期刊文献+
共找到75篇文章
< 1 2 4 >
每页显示 20 50 100
Evaluating pediatric ureteropelvic junction obstruction:Dynamic magnetic resonance urography vs renal scintigraphy 99mtechnetium mercaptoacetyltriglycine
1
作者 Yousuf Al-Shaqsi Matthieu Peycelon +4 位作者 Annabel Paye-Jaouen Elisabeth Carricaburu Anca Tanase Christine Grapin-Dagorno Alaa El-Ghoneimi 《World Journal of Radiology》 2024年第3期49-57,共9页
BACKGROUND Ureteropelvic junction obstruction(UPJO)is a common congenital urinary tract disorder in children.It can be diagnosed as early as in utero due to the presence of hydronephrosis or later in life due to sympt... BACKGROUND Ureteropelvic junction obstruction(UPJO)is a common congenital urinary tract disorder in children.It can be diagnosed as early as in utero due to the presence of hydronephrosis or later in life due to symptomatic occurrence.AIM To evaluate the discrepancy between dynamic contrast-enhanced magnetic resonance urography(dMRU)and scintigraphy 99m-technetium mercaptoacetyltriglycine(MAG-3)for the functional evaluation of UPJO.METHODS Between 2016 and 2020,126 patients with UPJO underwent surgery at Robert DebréHospital.Of these,83 received a prenatal diagnosis,and 43 were diagnosed during childhood.Four of the 126 patients underwent surgery based on the clinical situation and postnatal ultrasound findings without undergoing functional imaging evaluation.Split renal function was evaluated preoperatively using scintigraphy MAG-3(n=28),dMRU(n=53),or both(n=40).In this study,we included patients who underwent surgery for UPJO and scintigraphy MAG-3+dMRU but excluded those who underwent only scintigraphy MAG-3 or dMRU.The patients were divided into groups A(<10%discrepancy)and B(>10%discrepancy).We examined the discrepancy in split renal function between the two modalities and investigated the possible risk factors.RESULTS The split renal function between the two kidneys was compared in 40 patients(28 boys and 12 girls)using scintigraphy MAG-3 and dMRU.Differential renal function,as determined using both modalities,showed a difference of<10%in 31 children and>10%in 9 children.Calculation of the relative renal function using dMRU revealed an excellent correlation coefficient with renal scintigraphy MAG-3 for both kidneys.CONCLUSION Our findings demonstrated that dMRU is equivalent to scintigraphy MAG-3 for evaluating split renal function in patients with UPJO. 展开更多
关键词 Uteropelvic junction obstruction scintigraphy 99m-technetium mercaptoacetyltriglycine Magnetic resonance imaging Dynamic contrast-enhanced magnetic resonance urography
下载PDF
Contribution of Bone Scintigraphy in the Metastatic Extension Assessment of Prostate Cancer: A Study of 288 Cases in the Nuclear Medicine Department of Idrissa Pouye General Hospital, Dakar
2
作者 El Hadji Amadou Lamine Bathily Ousseynou Diop +7 位作者 Mamoudou Salif Djigo Gora Thiaw Kalidou Gueye Mohamed Chekhma Olatounde Herbert Fachinan Boucar Ndong Omar Ndoye Mamadou Mbodj 《Open Journal of Biophysics》 2024年第2期79-98,共20页
Introduction: Prostate cancer is the most frequently diagnosed male malignancy and the fifth leading cause of cancer death in men worldwide. Since the advent of screening methods such as Prostate Specific Antigen (PSA... Introduction: Prostate cancer is the most frequently diagnosed male malignancy and the fifth leading cause of cancer death in men worldwide. Since the advent of screening methods such as Prostate Specific Antigen (PSA) assay, digital rectal examination (DRE) and prostate biopsy, its incidence has increased significantly. The aim of our study was to analyse aspects of bone scintigraphy (BS) as part of the metastatic extension assessment of prostate cancer in Senegal. Patients and Methods: This was a retrospective descriptive and analytical study, running from January 1<sup>er</sup> 2022 to August 31 2023. Patients with histologically confirmed prostate cancer were included. Whole-body scans (WBS) were performed using a dual-head SPECT gamma camera (Mediso Nucline TM Spirit DH-V type), 3 hours after intravenous injection of 8 MBq/kg (555 to 740 MBq) of <sup>99m</sup>Tc-HMDP. Results: A total of 288 patients with a mean age of 68.37 ± 7.79 years were included. The median total PSA level was 97.6 ng/ml, with 144 patients having a level greater than or equal to 20 ng/ml. All patients had adenocarcinoma, and the Gleason score was available in 202 (70.13%) patients, 75.75% of whom had a score greater than or equal to 7. BS was contributory in 70.48% of cases, with 30.90% positive and 39.58% negative. The result was inconclusive in 85 patients (29.51%). The mean PSA for patients with a positive scan was 190.2 ng/ml and 40.6 ng/ml for those with a negative scan. Multiple metastatic lesions predominated (87.35% of cases). Metastatic lesions occurred preferentially in the axial skeleton, with a proportion of 68% versus 32% in the appendicular skeleton. Classification of bone metastases according to the SOLOWAY score revealed grade I (62.07%), grade II (35.63%) and grade IV (2.30%). Conclusion: In Senegal, prostate cancer is generally diagnosed in men of advanced age. The presence of bone metastases is frequent in its evolution, transforming a curable localized disease into a generalized disease with a compromised prognosis. Bone scintigraphy remains an essential part of the initial work-up and evaluation of response to treatment. 展开更多
关键词 Prostate Cancer Bone Metastasis Bone scintigraphy Senegal
下载PDF
Contribution of Bone Scintigraphy in the Diagnosis of a Case of SAPHO in the Nuclear Medicine Department of Idrissa Pouye General Hospital (Dakar, Senegal)
3
