期刊文献+
共找到4,008篇文章
< 1 2 201 >
每页显示 20 50 100
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
1
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Sedimentary microfacies of the H8 member in the Su14 3D seismic test area
2
作者 Zhang Yuqing Wang Zhizhang 《Mining Science and Technology》 EI CAS 2011年第2期233-237,共5页
The distribution of sedimentary microfacies in the eighth member of the Shihezi formation(the H8 member) in the Sul4 3D seismic test area was investigated.A Support Vector Machine(SVM) model was introduced for the... The distribution of sedimentary microfacies in the eighth member of the Shihezi formation(the H8 member) in the Sul4 3D seismic test area was investigated.A Support Vector Machine(SVM) model was introduced for the first time as a way of predicting sandstone thickness in the study area.The model was constructed by analysis and optimization of measured seismic attributes.The distribution of the sedimentary microfacies in the study area was determined from predicted sandstone thickness and an analysis of sedimentary characteristics of the area.The results indicate that sandstone thickness predictions in the study area using an SVM method are good.The distribution of the sedimentary microfacies in the study area has been depicted at a fine scale. 展开更多
关键词 SVM seismic attribute Sandstone thickness Sedimentary microfacies 3D seismic test area
下载PDF
Studies on parallel seismic testing for integrity of cemented soil columns 被引量:4
3
作者 HUANG Da-zhi CHEN Long-zhu 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第11期1746-1753,共8页
The principle and process of parallel seismic (PS) testing for the integrity testing of cemented soil columns are in- troduced in this paper. A three-dimensional (3D) finite element model (FEM) for the pile-soil syste... The principle and process of parallel seismic (PS) testing for the integrity testing of cemented soil columns are in- troduced in this paper. A three-dimensional (3D) finite element model (FEM) for the pile-soil system is established for impulse responses. Under saturated soil or unsaturated soil condition, several vibrating velocity-time histories at different depths in parallel hole are obtained based on the numerical simulation. It shows that the length of the pile and the one-dimensional (1D) P-wave velocity in the pile can be determined easily from the features of the mentioned velocity-time histories. By examining the slopes of the first arrival time plotted versus depth or the depth where the amplitude of the first arrival significantly decreases, the length of the pile can be determined. The effects of the 3D P-wave propagation through the saturated soil and the defect of the cemented soil column on the velocity-time histories are also investigated. 展开更多
关键词 Parallel seismic (PS) testing Cemented soil columns Integrity testing Numerical simulation
下载PDF
Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls 被引量:3
4
作者 Li Wenfeng Wang Tao +2 位作者 Chen Xi Zhong Xiang Pan Peng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第3期587-597,共11页
A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system s... A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests. 展开更多
关键词 masonry buildings precast SRC panel seismic retrofit pseudo-dynamic test seismic performance
下载PDF
Generalized Rydelek-Sacks test for distinguishing between periodic and randompatterns in seismicity 被引量:2
5
作者 吴忠良 《Acta Seismologica Sinica(English Edition)》 CSCD 1999年第5期534-541,共8页
For distinguishing the periodicity of strong earthquakes on the time scale of decades, we generalized the Rydelek-Sacks test (R) delek. Sacks. 1989) to explore whether a time series is modulated by a periodic process ... For distinguishing the periodicity of strong earthquakes on the time scale of decades, we generalized the Rydelek-Sacks test (R) delek. Sacks. 1989) to explore whether a time series is modulated by a periodic process or not. Thetest is conducted by comparing the total phasor of seismicity with that produced by a random Brownian motion.The phdse angle is defined by the origin time of earthquakes relative to a reference time scale. Using this methodwe tested two hypotheses in geodynamics and earthquake prediction study. One is the hypothesis of Romanowicz( 1993 ) who proposed that the great earthquakes alternate in a predictable fashion between strike-slip and thrustingmechanisms oil a 20~30 years cycle. The other hypothesis is that the strong earthquakes in and around China havean active period of about ten years. The test obtains a negative conclusion for the former hypothesis and a positiveconclusion for the latter at the 93% confidence level. 展开更多
