rogowski coil is adapted to measurement of PDs.展开更多
Rogowski coils(RCs)are widely used to measure power or high frequency currents based on their design.In this paper,two types of RCs that are circular(traditional)and cylindrical shapes wound using wire covered by varn...Rogowski coils(RCs)are widely used to measure power or high frequency currents based on their design.In this paper,two types of RCs that are circular(traditional)and cylindrical shapes wound using wire covered by varnish are constructed.This construction is carried out to be suitable for monitoring the discharge current of the surge arrester installed in the distribution system.Concerning high frequency RC modeling for both types considering transfer function is introduced.Self-integrating for both types is attained.Therefore,the experimental tests using function generator for both coils are carried out to identify the parameters of the transfer function representing the introduced model.The measured signals for current and induced voltages are denoised for the parameter identification process.The denoised process is achieved using the MATLAB code‘wdenoise’while the parameters are estimated using the system identification toolbox.Verification of the proposed model is achieved using experimental results for the two coils.The sensitivity of the two coils is investigated based on the induced output voltage.The application concerning the two coils for monitoring the discharge current of the surge arrester is done.The results confirm the accuracy of the introduced RC model,as well as the performance of the cylindrical shape,is better than the traditional one.The simulation is carried out using MATLAB and ATPDraw programs.展开更多
This paper systematically analyzes the transfer characteristics of the Rogowski-coil Current Transformer and its effect on protective relaying through theoretical analysis, experiments and simulations. The frequency c...This paper systematically analyzes the transfer characteristics of the Rogowski-coil Current Transformer and its effect on protective relaying through theoretical analysis, experiments and simulations. The frequency characteristics and transient characteristics of Rogowski transducer and Rogowski-coil Current Transformer are deeply analyzed based on the physical structure of the transformer.?It is revealed that broad bandwidth of the transformer can improve the performance of protective relaying, and the bandwidth is determined mainly by the parameters of the Rogowski transducer and signal processing circuits. It is also discovered that the measurement errors of transient current mainly depend on the abilities for the current transformer to reproduce an accurate replica of the decaying dc components, which is mainly decided by the decay time constant of the aperiodic component of transient current and the parameters of the integral unit. Finally, some measures are proposed for the performance improvement of Rogowski-coil Current Transformer to meet the requirements of protective relaying system in terms of structural design and testing standards.展开更多
An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high volta...An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high voltage laboratory. A multi-end measuring method is chosen as a technique to locate PD source point on the line. A power transformer is used to energize one end of the CC line by the AC voltage source. The performance of Rogowski-coil is tested in noisy environment. The tests are carried out conceming different measurement conditions such as off-line and on-line PD measuring systems. The results obtained from the laboratory measurements confirm the capability of the Rogowski-coil in order to measure and locate the high frequency PD source on the CC line in consistent with energizing AC source. Chirp detector is used as a signal-processing tool in order to extract the PD signals and then apply the locator algorithm.展开更多
Objective:To evaluate in vitro the effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt. Methods:Covalently binding procedure was performed with c...Objective:To evaluate in vitro the effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt. Methods:Covalently binding procedure was performed with chemical vapor deposition (CVD). Heparin(200 IU/ml),r-hirudin(21 nmol/ml),or fibronectin(15 μg/ml),respectively, were bound to the basic coating(poly(amino-p-xylylene-co-p-xylylen)). In vitro tests were performed on five different coating groups(n=2 each):uncoated Nitinol, basic coating,heparin-,r-hirudin-,and fibronectin-coating. Human umbilical vein endothelial cells(HUVECs) were cultured in the presence of tested coils for 48 and 72 h. Adhesion of HUVECs were evaluated with light microscopy,and with confocal laser scanning microscopy after double-staining of vinculin,phalloidin, Ki67 and fibronectin. Results: After 48 and 72 h of incubation,except HUVECs around the basic coating showing abnormal morphology, HUVECs were able to grow next to all kinds of coils. By CLSM adhering cells were typically confined to maximal three secondary coil windings. HUVECs adhered best to the fibronectin coated coils,followed by the uncoated Nitinol. HUVECs barely adhered to the basic coating. The adhesion to heparin coating or r-hirudin coating was observed with various cell densities. Heparin coating seemed to support cell adhesion better than r-hirudin coating did. The HUVECs assembled fibronectin matrix on the fibronectin coating and uncoated Nitinol coil. Vinculin was expressed on both fibronectin coating and uncoated Nitinol as well, mostly diffused,but occasionally also in focal contacts. Ki67 expression was mainly noticed on the uncoated Nitinol coil and fibronectin coated coil,only occasionally on other materials. The densities and morphology of HUVECs, adhered to the correspohding well surfaces,were similar for all wells. The only exception was the well with the basic coating coil after three days of incubation. In this case, the cell density was diminished,and the cells became more elongated. The cells grown on the well surfaces exhibited a more profound matrix assembly and more pronounced focal adhesions than the cells adhered to the coil surfaces did. Conclusion:Except for basic coating,biologically active substance coated or uncoated coils show no acute cytotoxicity on HUVECs. Due to better cell proliferation,cell matrix assembling,and focal adhesion,only fibronectin coating improves the endothelialisation of Nitinol coils.展开更多
