Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
This paper expounds the main structure design and function implementation of a provincial power grid relay protection setting calculation integration system. In accordance with the actual features of the relay protect...This paper expounds the main structure design and function implementation of a provincial power grid relay protection setting calculation integration system. In accordance with the actual features of the relay protection setting calculation work, setting calculation system is developed based on the project. For the development and research of integration of setting calculation system, to achieve a certain provincial power grid relay protection setting calculation and the standardization of the operation and management, network and intelligent, is of great significance.展开更多
对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1...对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。展开更多
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
文摘This paper expounds the main structure design and function implementation of a provincial power grid relay protection setting calculation integration system. In accordance with the actual features of the relay protection setting calculation work, setting calculation system is developed based on the project. For the development and research of integration of setting calculation system, to achieve a certain provincial power grid relay protection setting calculation and the standardization of the operation and management, network and intelligent, is of great significance.
文摘对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。