关键词 seismicITY Rydelek-Sacks test PERIODICITY earthquake prediction
下载PDF
Global test of seismic static stress triggering model 被引量:1
6
作者 万永革 吴忠良 +2 位作者 周公威 黄静 秦立新 《Acta Seismologica Sinica(English Edition)》 CSCD 2002年第3期318-332,共15页
Seismic static stress triggering model is tested using Harvard centroid moment tensor (CMT) solution catalogue of 1976~2000 and concept of earthquake doublet. Result shows that seismic static stress triggering effect ... Seismic static stress triggering model is tested using Harvard centroid moment tensor (CMT) solution catalogue of 1976~2000 and concept of earthquake doublet. Result shows that seismic static stress triggering effect does exist in the view of global earthquakes, but the effect is very weak. Dividing the earthquakes into thrust focal mechanism, normal focal mechanism, strike-slip focal mechanism, we find that non-strike-slip focal mechanism earthquakes have significant triggering effect, whereas, the triggering effect in strike-slip focal mechanism earthquakes is not obvious. Divided the subsequent events delay time of earthquake doublet into 5 classes of t1, t<1, t10, t<10, 1t10 (t is in unit of d), then seismic static stress triggering effect does not change with delay time in short time period after earthquakes. The research on seismic static stress triggering in different regions of the world indicates that triggering effect is significant in subduction belts. Seismic static stress triggering model is tested by using earthquake doublets in China and its adjacent region. The result indicates that seismic static stress triggering effect cannot be observed easily in China and its adjacent region due to the seismic focal mechanism type (most of the earthquakes are strike-slip earthquakes). 展开更多
关键词 stress triggering global test seismic catalogue focal mechanism type
下载PDF
Soil Liquefaction Hazard Evaluation by the New Seismic Dilatometer Marchetti Test (SDMT)
7
作者 Salvatore Grasso Michele Maugeri 《Journal of Civil Engineering and Architecture》 2010年第3期36-45,共10页
Soil liquefaction, and the permanent deformations that frequently result from it, have caused significant damage in past earthquakes. The procedures used in contemporary geotechnical earthquake engineering practice ar... Soil liquefaction, and the permanent deformations that frequently result from it, have caused significant damage in past earthquakes. The procedures used in contemporary geotechnical earthquake engineering practice are generally based on simplified procedures for the evaluation of the liquefaction potential. The work describes a framework for performance-based earthquake engineering and its use in the development of a performance-based procedure for liquefaction hazard evaluation. The performance-based procedure will be used to show how consistent application of conventional procedures for evaluation of liquefaction potential can influence performance prediction. Implications for liquefaction-resistant design will also be discussed. The purpose is to summarize current procedures for practical prediction of liquefaction behavior, to describe recent advances in the understanding of liquefaction behavior, and to describe the incorporation of this improved understanding into new solutions for detailed modeling of soil liquefaction, Simplified procedures for evaluation of liquefaction hazards will be reviewed relatively briefly, with more details devoted to emerging knowledge about the mechanics of liquefiable soil behavior, and methods for incorporating those mechanics into improved models for performance prediction. In particular it focuses about the influence on the evaluation of Cyclic Resistance Ratio (CRR) by different in-situ tests (Cone Penetration Test (CPT). Standard Penetration Test (SPT) and Seismic Dilatometer Marchetti Test (SDMT)) and by different shear waves velocity measurements (Down Hole D-H. Cross Hole C-H, Seismic Dilatometer Marchetti Test SDMT). 展开更多
关键词 Liquefaction Potential Index seismic Dilatometer Marchetti test (SDMT) Cyclic Resistance Ratio (CRR) Cyclic Stress Ratio (CSR).