This article discusses the use of a toroidal coil in measuring alternating current from a straight current-carrying wire passing perpendicularly through the coil. The sinusoidally oscillating current generates a sinus...This article discusses the use of a toroidal coil in measuring alternating current from a straight current-carrying wire passing perpendicularly through the coil. The sinusoidally oscillating current generates a sinusoidally oscillating magnetic field in its vicinity. This, in turn, induces a sinusoidally oscillating emf in the toroid. This (measured) emf can be used in order to calculate the magnitude of the electric current in the wire. The use of such technique might be sensitive to the location of the point at which the wire passes through the toroid. If the location is not known very precisely, this might cause errors in the value of the calculated current. We wanted to study if the result does not depend on the location of the wire at all, as is usually stated, or not. The study was done by deriving a single analytical formula for finding out the calculated current with the wire passing through any given point inside the toroid. This formula was then solved at more than 2300 points inside a toroid to see if the location of the wire affects the result or not.展开更多
基金supported by Chinese National High Technology Research and Development Program(863 Program)(No.2008AA04Z408)
文摘A novel pancake Rogowski coil without magnetic core is introduced in this paper. Owing to its special pancake winding structure, the coil is of low self-resistance and high self-inductance, and thus has excellent low frequency characteristic in the self-integral mode. Moreover, because of its unique installation method, the coil has a flexible sensitivity and can be applied under situations where toroidal air-core Rogowski coils or printed aircuit board (PCB) coils are not available. The parameters and performance of the pancake Rogowski coil are presented, and the principle of shielding is given. Measurements of step pulse current and oscillating pulse current by the coil are studied experimentally to illustrate its good linearity, reliable and flexible sensitivity and excellent frequency characteristic, especially its advantage in low frequency characteristic. The pancake Rogowski coil can be designed to assume round, square or rectangle shape, and has thus broad prospects in its application to the current measurement in such areas as plasma physics and pulsed power technology.
文摘A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.
基金supported by National Natural Science Foundation of China (No.50477027)
文摘A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil has both excellent dynamic and static characteristics. Calibrating results and the comparison between the standard current shunt and the developed Rogowski coil for the measurement of nanosecond discharge pulses demonstrate that the developed Rogowski coil can reproduce the actual waveform of the discharge current accurately.
文摘Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.
文摘During the aluminum electrolytic roasting process,each component of the electrobath of aluminum performs unsteadily when the electrolytic bath is in the pre-roasting stage. It is important to monitor the currents of the anodes and the cathodes of the aluminum electrobath at regular intervals. Both practice and investigation indicate that Rogowski coil can be adopted to measure heavy direct current of the anodes and the cathodes of the aluminum electrobath. The paper not only introduces the typical application of the Rogowski coil to inspect the state of aluminum electrobath in the roasting process, but also analyzes the principles of the coil sensor including its dynamic properties and some important measurement results respectively. The optimal parameters of the coil can be simulated by means of an advanced simulation tool: simulink tools based on MATLAB soft environment. Based on the gathered current data, an even-current coefficient has been introduced, and the current curve can be drawn. Since they are applied in AL-Electrolyzing, it is possible to distinguish the anode of which the current is not evenly distributed, and to take adjusting measures over a period of time to ensure that the current is evenly distributed.
基金The National Natural Science Foundation of China (No.50977075)
文摘A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual inductance, resistance, and capacitance of the coil. The designed Rogowski coil was calibrated under square wave voltage and arbitrary sine wave voltage. Then, according to the parameters of the Rogowski coil, the effect of changing some of these variables was simulated using a bode plot. Comparison shows that the simulation results were consistent with the experimental ones. A needle-plate in air gap model was set up and its PD under impulse voltage was measured. The results demonstrate that the Rogowski coil is adapted to measurement of PDs.
基金funded from Taif University Researchers Supporting Project number(TURSP-2020/264),Taif University,Taif,Saudi Arabia.
文摘Rogowski coils(RCs)are widely used to measure power or high frequency currents based on their design.In this paper,two types of RCs that are circular(traditional)and cylindrical shapes wound using wire covered by varnish are constructed.This construction is carried out to be suitable for monitoring the discharge current of the surge arrester installed in the distribution system.Concerning high frequency RC modeling for both types considering transfer function is introduced.Self-integrating for both types is attained.Therefore,the experimental tests using function generator for both coils are carried out to identify the parameters of the transfer function representing the introduced model.The measured signals for current and induced voltages are denoised for the parameter identification process.The denoised process is achieved using the MATLAB code‘wdenoise’while the parameters are estimated using the system identification toolbox.Verification of the proposed model is achieved using experimental results for the two coils.The sensitivity of the two coils is investigated based on the induced output voltage.The application concerning the two coils for monitoring the discharge current of the surge arrester is done.The results confirm the accuracy of the introduced RC model,as well as the performance of the cylindrical shape,is better than the traditional one.The simulation is carried out using MATLAB and ATPDraw programs.
