期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
China Seismo-Electromagnetic Satellite search coil magnetometerdata and initial results 被引量:8
1
作者 Qiao Wang JianPing Huang +4 位作者 XueMin Zhang XuHui Shen ShiGeng Yuan Li Zeng JinBin Cao 《Earth and Planetary Physics》 2018年第6期462-468,共7页
Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the wavefo... Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances. 展开更多
关键词 search coil magnetometer CSES data description EARTHQUAKE
下载PDF
Time Series-, Time-Frequency- and Spectral Analyses of Sensor Measurements in an Offshore Wave Energy Converter Based on Linear Generator Technology
2
作者 Erland Stromstedt Andrej Savin +1 位作者 Olle Svensson Mats Leijon 《Energy and Power Engineering》 2013年第1期70-91,共22页
Inside the second experimental wave energy converter (WEC) launched at the Lysekil research site on the Swedish west coast in March 2009 a number of sensor systems were installed for measuring the mechanical performan... Inside the second experimental wave energy converter (WEC) launched at the Lysekil research site on the Swedish west coast in March 2009 a number of sensor systems were installed for measuring the mechanical performance of the WEC and its mechanical subsystems. One of the measurement systems was a set-up of 7 laser triangulation sensors for measuring relative displacement of the piston rod mechanical lead-through transmission in the direct drive. Two measurement periods, separated by 2.5 month, are presented in this paper. One measurement is made two weeks after launch and another 3 months after launch. Comparisons and correlations are made between different sensors measuring simultaneously. Noise levels are investigated. Filtering is discussed for further refinement of the laser triangulation sensor signals in order to separate noise from actual physical displacement and vibration. Measurements are presented from the relative displacement of the piston rod mechanical lead-through, from magnetic flux in the air gap, mechanical strain in the WEC structure, translator position and piston rod axial displacement and active AC power. Investigation into the measurements in the time domain with close-ups, in the frequency domain with Fast Fourier transform (FFT) and with time-frequency analysis with short time Fourier transform (STFT) is carried out to map the spectral content in the measurements. End stop impact is clearly visible in the time-frequency analysis. The FFT magnitude spectra are investigated for identifying the cogging bandwidth among other vibrations. Generator cogging, fluctuations in the damping force and in the Lorenz forces in the stator are distinguished and varies depending on translator speed. Vibrations from cogging seem to be present in the early measurement period while not so prominent in the late measurement period. Vibration frequencies due to wear are recognized by comparing with the noise at generator standstill and the vibration sources in the generator. It is concluded that a moving average is a sufficient filter in the time domain for further analysis of the relative displacement of the piston rod mechanical lead-through transmission. 展开更多
关键词 Wave Power Wave Energy Converter Linear Generator Sensor Measurements Spectral Analysis COGGING Filtering Laser Triangulation Sensor Draw-Wire Sensor Force Transducer Strain Gauges search Coil Power Generation
下载PDF
The electromagnetic wave experiment for CSES mission: Search coil magnetometer 被引量:17
3
作者 CAO JinBin ZENG Li +8 位作者 ZHAN Feng WANG ZuoGui WANG Yan CHEN Yu MENG QingChun JI ZhanQiang WANG PengFei LIU ZhongWei MA LingYu 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第5期653-658,共6页
The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is ... The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission. 展开更多
关键词 search coil magnetometer CSES electromagnetic wave earthquake precursor
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部