As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main me...As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.展开更多
Two measurement systems, one being comprised of three HPGe detectors and the other being a 4π measurement system of the assembly of 10 sets of scintillation detectors, were compared for their measurement performance ...Two measurement systems, one being comprised of three HPGe detectors and the other being a 4π measurement system of the assembly of 10 sets of scintillation detectors, were compared for their measurement performance in operations of radioactive waste drum radioactivity measurement and clearance and release operation of decommissioning. The system features of the former were high costs, capable of identifying radionuclides, a measurement time of about 1000 sec. The system features of the latter were high sensibility, capable of identifying hotspots, a measurement time of about 100 sec. Various comparisons were made for the differences of the two systems on reference drums, whole-drum homogeneous and non-homogeneous metal drums and non-metal drums, whole-drums of different filling rates. The aim was to compare the differences of the two measurement systems in measuring radioactivity of critical radionuclides of <sup>137</sup>Cs, <sup>54</sup>Mn and <sup>60</sup>Co.展开更多
The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network wi...The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network without biases and hidden layers is adopted. A set of monoenergetic detector response functions in the energy range from 0.25 MeV to 16 MeV with an energy interval of 0.25 MeV are generated by the Monte Carlo code O5S in the training phase of the unfolding process. The capability of ANN was demonstrated successfully using the Monte Carlo data itself and experimental data obtained from the Am-Be neutron source and D-T neutron source.展开更多
Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-g...Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-ground experiments, the flux of neutron background is so low that large-scale detection is usually necessary. In this paper, by using Geant4, the relationship between detection efficiency and volume is investigated, meanwhile, two geometrical schemes for this detection including a single large-sized detector and arrayed multi-detector are compared under the condition of the same volume. The geometrical parameters of detectors are filtrated and detection efficiencies obtained under the similar background condition of China Jingping Underground Laboratory (CJPL). The results show that for a large-scale Gd-doped liquid scintillation detector, the detection efficiency increases with the size of detector at the beginning and then trends toward a constant. Under the condition of the same length and cross section, the arrayed multi-detector has almost similar detection performance as the single large-sized detector, while too much detector number could cause degeneration of detection performance. Considering engineering factors, such as testing, assembling and production, the 4 × 4 arrayed detector scheme is flexible and more suitable. Furthermore, the conditions for using fast and slow signal coincidence detection and the detectable lower limit of neutron energy are evaluated by simulating the light process.展开更多
A 760 mm × 760 mm× 30 mm plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and γrays. A position...A 760 mm × 760 mm× 30 mm plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and γrays. A position- independent effective time Teff has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from the four corners.A. TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.展开更多
A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in...A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources ^22 Na,^137Cs and ^60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.展开更多
A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was...A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).展开更多
In a scintillation detector, scintillation crystals are typically made into a 2-dimensional modular array. The location of incident gamma-ray needs be calibrated due to spatial response nonlinearity. Generally, positi...In a scintillation detector, scintillation crystals are typically made into a 2-dimensional modular array. The location of incident gamma-ray needs be calibrated due to spatial response nonlinearity. Generally, position histograms--the characteristic flood response of scintillation detectors are used for position calibration. In this paper, a position calibration method based on a crystal position lookup table which maps the inaccurate location calculated by Anger logic to the exact hitting crystal position has been proposed. Firstly, the position histogram is preprocessed, such as noise reduction and image enhancement. Then the processed position histogram is segmented into disconnected regions, and crystal marking points are labeled by finding the centroids of regions. Finally, crystal boundaries are determined and the crystal position lookup table is generated. The scheme is evaluated by the whole-body positron emission tomography (PET) scanner and breast dedicated single photon emission computed tomography scanner developed by the Institute of High Energy Physics, Chinese Academy of Sciences. The results demonstrate that the algorithm is accurate, efficient, robust and applicable to any configurations of scintillation detector.展开更多
Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a sel...Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.展开更多
Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors ...Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.展开更多
An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measure...An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.展开更多
The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete mat...The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.展开更多
In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating...In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.展开更多
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selectio...Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.展开更多
The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performa...The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.展开更多
High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass...High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.展开更多
In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors b...In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.展开更多
As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the ...As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the vacuum-dominated region.For a large-scale liquid scintillator detector,a bottleneck for pp solar neutrino detection is the pile-up events of intrinsic14C decay.This paper presents a few approaches to discriminating between pp solar neutrinos and ^(14)C pile-up events by considering the differences in their time and spatial distributions.In this study,a Geant4-based Monte Carlo simulation is conducted.Multivariate analysis and deep learning technology are adopted to investigate the capability of ^(14)C pile-up reduction.The BDTG (boosted decision trees with gradient boosting) model and VGG network demonstrate good performance in discriminating pp solar neutrinos and ^(14)C double pile-up events.Under the ^(14)C concentration assumption of 5×10-18g/g,the signal significance can achieve 10.3 and 15.6 using the statistics of only one day.In this case,the signal efficiency for discrimination using the BDTG model while rejecting 99.18% ^(14)C double pile-up events is 51.1%,and that for the case where the VGG network is used while rejecting 99.81%of the ^(14)C double pile-up events is 42.7%.展开更多
Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering material...Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer(EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near3 m2in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1A, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a onedimensional position-sensitive neutron detector based on the oblique6Li F/Zn S(Ag) scintillators, wavelength shifting fibers,and Si PMs(silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20(beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11705103,12005120).