作者 El Hadji Amadou Lamine Bathily Kalidou Gueye +13 位作者 Serigne Moussa Badiane Mamoudou Salif Djigo Gora Thiaw Ousseynou Diop Olatounde Herbert Fachinan Papa Mady Sy Alfonse Rodrigue Djiboune Kokou Fofo Toussaint Adambounou Louis Augustin Diaga Diouf Boucar Ndong Gora Mbaye Omar Ndoye Mounibé Diarra Mamadou Mbodj 《Open Journal of Medical Imaging》 2024年第1期1-9,共9页
Introduction: The acronym SAPHO (Synovitis, Acne, Pustulosis, Hyperostosis and Osteitis) is a syndrome combining osteoarticular and cutaneous manifestations. It occurs mainly between the ages of 30 and 50. Sternocosto... Introduction: The acronym SAPHO (Synovitis, Acne, Pustulosis, Hyperostosis and Osteitis) is a syndrome combining osteoarticular and cutaneous manifestations. It occurs mainly between the ages of 30 and 50. Sternocostoclavicular hyperostosis is one of the main distinguishing features. We report a case of SAPHO in Dakar diagnosed by bone scintigraphy. Observation: 28-year-old Senegalese women presented with left shoulder pain and relative functional impotence for over 2 years. Examination revealed right sternoclavicular hyperostosis and left shoulder pain on palpation. Questioning revealed a history of acne and hyperostosis of the right first toe. Bone scintigraphy, performed after injection of 630 MBq of <sup>99m</sup>Tc-HMDP, revealed: hyperfixation of the bilateral (right++) manubrio-sternal and sternoclavicular junction, producing the classic bull’s horn image;hyperfixation of the left shoulder with an inflammatory appearance;hyperfixation of the sacroiliac joints suggestive of bilateral sacroiliitis;hyperfixation of the right first toe;two mandibular hyper fixations probably related to dental damage. This scintigraphic appearance in one was strongly suggestive of SAPHO syndrome. Conclusion: SAPHO syndrome, related to spondyloarthropathy, associates cutaneous and osteoarticular signs. It is characterized by frequent delays in diagnosis due to poor recognition. Soy is an invaluable diagnostic tool, enabling us to assess the extent of the disease and its evolution. 展开更多
关键词 SAPHO Bone scintigraphy Young Woman Senegalese
下载PDF
Place of Bone Scintigraphy in the Assessment of Extension and Follow-Up of Breast Cancer in Senegal: Study of 165 Cases in the Nuclear Medicine Department of Idrissa Pouye General Hospital (Dakar)
4
作者 El Hadji Amadou Lamine Bathily Mamoudou Salif Djigo +7 位作者 Djimby Ba Gora Thiaw Ousseynou Diop Kalidou Gueye Olatounde Herbert Fachinan Boucar Ndong Omar Ndoye Mamadou Mbodj 《Open Journal of Medical Imaging》 2024年第1期10-30,共21页
Introduction: Breast cancer is the most common cancer in women worldwide, accounting for an estimated 22% of all female cancers. It is the leading cause of cancer mortality in women, almost all of which is due to meta... Introduction: Breast cancer is the most common cancer in women worldwide, accounting for an estimated 22% of all female cancers. It is the leading cause of cancer mortality in women, almost all of which is due to metastases, with 73% of metastases occurring in the bone. In oncology, metastable technetium 99-labelled methylene bisphosphonate bone scintigraphy (BS) remains the standard examination for detecting and assessing the extent of bone metastases. The aim of this study was to assess the role of BS in the evaluation and follow-up of breast cancer in Senegal. Methodology: This was a retrospective study of breast cancer patients who underwent bone scintigraphy with <sup>99m</sup>Tc-HMDP in the nuclear medicine department of Idrissa Pouye General Hospital (IPGHO), from July 2009 to June 2022. Results: We enrolled 165 patients, mean age 46.79 years (27 - 87 years). BS was performed in 94.37% of cases for post-therapeutic monitoring and in 5.63% for pre-therapeutic assessment. Results were contributory in 131 patients (92.25%), of whom 72 cases (50.70%) were normal and 59 cases (41.55%) positive or presenting bone metastases;and non-contributory or doubtful in 11 cases (7.75%). Secondary bone locations were multiple in 57 cases (96.61%) and single or solitary in 2 cases (3.39%). The scintigraphic appearance of bone metastases was hyper-fixative in 58 cases (98.31%) and mixed in 1 case (1.69%). Bone lesions were quantified using the Soloway’s grading classification. Conclusion: BS with <sup>99m</sup>Tc-labelled bisphosphonates remains the examination of choice for skeletal exploration, in the detection and extension of bone metastases in breast cancer. Performance has been enhanced by the development of SPECT coupled with CT (SPECT-CT). 展开更多
关键词 Breast Cancer Bone scintigraphy 99mTc-HMDP Bone Metastases
下载PDF
Subclinical ankle joint tuberculous arthritis-The role of scintigraphy:A case series
5
作者 Raden Andri Primadhi Achmad Hussein Sundawa Kartamihardja 《World Journal of Orthopedics》 2023年第4期260-267,共8页
BACKGROUND Tuberculosis remains a complicated problem.A lack of awareness accompanied by difficulty in diagnosis hinders the management of tuberculosis.Delayed management,particularly in osteoarticular regions,results... BACKGROUND Tuberculosis remains a complicated problem.A lack of awareness accompanied by difficulty in diagnosis hinders the management of tuberculosis.Delayed management,particularly in osteoarticular regions,results in unnecessary procedures,including joint-sacrificing surgery.CASE SUMMARY Three cases of subclinical ankle joint tuberculosis without clear signs of tuberculosis were presented.The efficacy of technetium-99m-ethambutol scintigraphy in diagnosing early-stage tuberculous arthritis is reported.CONCLUSION The reports suggested that scintigraphy is recommended to diagnose subclinical tuberculous arthritis,especially in tuberculosis endemic regions. 展开更多
