期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Application of TEM Based on HTS SQUID Magnetometer in Deep Geological Structure Exploration in the Baiyun Gold Deposit,NE China 被引量:3
1
作者 Junjie Wu Xiaodong Chen +6 位作者 Yi Yang Qingquan Zhi Xingchun Wang Jie Zhang Xiaohong Deng Yi Zhao Yue Huang 《Journal of Earth Science》 SCIE CAS CSCD 2021年第1期1-7,共7页
Exploration of deep mineralization,particularly where the mineralization of interest is covered by a conductive overburden,is still a challenge for the conventional transient electromagnetic(TEM)method,which measures ... Exploration of deep mineralization,particularly where the mineralization of interest is covered by a conductive overburden,is still a challenge for the conventional transient electromagnetic(TEM)method,which measures TEM response using induction coils as the sensor.However,sensors such as fluxgate and superconductive quantum interfere device(SQUID)magnetometers can measure the B-field directly,which can provide more reliable deep information for mineralization exploration.In this paper,we report on the research and development of our newly developed high-temperature su-perconductor(HTS)SQUID magnetometer,which is cooled by liquid nitrogen at 77 K,and its applica-tion in TEM measurement for deep exploration in a gold deposit in China.This improved SQUID magnetometer version has a good performance with noise(60 fT/√Hz),slew rate(0.8 mT/S),dynamic range(100 dB),sensitivity(6.25 mV/nT),and bandwidth(DC-20 kHz).To find deep and peripheral ore in the Baiyun gold deposit located in Liaoning Province,NE China,both the SQUID magnetometer and induction coil were used for TEM data acquisition.Results show that TEM can detect the distribution of local strata and the faults contained within them.Results also indicate that the SQUID magnetome-ter has superior response performance for response over geological targets with slower decay time when compared to the induction coil signals.The SQUID magnetometer is more sensitive at observing the induced-polarization effect which is closely related to the ore-controlling faults. 展开更多
关键词 TEM HTS squid magnetometer B-field deep exploration the Baiyun gold deposit
原文传递
Retrieval of original signals for superconducting quantum interference device operating in flux locked mode
2
作者 刘当婷 田野 +2 位作者 赵士平 任育峰 陈赓华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第4期421-424,共4页
We discuss a simple relation between the input and output signals of a superconducting quantum interference device magnetometer operating in flux locked mode in a cosine curve approximation. According to this relation... We discuss a simple relation between the input and output signals of a superconducting quantum interference device magnetometer operating in flux locked mode in a cosine curve approximation. According to this relation, an original fast input signal can be easily retrieved from its distorted output response. This technique can be used in some areas such as sensitive and fast detection of magnetic or metallic grains in medicine and food security checking. 展开更多
关键词 squid magnetometer signal retrieval
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部