文摘As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.
文摘Two measurement systems, one being comprised of three HPGe detectors and the other being a 4π measurement system of the assembly of 10 sets of scintillation detectors, were compared for their measurement performance in operations of radioactive waste drum radioactivity measurement and clearance and release operation of decommissioning. The system features of the former were high costs, capable of identifying radionuclides, a measurement time of about 1000 sec. The system features of the latter were high sensibility, capable of identifying hotspots, a measurement time of about 100 sec. Various comparisons were made for the differences of the two systems on reference drums, whole-drum homogeneous and non-homogeneous metal drums and non-metal drums, whole-drums of different filling rates. The aim was to compare the differences of the two measurement systems in measuring radioactivity of critical radionuclides of <sup>137</sup>Cs, <sup>54</sup>Mn and <sup>60</sup>Co.
基金supported by the National Magnetic Confinement Fusion Science Program (Grant No. 2010GB111002)
文摘The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network without biases and hidden layers is adopted. A set of monoenergetic detector response functions in the energy range from 0.25 MeV to 16 MeV with an energy interval of 0.25 MeV are generated by the Monte Carlo code O5S in the training phase of the unfolding process. The capability of ANN was demonstrated successfully using the Monte Carlo data itself and experimental data obtained from the Am-Be neutron source and D-T neutron source.
基金Supported by National Natural Science Foundation of China (10935005, 10945002)
文摘Neutron background measurement is always very important for dark matter detection due to almost the same effect for the recoiled nucleus scattered off by the incident neutron and dark matter particle. For deep under-ground experiments, the flux of neutron background is so low that large-scale detection is usually necessary. In this paper, by using Geant4, the relationship between detection efficiency and volume is investigated, meanwhile, two geometrical schemes for this detection including a single large-sized detector and arrayed multi-detector are compared under the condition of the same volume. The geometrical parameters of detectors are filtrated and detection efficiencies obtained under the similar background condition of China Jingping Underground Laboratory (CJPL). The results show that for a large-scale Gd-doped liquid scintillation detector, the detection efficiency increases with the size of detector at the beginning and then trends toward a constant. Under the condition of the same length and cross section, the arrayed multi-detector has almost similar detection performance as the single large-sized detector, while too much detector number could cause degeneration of detection performance. Considering engineering factors, such as testing, assembling and production, the 4 × 4 arrayed detector scheme is flexible and more suitable. Furthermore, the conditions for using fast and slow signal coincidence detection and the detectable lower limit of neutron energy are evaluated by simulating the light process.
基金Supported by National Natural Science Foundation of China(U1332207,11405242)
文摘A 760 mm × 760 mm× 30 mm plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and γrays. A position- independent effective time Teff has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from the four corners.A. TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.
基金Supported by National Natural Science Foundation of China(91226107,11305229)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA03030300)
文摘A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources ^22 Na,^137Cs and ^60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.
文摘A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).
基金Supported by National Natural Science Foundation of China(81101175)XIE Jia-Lin Foundation of Institute of High Energy Physics(Y3546360U2)
文摘In a scintillation detector, scintillation crystals are typically made into a 2-dimensional modular array. The location of incident gamma-ray needs be calibrated due to spatial response nonlinearity. Generally, position histograms--the characteristic flood response of scintillation detectors are used for position calibration. In this paper, a position calibration method based on a crystal position lookup table which maps the inaccurate location calculated by Anger logic to the exact hitting crystal position has been proposed. Firstly, the position histogram is preprocessed, such as noise reduction and image enhancement. Then the processed position histogram is segmented into disconnected regions, and crystal marking points are labeled by finding the centroids of regions. Finally, crystal boundaries are determined and the crystal position lookup table is generated. The scheme is evaluated by the whole-body positron emission tomography (PET) scanner and breast dedicated single photon emission computed tomography scanner developed by the Institute of High Energy Physics, Chinese Academy of Sciences. The results demonstrate that the algorithm is accurate, efficient, robust and applicable to any configurations of scintillation detector.