关键词 ANKLE Infectious arthritis ETHAMBUTOL scintigraphy Tuberculosis Case report
下载PDF
Contribution of Scintigraphy in the Assessment of Extension of Osteophilic Cancers in Senegal from 2018 to 2021
6
作者 Olatoundé Herbert Fachinan El Hadji Lamine Bathily +5 位作者 Mamadou Salif Djigo Gilles David Houndétoungan Djibrillou Moussa Issoufou Boucar Ndong Kuassi Marcellin Amoussou-Guénou Mamadou Mbodj 《Open Journal of Biophysics》 CAS 2023年第1期1-13,共13页
The aim of this study was to highlight the contribution of bone scintigraphy in the assessment of extension of osteophilic cancers in Senegal. This was a retrospective study, with a descriptive and analytical purpose,... The aim of this study was to highlight the contribution of bone scintigraphy in the assessment of extension of osteophilic cancers in Senegal. This was a retrospective study, with a descriptive and analytical purpose, carried out over a period of four (04) years between January 01, 2018 and December 31, 2021. It focused on the files of patients who underwent bone scintigraphy for extension assessment of an osteophilic cancer during the study period. According to the study, prostate cancer was by far the most representative primary cancer (86.9%). Scintigraphy contributed in 75% of cases (362 cases) with 35% positive scintigraphy and 40% negative scintigraphy. The result was doubtful in 25% of cases (120 cases). The metastatic lesions were located preferentially at the level of the axial skeleton and only one case was of an exclusive appendicular site. More than half of patients with metastases (70%) had a poor prognosis with the SOLOWAY score greater than or equal to II. With the improvement of the nuclear imaging technical platform in Senegal (performance of SPECT/CT examinations), doubtful cases in our sample could be better explored with the advantage of adequate patient care. 展开更多
关键词 Bone scintigraphy Osteophilic Cancers Bone Metastases
下载PDF
Comparative evaluation of intragastric bile acids and hepatobiliary scintigraphy in the diagnosis of duodenogastric reflux 被引量:12
7
作者 Teng-Fei Chen Praveen K Yadav +4 位作者 Rui-Jin Wu Wei-Hua Yu Chang-Qin Liu Hui Lin Zhan-Ju Liu 《World Journal of Gastroenterology》 SCIE CAS 2013年第14期2187-2196,共10页
AIM:To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux(DGR).METHODS:The study contained 99 patients with DGR and 70 heal... AIM:To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux(DGR).METHODS:The study contained 99 patients with DGR and 70 healthy volunteers who made up the control group.The diagnosis was based on the combination of several objective arguments:a long history of gastric symptoms(i.e.,nausea,epigastric pain,and/or bilious vomiting) poorly responsive to medical treatment,gastroesophageal reflux symptoms unresponsive to protonpump inhibitors,gastritis on upper gastrointestinal(GI) endoscopy and/or at histology,presence of a bilious gastric lake at > 1 upper GI endoscopy,pathologic 24-h intragastric bile monitoring with the Bilitec device.Gas-tric juice was aspirated in the GI endoscopy and total bile acid(TBA),total bilirubin(TBIL) and direct bilirubin(DBIL) were tested in the clinical laboratory.Continuous data of gastric juice were compared between each group using the independent-samples Mann-Whitney U-test and their relationship was analysed by Spearman's rank correlation test and Fisher's linear discriminant analysis.Histopathology of DGR patients and 23 patients with chronic atrophic gastritis was compared by clinical pathologists.Using the Independent-samples Mann-Whitney U-test,DGR index(DGRi) was calculated in 28 patients of DGR group and 19 persons of control group who were subjected to hepatobiliary scintigraphy.Receiver operating characteristic curve was made to determine the sensitivity and specificity of these two methods in the diagnosis of DGR.RESULTS:The group of patients with DGR showed a statistically higher prevalence of epigastric pain in comparison with control group.There was no significant difference between the histology of gastric mucosa with atrophic gastritis and duodenogastric reflux.The bile acid levels of DGR patients were significantly higher than the control values(Z:TBA:-8.916,DBIL:-3.914,TBIL:-6.197,all P < 0.001).Two of three in the DGR group have a significantly associated with each other(r:TBA/DBIL:0.362,TBA/TBIL:0.470,DBIL/TBIL:0.737,all P < 0.001).The Fisher's discriminant function is followed:Con:Y = 0.002TBA + 0.048DBIL + 0.032TBIL 0.986;Reflux:Y = 0.012TBA + 0.076DBIL + 0.089TBIL-2.614.Eighty-four point zero five percent of original grouped cases were correctly classified by this method.With respect to the DGR group,DGRi were higher than those in the control group with statistically significant differences(Z =-5.224,P < 0.001).Twenty eight patients(59.6%) were deemed to be duodenogastric reflux positive by endoscopy,as compared to 37 patients(78.7%) by hepatobiliary scintigraphy.CONCLUSION:The integrated use of intragastric bile acid examination and scintigraphy can greatly improve the sensitivity and specificity of the diagnosis of DGR. 展开更多
关键词 Duodenogastric REFLUX DIAGNOSIS Intragastric BILE ACIDS HEPATOBILIARY scintigraphy
下载PDF
Noninvasive imaging assessment of non-alcoholic fatty liver disease:focus on liver scintigraphy 被引量:5
8
作者 Cristiane Valle Tovo Angelo Zambam de Mattos +3 位作者 Gabriela Perdomo Coral Fernanda Schild Branco Eiji Suwa Angelo Alves de Mattos 《World Journal of Gastroenterology》 SCIE CAS 2015年第15期4432-4439,共8页
