The study of sulfur hexafluoride(SF6) discharge is vital for its application in gas-insulated equipment. Direct current partial discharge(PD) may cause SF6 decomposition, and the decomposed products of SF6, such as F ...The study of sulfur hexafluoride(SF6) discharge is vital for its application in gas-insulated equipment. Direct current partial discharge(PD) may cause SF6 decomposition, and the decomposed products of SF6, such as F atoms, play a dominant role in the breakdown of insulation systems. In this study, the PD caused by metal protrusion defects is simulated by a needle-plate electrode using pulsed high voltage in SF6/Ar mixtures. The spatial and temporal characteristics of SF6/Ar plasma are analyzed by measuring the emission spectra of F and Ar atoms, which are important for understanding the characteristics of PD. The spatial resolved results show that both F and Ar atom spectral intensities increase first from the plate anode to the needle and then decrease under the conditions of a background pressure of400 Pa, peak voltage of-1000 V, frequency of 2 kHz, pulse width of 60 μs, and electrode gap of 5-9 mm. However, the distribution characteristics of F and Ar are significantly different. The temporal distribution results show that the spectral intensity of Ar decreasesfirst and then increases slowly, while the spectral intensity of F increases slowly for the duration of the pulsed discharge at the electrode gap of 5 mm and the pulse width of40-80 μs.展开更多
HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics...HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.展开更多
The non-chain chemical HF(DF)laser is one of the most powerful electrically-driven lasers operating in mid-infrared,in which SF6-C2H6 mixtures are often used as lasering media.Due to the electronegativity of SF6,the d...The non-chain chemical HF(DF)laser is one of the most powerful electrically-driven lasers operating in mid-infrared,in which SF6-C2H6 mixtures are often used as lasering media.Due to the electronegativity of SF6,the discharge in SF6-C2H6 presents a complicated discharge mode.To achieve reproducible pulsed laser output,pulsed discharge in SF6-C2H6 mixtures is investigated for discharge mode using plane electrodes assisted by array pre-ionization spark pins in cathode surface.Firstly,two modes can be distinguished.One mode is called the selfsustained volume discharge(SSVD),which is characterized by spatial uniformity in the discharge gap and pulse to pulse repeatability.On the contrary,another mode includes random arc passages in the discharge gap and therefore cannot conduct lasering.By varying discharge conditions(gap voltage,gas pressure,etc)two discharge modes are observed.Secondly,the holding scope of the SSVD mode is analyzed for the optimal mixture ratio of 20:1,and the boundary tend of the holding scope of SSVD indicates there exists maximum gas pressure and maximum charging voltage for SSVD.Finally,the peak current of SSVD relates positively to charging voltage,while negatively to gas pressure,from which it is drawn that synchronous electron avalanches initiated by the sliding array overlap spatially into SSVD and thus SSVD is essentially an α ionization avalanche.展开更多
Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S...Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S>7, is quite broad to SO2 and the H2S concentration permission. Even if it reaches 100μL/L, it will not be in danger immediately to the safe operation of equipment. We may plan, arrange, and overhaul calmly. When obtaining the bare conductor overheating failure, it has not involved the resuming insulation. We may use the resuming insulation discharge failure criterion.展开更多
Surface coating technology is an effective way to solve the interface insulation problem of DC GIS/GIL basin insulators, but the performance of the coating will change greatly, and the insulation strength will be comp...Surface coating technology is an effective way to solve the interface insulation problem of DC GIS/GIL basin insulators, but the performance of the coating will change greatly, and the insulation strength will be completely lost, after long-term use in the extreme conditions of corona erosion. In this research, the multi-needle-plate electrode platform was constructed to explore the long-term use performance of Si C-doped nanocomposite exposed to corona discharge in SF6gas. Samples with a high Si C content have advantages in maintaining physical and chemical properties such as elemental composition, erosion depth, surface roughness and mass loss. The nanocomposite doped with 6 wt.% Si C has prominent surface insulation strength after long term exposure to corona, and the others are close to losing, or have completely lost,their insulating properties. Furthermore, the degradation mechanism of physicochemical properties of composite exposed to corona discharge was investigated with the proposed Reax FF MD model of energetic particles from SF6decomposition bombarding the epoxy surface. The reaction process of SF particles and F particles with the cross-linked epoxy resin, and the Si C nanoparticles providing shelter to the surrounding polymer and mitigating their suffering direct bombardment, have been established. The damage propagation depth, mass loss and surface roughness change of nanocomposite material bombarded by SF6decomposition products is reproduced in this simulation. Finally, the deterioration mechanism of insulation properties for the Si C-doped composite was elucidated with DFT analysis. The band gap of the molecule containing S drops directly from the initial 7.785 e V to 1.875 e V, which causes the deterioration of surface electric properties.展开更多
