Distributed Signal Condition System for EAST Tokamak
1
作者 吴一纯 罗家融 +2 位作者 季振山 王勇 李实 《Journal of Donghua University(English Edition)》 EI CAS 2010年第1期92-97,共6页
In order to achieve both the signal condition remote control and the work statute self-check through Ethernet,a distributed signal condition (DSC) system has been developed for control and data acquisition (CODAC) in ... In order to achieve both the signal condition remote control and the work statute self-check through Ethernet,a distributed signal condition (DSC) system has been developed for control and data acquisition (CODAC) in the EAST tokamak nuclear fusion experiment.Based on differential amplifiers,analog multiplexers and the embedded Ethernet communication technology,a DSC system is designed and produced.This paper summarizes the DSC system design,and presents a kind of calibration method for it.This DSC system has been integrated into the EAST CODAC system,and used successfully in the 2008 EAST experiments.The user-friendly,high performance,and cost-effective DSC system greatly improves the work efficiency and reduces the fault rates of the CODAC system. 展开更多
关键词 EAST distributed signal condition CALIBRATION
下载PDF
A Thermometer Based on Diverse Types Thermocouples and Resistance Temperature Detectors 被引量:2
2
作者 朱敏玲 《Journal of Shanghai Jiaotong university(Science)》 EI 2015年第1期93-100,共8页
A universal and low-cost temperature thermometer is realized via a special circuit,integrated circuit chip with microprocessor and analog to digital converter,and digital bus interface.Various thermocouples and resist... A universal and low-cost temperature thermometer is realized via a special circuit,integrated circuit chip with microprocessor and analog to digital converter,and digital bus interface.Various thermocouples and resistance temperature detectors used for temperature sensing may be connected to same thermometer.A special signal condition circuitry is designed and a matching algorithm is proposed.A novel calibration method named disassembled calibration is proposed in order to enhance efficiency and flexibility for the whole system.Additionally,it presents a combination method of low order polynomial fitting and piecewise linearity for the nonlinearity calibration of the thermocouple and the resistance temperature detector.A cold junction compensation based on digital way is described.And the matching algorithm and calibration method may eliminate errors stemming from excitation voltage source and reference voltage source,and can weaken quantization error of analog to digital converter and drift of components,too.Furthermore,the 400 times oversampling is completed by sequential and equal interval sampling to upgrade accuracy of analog to digital converter from original 12 to 15 bits and to raise signal-to-noise ratio.Finally,during a long time monitoring,experiment results show that errors at each static point are less than±0.2°C for the thermocouple system and less than±0.1°C for the resistance temperature detector system. 展开更多
关键词 temperature thermometer THERMOCOUPLE resistance temperature detector calibration cold junction compensation algorithm signal condition circuitry