Noninvasive diagnoses of nonalcoholic fatty-liver disease(NAFLD) involve the use of serologic markers and imaging methods, such as conventional ultrasonography(US),computed tomography, and magnetic resonance imaging. ... Noninvasive diagnoses of nonalcoholic fatty-liver disease(NAFLD) involve the use of serologic markers and imaging methods, such as conventional ultrasonography(US),computed tomography, and magnetic resonance imaging. Although these methods are reliable for the noninvasive detection of moderate to severe fatty changes in the liver, they are not reliable for detecting nonalcoholic steatohepatitis(NASH) and fibrosis. New imaging technologies, such as US-based transient elastography, acoustic radiation force impulse and magnetic resonancebased elastography, can reportedly be used to determine the severity of liver fibrosis associated with NASH. In this context, the field of nuclear medicine through liver scintigraphy has recently been proposed, and is being explored for use in the diagnosis of NASH. More importantly, nuclear medicine may contribute to the distinction between simple steatosis and NASH. For example, the enhanced release of cytokines and the decrease in the phagocytic activity of Kupffer cells play important roles in the pathogenesis of NASH. Removal of technetium-99 m colloid from circulation by Kupffer cell phagocytosis therefore provides a valuable imaging technique. Thus, nuclear medicine is poised to provide useful tools for the evaluation of patients with NAFLD. However, the evidence is still scarce, and more studies with larger samples are needed to identify their role before they are used in clinical practice. 展开更多
关键词 LIVER FIBROSIS LIVER scintigraphy Nonalcoholicfatty-liver disease diagnosis NONALCOHOLIC STEATOHEPATITIS NONINVASIVE methods
下载PDF
Comparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux 被引量:2
9
作者 Nuray Uslu Kizilkan Murat Fani Bozkurt +4 位作者 Inci Nur Saltik Temizel Hülya Demir Aysel Yüce Biray Caner Hasan Ozen 《World Journal of Gastroenterology》 SCIE CAS 2016年第43期9595-9603,共9页
AIM To evaluate the agreement of multichannel intraluminal impedance-p H monitoring(MII-p HM) and gastroesophageal reflux scintigraphy(GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five co... AIM To evaluate the agreement of multichannel intraluminal impedance-p H monitoring(MII-p HM) and gastroesophageal reflux scintigraphy(GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspectedgastroesophageal reflux disease(GERD) underwent 24-h combined MII-p HM recording and one hour radionuclide scintigraphy during the course of the MIIpH M study. Catheters with 6 impedance channels and 1 p H sensor were placed transnasally. Impedance and p H data analysis were performed automatically and manually. For impedance monitoring, reflux was defined as a retrograde 50% drop in impedance, starting distally and propagating retrogradely to at least the next two more proximal measuring channels. Reflux index(RI, percentage of the entire record that esophageal p H is < 4.0) greater than 4.2% for p HM and number of refluxes more than 50 for 24 h for MII were accepted as positive test results. At scintigraphy, 240 frames of 15 seconds duration were acquired in the supine position. Gastroesophageal reflux was defined as at least one reflux episode in the esophagus. After scintigraphic evaluation, impedance-pH recordings and scintigraphic images were evaluated together and agreement between tests were evaluated with Cohen's kappa.RESULTS Sufficient data was obtained from 60(80%) patients(34 male, 56.7%) with a mean age of 8.7 ± 3.7 years(range: 2.5-17.3 years; median: 8.5 years). Chronic cough, nausea, regurgitation and vomiting were the most frequent symptoms. The mean time for recording of MII-pH M was 22.8 ± 2.4 h(range: 16-30 h; median: 22.7 h). At least one test was positive in 57(95%) patients. According to diagnostic criteria, GERD was diagnosed in 34(57.7%), 44(73.3%), 47(78.3%) and 51(85%) patients by means of p HM, MII, GES and MII-p HM, respectively. The observed percentage agreements/κ values for GES and p HM, GES and MII, GES and MII-p HM, and MII and p HM are 48.3%/-0.118; 61.7%/-0.042; 73.3%/0.116 and 60%/0.147, respectively. There was no or slight agreement between GES and p HM alone, MII alone or MII-p HM. p H monitoring alone missed 17 patients compared to combined MII-p HM. The addition of MII to pH monitoring increased the diagnosis rate by 50%.CONCLUSION No or slight agreement was found among p H monitoring, MII monitoring, MII-pH monitoring and GES for the diagnosis of gastroesophageal reflux disease. 展开更多
关键词 Gastroesophageal 倒流疾病 孩子 多信道的 intraluminal 阻抗 监视的食道的 pH scintigraphy
下载PDF
Somatostatin receptor scintigraphy in the follow up of neuroendocrine neoplasms of appendix 被引量:1
10
作者 Jelena Saponjski Djuro Macut +4 位作者 Dragana Sobic-Saranovic Sanja Ognjanovic Ivana Bozic Antic Djordje Pavlovic Vera Artiko 《World Journal of Clinical Cases》 SCIE 2020年第17期3697-3707,共11页
