This paper attempts to develop a scaling procedure to measure structural vibration caused simultaneously by wall pressure fluctuations and the thermal load of hypersonic flow by a wind tunnel test. However, simulating...This paper attempts to develop a scaling procedure to measure structural vibration caused simultaneously by wall pressure fluctuations and the thermal load of hypersonic flow by a wind tunnel test. However, simulating the effect of thermal load is difficult with a scaled model in a wind tunnel due to the nonlinear effect of thermal load on a structure. In this work, the temperature variation of a structure is proposed to indicate the nonlinear effect of the thermal load,which provides a means to simulate both the thermal load and wall pressure fluctuations of a hypersonic Turbulent Boundary Layer(TBL) in a wind tunnel test. To validate the scaling procedure,both numerical computations and measurements are performed in this work. Theoretical results show that the scaling procedure can also be adapted to the buckling temperature of a structure even though the scaling procedure is derived from a reference temperature below the critical temperature of the structure. For the measurement, wall pressure fluctuations and thermal environment are simulated by creating hypersonic flow in a wind tunnel. Some encouraging results demonstrate the effectiveness of the scaling procedure for assessing structural vibration generated by hypersonic flow. The scaling procedure developed in this study will provide theoretical support to develop a new measurement technology to evaluate vibration of aircraft due to hypersonic flow.展开更多
This paper presents a new method for measuring the cabin noise of a structure in a wind tunnel. A method for scaling the cabin sound was derived to obtain the cabin noise of a structure,and the derivation of the scali...This paper presents a new method for measuring the cabin noise of a structure in a wind tunnel. A method for scaling the cabin sound was derived to obtain the cabin noise of a structure,and the derivation of the scaling procedure was based on a theoretical hypothesis regarding the cabin noise prediction for a scaled model in a wind tunnel. A frequency offset was generated because of the error introduced by model manufacture and installation, and a proposed modal test method was used to eliminate the frequency offset. Both a full-scale structure and scaled structure were measured in the wind tunnel tests. The cabin noise of the full-scale model was compared with the results obtained using the scaling procedure based on the scaled model. The comparisons of the measurement results indicate that the scaling procedures developed in this paper are effective for vibro-acoustic predictions in wind tunnels. Moreover, background noise tended to affect the results of the cabin sound for the wind tunnel test, and thus background noise should be prevented through specific design efforts.展开更多
基金support of the Equipment Priority Research Field Foundation of China(No.6140246030216ZK01001)
文摘This paper attempts to develop a scaling procedure to measure structural vibration caused simultaneously by wall pressure fluctuations and the thermal load of hypersonic flow by a wind tunnel test. However, simulating the effect of thermal load is difficult with a scaled model in a wind tunnel due to the nonlinear effect of thermal load on a structure. In this work, the temperature variation of a structure is proposed to indicate the nonlinear effect of the thermal load,which provides a means to simulate both the thermal load and wall pressure fluctuations of a hypersonic Turbulent Boundary Layer(TBL) in a wind tunnel test. To validate the scaling procedure,both numerical computations and measurements are performed in this work. Theoretical results show that the scaling procedure can also be adapted to the buckling temperature of a structure even though the scaling procedure is derived from a reference temperature below the critical temperature of the structure. For the measurement, wall pressure fluctuations and thermal environment are simulated by creating hypersonic flow in a wind tunnel. Some encouraging results demonstrate the effectiveness of the scaling procedure for assessing structural vibration generated by hypersonic flow. The scaling procedure developed in this study will provide theoretical support to develop a new measurement technology to evaluate vibration of aircraft due to hypersonic flow.
文摘This paper presents a new method for measuring the cabin noise of a structure in a wind tunnel. A method for scaling the cabin sound was derived to obtain the cabin noise of a structure,and the derivation of the scaling procedure was based on a theoretical hypothesis regarding the cabin noise prediction for a scaled model in a wind tunnel. A frequency offset was generated because of the error introduced by model manufacture and installation, and a proposed modal test method was used to eliminate the frequency offset. Both a full-scale structure and scaled structure were measured in the wind tunnel tests. The cabin noise of the full-scale model was compared with the results obtained using the scaling procedure based on the scaled model. The comparisons of the measurement results indicate that the scaling procedures developed in this paper are effective for vibro-acoustic predictions in wind tunnels. Moreover, background noise tended to affect the results of the cabin sound for the wind tunnel test, and thus background noise should be prevented through specific design efforts.