When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform...When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform(ST)and average singular entropy(ASE)is proposed to identify HIFs.First,a wavelet packet transform(WPT)was applied to extract the feature frequency band.Thereafter,the ST was investigated in each half cycle.Afterwards,the obtained time-frequency matrix was denoised by singular value decomposition(SVD),followed by the calculation of the ASE index.Finally,an appropriate threshold was selected to detect the HIFs.The advantages of this method are the ability of fine band division,adaptive time-frequency transformation,and quantitative expression of signal complexity.The performance of the proposed method was verified by simulated and field data,and further analysis revealed that it could still achieve good results under different conditions.展开更多
Aiming at the problems of multiple types of power quality composite disturbances,strong feature correlation and high recognition error rate,a method of power quality composite disturbances identification based on mult...Aiming at the problems of multiple types of power quality composite disturbances,strong feature correlation and high recognition error rate,a method of power quality composite disturbances identification based on multiresolution S-transform and decision tree was proposed.Firstly,according to IEEE standard,the signal models of seven single power quality disturbances and 17 combined power quality disturbances are given,and the disturbance waveform samples are generated in batches.Then,in order to improve the recognition accuracy,the adjustment factor is introduced to obtain the controllable time-frequency resolution through multi-resolution S-transform time-frequency domain analysis.On this basis,five disturbance time-frequency domain features are extracted,which quantitatively reflect the characteristics of the analyzed power quality disturbance signal,which is less than the traditional method based on S-transform.Finally,three classifiers such as K-nearest neighbor,support vector machine and decision tree algorithm are used to effectively complete the identification of power quality composite disturbances.Simulation results showthat the classification accuracy of decision tree algorithmis higher than that of K-nearest neighbor and support vector machine.Finally,the proposed method is compared with other commonly used recognition algorithms.Experimental results show that the proposedmethod is effective in terms of detection accuracy,especially for combined PQ interference.展开更多
In this paper, we analyze the seismic signal in the time-frequency domain using the generalized S-transform combined with spectrum modeling. Without assuming that the reflection coefficients are random white noise as ...In this paper, we analyze the seismic signal in the time-frequency domain using the generalized S-transform combined with spectrum modeling. Without assuming that the reflection coefficients are random white noise as in the conventional resolution-enhanced techniques, the wavelet which changes with time and frequency was simulated and eliminated. After using the inverse S-transform for the processed instantaneous spectrum, the signal in the time domain was obtained again with a more balanced spectrum and broader frequency band. The quality of seismic data was improved without additional noise.展开更多
<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics o...<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics of different frequency components in the signal. In this paper, a novel protection method for VSC-HVDC (Voltage source converter based high voltage DC) based on Generalized S-transform is proposed. Firstly, extracting frequency component of fault current by Generalized S-transform and using mutation point of high frequency to determine the fault time. Secondly, using the zero-frequency component of fault current to eliminate disturbances. Finally, the polarity of sudden change currents in the two terminals is employed to discriminate the internal and external faults. Simulations in PSCAD/EMTDC and MATLAB show that the proposed method can distinguish faults accurately and effectively. </div>展开更多
Ocular artifacts are most unwanted disturbance in electroencephalograph (EEG) signals. These are characterized by high amplitude but have overlap-ping frequency band with the useful signal. Hence, it is difficult to r...Ocular artifacts are most unwanted disturbance in electroencephalograph (EEG) signals. These are characterized by high amplitude but have overlap-ping frequency band with the useful signal. Hence, it is difficult to remove the ocular artifacts by traditional filtering methods. This paper proposes a new approach of artifact removal using S-transform (ST). It provides an instantaneous time-frequency repre-sentation of a time-varying signal and generates high magnitude S-coefficients at the instances of abrupt changes in the signal. A threshold function has been defined in S-domain to detect the artifact zone in the signal. The artifact has been attenuated by a suitable multiplying factor. The major advantage of ST-fil- tering is that the artifacts may be removed within a narrow time-window, while preserving the frequency information at all other time points. It also preserves the absolutely referenced phase information of the signal after the removal of artifacts. Finally, a com-parative study with wavelet transform (WT) and in-dependent component analysis (ICA) demonstrates the effectiveness of the proposed approach.展开更多
Cognitive Radio (CR) uses the principle of dynamic spectrum allocation to improve the utilization of spectrum bands. The estimation of missing data is essential for maintaining an uninterrupted quality of service in t...Cognitive Radio (CR) uses the principle of dynamic spectrum allocation to improve the utilization of spectrum bands. The estimation of missing data is essential for maintaining an uninterrupted quality of service in the CR. However, the existing methods are not suitable for interpolating missing data in high frequency signals. The storage of spectrum occupancy information is crucial for learning the spectrum usage and prediction. The existing techniques for wideband spectrum sensing suffer from poor edge detection capabilities. This paper proposes an STransformation (ST) based approach to solve these problems. For missing samples, the proposed method improves the accuracy of estimation. The ST can also be used to store the spectrum occupancy information. The simulation results show that the proposed scheme outperforms others by improving the accuracy of edge detection. Further, the simple implementation of the ST in the frequency domain is an advantage for the real time application.展开更多