BACKGROUND Neuroendocrine tumors of appendix(ANETs)known as carcinoids,are rare endocrine neoplasms originated from enterochromaffin cells of gastrointestinal tract.ANETs are the third most frequent(16.7%)gastrointest... BACKGROUND Neuroendocrine tumors of appendix(ANETs)known as carcinoids,are rare endocrine neoplasms originated from enterochromaffin cells of gastrointestinal tract.ANETs are the third most frequent(16.7%)gastrointestinal neuroendocrine tumors,with the incidence of 0.08-0.2 cases/100000 during one year.Incidental ANETs occur in 0.2%-0.7%of emergency surgical resections because of suspected appendicitis which is usually the first manifestation of ANET.Although there are a lot of papers about application of somatostatin receptor scintigraphy in gastrointestinal neuroendocrine tumors,there are very rare sporadic cases described about ANETs particularly.AIM To establish the role of somatostatin receptor scintigraphy(SRS)in the management of patients with neuroendocrine tumors of appendix(ANET).METHODS The total of 35 patients was investigated,23 females and 12 males,average age(43.7±17.3 years).All patients had histological diagnosis of ANET(34 carcinoids of appendix and one tubular carcinoid).Majority of tumors have been found incidentally during surgery of:Acute appendicitis(n=15),perforated appendicitis(n=2),ileus(n=3),hysterectomy(n=3),ruptured ovarian cyst(n=2),caecal volvulus(n=1),while 9 patients had diagnosis of appendiceal tumor before the surgery.Seventeen patients had tumor grade(G)G1,12 G2 and 6 G3.The right hemicolectomy was performed in 13,while the rest of the patients had appendectomy only.SRS was done early(2 h)and late(24 h)after i.v.application of 740 MBq technetium-99 m ethylenediamine-N,N’-diacetic acid Hydrazinonicotinyl-Tyr3-Octreotide(technetium-99 m-Tektrotyd,Polatom,Poland).SRS was performed for restaging in all the patients after surgery.RESULTS There were 12 true positive(TP),19 true negative,3 false positive and 1 false negative SRS result.Sensitivity of the method was 92.31%,specificity was 86.36%,positive predictive value was 80.00%,negative predictive value was 95.00%and accuracy 88.57%.Receiver operating characteristics analysis showed that SRS scintigraphy is a good test for detection TP cases[area under the curve of 0.850,95%confidence interval(CI):0.710-0.990,P<001].Single photon emission computed tomography contributed diagnosis in 7 TP findings.In 10 patients Krenning score was 4 and in 2 was 3.In 8 patients SRS significantly changed the management of the patients(in two surgery was repeated,in 4 somatostatin analogues and in two peptide receptor radionuclide therapy).Median progression-free survival in SRS positive patients was 52 months(95%CI:39.7-117.3 mo)while in SRS negative patients it was 60 months(95%CI:42.8-77.1 mo),without statistically significant difference between the two groups(P=0.434).CONCLUSION In conclusion,our results confirmed the value of SRS in the follow-up of the patients with ANET after surgery,if recurrences or metastases are suspected. 展开更多
关键词 Somatostatin receptor scintigraphy CARCINOID APPENDIX Follow up Nuclear medicine RADIONUCLIDE
下载PDF
A Correlation Study of the Effectiveness of Renal Scintigraphy and Sonography in the Detection and Evaluation of Renal Disorders 被引量:1
11
作者 Maithaa H. Alsubhi Atheer A. Alghanmi +2 位作者 Yara H. Alzabidi Alhanouf K. Bafail Saeed M. Bafaraj 《Journal of Biosciences and Medicines》 2022年第6期56-65,共10页
Purpose: To evaluate the amalgamation of scintigraphy and sonography techniques in prognosticating renal disease. Methods: All the patients were subjected to renal scintigraphy while 68 patients underwent renal ultras... Purpose: To evaluate the amalgamation of scintigraphy and sonography techniques in prognosticating renal disease. Methods: All the patients were subjected to renal scintigraphy while 68 patients underwent renal ultrasonography. Ninety-six patients’ imaging data was statistically analyzed including 43 females and 53 males. Renal U/S reported anatomical renal anomaly in 94.1% of patients versus 85.4% detected by scintigraphy. There were 41 patients out of 68 diagnosed with hydronephrosis and 21 of them were suffering from mild hydronephrosis as suggested by U/S imaging. The data were statistically analyzed using SPSS 21 software. Results: Renal scintigraphy of 41 hydronephrotic patients validated that 19 patients had non-obstructive bilateral pelvic dilation while the remaining 22 with mild to severe obstruction. Ultrasonography diagnosed 4 patients with renal obstruction. Conversely, renal scintigraphy validated 2 of them with renal obstruction based on renal function. Conclusions: Renal scintigraphy is not significant in diagnosing kidney disease;rather this is a vibrant imaging tool providing supplementary data based on renal function. An effectively targeted intervention regime can be achieved by correlating renal scintigraphy and renal ultrasonography results to minimize renal disease incidence. 展开更多
关键词 Renal Disorders Renal scintigraphy SONOGRAPHY
下载PDF
Superiority of Digital Subtraction for Analysis of Simultaneously-Acquired Dual-Radiopharmaceutical Parathyroid Scintigraphy 被引量:1
12
作者 Matthieu Pelletier-Galarneau Oyebola O. Sogbein +1 位作者 Laurent Dinh Lionel S. Zuckier 《Open Journal of Medical Imaging》 2015年第2期42-48,共7页
With dual-radiopharmaceutical (DR) parathyroid scintigraphy, imaging with 99mTcO4-or 123I-NaI is combined with 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas. The set images are then either visu... With dual-radiopharmaceutical (DR) parathyroid scintigraphy, imaging with 99mTcO4-or 123I-NaI is combined with 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas. The set images are then either visually compared or digitally subtracted to aid in interpretation. While both EANM and SNMMI guidelines recommend use of digital subtraction over visual interpretation alone, to date, the few formal comparisons performed have not demonstrated superiority. The purpose of this investigation is to rigorously assess the added value of digital subtraction over visual interpretation alone using simultaneously-acquired 123I-NaI and 99mTc-sestamibi images. Materials: 90 consecutive patients with