下载PDF
Seismic performance evaluation of an infilled rocking wall frame structure through quasi-static cyclic testing 被引量:8
8
作者 Pan Peng Wu Shoujun +1 位作者 Wang Haishen Nie Xin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期371-383,共13页
Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous ... Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience. 展开更多
关键词 infilled rocking wall frame seismic performance displacement distribution quasi-static cyclic test
下载PDF
Seismic responses of the steel-strip reinforced soil retaining wall with full-height rigid facing from shaking table test 被引量:4
9
作者 CAO Li-cong FU Xiao +3 位作者 WANG Zhi-jia ZHOU Yong-yi LIU Fei-cheng ZHANG Jian-jing 《Journal of Mountain Science》 SCIE CSCD 2018年第5期1137-1152,共16页
To investigate the seismic response of the steel-strip reinforced soil retaining wall with fullheight rigid facing in terms of the acceleration in the backfill, dynamic earth pressure in the backfill, the displacement... To investigate the seismic response of the steel-strip reinforced soil retaining wall with fullheight rigid facing in terms of the acceleration in the backfill, dynamic earth pressure in the backfill, the displacements on the facing and the dynamic reinforcement strain distribution under different peak acceleration, a large 1-g shaking table test was performed on a reduced-scale reinforced-earth retaining wall model. It was observed that the acceleration response in non-strip region is greater than that in potential fracture region which is similar with the stability region under small earthquake,while the acceleration response in potential fracture region is greater than that in stability region in middle-upper of the wall under moderately strong earthquakes. The potential failure model of the rigid wall is rotating around the wall toe. It also was discovered that the Fourier spectra produced by the inputting white noises after seismic wave presents double peaks, rather than original single peak, and the frequency of the second peak trends to increase with increasing the PGA(peak ground amplitude) of the excitation which is greater than 0.4 