Traditionally the global management system of an organization is frequently split into a number of individual management systems that are defined and implemented according to specific management systems standards (MSS...Traditionally the global management system of an organization is frequently split into a number of individual management systems that are defined and implemented according to specific management systems standards (MSSs) as well as managed independently. The individual implementation of MSSs is an option that leads to several inefficiencies and sub-optimization of the global management system of an organization. As referred by ISO [1] the interested parties’ requirements increase. A more effective and efficient option for an organization is to integrate, into an integrated management system (IMS), the implementation and management of requirements of multiple MSSs. Certain difficulties are associated to the structuring process, implementation, verification, evaluation, improvement and progressive development of an IMS in the organizations. Several scholars have proposed various theoretical approaches regarding the integration of individual management systems (MSs) leading to the conclusion that there is not a common practice for all organizations as they encompass different characteristics. This paper aims to present and justify a designed methodology to be used by organizations to support the integration of various MSs. Among them are highlighted: the Environmental Management System (EMS) according ISO 14001 [2], the Quality Management System (QMS) according ISO 9001 [3], and the Occupational Health and Safety Management System (OH & SMS) according OHSAS 18001 [4]. The methodology was designed in the context of a Portuguese company, on sequence of an organizational diagnosis and a research that was performed through a questionnaire. The strategy and the research methods took into consideration the case study.展开更多
The current consumption method of Electric Power Industry is “electricity consumption first, paying for it later”. The trend of consumption method is Pre-order Electricity. If we adopt the Pre-order Electricity Syst...The current consumption method of Electric Power Industry is “electricity consumption first, paying for it later”. The trend of consumption method is Pre-order Electricity. If we adopt the Pre-order Electricity System, we need to replace Traditional Energy Meter with Prepayment Energy Meter. But this alteration is costly. And the alarm action of Prepayment Energy Meter are bells and alarm lamp, users can not receive alarm information timely. In this paper, we present the design of Multi-user Electric Power Management Device. The device uses TMS320F2812 as CPU, with peripheral devices such as mobile phone communication module MC55, so the device supports remote operation and sends alarm information via SMS, it also can communicate with the master station by GPRS. The device can be seamlessly integrated into the existing power system in order to read meter, achieve billing and Pre-order Electricity functions. In addition, the device has the Harmonic Measurement function, so it is a high cost-effective application.展开更多
The need of a fast and global communication service has increased the competition among mobile phone companies. Therefore, those companies started adapting new methods to satisfy the needs of their customers. The Info...The need of a fast and global communication service has increased the competition among mobile phone companies. Therefore, those companies started adapting new methods to satisfy the needs of their customers. The Information Technology system proposed in this work is believed to provide an effective trading and managing tool for mobile’s community in Jordan.展开更多
文摘Traditionally the global management system of an organization is frequently split into a number of individual management systems that are defined and implemented according to specific management systems standards (MSSs) as well as managed independently. The individual implementation of MSSs is an option that leads to several inefficiencies and sub-optimization of the global management system of an organization. As referred by ISO [1] the interested parties’ requirements increase. A more effective and efficient option for an organization is to integrate, into an integrated management system (IMS), the implementation and management of requirements of multiple MSSs. Certain difficulties are associated to the structuring process, implementation, verification, evaluation, improvement and progressive development of an IMS in the organizations. Several scholars have proposed various theoretical approaches regarding the integration of individual management systems (MSs) leading to the conclusion that there is not a common practice for all organizations as they encompass different characteristics. This paper aims to present and justify a designed methodology to be used by organizations to support the integration of various MSs. Among them are highlighted: the Environmental Management System (EMS) according ISO 14001 [2], the Quality Management System (QMS) according ISO 9001 [3], and the Occupational Health and Safety Management System (OH & SMS) according OHSAS 18001 [4]. The methodology was designed in the context of a Portuguese company, on sequence of an organizational diagnosis and a research that was performed through a questionnaire. The strategy and the research methods took into consideration the case study.
文摘The current consumption method of Electric Power Industry is “electricity consumption first, paying for it later”. The trend of consumption method is Pre-order Electricity. If we adopt the Pre-order Electricity System, we need to replace Traditional Energy Meter with Prepayment Energy Meter. But this alteration is costly. And the alarm action of Prepayment Energy Meter are bells and alarm lamp, users can not receive alarm information timely. In this paper, we present the design of Multi-user Electric Power Management Device. The device uses TMS320F2812 as CPU, with peripheral devices such as mobile phone communication module MC55, so the device supports remote operation and sends alarm information via SMS, it also can communicate with the master station by GPRS. The device can be seamlessly integrated into the existing power system in order to read meter, achieve billing and Pre-order Electricity functions. In addition, the device has the Harmonic Measurement function, so it is a high cost-effective application.
文摘The need of a fast and global communication service has increased the competition among mobile phone companies. Therefore, those companies started adapting new methods to satisfy the needs of their customers. The Information Technology system proposed in this work is believed to provide an effective trading and managing tool for mobile’s community in Jordan.