DR parathyroid scintigraphy for primary hyperparathyroidism who underwent successful parathyroidectomy were included. DR planar acquisition was performed 15 minutes post injection using 10% dual energy windows. Digital subtraction was subsequently performed using commercially available software. Images were independently reviewed by 3 nuclear medicine trainees and 2 experienced nuclear medicine physicians with and without digital subtraction. Results were compared with surgical and histopathologic findings, which served as ground truth. Results: 90 patients had a total of 91 confirmed parathyroid lesions. All 5 readers had significantly greater sensitivity with digital subtraction compared with visual interpretation alone while specificity was not significantly diminished. Area under the ROC curve was significantly greater with digital subtraction in 3 of 5 readers. Agreement was greater among trainees and experienced physicians when using digital subtraction. Conclusion: Using an optimized DR planar co-imaging technique, digital subtraction significantly improved inter-observer agreement and confidence of interpretation and increased sensitivity, without diminishing specificity. 展开更多
关键词 PARATHYROID scintigraphy Dual-Isotope Dual-Radiopharmaceutical Digital SUBTRACTION Visual
下载PDF
Sensitivity of Esophageal Scintigraphy (Milk Scans) in Detecting Gastro-Esophageal Reflux 被引量:1
13
作者 Saeed Bafaraj Awad Alzahrani 《Open Journal of Medical Imaging》 2015年第1期1-9,共9页
Gastro-esophageal scintigraphy (milk scan) is an accurate technique for detecting gastro-esophageal reflux that can be performed rapidly with minimal patient discomfort. A retrospective study was performed to find out... Gastro-esophageal scintigraphy (milk scan) is an accurate technique for detecting gastro-esophageal reflux that can be performed rapidly with minimal patient discomfort. A retrospective study was performed to find out to how much radionuclide milk scan is sensitive for detecting gastro-esophageal reflux (GER) for 89 patients who subjected to milk scan within Years 2010 to 2013. The study group age is ranging from one month old to four years old. Milk scan was performed using PHILIPS and SEIMENS machine. Tc 99-m sulfur colloid with milk administrated orally or through nasogastric tube to the patient. The highest frequency for milk scan study was in age group of 0 - 6 months old with 77% positive finding. Patients who suffer repeated vomiting represented the highest reason of examination for milk scan (46% of overall cases), while chocking attacks, pulmonary aspiration, and congenital heart disease, were 26%, 16%, 12% respectively of the overall cases. Seventy-nine percent of patients who prepared to be examine using nasogastric tube found with positive finding, 50% of GER patients have abnormal tracer activity in the mid of esophagus;on the other hand, 50% of GER patients divided equally between the lower and upper esophagus. The study show that infants especially in age of 0 - 6 months old and with repeated vomiting symptoms are strongly recommended to milk scan study rather than fluoroscopy to avoid unnecessary dose to the patients. 展开更多
关键词 Gastro-Esophageal scintigraphy MILK SCAN Gastro-Esophageal REFLUX
下载PDF
Contribution of Bone Scintigraphy in the Diagnosis of a Calcaneus Fatigue Fracture in a Case at the Nuclear Medicine Department of Idrissa Pouye General Hospital (HOGIP) in Dakar 被引量:1
14
作者 El-Hadji Amadou Lamine Bathily B. Ndong +12 位作者 O. Diop M. S. Djigo K. Gueye A. Kokou G. Thiaw G. Mbaye L. A. D. Diouf M. Soumboundou A. R. Djiboune P. M. Sy O. Ndoye M. Diarra M. Mbodj 《Open Journal of Medical Imaging》 2020年第1期62-71,共10页
Introduction: Fatigue fractures are secondary to excessive, unusual, repeated mechanical stress, occurring on healthy bone. Bone scintigraphy (BS) with 99mTc-HMDP is an excellent means of diagnosis. We report a case o... Introduction: Fatigue fractures are secondary to excessive, unusual, repeated mechanical stress, occurring on healthy bone. Bone scintigraphy (BS) with 99mTc-HMDP is an excellent means of diagnosis. We report a case of stress fracture of the calcaneus with scintigraphic diagnosis, in a marathon runner. Patient and Methods: He is a 40-year-old athlete in overtraining with right calcaneal pain on running, intense at first, moderate in the middle and then persistent after exercise. The interrogation found no trauma to the right foot and the x-ray of the foot was without abnormality. The so 3 phases were performed following an injection of 564 MBq of 99mTc-HMDP, with a SPECT gamma camera. Results: Bone scintigraphy found in the early phase, hyper-perfusion and hyper-fixation of the right calcaneal region compared to its left counterpart and in the bone phase persistence of focal hyperfixation opposite the right calcaneus. This scintigraphic aspect of the right calcaneus in an overtrained marathon runner, in a painful context and in front of a normal X-ray, made us evoke a fracture of fatigue. A complementary CT scan performed two days after the BS was without abnormality. Conclusion: Fatigue fractures are micro-fractures generally not noticed on radiography and CT. BS due to its high sensitivity is an excellent or the best tool for the early diagnosis of stress fractures. 展开更多
关键词 Fatigue Fracture Bone scintigraphy SPORTS
下载PDF
How reliable is the lacrimal scintigraphy report? An interobserver agreement and reliability study
15
作者 Mohsen Bahmani Kashkouli Navid Abolfathzadeh +4 位作者 Parya Abdolalizadeh Nasser Karimi Raheleh Hedayati Samira Jafari Amirpooya Alemzadeh 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第3期401-406,共6页
