The interaction of ruthenated porphyrin [Ru(bpy) 2(MPyTPP)Cl] + with CT-DNA was investigated with UV-Vis and fluorescent spectrum. It is found that [Ru(bpy) 2(MPyTPP)Cl] + binds to CT-DNA with a high affinity.
Tris(bipyridine)ruthenium(Ⅱ)(Ru(bpy) 2+ 3) was incorporated into mesoporous silicate MCM 48. X ray diffraction and emission spectroscopy were used to investigate the products, Ru(bpy) 2+ 3/MCM 48. The emission spectr...Tris(bipyridine)ruthenium(Ⅱ)(Ru(bpy) 2+ 3) was incorporated into mesoporous silicate MCM 48. X ray diffraction and emission spectroscopy were used to investigate the products, Ru(bpy) 2+ 3/MCM 48. The emission spectra show that the wavelength of maximum intensity( λ max ) for Ru(bpy) 2+ 3 increases with the increase of Ru(bpy) 2+ 3 loading level in MCM 48. The photoluminescent property of Ru(bpy) 2+ 3/MCM 48 was investigated. It was observed that the wavelength maximum intensity( λ max ) for Ru(bpy) 2+ 3/MCM 48 was red shifted when acetone vapor was introduced. [WT5HZ]展开更多
The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied ...The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied to the determination of several amino acids without prior derivatization with high sensitivity. The cathodic electrochemiluminescence(ECL) exhibits the detection limits and linear ranges of several amino acids comparable to or better than those of capillary electrophoresis with conventional ECL detection method(at 1.10-1.20 V vs. Ag/AgCl) based on precolumn derivatization. The results suggest that the cathodic ECL is promising for the detection of amino acids in bioanalysis.展开更多
Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, lig...Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, light emission intensity was found to be linear with rutin in the range of 1-50μmol/L.展开更多
Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determine quercetin. It was found that ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of quercetin in basic solution, and the enhanced ...Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determine quercetin. It was found that ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of quercetin in basic solution, and the enhanced light emission intensity was proportional to the concentration of quercetin over the range of 1×10^-6 mol/L to 2×10^4 mol/L.展开更多
文摘The interaction of ruthenated porphyrin [Ru(bpy) 2(MPyTPP)Cl] + with CT-DNA was investigated with UV-Vis and fluorescent spectrum. It is found that [Ru(bpy) 2(MPyTPP)Cl] + binds to CT-DNA with a high affinity.
文摘Tris(bipyridine)ruthenium(Ⅱ)(Ru(bpy) 2+ 3) was incorporated into mesoporous silicate MCM 48. X ray diffraction and emission spectroscopy were used to investigate the products, Ru(bpy) 2+ 3/MCM 48. The emission spectra show that the wavelength of maximum intensity( λ max ) for Ru(bpy) 2+ 3 increases with the increase of Ru(bpy) 2+ 3 loading level in MCM 48. The photoluminescent property of Ru(bpy) 2+ 3/MCM 48 was investigated. It was observed that the wavelength maximum intensity( λ max ) for Ru(bpy) 2+ 3/MCM 48 was red shifted when acetone vapor was introduced. [WT5HZ]
基金Supported by the National Natural Science Foundation of China(No.20605020)the Distinguished Young Scholars of Jilin Province, China(No.20060112)the Fundamental Research Funds for the Central Universities(No.DL09BB25)
文摘The unique cathodic electrochemiluminescence(ECL) emission of Ru(bpy)3^2+(bpy=2,2′-bipyridine) was observed via Nation film at Au electrode[Au/Nafion/Ru(bpy)3^2+] at about 0.20 V(vs. Ag/AgCl) and applied to the determination of several amino acids without prior derivatization with high sensitivity. The cathodic electrochemiluminescence(ECL) exhibits the detection limits and linear ranges of several amino acids comparable to or better than those of capillary electrophoresis with conventional ECL detection method(at 1.10-1.20 V vs. Ag/AgCl) based on precolumn derivatization. The results suggest that the cathodic ECL is promising for the detection of amino acids in bioanalysis.
基金This work was supported by the National Natural Science Foundation of China (No. 20475004);Instrumental Analysis Fund of Peking University.
文摘Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determination of rutin. ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of rufin in basic solution on platinum electrode. At pH 9.9, light emission intensity was found to be linear with rutin in the range of 1-50μmol/L.
基金This work was supported by the National Natural Science Foundation of China(No.20475004).
文摘Ru(bpy)3^2+ electrochemiluminescence (ECL) was applied to determine quercetin. It was found that ECL intensity of Ru(bpy)3^2+ could be enhanced in the presence of quercetin in basic solution, and the enhanced light emission intensity was proportional to the concentration of quercetin over the range of 1×10^-6 mol/L to 2×10^4 mol/L.