g. Additionally,the non-liner distribution of strip strain along the strips was observed, and the distribution trend was not constant in different row. Soil pressure peak value in stability region is larger than that in potential fracture region. The wall was effective under 0.1 g-0.3 g seismic wave according to the analyses of the facing displacement and relative density. Also, it was discovered that the potential failure surface is corresponds to that in design code, but the area is larger. The results from the study can provide guidance for a more rational design of reinforced earth retaining walls with full-height rigid facing in the earthquake zone. 展开更多
关键词 Reinforced soil retaining walls Potentialfailure surface Full-height RIGID FACING STEEL STRIP seismic behaviors 1-g SHAKING table test
下载PDF
钢支撑-钢筋混凝土掉层框架结构抗震性能试验研究 被引量:2
10
作者 刘立平 李瑞锋 +2 位作者 殷尧日 李英民 邓飞 《工程力学》 EI CSCD 北大核心 2024年第1期182-192,共11页
为改善坡地钢筋混凝土(RC)掉层框架结构抗侧刚度分布的不均匀性,设计了一栋在上接地层设置钢支撑的RC掉层框架结构,按1/4比例提取其顺坡向中榀框架下部5层子结构为试验对象,开展钢支撑-RC掉层框架拟静力试验,观测试件的破坏过程,并对比R... 为改善坡地钢筋混凝土(RC)掉层框架结构抗侧刚度分布的不均匀性,设计了一栋在上接地层设置钢支撑的RC掉层框架结构,按1/4比例提取其顺坡向中榀框架下部5层子结构为试验对象,开展钢支撑-RC掉层框架拟静力试验,观测试件的破坏过程,并对比RC掉层框架试验所得试件的破坏形态,分析试件滞回性能、延性和刚度退化等抗震性能指标。结果表明:试件的最终破坏是以第4层柱底混凝土压溃,梁端混凝土剥落、底部钢筋断裂,顶层柱顶混凝土剥落为标志。与RC掉层框架试验结果相比,钢支撑-RC掉层框架试件上接地柱的破坏明显减轻,柱端破坏分布也更为均匀,避免了掉层框架结构“半层破坏模式”的出现,改善了结构的耗能和抗地震倒塌能力。但试件上接地层相邻上一层的变形和破坏程度较大,应对该楼层的柱端进行适当的抗震加强;设置钢支撑后,试件的滞回曲线较为饱满,并具有良好的延性(正、负向加载的位移延性系数分别可达5.13、5.69),正负向加载的刚度退化曲线也趋于对称。 展开更多
关键词 掉层框架结构 钢支撑 拟静力试验 抗震性能 破坏模式
下载PDF
Earthquake simulation test of circular reinforced concrete bridge column under multidirectional seismic excitation 被引量:4
11
作者 Junichi Sakai Shigeki Unjoh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第1期103-110,共8页
Structures behave multi-directionally when subjected to earthquake excitation. Thus, it is essential to evaluate the effect of multidirectional loading on the dynamic response and seismic performance of reinforced con... Structures behave multi-directionally when subjected to earthquake excitation. Thus, it is essential to evaluate the effect of multidirectional loading on the dynamic response and seismic performance of