According to the theoretical analysis and calculation on the base ofcontinuous mass system, the simulation experimental investigation on active control of torsionalvibration in a turbogenerator shaft system is conduct...According to the theoretical analysis and calculation on the base ofcontinuous mass system, the simulation experimental investigation on active control of torsionalvibration in a turbogenerator shaft system is conducted. A test installation with the excitation ofgenerator motor and multi-stepped shaft system is established to simulate the torsional vibration ofa turbogenerator rotor shaft system, and to examine the active control strategy presented. Someuseful results are reached in the experimental study.展开更多
The dynamic performance of the coupling shaft system in a carpet tufting machine is the most critical factor affecting the carpet tufting machine's efficiency,and the product quality of the tufted carpet. To deter...The dynamic performance of the coupling shaft system in a carpet tufting machine is the most critical factor affecting the carpet tufting machine's efficiency,and the product quality of the tufted carpet. To determine how to avoid resonance produced by the coupling shaft system's vibration during the weaving process,the dynamic performance of a coupling shaft system in a carpet tufting machine was analyzed. Focusing on a DHGN801D-400 carpet tufting machine,a dynamic model of coupling shaft system was established by utilizing transfer matrix methodology. On the basis of this model,the natural frequencies and mode shapes of the coupling shaft system were obtained through simulations. The correctness of the theoretical model and the dynamic performance of the coupling shaft system were validated by experiments. The first order natural frequency of the coupling shaft system was close to 600 r / min. A conclusion can thus be drawn that operating the carpet tufting machine near this speed should be avoided as much as possible.展开更多
In this study,the coupled torsional-transverse vibration of a propeller shaft system owing to the misalignment caused by the shaft rotation was investigated.The proposed numerical model is based on the modified versio...In this study,the coupled torsional-transverse vibration of a propeller shaft system owing to the misalignment caused by the shaft rotation was investigated.The proposed numerical model is based on the modified version of the Jeffcott rotor model.The equation of motion describing the harmonic vibrations of the system was obtained using the Euler-Lagrange equations for the associated energy functional.Experiments considering different rotation speeds and axial loads acting on the propulsion shaft system were performed to verify the numerical model.The effects of system parameters such as shaft length and diameter,stiffness and damping coefficients,and cross-section eccentricity were also studied.The cross-section eccentricity increased the displacement response,yet coupled vibrations were not initially observed.With the increase in the eccentricity,the interaction between two vibration modes became apparent,and the agreement between numerical predictions and experimental measurements improved.Given the results,the modified version of the Jeffcott rotor model can represent the coupled torsional-transverse vibration of propulsion shaft systems.展开更多
The stability and nonlinear dynamic behavior of drilling shaft system in copper stave deep hole drilling were analyzed. The effects of the fluctuation of the cutting force, the mass eccentricity and the hydrodynamic f...The stability and nonlinear dynamic behavior of drilling shaft system in copper stave deep hole drilling were analyzed. The effects of the fluctuation of the cutting force, the mass eccentricity and the hydrodynamic forces of cutting fluid could be taken into consideration in the model of drilling shaft system. Based on the isoparametric finite element method, the variational form of Reynolds equation in hydrodynamic fluid was used to calculate nonlinear hydrodynamic forces and their Jacobian matrices simultaneously. In the stability analysis, a new shooting method for rapidly determining the periodic orbit of the nonlinear drilling shaft system and its period was presented by rebuilding the traditional shooting method and changing the time scale. Through the combination of theories with experiment, the correctness and effectiveness of the above methods are verified by using the Floquet theory. The results show that the mass eccentricity can inhibit the whirling motion of drilling shaft to some extent.展开更多
Aiming at providing with high-load capability in active vibration control of large-scale rotor system, a new type of active actuator to simultaneously reduce the dangers of low frequency flexural and torsional vibrati...Aiming at providing with high-load capability in active vibration control of large-scale rotor system, a new type of active actuator to simultaneously reduce the dangers of low frequency flexural and torsional vibrations is designed. The actuator employs electro-hydraulic system and can provide a high and circumferential load. To initialize new research, the characteristics of various kinds of active actuators to control rotor shaft vibration are briefly introduced. The purpose of this paper is to introduce the preliminary results via presenting the structure, functions and operating principles, in particular, the working process of the electro-hydraulic system of the new actuator which includes a set of high speed electromagnetic valves and a series of sloping cone-shaped openings, and presenting the transmission relationships among the control parameters from control signals into the valves to active load onto shaft. The course of the work is dynamic, and a series of spatial forces and moments are put on the shaft to get an external resultant force to reduce excitations that induce vibration of shafts. By checking states of vibration, the actuator can control the impulse width and the interval of injection time for applying different control force to a vibration shaft in two circumference directions through the regulating action of a set of combination directional control valves. The results from simulating analysis and experiment show evidence of that this design can satisfy the case of active process of decreasing of flexural and torsional vibrations.展开更多
1.IntroductionWith the increase of the capacity of the turbine generator set,the safety of the shaft system of the set(including the exciter)isthreatened for the following three reasons:1.The length of the shaft syste...1.IntroductionWith the increase of the capacity of the turbine generator set,the safety of the shaft system of the set(including the exciter)isthreatened for the following three reasons:1.The length of the shaft system increases.The length of theshaft system is 15 m for a 50 MW set,32-40 m for a 300 MW set and90 m for a 900 MW nuclear power set.The increased number of theconcentrated masses leads to the increase of both the number of展开更多
BACKGROUND Whether operation is superior to non-operation for humeral shaft fracture remains debatable.We hypothesized that operation could decrease the nonunion and reintervention rates and increase the functional ou...BACKGROUND Whether operation is superior to non-operation for humeral shaft fracture remains debatable.We hypothesized that operation could decrease the nonunion and reintervention rates and increase the functional outcomes.AIM To compare the clinical efficacy between operative and nonoperative approaches for humeral shaft fractures.METHODS We searched the PubMed,Web of Science,ScienceDirect,and Cochrane databases from 1990 to December 2023 for clinical trials and cohort studies comparing the effects of operative and conservative methods on humeral shaft fractures.Two investigators independently extracted data from the eligible studies,and the other two assessed the methodological quality of each study.The quality of the included studies was assessed using the Cochrane risk bias or Newcastle-Ottawa Scale.The nonunion,reintervention and the overall complications and functional scores were pooled and analyzed using Review Manager software(version 5.3).RESULTS A total of four randomized control trials and 13 cohort studies were included,with 1285 and 1346 patients in the operative and nonoperative groups,respectively.Patients in the operative group were treated with a plate or nail,whereas those in the conservative group were managed with splint or functional bracing.Four studies were assessed as having a high risk of bias,and the other 13 were of a low risk of bias according to the Newcastle-Ottawa Scale or Cochrane risk bias tool.The operative group had a significantly decreased rate of nonunion[odds ratio(OR)0.30;95%CI:0.23 to 0.40,reintervention(OR:0.33;95%CI:0.24 to 0.47),and overall complications(OR:0.62;95%CI:0.49 to 0.78)].The pooled effect of the Disabilities of Arm,Shoulder,and Hand score showed a significant difference at 3[mean difference(MD)-8.26;95%CI:-13.60 to-2.92],6(MD:-6.72;95%CI:-11.34 to-2.10),and 12 months(MD:-2.55;95%CI:-4.36 to-0.74).The pooled effect of Visual Analog Scale scores and the Constant-Murley score did not significantly differ between the two groups.CONCLUSION This systematic review and meta-analysis revealed a trend of rapid functional recovery and decreased rates of nonunion and reintervention after operation for humeral shaft fracture compared to conservative treatment.展开更多
Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current rev...Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current review aims to compare the outcomes of adult tibia fractures treated with solid nails to those treated with hollow nails. Methods: A search on Scopus, PubMed, and Cochrane Library, using three keywords (Outcome, Tibia shaft fractures, Nail) was conducted in April 2023. Results were compiled and two independent reviewers screened and selected eligible articles After removing duplicates, titles and abstracts were read to exclude ineligible studies. Full-text articles of the remaining papers were read to select eligible studies which were further critically appraised to ascertain their methodological quality. The data extracted from the selected papers were synthesized using a combination of pooling of results, tests of statistical difference (t-test and chi-square) and narrative synthesis methods. Results: A total of 2295 articles were obtained from the databases and citation searching. A total of 9 papers were identified as eligible and included in the review. Findings revealed that there is no statistical difference in the outcomes of tibia fractures treated with either solid or hollow nail groups such as duration of surgery (p = 0.541), rate of delayed and non-union (p = 0.342), and rate of surgical site infections (p = 0.395). Conclusion: Intramedullary nailing of tibia shaft fractures with either solid or hollow nails have similar functional outcomes.展开更多
Linked tetra shaft and double cantilever flat flap gate is a new type of structure in water conservancy projects,but the traditional method is now adopted in its design.In order to the application and dissemination ...Linked tetra shaft and double cantilever flat flap gate is a new type of structure in water conservancy projects,but the traditional method is now adopted in its design.In order to the application and dissemination of the type of sluice,this paper researches the difficult points of design advance,through researching the motion locus & stress coundition of linked tetra shaft system.The writer will build up the mathmatical model and handle it with the computer.Thus,we can achieve the modern desing on the basis of the software of linked tetra shaft system development.展开更多
Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change tradi...Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.展开更多
The crack fault is one of the most common faults in the rotor system,and researchers have paid close attention to its fault diagnosis.However,most studies focus on discussing the dynamic response characteristics cause...The crack fault is one of the most common faults in the rotor system,and researchers have paid close attention to its fault diagnosis.However,most studies focus on discussing the dynamic response characteristics caused by the crack rather than estimating the crack depth and position based on the obtained vibration signals.In this paper,a novel crack fault diagnosis and location method for a dual-disk hollow shaft rotor system based on the Radial basis function(RBF)network and Pattern recognition neural network(PRNN)is presented.Firstly,a rotor system model with a breathing crack suitable for a short-thick hollow shaft rotor is established based on the finite element method,where the crack's periodic opening and closing pattern and different degrees of crack depth are considered.Then,the dynamic response is obtained by the harmonic balance method.By adjusting the crack parameters,the dynamic characteristics related to the crack depth and position are analyzed through the amplitude-frequency responses and waterfall plots.The analysis results show that the first critical speed,first subcritical speed,first critical speed amplitude,and super-harmonic resonance peak at the first subcritical speed can be utilized for the crack fault diagnosis.Based on this,the RBF network and PRNN are adopted to determine the depth and approximate location of the crack respectively by taking the above dynamic characteristics as input.Test results show that the proposed method has high fault diagnosis accuracy.This research proposes a crack detection method adequate for the hollow shaft rotor system,where the crack depth and position are both unknown.展开更多
Aiming at the shortcomings of traditional contact measurement methods such as low measurement efficiency,high cost and low accuracy,a non-contact optical measurement method based on the laser displacement sensor is pr...Aiming at the shortcomings of traditional contact measurement methods such as low measurement efficiency,high cost and low accuracy,a non-contact optical measurement method based on the laser displacement sensor is proposed.According to the relevant regulations of the coaxiality error evaluation standard and the structural characteristics of the compound gear shaft,we have designed and built a set of supporting software system as well as a hardware test platform.In this paper,the distance difference threshold and scale threshold methods are used to eliminate outlier data.The least squares circle is selected to calculate the center of the circle and the minimum containment cylinder axis method is used as the reference axis of the composite gear shaft.Compensated by the standard step shaft calibration,the coaxiality error of the composite gear shaft can be measured to be within 0.01 mm in less than two minutes.The range value of the multi-section measurement test is 0.065 mm.The average coaxiality error is∅0.476 mm.展开更多
Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change tradi...Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with the measurement software. The laser alignment system with dual PSDs was improved on a single PSD system,and it gets higher measurement accuracy than the previous design,and it has been succeeded in designing and implement for actual shaft alignment. In the system,the range of offset measurement is ±4 mm,and the resolution is 1.5 μm,and the accuracy is less than 2 μm.展开更多
Efficiently modulating the velocity distribution and flow pattern of non-Newtonian fluids is a critical challenge in the context of dual shaft eccentric mixers for process intensification,posing a significant barrier ...Efficiently modulating the velocity distribution and flow pattern of non-Newtonian fluids is a critical challenge in the context of dual shaft eccentric mixers for process intensification,posing a significant barrier for the existing technologies.Accordingly,this work reports a convenient strategy that changes the kinetic energy to controllably regulate the flow patterns from radial flow to axial flow.Results showed that the desired velocity distribution and flow patterns could be effectively obtained by varying the number and structure of baffles to change kinetic energy,and a more uniform velocity distribution,which could not be reached normally in standard baffle dual shaft mixers,was easily obtained.Furthermore,a comparative analysis of velocity and shear rate distributions is employed to elucidate the mechanism behind the generation of flow patterns in various dual-shaft eccentric mixers.Importantly,there is little difference in the power number of the laminar flow at the same Reynolds number,meaning that the baffle type has no effect on the power consumption,while the power number of both unbaffle and U-shaped baffle mixing systems decreases compared with the standard baffle mixing system in the transition flow.Finally,at the same rotational condition,the dimensionless mixing time of the U-shaped baffle mixing system is 15.3%and 7.9%shorter than that of the standard baffle and the unbaffle mixing system,respectively,which shows the advantage of the U-shaped baffle in stirring rate.展开更多
In this study, the influence of geometrical parameters on the curve veering phenomenon in a tor-sional system with stepped shaft is investigated. Three approximate solutions including finite el-ement, Rayleigh-Ritz an...In this study, the influence of geometrical parameters on the curve veering phenomenon in a tor-sional system with stepped shaft is investigated. Three approximate solutions including finite el-ement, Rayleigh-Ritz and discretization methods, along with an exact solution are employed to obtain the natural frequencies of the structure. The study reveals that, under specific circumstances, the results obtained by approximate methods are very close to the exact solution. The curve veering behavior is manifested irrespective of the method employed. It is concluded that for the structure studied the curve veering behavior is not because of the approximate techniques used to compute the natural frequencies, and is an inherent behavior of the structure.展开更多
Carbon fiber composites,characterized by their high specific strength and low weight,are becoming increasingly crucial in automotive lightweighting.However,current research primarily emphasizes layer count and orienta...Carbon fiber composites,characterized by their high specific strength and low weight,are becoming increasingly crucial in automotive lightweighting.However,current research primarily emphasizes layer count and orientation,often neglecting the potential of microstructural design,constraints in the layup process,and performance reliability.This study,therefore,introduces a multiscale reliability-based design optimization method for carbon fiber-reinforced plastic(CFRP)drive shafts.Initially,parametric modeling of the microscale cell was performed,and its elastic performance parameters were predicted using two homogenization methods,examining the impact of fluctuations in microscale cell parameters on composite material performance.A finite element model of the CFRP drive shaft was then constructed,achieving parameter transfer between microscale and macroscale through Python programming.This enabled an investigation into the influence of both micro and macro design parameters on the CFRP drive shaft’s performance.The Multi-Objective Particle Swarm Optimization(MOPSO)algorithm was enhanced for particle generation and updating strategies,facilitating the resolution of multi-objective reliability optimization problems,including composite material layup process constraints.Case studies demonstrated that this approach leads to over 30%weight reduction in CFRP drive shafts compared to metallic counterparts while satisfying reliability requirements and offering insights for the lightweight design of other vehicle components.展开更多
In 2023,pivotal advancements in artificial intelligence(AI)have significantly experienced.With that in mind,traditional methodologies,notably the p-y approach,have struggled to accurately model the complex,nonlinear s...In 2023,pivotal advancements in artificial intelligence(AI)have significantly experienced.With that in mind,traditional methodologies,notably the p-y approach,have struggled to accurately model the complex,nonlinear soil-structure interactions of laterally loaded large-diameter drilled shafts.This study undertakes a rigorous evaluation of machine learning(ML)and deep learning(DL)techniques,offering a comprehensive review of their application in addressing this geotechnical challenge.A thorough review and comparative analysis have been carried out to investigate various AI models such as artificial neural networks(ANNs),relevance vector machines(RVMs),and least squares support vector machines(LSSVMs).It was found that despite ML approaches outperforming classic methods in predicting the lateral behavior of piles,their‘black box'nature and reliance only on a data-driven approach made their results showcase statistical robustness rather than clear geotechnical insights,a fact underscored by the mathematical equations derived from these studies.Furthermore,the research identified a gap in the availability of drilled shaft datasets,limiting the extendibility of current findings to large-diameter piles.An extensive dataset,compiled from a series of lateral loading tests on free-head drilled shaft with varying properties and geometries,was introduced to bridge this gap.The paper concluded with a direction for future research,proposes the integration of physics-informed neural networks(PINNs),combining data-driven models with fundamental geotechnical principles to improve both the interpretability and predictive accuracy of AI applications in geotechnical engineering,marking a novel contribution to the field.展开更多
Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is...Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.展开更多
A new short-term warning and integrity monitoring algorithm was proposed for coal mine shaft safety. The Kalman filter (KF) model was used to extract real global positioning system (GPS) kinematic deformation informat...A new short-term warning and integrity monitoring algorithm was proposed for coal mine shaft safety. The Kalman filter (KF) model was used to extract real global positioning system (GPS) kinematic deformation information. The short-term warning model was built by using the two-side cumulative sum (CUSUM) test, which further improves the warning system reliability. Availability (the minimum warning deformation, MWD), false alarm rate (the average run length, ARL), missed rate (the warning delay, WD) and the relationships among them were analyzed and the method choosing warning parameters is given. A test of a deformation simulation platform shows that the warning algorithm can be effectively used for steep deformation warning. A field experiment of the Malan mine shaft in Shanxi coal area illustrates that the proposed algorithm can detect small dynamic changes and the corresponding occurring time. At given warning thresholds (MWD is 15 mm and ARL is 1000),the detected deformations of two consecutive days’ deformation sequences with the algorithm occur at the 705th epoch (705 s) and the 517th epoch (517 s), respectively.展开更多
The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperature...The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperatures below the tunnel ceiling reduce rapidly along the longitudinal towards the tunnel exits. A noticeable temperature stratification is observed near the fire source.Most fire smoke is exhausted out of the shafts while the number of the smoke shafts in the downstream is more than that in the upstream.Large eddy simulation LES based on computational fluid dynamics CFD is carried out using the fire dynamics simulator FDS software with parallel processing in which the grid size of the fire-domain is set to be 0.083 m.The simulation results of temperatures under the ceiling the smoke fronts and the shafts'smoke exhaust or air supply agree reasonably with the experimental data. Further simulations indicate that the decreasing ambient temperature or shaft spacing might reduce smoke temperatures under the tunnel ceiling and increase mass flow rates out of the shafts.This study provides technical scientific evidence and supports for the design and construction of such kinds of tunnels.展开更多
基金This project is supported by National Natural Science Foundation of China (No.59575015) Education Ministry of China.
文摘According to the theoretical analysis and calculation on the base ofcontinuous mass system, the simulation experimental investigation on active control of torsionalvibration in a turbogenerator shaft system is conducted. A test installation with the excitation ofgenerator motor and multi-stepped shaft system is established to simulate the torsional vibration ofa turbogenerator rotor shaft system, and to examine the active control strategy presented. Someuseful results are reached in the experimental study.
基金National Natural Science Foundation of China(No.51175075)the Research and Innovation Project of Shanghai Municipal Education Commission,China(No.15ZZ034)
文摘The dynamic performance of the coupling shaft system in a carpet tufting machine is the most critical factor affecting the carpet tufting machine's efficiency,and the product quality of the tufted carpet. To determine how to avoid resonance produced by the coupling shaft system's vibration during the weaving process,the dynamic performance of a coupling shaft system in a carpet tufting machine was analyzed. Focusing on a DHGN801D-400 carpet tufting machine,a dynamic model of coupling shaft system was established by utilizing transfer matrix methodology. On the basis of this model,the natural frequencies and mode shapes of the coupling shaft system were obtained through simulations. The correctness of the theoretical model and the dynamic performance of the coupling shaft system were validated by experiments. The first order natural frequency of the coupling shaft system was close to 600 r / min. A conclusion can thus be drawn that operating the carpet tufting machine near this speed should be avoided as much as possible.
基金supported by the Scientific and Technological Research Council of Turkey(TUBITAK)2214-A International Doctoral Research Fellowship Programmewhile experiments were performed at the Wuhan University of Technology。
文摘In this study,the coupled torsional-transverse vibration of a propeller shaft system owing to the misalignment caused by the shaft rotation was investigated.The proposed numerical model is based on the modified version of the Jeffcott rotor model.The equation of motion describing the harmonic vibrations of the system was obtained using the Euler-Lagrange equations for the associated energy functional.Experiments considering different rotation speeds and axial loads acting on the propulsion shaft system were performed to verify the numerical model.The effects of system parameters such as shaft length and diameter,stiffness and damping coefficients,and cross-section eccentricity were also studied.The cross-section eccentricity increased the displacement response,yet coupled vibrations were not initially observed.With the increase in the eccentricity,the interaction between two vibration modes became apparent,and the agreement between numerical predictions and experimental measurements improved.Given the results,the modified version of the Jeffcott rotor model can represent the coupled torsional-transverse vibration of propulsion shaft systems.
基金Project(2007CB707706) supported by the Major State Basic Research Development Program of ChinaProjects(2007E213,2007E203) supported by the Natural Science Foundation of Shaanxi Province,China
文摘The stability and nonlinear dynamic behavior of drilling shaft system in copper stave deep hole drilling were analyzed. The effects of the fluctuation of the cutting force, the mass eccentricity and the hydrodynamic forces of cutting fluid could be taken into consideration in the model of drilling shaft system. Based on the isoparametric finite element method, the variational form of Reynolds equation in hydrodynamic fluid was used to calculate nonlinear hydrodynamic forces and their Jacobian matrices simultaneously. In the stability analysis, a new shooting method for rapidly determining the periodic orbit of the nonlinear drilling shaft system and its period was presented by rebuilding the traditional shooting method and changing the time scale. Through the combination of theories with experiment, the correctness and effectiveness of the above methods are verified by using the Floquet theory. The results show that the mass eccentricity can inhibit the whirling motion of drilling shaft to some extent.
基金supported by National Natural Science Foundation of China (No.50475112)National Hi-Tech Research and Development Program of China (863 Program,No.2006AA110112).
文摘Aiming at providing with high-load capability in active vibration control of large-scale rotor system, a new type of active actuator to simultaneously reduce the dangers of low frequency flexural and torsional vibrations is designed. The actuator employs electro-hydraulic system and can provide a high and circumferential load. To initialize new research, the characteristics of various kinds of active actuators to control rotor shaft vibration are briefly introduced. The purpose of this paper is to introduce the preliminary results via presenting the structure, functions and operating principles, in particular, the working process of the electro-hydraulic system of the new actuator which includes a set of high speed electromagnetic valves and a series of sloping cone-shaped openings, and presenting the transmission relationships among the control parameters from control signals into the valves to active load onto shaft. The course of the work is dynamic, and a series of spatial forces and moments are put on the shaft to get an external resultant force to reduce excitations that induce vibration of shafts. By checking states of vibration, the actuator can control the impulse width and the interval of injection time for applying different control force to a vibration shaft in two circumference directions through the regulating action of a set of combination directional control valves. The results from simulating analysis and experiment show evidence of that this design can satisfy the case of active process of decreasing of flexural and torsional vibrations.
文摘1.IntroductionWith the increase of the capacity of the turbine generator set,the safety of the shaft system of the set(including the exciter)isthreatened for the following three reasons:1.The length of the shaft system increases.The length of theshaft system is 15 m for a 50 MW set,32-40 m for a 300 MW set and90 m for a 900 MW nuclear power set.The increased number of theconcentrated masses leads to the increase of both the number of
基金Supported by Natural Science Foundation of Chongqing,China,No.CSTB2023NSCQ-MSX1080.
文摘BACKGROUND Whether operation is superior to non-operation for humeral shaft fracture remains debatable.We hypothesized that operation could decrease the nonunion and reintervention rates and increase the functional outcomes.AIM To compare the clinical efficacy between operative and nonoperative approaches for humeral shaft fractures.METHODS We searched the PubMed,Web of Science,ScienceDirect,and Cochrane databases from 1990 to December 2023 for clinical trials and cohort studies comparing the effects of operative and conservative methods on humeral shaft fractures.Two investigators independently extracted data from the eligible studies,and the other two assessed the methodological quality of each study.The quality of the included studies was assessed using the Cochrane risk bias or Newcastle-Ottawa Scale.The nonunion,reintervention and the overall complications and functional scores were pooled and analyzed using Review Manager software(version 5.3).RESULTS A total of four randomized control trials and 13 cohort studies were included,with 1285 and 1346 patients in the operative and nonoperative groups,respectively.Patients in the operative group were treated with a plate or nail,whereas those in the conservative group were managed with splint or functional bracing.Four studies were assessed as having a high risk of bias,and the other 13 were of a low risk of bias according to the Newcastle-Ottawa Scale or Cochrane risk bias tool.The operative group had a significantly decreased rate of nonunion[odds ratio(OR)0.30;95%CI:0.23 to 0.40,reintervention(OR:0.33;95%CI:0.24 to 0.47),and overall complications(OR:0.62;95%CI:0.49 to 0.78)].The pooled effect of the Disabilities of Arm,Shoulder,and Hand score showed a significant difference at 3[mean difference(MD)-8.26;95%CI:-13.60 to-2.92],6(MD:-6.72;95%CI:-11.34 to-2.10),and 12 months(MD:-2.55;95%CI:-4.36 to-0.74).The pooled effect of Visual Analog Scale scores and the Constant-Murley score did not significantly differ between the two groups.CONCLUSION This systematic review and meta-analysis revealed a trend of rapid functional recovery and decreased rates of nonunion and reintervention after operation for humeral shaft fracture compared to conservative treatment.
文摘Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current review aims to compare the outcomes of adult tibia fractures treated with solid nails to those treated with hollow nails. Methods: A search on Scopus, PubMed, and Cochrane Library, using three keywords (Outcome, Tibia shaft fractures, Nail) was conducted in April 2023. Results were compiled and two independent reviewers screened and selected eligible articles After removing duplicates, titles and abstracts were read to exclude ineligible studies. Full-text articles of the remaining papers were read to select eligible studies which were further critically appraised to ascertain their methodological quality. The data extracted from the selected papers were synthesized using a combination of pooling of results, tests of statistical difference (t-test and chi-square) and narrative synthesis methods. Results: A total of 2295 articles were obtained from the databases and citation searching. A total of 9 papers were identified as eligible and included in the review. Findings revealed that there is no statistical difference in the outcomes of tibia fractures treated with either solid or hollow nail groups such as duration of surgery (p = 0.541), rate of delayed and non-union (p = 0.342), and rate of surgical site infections (p = 0.395). Conclusion: Intramedullary nailing of tibia shaft fractures with either solid or hollow nails have similar functional outcomes.
文摘Linked tetra shaft and double cantilever flat flap gate is a new type of structure in water conservancy projects,but the traditional method is now adopted in its design.In order to the application and dissemination of the type of sluice,this paper researches the difficult points of design advance,through researching the motion locus & stress coundition of linked tetra shaft system.The writer will build up the mathmatical model and handle it with the computer.Thus,we can achieve the modern desing on the basis of the software of linked tetra shaft system development.
基金Project (No. 60337030) partly supported by the National NaturalScience Foundation of China
文摘Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.
基金Supported by National Natural Science Foundation of China (Grant No.11972129)National Science and Technology Major Project of China (Grant No.2017-IV-0008-0045)+1 种基金Heilongjiang Provincial Natural Science Foundation (Grant No.YQ2022A008)the Fundamental Research Funds for the Central Universities。
文摘The crack fault is one of the most common faults in the rotor system,and researchers have paid close attention to its fault diagnosis.However,most studies focus on discussing the dynamic response characteristics caused by the crack rather than estimating the crack depth and position based on the obtained vibration signals.In this paper,a novel crack fault diagnosis and location method for a dual-disk hollow shaft rotor system based on the Radial basis function(RBF)network and Pattern recognition neural network(PRNN)is presented.Firstly,a rotor system model with a breathing crack suitable for a short-thick hollow shaft rotor is established based on the finite element method,where the crack's periodic opening and closing pattern and different degrees of crack depth are considered.Then,the dynamic response is obtained by the harmonic balance method.By adjusting the crack parameters,the dynamic characteristics related to the crack depth and position are analyzed through the amplitude-frequency responses and waterfall plots.The analysis results show that the first critical speed,first subcritical speed,first critical speed amplitude,and super-harmonic resonance peak at the first subcritical speed can be utilized for the crack fault diagnosis.Based on this,the RBF network and PRNN are adopted to determine the depth and approximate location of the crack respectively by taking the above dynamic characteristics as input.Test results show that the proposed method has high fault diagnosis accuracy.This research proposes a crack detection method adequate for the hollow shaft rotor system,where the crack depth and position are both unknown.
基金supported by the National Natural Science Foundation of China(No.51975293)Aeronautical Science Foundation of China (No. 2019ZD052010)
文摘Aiming at the shortcomings of traditional contact measurement methods such as low measurement efficiency,high cost and low accuracy,a non-contact optical measurement method based on the laser displacement sensor is proposed.According to the relevant regulations of the coaxiality error evaluation standard and the structural characteristics of the compound gear shaft,we have designed and built a set of supporting software system as well as a hardware test platform.In this paper,the distance difference threshold and scale threshold methods are used to eliminate outlier data.The least squares circle is selected to calculate the center of the circle and the minimum containment cylinder axis method is used as the reference axis of the composite gear shaft.Compensated by the standard step shaft calibration,the coaxiality error of the composite gear shaft can be measured to be within 0.01 mm in less than two minutes.The range value of the multi-section measurement test is 0.065 mm.The average coaxiality error is∅0.476 mm.
基金Funded by the National Natural Science Foundation of China (60337030) .
文摘Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with the measurement software. The laser alignment system with dual PSDs was improved on a single PSD system,and it gets higher measurement accuracy than the previous design,and it has been succeeded in designing and implement for actual shaft alignment. In the system,the range of offset measurement is ±4 mm,and the resolution is 1.5 μm,and the accuracy is less than 2 μm.
基金supported by the National Natural Science Foundation of China(22078030,52021004)Natural Science Foundation of Chongqing(2022NSCO-LZX0014)+1 种基金Fundamental Research Funds for the Central Universities(2022CDJQY-005,2023CDJXY-047)National Key Research and Development Project(2022YFC3901204)。
文摘Efficiently modulating the velocity distribution and flow pattern of non-Newtonian fluids is a critical challenge in the context of dual shaft eccentric mixers for process intensification,posing a significant barrier for the existing technologies.Accordingly,this work reports a convenient strategy that changes the kinetic energy to controllably regulate the flow patterns from radial flow to axial flow.Results showed that the desired velocity distribution and flow patterns could be effectively obtained by varying the number and structure of baffles to change kinetic energy,and a more uniform velocity distribution,which could not be reached normally in standard baffle dual shaft mixers,was easily obtained.Furthermore,a comparative analysis of velocity and shear rate distributions is employed to elucidate the mechanism behind the generation of flow patterns in various dual-shaft eccentric mixers.Importantly,there is little difference in the power number of the laminar flow at the same Reynolds number,meaning that the baffle type has no effect on the power consumption,while the power number of both unbaffle and U-shaped baffle mixing systems decreases compared with the standard baffle mixing system in the transition flow.Finally,at the same rotational condition,the dimensionless mixing time of the U-shaped baffle mixing system is 15.3%and 7.9%shorter than that of the standard baffle and the unbaffle mixing system,respectively,which shows the advantage of the U-shaped baffle in stirring rate.
文摘In this study, the influence of geometrical parameters on the curve veering phenomenon in a tor-sional system with stepped shaft is investigated. Three approximate solutions including finite el-ement, Rayleigh-Ritz and discretization methods, along with an exact solution are employed to obtain the natural frequencies of the structure. The study reveals that, under specific circumstances, the results obtained by approximate methods are very close to the exact solution. The curve veering behavior is manifested irrespective of the method employed. It is concluded that for the structure studied the curve veering behavior is not because of the approximate techniques used to compute the natural frequencies, and is an inherent behavior of the structure.
基金supported by the S&T Special Program of Huzhou(Grant No.2023GZ09)the Open Fund Project of the ShanghaiKey Laboratory of Lightweight Structural Composites(Grant No.2232021A4-06).
文摘Carbon fiber composites,characterized by their high specific strength and low weight,are becoming increasingly crucial in automotive lightweighting.However,current research primarily emphasizes layer count and orientation,often neglecting the potential of microstructural design,constraints in the layup process,and performance reliability.This study,therefore,introduces a multiscale reliability-based design optimization method for carbon fiber-reinforced plastic(CFRP)drive shafts.Initially,parametric modeling of the microscale cell was performed,and its elastic performance parameters were predicted using two homogenization methods,examining the impact of fluctuations in microscale cell parameters on composite material performance.A finite element model of the CFRP drive shaft was then constructed,achieving parameter transfer between microscale and macroscale through Python programming.This enabled an investigation into the influence of both micro and macro design parameters on the CFRP drive shaft’s performance.The Multi-Objective Particle Swarm Optimization(MOPSO)algorithm was enhanced for particle generation and updating strategies,facilitating the resolution of multi-objective reliability optimization problems,including composite material layup process constraints.Case studies demonstrated that this approach leads to over 30%weight reduction in CFRP drive shafts compared to metallic counterparts while satisfying reliability requirements and offering insights for the lightweight design of other vehicle components.
基金supported by Prince Sultan University(Grant No.PSU-CE-TECH-135,2023).
文摘In 2023,pivotal advancements in artificial intelligence(AI)have significantly experienced.With that in mind,traditional methodologies,notably the p-y approach,have struggled to accurately model the complex,nonlinear soil-structure interactions of laterally loaded large-diameter drilled shafts.This study undertakes a rigorous evaluation of machine learning(ML)and deep learning(DL)techniques,offering a comprehensive review of their application in addressing this geotechnical challenge.A thorough review and comparative analysis have been carried out to investigate various AI models such as artificial neural networks(ANNs),relevance vector machines(RVMs),and least squares support vector machines(LSSVMs).It was found that despite ML approaches outperforming classic methods in predicting the lateral behavior of piles,their‘black box'nature and reliance only on a data-driven approach made their results showcase statistical robustness rather than clear geotechnical insights,a fact underscored by the mathematical equations derived from these studies.Furthermore,the research identified a gap in the availability of drilled shaft datasets,limiting the extendibility of current findings to large-diameter piles.An extensive dataset,compiled from a series of lateral loading tests on free-head drilled shaft with varying properties and geometries,was introduced to bridge this gap.The paper concluded with a direction for future research,proposes the integration of physics-informed neural networks(PINNs),combining data-driven models with fundamental geotechnical principles to improve both the interpretability and predictive accuracy of AI applications in geotechnical engineering,marking a novel contribution to the field.
文摘Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.
基金Projects(2013RC16,2012LWB28)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(NCET-13-1019)supported by the Program for New Century Excellent Talents in University,China
文摘A new short-term warning and integrity monitoring algorithm was proposed for coal mine shaft safety. The Kalman filter (KF) model was used to extract real global positioning system (GPS) kinematic deformation information. The short-term warning model was built by using the two-side cumulative sum (CUSUM) test, which further improves the warning system reliability. Availability (the minimum warning deformation, MWD), false alarm rate (the average run length, ARL), missed rate (the warning delay, WD) and the relationships among them were analyzed and the method choosing warning parameters is given. A test of a deformation simulation platform shows that the warning algorithm can be effectively used for steep deformation warning. A field experiment of the Malan mine shaft in Shanxi coal area illustrates that the proposed algorithm can detect small dynamic changes and the corresponding occurring time. At given warning thresholds (MWD is 15 mm and ARL is 1000),the detected deformations of two consecutive days’ deformation sequences with the algorithm occur at the 705th epoch (705 s) and the 517th epoch (517 s), respectively.
基金The National Natural Science Foundation of China(No.51178217)the Natural Science Foundation of Jiangsu Province(No.BK2011804)
文摘The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperatures below the tunnel ceiling reduce rapidly along the longitudinal towards the tunnel exits. A noticeable temperature stratification is observed near the fire source.Most fire smoke is exhausted out of the shafts while the number of the smoke shafts in the downstream is more than that in the upstream.Large eddy simulation LES based on computational fluid dynamics CFD is carried out using the fire dynamics simulator FDS software with parallel processing in which the grid size of the fire-domain is set to be 0.083 m.The simulation results of temperatures under the ceiling the smoke fronts and the shafts'smoke exhaust or air supply agree reasonably with the experimental data. Further simulations indicate that the decreasing ambient temperature or shaft spacing might reduce smoke temperatures under the tunnel ceiling and increase mass flow rates out of the shafts.This study provides technical scientific evidence and supports for the design and construction of such kinds of tunnels.