AIM: To assess the inter-observer agreement and reliability as well as intra-observer repeatability for lacrimal scintigraphy(LS) reports with and without considering the irrigation test results.METHODS: A prospective... AIM: To assess the inter-observer agreement and reliability as well as intra-observer repeatability for lacrimal scintigraphy(LS) reports with and without considering the irrigation test results.METHODS: A prospective, observational, cross sectional study. Two masked clinicians(lacrimal surgeon and nuclear medicine specialist) independently reported 100 LS images(50 patients of >6 years of age with unilateral anophthalmic socket) in a university hospital. The lacrimal surgeon performed a diagnostic irrigation test and repeated the report of the same LS images 2 y after the first report(intra-observer agreement). A weighted Kappa analysis was performed to determine inter-observer agreement and reliability as well as intra-observer repeatability for the type(normal, partial and complete obstruction) and location(presac, preduct, and intraduct) of the obstruction. Subgroup analysis was also performed with consideration of irrigation test results. RESULTS: A significantly moderate agreement was found between lacrimal surgeon and nuclear medicine specialist for both the type(Kappa=0.55) and location(Kappa=0.48) of obstruction. Agreement values were higher for the type(Kappa=0.61 vs 0.41) and location(Kappa=0.56 vs 0.31) of obstruction in cases with normal than abnormal irrigation test. Strong and significant intraobserver(lacrimal surgeon) repeatability was found for both the type(Kappa=0.66) and location(Kappa=0.69) of obstruction. LS showed no to slight reliability based on irrigation test.CONCLUSION: A moderate agreement is found between lacrimal surgeon and nuclear medicine specialist regarding the interpretation of LS suggesting the importance ofconsensus groups among nuclear medicine specialists and lacrimal surgeons to create a common language for interpretation of LS. Intra-observer repeatability is strong for the lacrimal surgeon. 展开更多
关键词 EPIPHORA LACRIMAL drainage LACRIMAL scintigraphy RELIABILITY AGREEMENT
下载PDF
LIVER SCINTIGRAPHY AND ULTRASONOGRAPHY FOR THE DIAGNOSIS OF FOCAL AND DIFFUSE DISEASES
16
作者 朱国泓 石健民 +5 位作者 藏小红 颜珏 赵宝经 赵小华 马步成 王刚 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第1期1-7,共7页
The scintiphotos and ultrasonophotos of 186 patients with focal and diffuse diseases of liver were collected and analysed. All the data were get from the in-patients of China-Japan Friendship Hospital. The Sigma 438 t... The scintiphotos and ultrasonophotos of 186 patients with focal and diffuse diseases of liver were collected and analysed. All the data were get from the in-patients of China-Japan Friendship Hospital. The Sigma 438 typedγ camera (USA) was used. Fifteen min after 99mTc-phytate were injected i.v., If any defect region was found, it was recorded as a SOL; the SSA 90A, SAL 77A and SAL 50A US scanners (Japan) were used, if any abnormal echo pattern was found, it was a SOL. Of 134 patients have done both examinations during 7 days, 122 patients had coincident results occupied 91.0%. For detection of SOL, the sensitivity of scintigraphy is 94.1%, specificity is 94.2%, accuracy is 94.8%; the sensitivity of US is 100%, specificity is 89.7%, the accuracy is 95.6%. The hepatic blood flow and blood pool study showed that 104 from 115 patients were coincident (90.4%). The spleen and liver accumulation ratio determination showed that 51 from 64 subjects were coincident (80.0%). The characteristic features of scintigraphy and US graphy were described in hepatoma, hemangioma, cyst abscess and cirrhosis. The advantages of these examinations were discussed and concluded that their procedures are valuable and widely available. 展开更多
关键词 scintigraphy ULTRASONOGRAPHY LIVER disease
下载PDF
Primary hepatic neuroendocrine neoplasm diagnosed by somatostatin receptor scintigraphy:A case report
17
作者 Miho Akabane Yuta Kobayashi +3 位作者 Keiichi Kinowaki Satoshi Okubo Junichi Shindoh Masaji Hashimoto 《World Journal of Clinical Cases》 SCIE 2022年第7期2222-2228,共7页
BACKGROUND Primary hepatic neuroendocrine neoplasm(NEN)is a rare condition,and it is difficult to differentiate between primary and metastatic hepatic NENs.Herein,we report a case of primary hepatic NEN that initially... BACKGROUND Primary hepatic neuroendocrine neoplasm(NEN)is a rare condition,and it is difficult to differentiate between primary and metastatic hepatic NENs.Herein,we report a case of primary hepatic NEN that initially mimicked a hemangioma but showed a gradual increase in size on long-term careful observation.CASE SUMMARY A 47-year-old woman was incidentally diagnosed with a 12-mm liver mass,suspected to be a hemangioma.Since then,regular follow-up had been carried out.Ten years later,she was referred to our institute due to the tumor(located in segment 4)having increased to 20 mm.Several imaging studies depicted no apparent extrahepatic lesion.Positron emission tomography(PET)/computed tomography exhibited significant accumulation in the mass lesion,which made us consider the possibility of malignancy.Left hepatectomy was performed.The histopathological diagnosis was neuroendocrine tumor grade 2,with somatostatin receptor 2 a/5 positivity.Postoperative somatostatin receptor scintigraphy(SRS)showed no other site,leading to the diagnosis of NEN of primary hepatic origin.The gradual growth of the hepatic NEN over 10 years suggested that it was likely to be a primary liver tumor.CONCLUSION In this case,positivity on PET and postoperative SRS may have helped determine whether the tumor was primary or metastatic. 展开更多