The characteristic property of white Gaussian noise (WGN) is derived in S-transformation domain. The results show that the distribution of normalized S-spectrum of WGN follows X2?distribution with two degrees of freed...The characteristic property of white Gaussian noise (WGN) is derived in S-transformation domain. The results show that the distribution of normalized S-spectrum of WGN follows X2?distribution with two degrees of freedom. The conclusion has been confirmed through both theoretical derivations and numerical simulations. Combined with different criteria, an effective signal detection in S-transformation can be realized.展开更多
In this paper, a SVM classifier based on S-Transform is presented for power quality disturbances classification. Firstly, seven types of PQ events are created using Matlab simulation. These signals are analyzed to det...In this paper, a SVM classifier based on S-Transform is presented for power quality disturbances classification. Firstly, seven types of PQ events are created using Matlab simulation. These signals are analyzed to detect and localize PQ events via S-Transform by visual inspection. Then five significant features of the PQ disturbances are extracted from the S-Transform output. Afterwards, PQ disturbance samples with the five features are fed to SVM for training and automatic classification. Besides, particle swarm optimization is implemented to improve the performance of SVM. The results of the classification indicate that SVM classifier is an effective mechanism to detect and classify power quality disturbances.展开更多
As a relatively new method of processing non-stationary signal with high time-frequency resolution, S transform can be used to analyze the time-frequency characteristics of seismic signals. It has the following charac...As a relatively new method of processing non-stationary signal with high time-frequency resolution, S transform can be used to analyze the time-frequency characteristics of seismic signals. It has the following characteristics: its time-frequency resolution corresponding to the signal frequency, reversible inverse transform, basic wavelet that does not have to meet the permit conditions. We combined the threshold method, proposed the S-transform threshold filtering on the basis of S transform timefrequency filtering, and processed airgun seismic records from temporary stations in "Yangtze Program"(the Anhui experiment). Compared with the results of the bandpass filtering, the S transform threshold filtering can improve the signal to noise ratio(SNR) of seismic waves and provide effective help for first arrival pickup and accurate travel time. The first arrival wave seismic phase can be traced farther continuously, and the Pm seismic phase in the subsequent zone is also highlighted.展开更多
基金financial supported by the Natural Science Foundation of Fujian,China(2021J01633).
文摘When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform(ST)and average singular entropy(ASE)is proposed to identify HIFs.First,a wavelet packet transform(WPT)was applied to extract the feature frequency band.Thereafter,the ST was investigated in each half cycle.Afterwards,the obtained time-frequency matrix was denoised by singular value decomposition(SVD),followed by the calculation of the ASE index.Finally,an appropriate threshold was selected to detect the HIFs.The advantages of this method are the ability of fine band division,adaptive time-frequency transformation,and quantitative expression of signal complexity.The performance of the proposed method was verified by simulated and field data,and further analysis revealed that it could still achieve good results under different conditions.
基金Foundation of China(No.52067013)the Key Natural Science Fund Project of Gansu Provincial Department of Science and Technology(No.21JR7RA280)+1 种基金the Tianyou Innovation Team Science Foundation of Intelligent Power Supply and State Perception for Rail Transit(No.TY202010)the Natural Science Foundation of Gansu Province(No.20JR5RA395).
文摘Aiming at the problems of multiple types of power quality composite disturbances,strong feature correlation and high recognition error rate,a method of power quality composite disturbances identification based on multiresolution S-transform and decision tree was proposed.Firstly,according to IEEE standard,the signal models of seven single power quality disturbances and 17 combined power quality disturbances are given,and the disturbance waveform samples are generated in batches.Then,in order to improve the recognition accuracy,the adjustment factor is introduced to obtain the controllable time-frequency resolution through multi-resolution S-transform time-frequency domain analysis.On this basis,five disturbance time-frequency domain features are extracted,which quantitatively reflect the characteristics of the analyzed power quality disturbance signal,which is less than the traditional method based on S-transform.Finally,three classifiers such as K-nearest neighbor,support vector machine and decision tree algorithm are used to effectively complete the identification of power quality composite disturbances.Simulation results showthat the classification accuracy of decision tree algorithmis higher than that of K-nearest neighbor and support vector machine.Finally,the proposed method is compared with other commonly used recognition algorithms.Experimental results show that the proposedmethod is effective in terms of detection accuracy,especially for combined PQ interference.
基金supported by National 973 Key Basic Research Development Program(No.2007CB209602)National 863 High Technology Research Development Program (No.2007AA067.229)
文摘In this paper, we analyze the seismic signal in the time-frequency domain using the generalized S-transform combined with spectrum modeling. Without assuming that the reflection coefficients are random white noise as in the conventional resolution-enhanced techniques, the wavelet which changes with time and frequency was simulated and eliminated. After using the inverse S-transform for the processed instantaneous spectrum, the signal in the time domain was obtained again with a more balanced spectrum and broader frequency band. The quality of seismic data was improved without additional noise.
