The FDR automatic soil moisture sensor must determine reference frequency in the air and water. Experimental studies show that the water reference frequency is influenced by water temperature. The variation of the ref...The FDR automatic soil moisture sensor must determine reference frequency in the air and water. Experimental studies show that the water reference frequency is influenced by water temperature. The variation of the reference frequency of the sensor is measured with the change of the water temperature,then analysis the influence of the volume water content measurement of the sensor,analysis found that the error is not more than 3% for the measurement of the volumetric water content of the temperature.展开更多
A design method of an intelligent temperature control system based on single-chip microcomputer is presented in this paper. The intelligent temperature control system is divided into four parts: monitor,heater,control...A design method of an intelligent temperature control system based on single-chip microcomputer is presented in this paper. The intelligent temperature control system is divided into four parts: monitor,heater,controlled process and feedback loop. Among them,the temperature detection circuit is designed with the conductivity of water by sensor detection. The optical coupler MOC3041 is used to implement the power control circuit,whose control object is 1 kW electric heater with the 220 V alternating current power; keyboard and display circuit SMC1602A include four buttons and LCD display to achieve human-computer interaction; Based on single-chip system STC89C52,the sensor signal and keyboard set target temperature are compared to the power automatically in order to finish the water temperature control. Through the static and dynamic data testing,the results show that the proposed method provides an effective way to realize the real-time acquisition and control of temperature.展开更多
An active temperature compensated fiber Bragg grating(FBG)vibration sensor with a constant section cantilever beam is proposed for the simultaneous measurement of temperature and vibration,and the sensor is verified b...An active temperature compensated fiber Bragg grating(FBG)vibration sensor with a constant section cantilever beam is proposed for the simultaneous measurement of temperature and vibration,and the sensor is verified by a temperature compensation feedback system.The high-temperature vibration sensor is composed of a quartz cantilever beam and a femtosecond Bragg grating.The feedback control demodulation system of active temperature compensation can adjust the laser wavelength to stabilize the grating offset point and realize simultaneous measurement of temperature and vibration.On this basis,the performance of the sensor is tested and analyzed within the range of 20-400℃by setting up a high-temperature vibration test system.The experimental results show that the sensitivity of the sensor is about 132.33 mV/g,and the nonlinearity is about 3.33%.The sensitivity between the laser wavelength and temperature is about 0.01307 nm/℃.In addition,the active temperature compensated fiber Bragg grating vibration sensor has the advantages of a simple structure,stable performance,easy demodulation and high sensitivity.Moreover,the sensor can achieve high temperature vibration signal monitoring and has good practical application value.展开更多
The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibil...The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.展开更多
When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ a...When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.展开更多
文摘The FDR automatic soil moisture sensor must determine reference frequency in the air and water. Experimental studies show that the water reference frequency is influenced by water temperature. The variation of the reference frequency of the sensor is measured with the change of the water temperature,then analysis the influence of the volume water content measurement of the sensor,analysis found that the error is not more than 3% for the measurement of the volumetric water content of the temperature.
基金Sponsored by the Fundamental Research Funds for Heilongjiang Postdoctoral Grant(Grant No.LRB11-334)Natural Science Foundation of Heilongjiang Province(Grant No.QC2013C035)+1 种基金Heilongjiang Province Education Department of Science and Technology Research Foundation(Grant No.12533014)the Foundamental Research Funds for the Central Universities(Grant No.2572014CB13)
文摘A design method of an intelligent temperature control system based on single-chip microcomputer is presented in this paper. The intelligent temperature control system is divided into four parts: monitor,heater,controlled process and feedback loop. Among them,the temperature detection circuit is designed with the conductivity of water by sensor detection. The optical coupler MOC3041 is used to implement the power control circuit,whose control object is 1 kW electric heater with the 220 V alternating current power; keyboard and display circuit SMC1602A include four buttons and LCD display to achieve human-computer interaction; Based on single-chip system STC89C52,the sensor signal and keyboard set target temperature are compared to the power automatically in order to finish the water temperature control. Through the static and dynamic data testing,the results show that the proposed method provides an effective way to realize the real-time acquisition and control of temperature.
基金National Natural Science Foundation of China(No.51935011)Natural Science Foundation of Shanxi Province of China(No.201901D111160)Innovative Research Group Project of National Science Foundation of China(No.51821003)。
文摘An active temperature compensated fiber Bragg grating(FBG)vibration sensor with a constant section cantilever beam is proposed for the simultaneous measurement of temperature and vibration,and the sensor is verified by a temperature compensation feedback system.The high-temperature vibration sensor is composed of a quartz cantilever beam and a femtosecond Bragg grating.The feedback control demodulation system of active temperature compensation can adjust the laser wavelength to stabilize the grating offset point and realize simultaneous measurement of temperature and vibration.On this basis,the performance of the sensor is tested and analyzed within the range of 20-400℃by setting up a high-temperature vibration test system.The experimental results show that the sensitivity of the sensor is about 132.33 mV/g,and the nonlinearity is about 3.33%.The sensitivity between the laser wavelength and temperature is about 0.01307 nm/℃.In addition,the active temperature compensated fiber Bragg grating vibration sensor has the advantages of a simple structure,stable performance,easy demodulation and high sensitivity.Moreover,the sensor can achieve high temperature vibration signal monitoring and has good practical application value.
基金supported by the National Natural Science Foundation of China under Grant No. 60608009Science Foundation of Zhejiang Province under Grant No. Y107091 and ScienceTechnology Department of Zhejiang Province under Grant No. 2008C21172.
文摘The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.
基金Supported by Jiangsu Agricultural Self-innovation Fund[CX(13)3031]~~
文摘When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.