基金supported by the National Magnetic Confinement Fusion Program of China(No.2019YFE03020002)the National Natural Science Foundation of China(Nos.12205085 and12125502)。
文摘Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.
基金supported by the Tsinghua University Initiative Scientific Research Program,the National Natural Science Foundation of China(Nos.11633003,12025301,and 11821303)the National Key R&D Program of China(Nos.2018YFA0404502 and 2016YFA040080X).
文摘Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.
基金supported by the State Key Development Program for Basic Research of China (Nos. 2008CB717803, 2009GB107001,2007CB209903)the Research Fund for the Doctoral Program of Higher Education of China (No. 200610011023)National Natural Science Foundation of China (No. 10875002)
文摘An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.
文摘The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.
文摘In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.
基金supported by the National Natural Science Foundation of China(Nos.11805294 and 11975021)the China Postdoctoral Science Foundation(2018M631013),the Strategic Priority Research Program of Chinese Academy of Sciences(XDA10010900)+1 种基金the Fundamental Research Funds for the Central Universities,Sun Yatsen University(19lgpy268)in part by the CAS Center for Excellence in Particle Physics(CCEPP).
文摘Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.
基金supported by the National Natural Science Foundation of China(Nos.11975021,12175257,12175321,11675275,and U1932101)the Guangdong Basic and Applied Basic Research Foundation(No.2021A1515012039)+3 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10010900)the National College Students Science and Technology Innovation Projectthe Undergraduate Base Scientific Research Project of Sun Yat-sen Universitythe CAS Center for Excellence in Particle Physics(CCEPP).
文摘The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.
基金supported by the National Key R&D Program of China(No.2018YFA0404100)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.12175257)+1 种基金the National Natural Science Foundation of China(No.12175257)the Science Foundation of High-Level Talents of Wuyi University(No.2021AL027).
文摘High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.
基金the Ministry of Science and Technology of China(No.2016YFA0400301)the grants for the XENON Dark Matter Project。
文摘In recent years, cooling technology for liquid xenon(LXe) detectors has advanced driven by the development of dark matter(DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg(50 t)range requiring more than 1 k W of cooling power. Most of the prior cooling methods become impractical at this level.For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen(LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the ‘‘Cooling Bus’ ’employed for the Panda X I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.
基金supported by National Natural Science Foundation of China(No.12005044)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10011200)Guangxi Science and Technology Program(No.GuiKeAD21220037).
文摘As a unique probe,the precision measurement of pp solar neutrinos is important for studying the sun’s energy mechanism as it enables monitoring the thermodynamic equilibrium and studying neutrino oscillations in the vacuum-dominated region.For a large-scale liquid scintillator detector,a bottleneck for pp solar neutrino detection is the pile-up events of intrinsic14C decay.This paper presents a few approaches to discriminating between pp solar neutrinos and ^(14)C pile-up events by considering the differences in their time and spatial distributions.In this study,a Geant4-based Monte Carlo simulation is conducted.Multivariate analysis and deep learning technology are adopted to investigate the capability of ^(14)C pile-up reduction.The BDTG (boosted decision trees with gradient boosting) model and VGG network demonstrate good performance in discriminating pp solar neutrinos and ^(14)C double pile-up events.Under the ^(14)C concentration assumption of 5×10-18g/g,the signal significance can achieve 10.3 and 15.6 using the statistics of only one day.In this case,the signal efficiency for discrimination using the BDTG model while rejecting 99.18% ^(14)C double pile-up events is 51.1%,and that for the case where the VGG network is used while rejecting 99.81%of the ^(14)C double pile-up events is 42.7%.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11975255 and 11875273)Guangdong Basic and Applied Basic Research Foundation (Grant No. 2020B1515120025)。
文摘Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer(EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near3 m2in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1A, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a onedimensional position-sensitive neutron detector based on the oblique6Li F/Zn S(Ag) scintillators, wavelength shifting fibers,and Si PMs(silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20(beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well.