The characteristics of high pressure sulphur hexafluoride(SF6) discharges in a highly non-uniform electric field under repetitive nanosecond pulses are investigated in this paper.The influencing factors on discharge...The characteristics of high pressure sulphur hexafluoride(SF6) discharges in a highly non-uniform electric field under repetitive nanosecond pulses are investigated in this paper.The influencing factors on discharge process,such as gas pressure,pulse repetition frequency(PRF),and number of applied pulses,are analyzed.Experimental results show that the corona intensity weakens with the increase of gas pressure and strengthens with the increase of PRF or number of applied pulses.Spark discharge images suggest that a shorter and thicker discharge plasma channel will lead to a larger discharge current.The number of applied pulses to breakdown descends with the increase of PRF and ascends with the rise of gas pressure.The reduced electric field(E/p) decreases with the increase of PRF in all circumstances.The experimental results provide significant supplements to the dielectric characteristics of strongly electronegative gases under repetitive nanosecond pulses.展开更多
Experiments were carried out to ascertain multichannel discharge characteristics in a self-designed coaxial field-distortion gas switch filled with SFa-N2 or SF6-Ar gas mixtures of different mixing ratios. In these ex...Experiments were carried out to ascertain multichannel discharge characteristics in a self-designed coaxial field-distortion gas switch filled with SFa-N2 or SF6-Ar gas mixtures of different mixing ratios. In these experiments, the pressure varied from 0.1 MPa to 0.2 MPa, the voltage pulse peak applied to the switch was in the range from 40 kV to 78 kV, and the pulse rise time was 11 ns. The static breakdown strength of the gas switch gap in the switch was also measured. The results show that in general the average number of discharge channels for SF6-Ar or SF6-N2 gas mixture which contains less SFa is larger than that for gas mixture which contains more SF6, however, the average number of channels almost keeps constant as the gas mixing ratio varies when the pulse rise rate is high enough. The static breakdown strength of the gas switch gap decreases slightly as the content of argon or nitrogen increases.展开更多
An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insul...An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.展开更多
This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by ...This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge.展开更多
基金supported by National Natural Science Foundation of China (Nos. 11605023, 11805028, and 11705020)the National Key R&D Program of China (No. 2017YFE0301300)+1 种基金the China Postdoctoral Science Foundation (Nos. 2017T100172 and 2016M591423)the Fundamental Research Funds for the Central Universities (Nos. DUT17RC(4)53 and DUT18LK38)
文摘The study of sulfur hexafluoride(SF6) discharge is vital for its application in gas-insulated equipment. Direct current partial discharge(PD) may cause SF6 decomposition, and the decomposed products of SF6, such as F atoms, play a dominant role in the breakdown of insulation systems. In this study, the PD caused by metal protrusion defects is simulated by a needle-plate electrode using pulsed high voltage in SF6/Ar mixtures. The spatial and temporal characteristics of SF6/Ar plasma are analyzed by measuring the emission spectra of F and Ar atoms, which are important for understanding the characteristics of PD. The spatial resolved results show that both F and Ar atom spectral intensities increase first from the plate anode to the needle and then decrease under the conditions of a background pressure of400 Pa, peak voltage of-1000 V, frequency of 2 kHz, pulse width of 60 μs, and electrode gap of 5-9 mm. However, the distribution characteristics of F and Ar are significantly different. The temporal distribution results show that the spectral intensity of Ar decreasesfirst and then increases slowly, while the spectral intensity of F increases slowly for the duration of the pulsed discharge at the electrode gap of 5 mm and the pulse width of40-80 μs.
文摘HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.
基金National Natural Science Foundation of China(No.11375041).
文摘The non-chain chemical HF(DF)laser is one of the most powerful electrically-driven lasers operating in mid-infrared,in which SF6-C2H6 mixtures are often used as lasering media.Due to the electronegativity of SF6,the discharge in SF6-C2H6 presents a complicated discharge mode.To achieve reproducible pulsed laser output,pulsed discharge in SF6-C2H6 mixtures is investigated for discharge mode using plane electrodes assisted by array pre-ionization spark pins in cathode surface.Firstly,two modes can be distinguished.One mode is called the selfsustained volume discharge(SSVD),which is characterized by spatial uniformity in the discharge gap and pulse to pulse repeatability.On the contrary,another mode includes random arc passages in the discharge gap and therefore cannot conduct lasering.By varying discharge conditions(gap voltage,gas pressure,etc)two discharge modes are observed.Secondly,the holding scope of the SSVD mode is analyzed for the optimal mixture ratio of 20:1,and the boundary tend of the holding scope of SSVD indicates there exists maximum gas pressure and maximum charging voltage for SSVD.Finally,the peak current of SSVD relates positively to charging voltage,while negatively to gas pressure,from which it is drawn that synchronous electron avalanches initiated by the sliding array overlap spatially into SSVD and thus SSVD is essentially an α ionization avalanche.