关键词 Hepatic neoplasm scintigraphy SURGERY Positron-emission tomography Clinical decision-making Case report
下载PDF
Dynamic Renal Scintigraphy in Diagnosis of Upper Urinary Tract Obstruction in Transplanted Kidney
18
作者 鲜于志群 吴华 +2 位作者 周健 周平 赵明 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第2期156-158,共3页
Nuclide renal dynamic imaging was performed on 88 transplanted kidney. Two kinds of renal scintigraphic characteristics were identified in recipients with supravesical obstruction of the graft. First, the regular type... Nuclide renal dynamic imaging was performed on 88 transplanted kidney. Two kinds of renal scintigraphic characteristics were identified in recipients with supravesical obstruction of the graft. First, the regular type was characterized by radioactivity defect area in kidney parenchyma during early uptake period followed by ureteropelvic retention. Second, the tubular type was typified by cortical retention and attenuation in collecting system during the whole test period with a special sign of “hollow kidney”. Non obstructive dilated calyces showed similar signs as the regular type. Acute rejection reaction and tubule necrosis demonstrated obstructive time activity curves. However, the radioactivity retention appeared in cortex. It was suggested that dilated calyces and obstructive renogram might not be reliable evidence for upper urinary tract obstruction. The signs of radioactivity attenuation in kidney parenchyma during early uptake period followed by ureteropelvic retention may be more valuable for the evaluation. As for tubular obstruction, specified “hollow kidney” was the characteristic sign which is helpful for the diagnosis. 展开更多
关键词 transplanted kidney upper urinary tract obstruction renal scintigraphy 99m Tc DTPA
下载PDF
Effectiveness of Cardiac Scintigraphy and Standard Eco-Cardiograph in the Detection and Evaluation of Cardiac Disorders, Including Ischemic Heart Diseases
19
作者 Saeed M. Bafaraj 《Journal of Biosciences and Medicines》 2021年第4期90-109,共20页
<strong>Background: </strong>Cardiac disorders are the leading causes of morbidity and mortality globally. <strong>Aim: </strong>The current study aimed to compare the effectiveness of echocard... <strong>Background: </strong>Cardiac disorders are the leading causes of morbidity and mortality globally. <strong>Aim: </strong>The current study aimed to compare the effectiveness of echocardiographic and scintigraphy investigation in cardiovascular disorders detection and evaluation, including ischemic heart disease (IHD) diagnosis at King Abdulaziz University in Saudi Arabia. <strong>Methods: </strong>157 patients (male/ female: 68%/32%;mean age 64 ± 0.83 years) were included in the report in the current study. All subjects underwent gated myocardial perfusion scintigraphy and standard Echocardiography.<strong> Results: </strong>About 84% of cases were diagnosed with any types of cardiac disorders by Echocardiography, whereas through scintigraphy, 61% of patients were detected cardiac disorders. The age stratification did not impact the prevalence of cardiac disorders detected by them. Scintigraphy showed a higher detection rate (59%), while only 29% of cases were detected with IHD by eco-cardiograph. <strong>Conclusions:</strong> In conclusion, both techniques, namely standard Echocardiography, and myocardial scintigraphy, are useful in the evaluation and detection of cardiac disorders in patients having any type of cardiac problems. Both investigations showed a differential pattern in cardiac disorders diagnosis with a particular focus on IHD. Gender differences and age stratification also contributed to this differential pattern of diagnosis. <strong>Trial Registration:</strong> The research doesn’t include experiments in humans or animals. It is a retrospective study for data record review as an observational study, so no trial registration is required. 展开更多
关键词 Cardiac Disorders EVALUATION Comparison Standard Echocardiography Cardiac scintigraphy
下载PDF
Incidental Diagnosis of a Brown Tumor Mimicking Bone and Lung Metastasis during a Parathyroid Scintigraphy
20
作者 Fabrice Fokoué Sanae El Mselmi +1 位作者 Nadia Abaouz Nadia Ismaili Alaoui 《Advances in Molecular Imaging》 2020年第2期7-13,共7页
We report herein a case of a 40-year-old male patient with chronic renal failure presenting a severe hyperparathyroidism with an elevation of parathormone level evaluated in nuclear medicine department for MIBI-Techne... We report herein a case of a 40-year-old male patient with chronic renal failure presenting a severe hyperparathyroidism with an elevation of parathormone level evaluated in nuclear medicine department for MIBI-Technetium-99m parathyroid scintigraphy. The parathyroid scintigraphy revealed the appearance of a preferential fixation of the MIBI-99mTc opposite the lower left pole of the thyroid and opposite the upper part of the right hemi thorax. A subsequent single-photon emission computed tomography-computed tomography focused on the cervico-thoracic region was performed and showed an ectopic parathyroid adenoma associated with an incidental brown tumor mimicking bone and lung metastases. Our case report confirms the usefulness of additional hybrid SPECT-CT imaging in the management of hyperparathyroidism. 展开更多
关键词 HYPERPARATHYROIDISM Thyroid scintigraphy PARATHYROID scintigraphy Technetium-99m MIBI-Technetium-99m SPECT/CT ECTOPIC PARATHYROID Adenoma Brown Tumor
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部