reinforced concrete bridge columns in order to develop more advanced and reliable design procedures. To investigate such effects, a 1/4 scaled circular reinforced concrete bridge column specimen was tested under two horizontal and one vertical components of a strong motion that has long duration with several strong pulses. Damage progress of reinforced concrete columns subjected to strong excitation was evaluated from the test. The test results demonstrate that the lateral force response in the principal directions become smaller than computed flexural capacity due to the bilateral flexural loading effects, and that the lateral response is not significantly affected by the fluctuation of the axial force because the horizontal response and axial force barely reached the maximum simultaneously due to difference of the predominant natural periods between the vertical and the horizontal directions. Accuracy of fiber analyses is discussed using the test results. 展开更多
关键词 multidirectional seismic excitation reinforced concrete bridge columns shake table test nonlinear dynamic analyses fiber analysis
下载PDF
单跨两层含减震外挂墙板装配式混凝土框架拟静力试验研究 被引量:3
12
作者 种迅 霍璞 +4 位作者 沙慧玲 蒋庆 李浩然 侯林兵 冯玉龙 《工程力学》 EI CSCD 北大核心 2024年第1期114-123,共10页
该文在对一个含减震外挂墙板平面框架(简称减震结构)以及一个作为对比的纯框架(简称抗震结构)进行混合试验的基础上,进一步对其单跨2层试验子结构进行了拟静力试验,研究了两结构在水平地震作用下的受力过程、损伤模式及减震外挂墙板对... 该文在对一个含减震外挂墙板平面框架(简称减震结构)以及一个作为对比的纯框架(简称抗震结构)进行混合试验的基础上,进一步对其单跨2层试验子结构进行了拟静力试验,研究了两结构在水平地震作用下的受力过程、损伤模式及减震外挂墙板对主体结构抗震性能的影响。研究结果表明:减震结构和抗震结构的破坏机制均为梁端和柱底出现塑性铰的梁铰机制,减震外挂墙板未改变主体结构的破坏模式;减震结构中,在最大层间位移角达到1/55之前,消能器呈预期的履带式滚动变形,此后由于外挂墙板的面内转动变形,消能器水平剪切变形值增加不大,且圆弧段产生明显变形;试验过程中减震外挂墙板未出现裂缝;墙板与框架间上部线连接处裂缝宽度较小,连接钢筋应变也较小,表明连接可靠;两试件均具有较好的变形能力和耗能能力;在相同位移级别下,减震结构的刚度、极限承载力和耗能能力均更好。 展开更多
关键词 减震外挂墙板 装配式混凝土框架 U型钢板消能器 拟静力试验 抗震性能
下载PDF
基于CNN-LSTM混合神经网络的高速铁路地震响应预测 被引量:2
13
作者 张学兵 谢啸楠 +1 位作者 王礼 吴晗 《湘潭大学学报(自然科学版)》 CAS 2024年第1期1-13,共13页
为了更好地挖掘高速铁路在地震时的响应信息,提高光纤光栅监测的效率及预测精度,该文针对地震响应数据的时序性及非线性的特点,提出卷积神经网络(CNN)和长短期记忆(LSTM)网络的混合神经网络模型预测方法.通过在高速铁路简支梁桥上布设... 为了更好地挖掘高速铁路在地震时的响应信息,提高光纤光栅监测的效率及预测精度,该文针对地震响应数据的时序性及非线性的特点,提出卷积神经网络(CNN)和长短期记忆(LSTM)网络的混合神经网络模型预测方法.通过在高速铁路简支梁桥上布设准分布式光纤光栅采集地震时轨道板、钢轨、底座板、箱梁的响应数据,在每根光纤上布置7个光栅,利用两边光栅的响应数据预测中间点的光栅响应,将采集位置、历史数据及地震波形等信息作为特征图输入.利用CNN提取特征,再将提前提取出来的特征数据以时序方式作为LSTM网络的输入数据,最后LSTM网络进行地震应变响应预测.实验结果表明,LSTM网络在3层时效果最好,CNN-LSTM方法具有较高的预测精度,根均平方误差(R_(RMSE))、平均绝对误差(R_(MAE))、决定系数(R^(2))分别达到了0.3753、0.2968、0.9371. 展开更多
关键词 准分布式光纤光栅 振动台试验 地震响应 卷积神经网络-长短期记忆网络混合模型
下载PDF
液化场地大直径变截面单桩动力响应研究 被引量:1
14
作者 冯忠居 段久琴 +3 位作者 张聪 林立华 赵瑞欣 王逸然 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第5期56-67,共12页
为研究不同地震动强度下液化场地大直径变截面单桩的动力响应规律,基于振动台试验,选取5010波,在地震动强度0.10g~0.45g作用下,研究液化场地砂土孔压比和大直径变截面单桩桩顶水平位移、桩身弯矩、桩身加速度时程响应及桩基损伤等变化规... 为研究不同地震动强度下液化场地大直径变截面单桩的动力响应规律,基于振动台试验,选取5010波,在地震动强度0.10g~0.45g作用下,研究液化场地砂土孔压比和大直径变截面单桩桩顶水平位移、桩身弯矩、桩身加速度时程响应及桩基损伤等变化规律.试验结果表明:饱和砂土孔压比随着地震动强度的增大上升明显,地震动强度≥0.30g时,饱和砂土孔压比稳定值在0.9附近,此时砂土完全液化;在0.45g地震动强度作用下,桩身加速度、桩顶水平位移及桩身弯矩均达到最大;桩身不同位置处加速度峰值出现时刻均滞后于输入地震波加速度峰值出现时刻,且桩顶及变截面的加速度响应比桩端的响应更弱;不同地震动强度作用下,桩身弯矩最大值均出现在液化土层和非液化土层分界处,且变截面处弯矩小于土层分界面处;地震动强度达到0.30g时,大直径变截面单桩桩身发生损伤.因此,液化场地下大直径变截面桥梁单桩基础抗震设计时,应该重点考虑饱和砂土层分界处、变截面处的抗弯能力,以确保单桩桩身强度满足抗震要求. 展开更多
关键词 岩土工程 变截面单桩 液化场地 动力响应 振动台试验 抗震设计
下载PDF
一种新型结构与保温一体化复合墙板节点试验
15
作者 马少春 谷宇 鲍鹏 《防灾减灾工程学报》 CSCD 北大核心 2024年第2期396-403,共8页
为解决复合墙板节点常见的保温板易燃、易脱落等棘手问题,并使其抗震性能良好。给出了一种新型的结构与保温一体化陶粒混凝土T型复合墙板节点。该复合墙板节点具有夹芯独特构造优势,主要表现在绿色节能,轻质高强,力学性能好,保温系统连... 为解决复合墙板节点常见的保温板易燃、易脱落等棘手问题,并使其抗震性能良好。给出了一种新型的结构与保温一体化陶粒混凝土T型复合墙板节点。该复合墙板节点具有夹芯独特构造优势,主要表现在绿色节能,轻质高强,力学性能好,保温系统连接可靠,还能杜绝火灾的发生。通过对T型复合墙板节点进行抗震试验,分别研究了其滞回性能、破坏机理、承载及变形能力、延性、耗能、损伤等。结果表明:一体化复合墙板节点的破坏顺序为腹板-翼缘-节点核心区;薄弱位置主要发生在腹板脚部,混凝土被拉裂或压碎,钢筋被拉长或压弯等;节点核心区受力相对良好,安全储备充足;符合“强节点,弱构件”设计要求和墙板革新发展政策。延性系数大于3,墙板节点安全性能良好。通过损伤指标评估分析,了解了试件各阶段工作状态。 展开更多
关键词 结构与保温一体化 复合墙板节点 抗震试验 滞回及骨架曲线 损伤指标
下载PDF
链式海底地震仪节点结构设计与试验
16
作者 张川 周建平 +4 位作者 阮爱国 翁利春 段磊 曾锦锋 陈宁特 《地震工程学报》 CSCD 北大核心 2024年第3期672-679,共8页
海底地震仪是一种重要的海洋地震观测设备。针对中国近岸浅海洋流噪声大和人类活动频繁的特点,提出链式地震观测方式并对链式海底地震仪节点进行机械结构设计。首先根据内部构件尺寸与布局对地震仪节点整体结构进行设计;然后通过理论计... 海底地震仪是一种重要的海洋地震观测设备。针对中国近岸浅海洋流噪声大和人类活动频繁的特点,提出链式地震观测方式并对链式海底地震仪节点进行机械结构设计。首先根据内部构件尺寸与布局对地震仪节点整体结构进行设计;然后通过理论计算与有限元仿真方式确定地震仪节点仓体的壳体厚度、端盖厚度和密封尺寸;最后通过压力试验验证所设计的地震仪节点结构的耐压和水密性能符合要求,通过地震观测对比试验验证其接收天然地震的能力。此链式海底地震仪未来将应用于浙江近海的实际地震观测,提供实时连续的地震观测数据。 展开更多
关键词 链式地震仪 结构设计 仿真计算 压力试验 地震试验
下载PDF
基础隔震-外挂墙板减震钢筋混凝土框架振动台试验研究 被引量:1
17
作者 种迅 郭宇菲 +3 位作者 沙慧玲 黄俊旗 乐腾胜 魏建鹏 《工程力学》 EI CSCD 北大核心 2024年第7期176-185,共10页
该文提出一种新型的基础隔震-外挂墙板减震混合控制结构(简称“隔震-减震结构”)。该结构采用铅芯橡胶隔震支座作为基础隔震装置,上部结构则采用外挂墙板与U型金属消能器联合构成减震系统。通过减震与隔震混合控制,实现主体结构和围护... 该文提出一种新型的基础隔震-外挂墙板减震混合控制结构(简称“隔震-减震结构”)。该结构采用铅芯橡胶隔震支座作为基础隔震装置,上部结构则采用外挂墙板与U型金属消能器联合构成减震系统。通过减震与隔震混合控制,实现主体结构和围护墙体在罕遇地震下不发生损伤,可用于对韧性性能要求较高的生命线工程中。为对比研究隔震-减震结构与传统隔震结构的抗震性能,设计制作了一个在两方向上完全一致的1/2缩尺基础隔震钢筋混凝土框架结构,并在Y方向附加外挂墙板和U型金属消能器,形成隔震-减震结构,X方向不含外挂墙板,为隔震结构。分别在两个方向输入单向地震动进行振动台试验,试验结果表明:相比隔震结构,隔震-减震结构能进一步降低结构在设防和罕遇地震下的位移响应;隔震-减震结构在罕遇地震下最大层间位移角小于或接近钢筋混凝土框架结构弹性层间位移角限值,主体结构保持弹性,外挂墙板未出现损伤,可以实现预期的性能目标。 展开更多
关键词 基础隔震 外挂墙板减震 混合控制 U型金属消能器 振动台试验 抗震性能
下载PDF
高延性混凝土加固单层砖木结构农房振动台试验研究 被引量:2
18
作者 邓明科 孙严廷 +2 位作者 张思海 舒宏博 李彤 《工程力学》 EI CSCD 北大核心 2024年第1期90-102,113,共14页
为提高我国农村砌体房屋的抗震性能水平,采用高延性混凝土(HDC)条带加固的方法,设计了两个缩尺比为1∶2的砖木结构模型,对加固模型与未加固模型进行振动台同台对比试验。对比分析了地震作用下两个模型结构的加速度响应、位移响应、扭转... 为提高我国农村砌体房屋的抗震性能水平,采用高延性混凝土(HDC)条带加固的方法,设计了两个缩尺比为1∶2的砖木结构模型,对加固模型与未加固模型进行振动台同台对比试验。对比分析了地震作用下两个模型结构的加速度响应、位移响应、扭转效应和破坏形态,并对其抗震性能进行评估。试验结果表明:单层砖木结构农房的整体抗震性能较差,结构的自振频率低、位移反应较大,扭转效应明显,在8度设防地震作用下接近倒塌;经HDC条带加固的模型结构自振频率增大,位移反应相比未加固模型更小,山墙外闪现象得到明显控制,结构扭转效应的破坏作用明显减轻,在9度罕遇地震作用下HDC面层只出现轻微受损,可达到“大震可修”的性能目标。采用HDC条带加固法可有效延缓结构在强震作用下的刚度退化,增加结构的耐损伤能力,并有效提高此类砌体结构的整体抗震能力。 展开更多
关键词 高延性混凝土(HDC) 砖木结构 农村房屋 振动台试验 抗震加固 抗震性能
下载PDF
电机设备三维隔震试验研究
19
作者 聂桂波 徐卫丹 +2 位作者 马加路 王志詠 石宇杰 《地震研究》 CSCD 北大核心 2024年第1期156-162,共7页
针对核电设备设计研制了三维隔震支座,以核电设备常用的电机为例,对其三维隔震性能开展了振动台试验研究,获得了电机设备典型部位的隔震动力响应,通过对比振动台台面数据与设备测点位置的数据来验证隔震支座的隔震效果。结果表明:随着... 针对核电设备设计研制了三维隔震支座,以核电设备常用的电机为例,对其三维隔震性能开展了振动台试验研究,获得了电机设备典型部位的隔震动力响应,通过对比振动台台面数据与设备测点位置的数据来验证隔震支座的隔震效果。结果表明:随着输入地震动峰值增大,隔震支座的隔震效率差别微小,隔震效果比较稳定,说明隔震支座对电机设备起到了良好的隔震作用。 展开更多
关键词 电机设备 隔震支座 振动台试验 隔震效率
下载PDF
喷涂聚氨酯弹性体加固砌体墙抗震性能试验研究
20
作者 刘洋 刘阳 +2 位作者 田颖 黄群贤 张艺欣 《工程力学》 EI CSCD 北大核心 2024年第4期174-183,共10页
为提高村镇砖砌体墙结构抗震性能,采用喷涂聚氨酯技术对其进行加固。设计并制作了一片未加固砌体墙与两片加固后砌体墙,进行水平低周往复加载试验,主要研究加固形式(单面喷涂及双面喷涂)对砌体墙破坏形态、滞回特性、骨架曲线、变形性... 为提高村镇砖砌体墙结构抗震性能,采用喷涂聚氨酯技术对其进行加固。设计并制作了一片未加固砌体墙与两片加固后砌体墙,进行水平低周往复加载试验,主要研究加固形式(单面喷涂及双面喷涂)对砌体墙破坏形态、滞回特性、骨架曲线、变形性能、耗能能力和刚度退化等的影响。试验结果表明:喷涂聚氨酯弹性体可有效限制墙体开裂并延缓刚度退化,显著提高墙体的变形性能及耗能能力,而对墙体承载力及刚度影响有限。相较于单面喷涂加固,双面喷涂加固可更有效限制裂缝发展,维持墙体整体性,进一步提高墙体滞回性能、变形能力及耗能能力。 展开更多
关键词 砖砌体墙 聚氨酯弹性体 拟静力试验 抗震性能 加固
下载PDF
上一页 1 2 201 下一页 到第
使用帮助 返回顶部