文摘This paper systematically analyzes the transfer characteristics of the Rogowski-coil Current Transformer and its effect on protective relaying through theoretical analysis, experiments and simulations. The frequency characteristics and transient characteristics of Rogowski transducer and Rogowski-coil Current Transformer are deeply analyzed based on the physical structure of the transformer.?It is revealed that broad bandwidth of the transformer can improve the performance of protective relaying, and the bandwidth is determined mainly by the parameters of the Rogowski transducer and signal processing circuits. It is also discovered that the measurement errors of transient current mainly depend on the abilities for the current transformer to reproduce an accurate replica of the decaying dc components, which is mainly decided by the decay time constant of the aperiodic component of transient current and the parameters of the integral unit. Finally, some measures are proposed for the performance improvement of Rogowski-coil Current Transformer to meet the requirements of protective relaying system in terms of structural design and testing standards.
文摘An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high voltage laboratory. A multi-end measuring method is chosen as a technique to locate PD source point on the line. A power transformer is used to energize one end of the CC line by the AC voltage source. The performance of Rogowski-coil is tested in noisy environment. The tests are carried out conceming different measurement conditions such as off-line and on-line PD measuring systems. The results obtained from the laboratory measurements confirm the capability of the Rogowski-coil in order to measure and locate the high frequency PD source on the CC line in consistent with energizing AC source. Chirp detector is used as a signal-processing tool in order to extract the PD signals and then apply the locator algorithm.
文摘Objective:To evaluate in vitro the effect of biologically active coating on endothelialisation of Nitinol coils designed for the closure of intracardiac shunt. Methods:Covalently binding procedure was performed with chemical vapor deposition (CVD). Heparin(200 IU/ml),r-hirudin(21 nmol/ml),or fibronectin(15 μg/ml),respectively, were bound to the basic coating(poly(amino-p-xylylene-co-p-xylylen)). In vitro tests were performed on five different coating groups(n=2 each):uncoated Nitinol, basic coating,heparin-,r-hirudin-,and fibronectin-coating. Human umbilical vein endothelial cells(HUVECs) were cultured in the presence of tested coils for 48 and 72 h. Adhesion of HUVECs were evaluated with light microscopy,and with confocal laser scanning microscopy after double-staining of vinculin,phalloidin, Ki67 and fibronectin. Results: After 48 and 72 h of incubation,except HUVECs around the basic coating showing abnormal morphology, HUVECs were able to grow next to all kinds of coils. By CLSM adhering cells were typically confined to maximal three secondary coil windings. HUVECs adhered best to the fibronectin coated coils,followed by the uncoated Nitinol. HUVECs barely adhered to the basic coating. The adhesion to heparin coating or r-hirudin coating was observed with various cell densities. Heparin coating seemed to support cell adhesion better than r-hirudin coating did. The HUVECs assembled fibronectin matrix on the fibronectin coating and uncoated Nitinol coil. Vinculin was expressed on both fibronectin coating and uncoated Nitinol as well, mostly diffused,but occasionally also in focal contacts. Ki67 expression was mainly noticed on the uncoated Nitinol coil and fibronectin coated coil,only occasionally on other materials. The densities and morphology of HUVECs, adhered to the correspohding well surfaces,were similar for all wells. The only exception was the well with the basic coating coil after three days of incubation. In this case, the cell density was diminished,and the cells became more elongated. The cells grown on the well surfaces exhibited a more profound matrix assembly and more pronounced focal adhesions than the cells adhered to the coil surfaces did. Conclusion:Except for basic coating,biologically active substance coated or uncoated coils show no acute cytotoxicity on HUVECs. Due to better cell proliferation,cell matrix assembling,and focal adhesion,only fibronectin coating improves the endothelialisation of Nitinol coils.
文摘This article discusses the use of a toroidal coil in measuring alternating current from a straight current-carrying wire passing perpendicularly through the coil. The sinusoidally oscillating current generates a sinusoidally oscillating magnetic field in its vicinity. This, in turn, induces a sinusoidally oscillating emf in the toroid. This (measured) emf can be used in order to calculate the magnitude of the electric current in the wire. The use of such technique might be sensitive to the location of the point at which the wire passes through the toroid. If the location is not known very precisely, this might cause errors in the value of the calculated current. We wanted to study if the result does not depend on the location of the wire at all, as is usually stated, or not. The study was done by deriving a single analytical formula for finding out the calculated current with the wire passing through any given point inside the toroid. This formula was then solved at more than 2300 points inside a toroid to see if the location of the wire affects the result or not.