期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
INVESTIGATION ON COMPLIANCE ROTATION CORRECTION FOR COMPACT TENSILE SPECIMEN IN UNLOADING COMPLIANCE METHOD 被引量:3
1
作者 Chen Bao Lixun Cai 《Acta Mechanica Solida Sinica》 SCIE EI 2011年第2期144-152,共9页
The rotation correction method of unloading compliance for a compact tensile (CT) specimen in the current J-integral resistance curves or critical J-integral test standards was under suspicion by tracing to its sour... The rotation correction method of unloading compliance for a compact tensile (CT) specimen in the current J-integral resistance curves or critical J-integral test standards was under suspicion by tracing to its source, and a new rotation correction method was proposed. The rotation center of the specimen is close to the crack tip, and the material constitutive relationship has little effect on the rotational radius R. If the formula for rotation correction recommended in current standards is used to measure the crack length of CT specimen, it will lead to larger error. A new formula with better accuracy for the crack length measurement of the CT specimen was presented. 展开更多
关键词 ductile fracture toughness unloading compliance compact tensile specimen rotation correction
原文传递
Stick-slip nonuniform rotation distortion correction in distal scanning optical coherence tomography catheters
2
作者 Jessica Mavadia-Shukla Jianlin Zhang +1 位作者 Kaiyan Li Xingde Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2020年第6期94-101,共8页
We present a robust and fiducial-marker-free algorithm that can identify and correct stick-slip distortion caused by nonuniform rotation(or beam scanning)in distally scanned catheters for endoscopic optical coherence ... We present a robust and fiducial-marker-free algorithm that can identify and correct stick-slip distortion caused by nonuniform rotation(or beam scanning)in distally scanned catheters for endoscopic optical coherence tomography(OCT)images.This algorithm employs spatial fre-quency analysis to select and remove distortions.We demonstrate the feasibility of this algorithm on images acquired from ex vivo rat colon with a distally scanned DC motor-based endoscope.The proposed algorithm can be applied to general endoscopic OCT images for correcting non-uniform rotation distortion. 展开更多
关键词 Optical coherence tomography nonuniform rotation distortion correction ENDOSCOPE distal-scanning
下载PDF
Center-of-mass correction and rotational correction in covariant density functional theory
3
作者 李兆玺 李志攀 《Chinese Physics C》 SCIE CAS CSCD 2015年第11期32-35,共4页
Center-of-mass(c.m.) correction and rotational correction in even-even Ge isotopes are systematically investigated within the triaxially deformed relativistic Hartree-Bogoliubov model using the PC-PK1 force. The she... Center-of-mass(c.m.) correction and rotational correction in even-even Ge isotopes are systematically investigated within the triaxially deformed relativistic Hartree-Bogoliubov model using the PC-PK1 force. The shell effect and deformation effect on the microscopic c.m. correction and rotational correction are discussed, and the importance of both corrections on reproducing the binding energy is demonstrated. 展开更多
关键词 center-of-mass correction rotational correction even-even Ge isotopes covariant density functional theory
原文传递
Panoramic camera on the Yutu lunar rover of the Chang'e-3 mission
4
作者 Jian-Feng Yang Chun-Lai Li +10 位作者 Bin Xue Ping Ruan Wei Gao Wei-Dong Qiao Di Lu Xiao-Long Ma Fu Li Ying-Hong He Ting Li Xin Ren Xing-Tao Yan 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2015年第11期1867-1880,共14页
The Chang'e-3 panoramic camera, which is composed of two cameras with identical functions, performances and interfaces, is installed on the lunar rover mast. It can acquire 3D images of the lunar surface based on the... The Chang'e-3 panoramic camera, which is composed of two cameras with identical functions, performances and interfaces, is installed on the lunar rover mast. It can acquire 3D images of the lunar surface based on the principle of binocular stereo vision. By rotating and pitching the mast, it can take several photographs of the patrol area. After stitching these images, panoramic images of the scenes will be obtained.Thus the topography and geomorphology of the patrol area and the impact crater, as well as the geological structure of the lunar surface, will be analyzed and studied.In addition, it can take color photographs of the lander using the Bayer color coding principle. It can observe the working status of the lander by switching between static image mode and dynamic video mode with automatic exposure time. The focal length of the lens on the panoramic camera is 50 mm and the field of view is 19.7?umination and viewing conditions, the largest signal-to-no×14.5?.Under the best illise ratio of the panoramic camera is 44 d B. Its static modulation transfer function is 0.33. A large number of ground testing experiments and on-orbit imaging results show that the functional interface of the panoramic camera works normally. The image quality of the panoramic camera is satisfactory. All the performance parameters of the panoramic camera satisfy the design requirements. 展开更多
关键词 camera rover lunar viewing satisfactory calibration Bayer correction rotating satisfy
下载PDF
Magnetic fluid based deformable mirror for aberration correction of liquid telescope
5
作者 吴君秋 吴智政 +2 位作者 孔祥会 张柱 刘梅 《Optoelectronics Letters》 EI 2017年第2期90-94,共5页
A magnetic fluid based deformable mirror(MFDM) that could produce a large stroke more than 100 μm is designed and demonstrated experimentally with respect to the characteristics of the aberration of the liquid telesc... A magnetic fluid based deformable mirror(MFDM) that could produce a large stroke more than 100 μm is designed and demonstrated experimentally with respect to the characteristics of the aberration of the liquid telescope. Its aberration correction performance is verified by the co-simulation using COMSOL and MATLAB. Furthermore, the stroke performance of the MFDM and the decentralized linear quadratic Gaussian(LQG) mirror surface control approach are experimentally evaluated with a prototype of MFDM in an adaptive optics system to show its potential application for the large aberration correction of liquid telescopes. 展开更多
关键词 aberration mirror correction decentralized wavefront verified optics quadratic rotation telescope
原文传递
Comparative study of nuclear masses in the relativistic mean-field model 被引量:4
6
作者 HUA XueMin HENG TaiHua +2 位作者 NIU ZhongMing SUN BaoHua GUO JianYou 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2012年第12期2414-2419,共6页
With experimental masses updated from AME11,the predictive power of relativistic mean-field(RMF) mass model is carefully examined and compared with HFB-17,FRDM,WS*,and DZ28 mass models.In the relativistic mean-field m... With experimental masses updated from AME11,the predictive power of relativistic mean-field(RMF) mass model is carefully examined and compared with HFB-17,FRDM,WS*,and DZ28 mass models.In the relativistic mean-field model,the calculation with the PC-PK1 has improved significantly in describing masses compared to the TMA,especially for the neutron-deficient nuclei.The corresponding rms deviation with respect to the known masses falls to 1.4 MeV.Furthermore,it is found that the RMF mass model better describes the nuclei with large deformations.The rms deviation for nuclei with the absolute value of quadrupole deformation parameter greater than 0.25 falls to 0.93,crossing the 1 MeV accuracy threshold for the PC-PK1,which may indicate the new model is more suitable for those largely-deformed nuclei.In addition,the necessity of new high-precision experimental data to evaluate and develop the nuclear mass models is emphasized as well. 展开更多
关键词 nuclear masses relativistic mean-field model rotational correction
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部