文摘<div style="text-align:justify;"> Generalized S-transform is a time-frequency analysis method which has higher resolution than S-transform. It can precisely extract the time-amplitude characteristics of different frequency components in the signal. In this paper, a novel protection method for VSC-HVDC (Voltage source converter based high voltage DC) based on Generalized S-transform is proposed. Firstly, extracting frequency component of fault current by Generalized S-transform and using mutation point of high frequency to determine the fault time. Secondly, using the zero-frequency component of fault current to eliminate disturbances. Finally, the polarity of sudden change currents in the two terminals is employed to discriminate the internal and external faults. Simulations in PSCAD/EMTDC and MATLAB show that the proposed method can distinguish faults accurately and effectively. </div>
文摘Ocular artifacts are most unwanted disturbance in electroencephalograph (EEG) signals. These are characterized by high amplitude but have overlap-ping frequency band with the useful signal. Hence, it is difficult to remove the ocular artifacts by traditional filtering methods. This paper proposes a new approach of artifact removal using S-transform (ST). It provides an instantaneous time-frequency repre-sentation of a time-varying signal and generates high magnitude S-coefficients at the instances of abrupt changes in the signal. A threshold function has been defined in S-domain to detect the artifact zone in the signal. The artifact has been attenuated by a suitable multiplying factor. The major advantage of ST-fil- tering is that the artifacts may be removed within a narrow time-window, while preserving the frequency information at all other time points. It also preserves the absolutely referenced phase information of the signal after the removal of artifacts. Finally, a com-parative study with wavelet transform (WT) and in-dependent component analysis (ICA) demonstrates the effectiveness of the proposed approach.
文摘Cognitive Radio (CR) uses the principle of dynamic spectrum allocation to improve the utilization of spectrum bands. The estimation of missing data is essential for maintaining an uninterrupted quality of service in the CR. However, the existing methods are not suitable for interpolating missing data in high frequency signals. The storage of spectrum occupancy information is crucial for learning the spectrum usage and prediction. The existing techniques for wideband spectrum sensing suffer from poor edge detection capabilities. This paper proposes an STransformation (ST) based approach to solve these problems. For missing samples, the proposed method improves the accuracy of estimation. The ST can also be used to store the spectrum occupancy information. The simulation results show that the proposed scheme outperforms others by improving the accuracy of edge detection. Further, the simple implementation of the ST in the frequency domain is an advantage for the real time application.
文摘The characteristic property of white Gaussian noise (WGN) is derived in S-transformation domain. The results show that the distribution of normalized S-spectrum of WGN follows X2?distribution with two degrees of freedom. The conclusion has been confirmed through both theoretical derivations and numerical simulations. Combined with different criteria, an effective signal detection in S-transformation can be realized.
文摘In this paper, a SVM classifier based on S-Transform is presented for power quality disturbances classification. Firstly, seven types of PQ events are created using Matlab simulation. These signals are analyzed to detect and localize PQ events via S-Transform by visual inspection. Then five significant features of the PQ disturbances are extracted from the S-Transform output. Afterwards, PQ disturbance samples with the five features are fed to SVM for training and automatic classification. Besides, particle swarm optimization is implemented to improve the performance of SVM. The results of the classification indicate that SVM classifier is an effective mechanism to detect and classify power quality disturbances.
基金funded by the National Natural Science Foundation Item (41674068)Seismic Youth Funding of GEC (YFGEC2016001)
文摘As a relatively new method of processing non-stationary signal with high time-frequency resolution, S transform can be used to analyze the time-frequency characteristics of seismic signals. It has the following characteristics: its time-frequency resolution corresponding to the signal frequency, reversible inverse transform, basic wavelet that does not have to meet the permit conditions. We combined the threshold method, proposed the S-transform threshold filtering on the basis of S transform timefrequency filtering, and processed airgun seismic records from temporary stations in "Yangtze Program"(the Anhui experiment). Compared with the results of the bandpass filtering, the S transform threshold filtering can improve the signal to noise ratio(SNR) of seismic waves and provide effective help for first arrival pickup and accurate travel time. The first arrival wave seismic phase can be traced farther continuously, and the Pm seismic phase in the subsequent zone is also highlighted.
文摘依据FFT→优化窗→IFFT思路,突破线性时频变换的窗函数积分性能桎梏,实现高性能优化窗函数的线性时频变换应用,建立新型时频变换算法——K-S变换.对信号x(t)的FFT频谱向量进行频移处理后,与该频移点下Kaiser优化窗的频谱向量进行Hadamard乘积,再将乘积结果进行FFT逆变换(IFFT),构造出K-S变换复时频矩阵,由此获得x(t)的时间-频率-幅值、时间-频率-相位三维信息;给出逆变换的数学推导与局部性质、线性性质和变分辨率特性;0~150 kHz电网的稳态与时变超谐波信号仿真实验表明,K-S变换的时域、频域分辨能力均优于流行的短时傅里叶变换、S变换,具有优良的变分辨率性能;0~40 kHz超谐波信号的实测证明,基于K-S变换的超谐波电压幅值测量绝对误差均小于0.032 3 V.