The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While curren...The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While current numerical calculation methods suffer from poor precision, especially in frequency band near Nyquist frequency, we present a set of improved parameters for precision improvement. It is shown that precision of displacement and velocity response spectra are both further improved compared to current numerical algorithms. A uniform fitting formula is given for computing these parameters for damping ratio range of 0.01-0.9, quite convenient for practical application.展开更多
An industrial building is a non-classically damped system due to the different damping properties of the primary structure and equipment.The objective of this paper is to quantify the range of applicability of the rea...An industrial building is a non-classically damped system due to the different damping properties of the primary structure and equipment.The objective of this paper is to quantify the range of applicability of the real model superposition approximation method to the seismic response calculation of industrial buildings.The analysis using lumped mass-and-shear spring models indicates that for the equipment-to-structure frequency ratiosγf>1.1 orγf<0.9,the non-classical damping effect is limited,and the real mode superposition approximation method provides accurate estimates.For 0.9<γf<1.1,the system may have a pair of closely spaced frequency modes,and the non-zero off-diagonal damping terms have a non-negligible effect on the damping ratios and mode shape vectors of these modes.For 0.9<γf<1.1 and the equipment-to-structure mass ratiosγm<0.07,the real mode superposition approximation method results in large errors,while the approximation method can provide an accurate estimation for 0.9<γf<1.1 andγm>0.07.Furthermore,extensive parametric analyses are conducted,where both steel structures and reinforced concrete structures with equipment with various damping ratios are considered.Finally,the finite element analysis of a five-story industrial building is adopted to validate the proposed range of applicability.展开更多
基金supported by Science for Earthquake Resilience (XH12032)
文摘The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While current numerical calculation methods suffer from poor precision, especially in frequency band near Nyquist frequency, we present a set of improved parameters for precision improvement. It is shown that precision of displacement and velocity response spectra are both further improved compared to current numerical algorithms. A uniform fitting formula is given for computing these parameters for damping ratio range of 0.01-0.9, quite convenient for practical application.
基金Fund of China National Industrial Building Diagnosis and Reconstruction Engineering Technology Research Center under Grant No.YZA2017Ky03the Beijing Natural Science Foundation under Grant No.JQ18029the National Natural Science Foundation of China under Grant No.52078277。
文摘An industrial building is a non-classically damped system due to the different damping properties of the primary structure and equipment.The objective of this paper is to quantify the range of applicability of the real model superposition approximation method to the seismic response calculation of industrial buildings.The analysis using lumped mass-and-shear spring models indicates that for the equipment-to-structure frequency ratiosγf>1.1 orγf<0.9,the non-classical damping effect is limited,and the real mode superposition approximation method provides accurate estimates.For 0.9<γf<1.1,the system may have a pair of closely spaced frequency modes,and the non-zero off-diagonal damping terms have a non-negligible effect on the damping ratios and mode shape vectors of these modes.For 0.9<γf<1.1 and the equipment-to-structure mass ratiosγm<0.07,the real mode superposition approximation method results in large errors,while the approximation method can provide an accurate estimation for 0.9<γf<1.1 andγm>0.07.Furthermore,extensive parametric analyses are conducted,where both steel structures and reinforced concrete structures with equipment with various damping ratios are considered.Finally,the finite element analysis of a five-story industrial building is adopted to validate the proposed range of applicability.