Pulse shortening hinders improvement of microwave output energy for high power microwave tubes. So far, it is also an unresolved problem in the field of high power microwave devices.In this paper, relativistic backwar...Pulse shortening hinders improvement of microwave output energy for high power microwave tubes. So far, it is also an unresolved problem in the field of high power microwave devices.In this paper, relativistic backward wave tube (RBWO) is treated as an example to study the pulse shortening phenomena. The influences of gas existing in the tube and explosive emission in inner surface of RBWO are all investigated by means of the particle-in-cell method. Through the simulation results, it can be predicted that the background gas in the tube is one but not the most important factor resulting in pulse shortening, in order to broaden the pulse width of gas-filled RBWO, the pressure of the filled gas must be controlled in a proper value. The explosive emission in the surface of slow wave structure due to intense electric field is one of the most important factors causing pulse shortening in high power microwave tube. Some methods to overcome this kind of explosive emission are also given.展开更多
An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulat...An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.展开更多
基金Supported by Fok Ying Tung Education Foundation (No. 81007) and National Natural Science Foundation of China (No. 10276011)
文摘Pulse shortening hinders improvement of microwave output energy for high power microwave tubes. So far, it is also an unresolved problem in the field of high power microwave devices.In this paper, relativistic backward wave tube (RBWO) is treated as an example to study the pulse shortening phenomena. The influences of gas existing in the tube and explosive emission in inner surface of RBWO are all investigated by means of the particle-in-cell method. Through the simulation results, it can be predicted that the background gas in the tube is one but not the most important factor resulting in pulse shortening, in order to broaden the pulse width of gas-filled RBWO, the pressure of the filled gas must be controlled in a proper value. The explosive emission in the surface of slow wave structure due to intense electric field is one of the most important factors causing pulse shortening in high power microwave tube. Some methods to overcome this kind of explosive emission are also given.
基金supported by the Chinese National Natural Science Foundation (Grant No 10675168)Innovation Fund of Graduate School of the National University of Defense Technology of China
文摘An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.