文摘Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S>7, is quite broad to SO2 and the H2S concentration permission. Even if it reaches 100μL/L, it will not be in danger immediately to the safe operation of equipment. We may plan, arrange, and overhaul calmly. When obtaining the bare conductor overheating failure, it has not involved the resuming insulation. We may use the resuming insulation discharge failure criterion.
基金supported by National Natural Science Foundation of China(Nos.51737005,51929701,52177147 and 52127812)。
文摘Surface coating technology is an effective way to solve the interface insulation problem of DC GIS/GIL basin insulators, but the performance of the coating will change greatly, and the insulation strength will be completely lost, after long-term use in the extreme conditions of corona erosion. In this research, the multi-needle-plate electrode platform was constructed to explore the long-term use performance of Si C-doped nanocomposite exposed to corona discharge in SF6gas. Samples with a high Si C content have advantages in maintaining physical and chemical properties such as elemental composition, erosion depth, surface roughness and mass loss. The nanocomposite doped with 6 wt.% Si C has prominent surface insulation strength after long term exposure to corona, and the others are close to losing, or have completely lost,their insulating properties. Furthermore, the degradation mechanism of physicochemical properties of composite exposed to corona discharge was investigated with the proposed Reax FF MD model of energetic particles from SF6decomposition bombarding the epoxy surface. The reaction process of SF particles and F particles with the cross-linked epoxy resin, and the Si C nanoparticles providing shelter to the surrounding polymer and mitigating their suffering direct bombardment, have been established. The damage propagation depth, mass loss and surface roughness change of nanocomposite material bombarded by SF6decomposition products is reproduced in this simulation. Finally, the deterioration mechanism of insulation properties for the Si C-doped composite was elucidated with DFT analysis. The band gap of the molecule containing S drops directly from the initial 7.785 e V to 1.875 e V, which causes the deterioration of surface electric properties.
基金supported by the National Basic Research Program of China(973 Program)(No.2011CB209405)National Natural Science Foundation of China(No.51207154)the Opening Project of State Key Laboratory of Electrical Insulation and Power Equipment in Xi'an Jiaotong University of China(No.EIPE12204)
文摘The characteristics of high pressure sulphur hexafluoride(SF6) discharges in a highly non-uniform electric field under repetitive nanosecond pulses are investigated in this paper.The influencing factors on discharge process,such as gas pressure,pulse repetition frequency(PRF),and number of applied pulses,are analyzed.Experimental results show that the corona intensity weakens with the increase of gas pressure and strengthens with the increase of PRF or number of applied pulses.Spark discharge images suggest that a shorter and thicker discharge plasma channel will lead to a larger discharge current.The number of applied pulses to breakdown descends with the increase of PRF and ascends with the rise of gas pressure.The reduced electric field(E/p) decreases with the increase of PRF in all circumstances.The experimental results provide significant supplements to the dielectric characteristics of strongly electronegative gases under repetitive nanosecond pulses.
基金supported by National Natural Science Foundation of China(No.51177132)
文摘Experiments were carried out to ascertain multichannel discharge characteristics in a self-designed coaxial field-distortion gas switch filled with SFa-N2 or SF6-Ar gas mixtures of different mixing ratios. In these experiments, the pressure varied from 0.1 MPa to 0.2 MPa, the voltage pulse peak applied to the switch was in the range from 40 kV to 78 kV, and the pulse rise time was 11 ns. The static breakdown strength of the gas switch gap in the switch was also measured. The results show that in general the average number of discharge channels for SF6-Ar or SF6-N2 gas mixture which contains less SFa is larger than that for gas mixture which contains more SF6, however, the average number of channels almost keeps constant as the gas mixing ratio varies when the pulse rise rate is high enough. The static breakdown strength of the gas switch gap decreases slightly as the content of argon or nitrogen increases.
基金Manitoba Hydro for funding and supporting this research
文摘An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.
基金Supported by National Natural Science Foundation of China(50707023)
文摘This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge.