期刊文献+
共找到18,451篇文章
< 1 2 250 >
每页显示 20 50 100
Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures
1
作者 Chee Lim Jonathan Ng +4 位作者 Babak Sarraf Rhys Vaughan Marios Efthymiou Leonardo Zorron Cheng Tao Pu Sujievvan Chandran 《World Journal of Transplantation》 2024年第2期88-98,共11页
BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on s... BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures. 展开更多
关键词 Liver transplantation CHOLANGIOPANCREATOGRAPHY Endoscopic retrograde CONSTRICTION PATHOLOGIC Self expandable metallic stents Bile duct diseases CHOLESTASIS
下载PDF
Outcomes of a non-randomised audit of single pigtail suture stents in urolithiasis management of Asian patients in Singapore
2
作者 Ee Jean Lim Zhen Wei Choo +8 位作者 Reshma Mangat Pradeep Durai Sarvajit Biligere Yiquan Tan Loh Hin Yeung Marcus Nicole Andrea Seet Li Ting Chin Tiong Heng Stefania Ferreti Vineet Gauhar 《Asian Journal of Urology》 CSCD 2024年第2期324-330,共7页
Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symp... Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting. 展开更多
关键词 stent URETEROSCOPY Pigtail suture stent Asianpatient Flexible ureteroscopic renal surgery
下载PDF
Can we predict the incidence of high-grade Clavien-Dindo complications in patients with forgotten encrusted stents undergoing endourologic management?
3
作者 Praanjal Gupta Ramanitharan Manikandan +3 位作者 Lalgudi Narayanan Dorairajan Kodakattil Sreenivasan Sreerag Sidhartha Kalra Swapnil Singh Kushwaha 《Asian Journal of Urology》 CSCD 2024年第1期99-104,共6页
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re... Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management. 展开更多
关键词 Forgotten Encrusted stent Outcome Predictor Clavien-Dindo complication
下载PDF
Long-term outcomes of titanium-nitride-oxide coated stents and drug-eluting stents in acute coronary syndrome:A systematic review and meta-analysis
4
作者 Muhammad Ahmed Ali Fahim Afia Salman +12 位作者 Hira Anas Khan Syed Muhammad Hasan Muskan FatimaBhojani Sarah Aslam Amna Zia Ul Haq Vishal Reddy Bejugam Beena Muntaha Nasir Wajiha Gul Abdul Moeed Abdelrahman S Abdalla Muhammad Majid Muhammad Sohaib Asghar Md Al Hasibuzzaman 《World Journal of Cardiology》 2024年第5期293-305,共13页
BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM T... BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES. 展开更多
关键词 stents DRUG-ELUTING Major adverse cardiac events All-cause death META-ANALYSIS
下载PDF
Outcomes of colon self-expandable metal stents for malignant vs benign indications at a tertiary care center and review of literature
5
作者 Saqib Walayat Andrew J Johannes +7 位作者 Mark Benson Eric Nelsen Ahmed Akhter Gregory Kennedy Anurag Soni Mark Reichelderfer Patrick Pfau Deepak Gopal 《World Journal of Gastrointestinal Endoscopy》 2023年第4期309-318,共10页
BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwi... BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwide analysis showing only 5.4%of patients with colon obstruction undergoing stent placement.This underutilization could be due to perceived increase risk of complications with stent placement.AIM To review long-and short-term clinical success of SEMS use for colonic obstruction at our center.METHODS We retrospectively reviewed all the patients who underwent colonic SEMS placement over aeighteen year period (August 2004 through August 2022) at our academic center. Demographicsincluding age, gender, indication (malignant and benign), technical success, clinical success,complications (perforation, stent migration), mortality, and outcomes were recorded.RESULTSSixty three patients underwent colon SEMS over an 18-year period. Fifty-five cases were formalignant indications, 8 were for benign conditions. The benign strictures included diverticulardisease stricturing (n = 4), fistula closure (n = 2), extrinsic fibroid compression (n = 1), and ischemicstricture (n = 1). Forty-three of the malignant cases were due to intrinsic obstruction from primaryor recurrent colon cancer;12 were from extrinsic compression. Fifty-four strictures occurred on theleft side, 3 occurred on the right and the rest in transverse colon. The total malignant case (n = 55)procedural success rate was 95% vs 100% for benign cases (P = 1.0, NS). Overall complication ratewas significantly higher for benign group: Four complications were observed in the malignantgroup (stent migration, restenosis) vs 2 of 8 (25%) for benign obstruction (1-perforation, 1-stentmigration) (P = 0.02). When stratifying complications of perforation and stent migration there wasno significant difference between the two groups (P = 0.14, NS).CONCLUSIONColon SEMS remains a worthwhile option for colonic obstruction related to malignancy and has ahigh procedural and clinical success rate. Benign indications for SEMS placement appear to havesimilar success to malignant. While there appears to be a higher overall complication rate inbenign cases, our study is limited by sample size. When evaluating for perforation alone theredoes not appear to be any significant difference between the two groups. SEMS placement may bea practical option for indications other that malignant obstruction. Interventional endoscopistsshould be aware and discuss the risk for complications in setting of benign conditions. Indicationsin these cases should be discussed in a multi-disciplinary fashion with colorectal surgery. 展开更多
关键词 Colon cancer OBSTRUCTION MALIGNANCY STRICTURE self-expandable metal stent stent migration
下载PDF
Research on the Status Quo and Optimization of Centralized Procurement of Coronary Stents
6
作者 Zhang Yuting Liu Xiaoxi 《Asian Journal of Social Pharmacy》 2024年第1期20-28,共9页
Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents indust... Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents industry,and to provide suggestions on perfecting procedures to better carry out the centralized procurement of coronary stents.Methods Literature analysis was used to investigate the results of the procurement of coronary stent in a province and a hospital.Results and Conclusion The centralized procurement of coronary stents has alleviated the economic pressure of patients,but it has many problems.Therefore,this paper proposes some suggestions,such as promoting the orderly development of the coronary stent industry,improving the evaluation link of the centralized procurement of coronary stents,adopting the accurate reporting model to ensure the quality of coronary stents and improving the standardization of clinical services. 展开更多
关键词 volume procurement coronary stent medical resource
下载PDF
Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up 被引量:9
7
作者 Ying-Sheng Cheng Fang Ma +5 位作者 Ying-Sheng Cheng Yong-Dong Li Jun-Gong Zhao Chun-Gen Wu Ni-Wei Chen Wei-Xiong Chen 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第40期5111-5117,共7页
AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm ... AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm. 展开更多
关键词 ACHALASIA DYSPHAGIA self-expanding metallic stents COMPARISON
下载PDF
Initial clinical experience with Xpert-Pro peripheral self-expanding stent system for internal carotid artery dissection:Two case reports
8
作者 Ning Li Xinzhao Jiang +1 位作者 Zhora Baghdasaryan Peng Wang 《Journal of Interventional Medicine》 2023年第2期103-106,共4页
Background:The standard treatment for internal carotid artery(ICA)dissection is obscure.Current therapeutic strategies include the use of antiplatelet drugs,anticoagulant drugs,intravenous thrombolysis,and endovascula... Background:The standard treatment for internal carotid artery(ICA)dissection is obscure.Current therapeutic strategies include the use of antiplatelet drugs,anticoagulant drugs,intravenous thrombolysis,and endovascular treatment.Endovascular treatment is important in acute internal carotid artery dissection.This study reports two acute internal carotid artery dissection cases that were treated successfully using the Xpert-Pro peripheral selfexpanding stent system.Case summary:The first case was of a 38-year-old male patient with transient speechlessness and paralysis of the right limb in July 2021.Cervical computed tomographic angiography(CTA)showed ICA occlusion on the left side.Digital subtraction angiography(DSA)showed severe stenosis of the C1 segment of the left internal carotid artery with intermural hematoma.The patient subsequently underwent Xpert-Pro peripheral self-expanding stent implantation,and his condition stabilized.The second case was of a 56-year-old male patient with speechlessness and paralysis of the right limb.Cervical CTA showed a dissected left ICA,and DSA showed an occluded left ICA and middle cerebral artery.The patient subsequently underwent stent implantation,and his condition stabilized. 展开更多
关键词 Internal carotid artery dissection Endovascular treatment stent Case report NEUROLOGY
下载PDF
Management of occluded self-expanding biliary metal stents in malignant biliary disease 被引量:1
9
作者 Simon Nennstiel Isolde Tschurtschenthaler +5 位作者 Bruno Neu Hana Algül Monther Bajbouj Roland M. Schmid Stefan von Delius Andreas Weber 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2018年第1期49-54,共6页
Background: Occlusion of self-expanding metal stents(SEMS) in malignant biliary obstruction occurs in up to 40% of patients. This study aimed to compare the different techniques to resolve stent occlusion in our colle... Background: Occlusion of self-expanding metal stents(SEMS) in malignant biliary obstruction occurs in up to 40% of patients. This study aimed to compare the different techniques to resolve stent occlusion in our collective of patients.Methods: Patients with malignant biliary obstruction and occlusion of biliary metal stent at a tertiary referral endoscopic center were retrospectively identified between April 1, 1994 and May 31, 2014. The clinical records were further analyzed regarding the characteristics of patients, malignant strictures, SEMS,management strategies, stent patency, subsequent interventions, survival time and case charges.Results: A total of 108 patients with biliary metal stent occlusion were identified. Seventy-nine of these patients were eligible for further analysis. Favored management was plastic stent insertion in 73.4% patients. Second SEMS were inserted in 12.7% patients. Percutaneous transhepatic biliary drainage and mechanical cleansing were conducted in a minority of patients. Further analysis showed no statistically significant difference in median overall secondary stent patency(88 vs. 143 days, P = 0.069), median survival time(95 vs. 192 days, P = 0.116), median subsequent intervention rate(53.4% vs. 40.0%, P = 0.501)and median case charge(€5145 vs. €3473, P = 0.803) for the treatment with a second metal stent insertion compared to plastic stent insertion. In patients with survival time of more than three months,significantly more patients treated with plastic stents needed re-interventions than patients treated with second SEMS(93.3% vs. 57.1%, P = 0.037).Conclusions: In malignant biliary strictures, both plastic and metal stent insertions are feasible strategies for the treatment of occluded SEMS. Our data suggest that in palliative biliary stenting, patients especially those with longer expected survival might benefit from second SEMS insertion. Careful patient selection is important to ensure a proper decision for either management strategy. 展开更多
关键词 self-expanding metal stents Biliary tract neoplasms Endoscopic retrograde CHOLANGIOPANCREATOGRAPHY Biliary tract diseases COMPLICATIONS
下载PDF
Evaluation of fully covered self-expanding metal stents in benign biliary strictures and bile leaks 被引量:9
10
作者 David Lalezari Inder Singh +1 位作者 Sofiya Reicher Viktor Ernst Eysselein 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第7期332-339,共8页
AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks... AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks (n=5) from July 2007 to February 2012 that had received placement of fully covered self-expanding metal stents (FCSEMs). Fourteen patients had endoscopic placement of VIABIL (Conmed, Utica, New York, United States) stents and three had Wallflex (Boston Scientific, Mass) stents. FCSEMS were 8 mm or 10 mm in diameter and 4 cm to 10 cm in length. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. FCSEMS were removed after 4 or more weeks. Resolution of BBS and leak was documented cholangiographically following stent removal. Stent patency can be defined as adequate bile and contrast flow from the stent and into the ampulla during endoscopic retrograde cholangiopancreatography (ERCP) without clinical signs and/or symptoms of biliary obstruction. Criterion for bile leak resolution at ERCP is defined as absence of contrast extravasation from the common bile duct, cystic duct remanent, or gall blad-der fossa. Rate of complications such as migration, and instent occlusion were recorded. Failure of endoscopic therapy was defined as persistent biliary stenosis or continuous biliary leakage after 12 mo of stent placement. RESULTS: All 17 patients underwent successful FC- SEMS placement and removal. Etiologies of BBS included: cholecystectomies (n=8), cholelithiasis (n=2), hepatic artery compression (n=1), pancreatitis (n=2), and Whipple procedure (n=1). All bile leaks occurred following cholecystectomy. The anatomic location of BBS varied: distal common bile duct (n=7), common hepatic duct (n=1), hepaticojejunal anastomosis (n=2), right intrahepatic duct (n=1), and choledochoduo-denal anastomatic junction (n=1). All bile leaks were found to be at the cystic duct. Twelve of 17 patients had failed prior stent placement or exchange. Resolution of the biliary strictures and bile leaks was achieved in 16 of 17 patients (94%). The overall median stent time was 63 d (range 27-251 d). The median stent time for the BBS group and bile leak group was 62 ± 58 d (range 27-199 d) and 92 ± 81 d (range 48-251 d), respectively. All 17 patients underwent successful FCSEMS removal. Long term follow-up was obtained for a median of 575 d (range 28-1435 d). Complications occurred in 5 of 17 patients (29%) and included: migration (n=2), stent clogging (n=1), cholangitis (n=1), and sepsis with hepatic abscess (n=1). CONCLUSION: Placement of fully covered self-expanding metal stents may be used in the management of benign biliary strictures and bile leaks with a low rate of complications. 展开更多
关键词 BILE LEAKS Benign BILIARY STRICTURE Fully COVERED metal stents BILIARY disease
下载PDF
Role of self-expanding metal stents in the management ofvariceal haemorrhage:Hype or hope? 被引量:5
11
作者 Brian J Hogan James P O’Beirne 《World Journal of Gastrointestinal Endoscopy》 CAS 2016年第1期23-29,共7页
Despite the advances of medical,endoscopic and radiological therapy over recent years the mortality rates of acute variceal haemorrhage are still 16%-20% and the medium term outcome has not improved in the last 25 yea... Despite the advances of medical,endoscopic and radiological therapy over recent years the mortality rates of acute variceal haemorrhage are still 16%-20% and the medium term outcome has not improved in the last 25 years. Early transjugular intrahepatic portosystemic shunt has proved to be an effective therapy for selected groups of patients with a high risk of re-bleeding and moderate liver disease. However,there is an unmet need for a therapy that can be applied in patients with a high risk of re-bleeding and advanced liver disease either as definitive therapy or as a bridge to permanent therapy. Selfexpanding metal stents can be placed without the need for endoscopic or fluoroscopic control and,once in place,will provide effective haemostasis and allow a route for oral fluids and nutrition. They can remain in place whilst liver function recovers and secondary prophylaxis is initiated. We review the results of 6 case series including a total of 83 patients and the first randomised controlled trial of self-expanding metal stents vs balloon tamponade(BT) in the management of refractory variceal haemorrhage. We report that self-expanding metal stents provide effective haemostasis and perform better than BT in refractory bleeding,where they are associated with fewer complications. Whilst the most effective place for self-expanding metal stents in the management algorithm needs to be determined by further randomised controlled trials,currently they provide an effective alternative to BT in selected patients. 展开更多
关键词 ESOPHAGEAL and gastric VARICES stents Liver cirrhosis GASTROINTESTINAL HAEMORRHAGE Portalhypertension
下载PDF
Self-expanding metal stents for the palliation of malignant gastric outlet obstruction in patients with peritoneal carcinomatosis 被引量:2
12
作者 Christoph Rademacher Matthias Bechtler +3 位作者 Steffen Schneider Bettina Hartmann Johannes Striegel Ralf Jakobs 《World Journal of Gastroenterology》 SCIE CAS 2016年第43期9554-9561,共8页
AIM To evaluate the efficacy of self-expanding metal stents(SEMS) for the palliation of malignant gastric outlet obstruction in patients with and without peritoneal carcinomatosis(PC).METHODS We performed a retrospect... AIM To evaluate the efficacy of self-expanding metal stents(SEMS) for the palliation of malignant gastric outlet obstruction in patients with and without peritoneal carcinomatosis(PC).METHODS We performed a retrospective analysis of 62 patients who underwent SEMS placement for treatment of malignant gastroduodenal obstruction at our hospital over a six-year period. Stents were deployed through the scope under combined fluoroscopic and endoscopic guidance. Technical success was defined as successful stent placement and expansion. Clinical success was defined as an improvement in the obstructive symptoms and discharge from hospital without additional parenteral nutrition. According to carcinomatosis status, patients were assigned into groups with or without evidence of peritoneal disease.RESULTS In most cases, obstruction was caused by pancreatic(47%) or gastric cancer(23%). Technical success was achieved in 96.8%(60/62), clinical success in 79%(49/62) of all patients. Signs of carcinomatosis were identified in 27 patients(43.5%). The diagnosis was confirmed by pathology or previous operation in 7 patients(11.2%) and suspected by CT, MRI or ultrasound in 20 patients(32.2%). Presence of carcinomatosis was associated with a significantly lower clinical success rate compared to patients with no evidence of peritoneal disease(66.7% vs 88.6%, P = 0.036). There was no significant difference in overall survival between patients with or without PC(median 48 d vs 70 d, P = 0.21), but patients showed significantly longer survival after clinical success of SEMS placement compared to those experiencing clinical failure(median 14.5 d vs 75 d, P = 0.0003).CONCLUSION Given the limited therapeutic options and a clinical success rate of at least 66.7%, we believe that SEMS are a reasonable treatment option in patients with malignant gastric outlet obstruction with peritoneal carcinomatosis. 展开更多
关键词 胃的插头阻塞 自我膨胀的金属 stents carcinomatosis 减轻 内视镜检查法
下载PDF
Self-expanding metallic esophageal stents:A long way to go before a particular stent can be recommended 被引量:1
13
作者 Pankaj Jain 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第48期5327-5328,共2页
We agree that the covered self-expanding metal stents (SEMSs) fare better than the uncovered stents as recurrent dysphagia due to tumor ingrowth is common with uncovered stent. Recent American College of Gastroenterol... We agree that the covered self-expanding metal stents (SEMSs) fare better than the uncovered stents as recurrent dysphagia due to tumor ingrowth is common with uncovered stent. Recent American College of Gastroenterology Practice Guideline on the Role of Esophageal Stents in Benign and Malignant Diseases concludes that SEMSs cannot be routinely recommended in conjunction with chemo-radiation. The comparison of ultraflex and choostent in the Italian study found no difference in the palliation of dysphagia, rate of complications and survival rate. 展开更多
关键词 自我膨胀的金属性的食道的 stents 咽下困难 食道的 stents
下载PDF
Successful endoscopic removal of three embedded esophageal self-expanding metal stents
14
作者 Xiao-Qin Liu Min Zhou +4 位作者 Wen-Xin Shi Yi-Ying Qi Hui Liu Bin Li Hong-Wei Xu 《World Journal of Gastrointestinal Endoscopy》 CAS 2017年第9期494-498,共5页
In the report,we describe a case of refractory benign esophageal strictures from esophageal cancer after an operation for the placement of three partially covered self-expanding metal stents (SEMSs),which were all emb... In the report,we describe a case of refractory benign esophageal strictures from esophageal cancer after an operation for the placement of three partially covered self-expanding metal stents (SEMSs),which were all embedded in the esophageal wall.Using the stentin-stent technique,the three embedded SEMSs were successfully removed without significant complications.To the best of our knowledge,few cases of the successful removal of multiple embedded esophageal SEMSs have been reported in the literature.This case also highlights that the stent-in-stent technique is effective for removing multiple embedded esophageal SEMSs. 展开更多
关键词 Esophageal stricture self-expanding metal stent Multiple stent-in-stent GASTROSCOPY
下载PDF
Self-expanding metallic stents drainage for acute proximal colon obstruction 被引量:30
15
作者 Li-Qin Yao Yun-Shi Zhong Mei-Dong Xu Jian-Min Xu Ping-Hong Zhou Xian-Li Cai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第28期3342-3346,共5页
AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery.METHODS: Eighty-one colon (proximal to s... AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery.METHODS: Eighty-one colon (proximal to spleen flex) carcinoma patients (47 males and 34 females,aged 18-94 years,mean = 66.2 years) treated between September 2004 and June 2010 for acute colon obstruction were enrolled to this study,and their clinical and radiological features were reviewed.After a cleaning enema was administered,urgent colonoscopy was performed.Subsequently,endoscopic decompression using SEMS placement was attempted.RESULTS: Endoscopic decompression using SEMS placement was technically successful in 78 (96.3%) of 81 patients.Three patients’ symptoms could not be relieved after SEMS placement and emergent operation was performed 1 d later.The site of obstruction was transverse colon in 18 patients,the hepatic flex in 42,and the ascending colon in 21.Following adequate cleansing of the colon,patients’ abdominal girth was decreased from 88 ± 3 cm before drainage to 72 ± 6 cm 7 d later,and one-stage surgery after 8 ± 1 d (range,7-10 d) was performed.No anastomotic leakage or postoperative stenosis occurred after operation.CONCLUSION: SEMS placement is effective and safe in the management of acute proximal colon obstruction due to colon carcinoma,and is considered as a bridged method before curative surgery. 展开更多
关键词 金属支架 肠阻塞 急性 SEMS 引流 结肠癌 安全管理 桥接方法
下载PDF
Double layered self-expanding metal stents for malignant esophageal obstruction, especially across the gastroesophageal junction 被引量:5
16
作者 Min Dae Kim Su Bum Park +5 位作者 Dae Hwan Kang Jae Hyung Lee Cheol Woong Choi Hyung Wook Kim Chung Uk Chung Young Il Jeong 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第28期3732-3737,共6页
AIM: To evaluate the clinical outcomes of double-layered self-expanding metal stents (SEMS) for treatment of malignant esophageal obstruction according to whether SEMS crosses the gastroesophageal junction (GEJ). METH... AIM: To evaluate the clinical outcomes of double-layered self-expanding metal stents (SEMS) for treatment of malignant esophageal obstruction according to whether SEMS crosses the gastroesophageal junction (GEJ). METHODS: Forty eight patients who underwent the SEMS insertion for malignant esophageal obstruction were enrolled. Patients were classified as GEJ group (SEMS across GEJ, 18 patients) and non-GEJ group (SEMS above GEJ, 30 patients) according to SEMS position. Double layered (outer uncovered and inner covered stent) esophageal stents were placed. RESULTS: The SEMS insertion and the clinical improvement were achieved in all patients in both groups. Stent malfunction occurred in seven patients in the GEJ group and nine patients in the non-GEJ group. Tumor overgrowth occurred in five and eight patients, respectively, food impaction occurred in one patient in each group, and stent migration occurred in one and no patient, respectively. There were no significant differences between the two groups. Reflux esophagitis occurred more frequently in the GEJ group (eight vs five patients, P = 0.036) and was controlled by proton pump inhibitor. Aspiration pneumonia occurred in zero and five patients, respectively, and tracheoesophageal fistula occurred in zero and two patients, respectively. CONCLUSION: Double-layered SEMS are a feasible and effective treatment when placed across the GEJ for malignant esophageal obstruction. Double-layered SEMS provide acceptable complications, especially migration, although reflux esophagitis is more common in the GEJ group. 展开更多
关键词 金属支架 交界处 食管 梗阻 恶性 治疗 SEMS 质子泵抑制剂
下载PDF
Role of self-expanding metal stents in patients with malignant colorectal obstruction: A systematic review and meta-analysis
17
作者 Nirav Thosani Subhas Banerjee +4 位作者 Vikesh Khanijow Bhavana Rao Priyanka Priyanka Atilla Ertan Sushovan Guha 《World Journal of Meta-Analysis》 2015年第6期232-253,共22页
AIM: To assess the safety and efficacy of self-expandable metal stents(SEMSs) for malignant colorectal obstruction. METHODS: Data regarding technical success, clinical success, and procedure related complications were... AIM: To assess the safety and efficacy of self-expandable metal stents(SEMSs) for malignant colorectal obstruction. METHODS: Data regarding technical success, clinical success, and procedure related complications were collected from included studies. Der Simonian-Laird random effects model was used to generate the overall outcome. Thirty international studies with a total of 2058 patients with malignant colorectal obstruction were included. RESULTS: The technical and clinical success rates for SEMS placement were 94%(95%CI: 92-96) and 91%(95%CI: 88-93), respectively. Overall complication rate for SEMS was 23%(95%CI: 18-29). Stent migration8%(95%CI: 6-10) and stent obstruction 8%(95%CI: 6-11) were the most common complications, followed by perforation 5%(95%CI: 4%-7%). Surgical or endoscopic re-interventions were needed in 14%(95%CI: 10-18) of patients. Endoscopic repeat stent placement was required in 8%(95%CI: 6-10), while surgical intervention was needed in 6%(95%CI: 4-8).CONCLUSION: SEMS are effective when used as palliation or bridge to surgery for malignant colorectal obstruction with high technical and clinical success. About 14% of patients require repeat endoscopic or surgical intervention for stent failure or to manage stent related complications. 展开更多
关键词 Metal stent COLORECTAL CANCER Colon CANCER RECTAL CANCER Intestinal OBSTRUCTION Bowel OBSTRUCTION MALIGNANT OBSTRUCTION COLONIC OBSTRUCTION
下载PDF
A new approach to endoscopic treatment of tumors of the esophagogastric junction with individually designed self-expanding metal stents 被引量:1
18
作者 Serhat Aymaz Arno J Dormann 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第24期3919-3921,共3页
The incidence of adenocarcinoma of the esophago-gastric junction is constantly increasing. Curative treatment is no longer possible at the time of diagnosis in more than 50% of patients with esophageal carcinoma,and p... The incidence of adenocarcinoma of the esophago-gastric junction is constantly increasing. Curative treatment is no longer possible at the time of diagnosis in more than 50% of patients with esophageal carcinoma,and palliative treatment focusing on eliminating dysphagia is required. Endoscopic therapy with stent implantation is an established method of achieving this. It can be carried out quickly,with a low rate of early complications,and leads to fast symptomatic improvement,assessed using the dysphagia score. The relatively high rate of late complications such as stent migration,hemorrhage,and gastroesophageal mucosal prolapse has led to recent debate on the role of metal stents in palliative therapy. We present here a new type of stent design for transcardial application,which is intended to prevent bleeding due to mechanical mucosal lesions caused by the distal end of the stent extending into the stomach. The further intention of this case report is to force the discussion on individually designed nitinol stents in special anatomic conditions. 展开更多
关键词 食道癌 治疗方法 内窥镜检查 症状
下载PDF
Drug-eluting fully covered self-expanding metal stent for dissolution of bile duct stones in vitro 被引量:6
19
作者 Chao Huang Xiao-Bo Cai +3 位作者 Li-Li Guo Xiao-Sheng Qi Qiang Gao Xin-Jian Wan 《World Journal of Gastroenterology》 SCIE CAS 2019年第26期3370-3379,共10页
BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic... BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic retrograde cholangiopancreatography.Fully covered self-expanding metal stent(FCSEMS)has gained increasing attention in the management of difficult CBDS.AIM To manufacture a drug-eluting FCSEMS,which can achieve controlled release of stone-dissolving agents and speed up the dissolution of CBDS.METHODS Customized covered nitinol stents were adopted.Sodium cholate(SC)and disodium ethylene diamine tetraacetic acid(EDTA disodium,EDTA for short)were used as stone-dissolving agents.Three different types of drug-eluting stents were manufactured by dip coating(Stent I),coaxial electrospinning(Stent II),and dip coating combined with electrospinning(Stent III),respectively.The drugrelease behavior and stone-dissolving efficacy of these stents were evaluated in vitro to sort out the best manufacturing method.And the selected stonedissolving stents were further put into porcine CBD to evaluate their biosecurity.RESULTS Stent I and Stent II had obvious burst release of drugs in the first 5 d while Stent III presented controlled and sustainable drug release for 30 d.In still buffer,the final stone mass-loss rate of each group was 5.19%±0.69%for naked FCSEMS,20.37%±2.13%for Stent I,24.57%±1.45%for Stent II,and 33.72%±0.67%for Stent III.In flowing bile,the final stone mass-loss rate of each group was 5.87%±0.25%for naked FCSEMS,6.36%±0.48%for Stent I,6.38%±0.37%for Stent II,and 8.15%±0.27%for Stent III.Stent III caused the most stone mass-loss no matter in still buffer or in flowing bile,which was significantly higher than those of other groups(P<0.05).In vivo,Stent III made no difference from naked FCSEMS in serological analysis(P>0.05)and histopathological examination(P>0.05).CONCLUSION The novel SC and EDTA-eluting FCSEMS is efficient in diminishing CBDS in vitro.When conventional endoscopic techniques fail to remove difficult CBDS,SC and EDTA-eluting FCSEMS implantation may be considered a promising alternative. 展开更多
关键词 Common BILE duct stone DRUG-ELUTING stent Fully COVERED self-expanding metal stent Electrospinning NANOFIBER film
下载PDF
Association of Comorbid Asthma and the Efficacy of Bioabsorbable Steroid-eluting Sinus Stents Implanted After Endoscopic Sinus Surgery in Patients with Chronic Rhinosinusitis with Nasal Polyps 被引量:1
20
作者 Ao HUANG Tao LI +6 位作者 Min-shan LI Zhen-xiao HUANG De-hui WANG Lei CHENG Bing ZHOU Heng WANG Zheng LIU 《Current Medical Science》 SCIE CAS 2023年第5期1005-1012,共8页
Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed ... Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed a post-hoc analysis of a randomized self-controlled clinical trial on post-operative implantation of bioabsorbable steroid-eluting stents in patients with CRSwNP.Univariate logistic regression analysis was conducted to identify which of the following factors affect the response to post-operative stent implantation:sex,serum eosinophil levels,history of prior surgery,endoscopic scores,and comorbid conditions(asthma and allergic rhinitis).The primary outcome was the rate of post-operative intervention on day 30,and the secondary outcome was the rate of polypoid tissue formation(grades 2–3)on days 14,30,and 90.Results A total of 151 patients with CRSwNP were included in the post-hoc analysis.Asthma was identified as the only risk factor for a poor response to steroid-eluting sinus stents on post-operative day 30,with an odds ratio of 23.71(95%CI,2.81,200.16;P=0.004)for the need for post-operative intervention and 19(95%CI,2.20,164.16;P=0.003)for moderate-to-severe polypoid tissue formation.In addition,the asthmatic group showed higher rates of post-operative intervention and polypoid tissue formation than the non-asthmatic group on post-operative day 30.Blood eosinophil levels were not identified as a risk factor for poor outcomes after stent implantation.Conclusion Comorbid asthma,but not blood eosinophil level,impairs the efficacy of steroid-eluting sinus stents in the short term after ESS in patients with CRSwNP. 展开更多
关键词 chronic rhinosinusitis ASTHMA nasal polyps outcome steroid-eluting sinus stent
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部