期刊文献+
共找到110篇文章
< 1 2 6 >
每页显示 20 50 100
Single Photon Detection Technology in Underwater Wireless Optical Communication:Modulation Modes and Error Correction Coding Analysis
1
作者 GAI Lei LI Wendong WANG Guoyu 《Journal of Ocean University of China》 CAS CSCD 2024年第2期405-414,共10页
This study explores the application of single photon detection(SPD)technology in underwater wireless optical communication(UWOC)and analyzes the influence of different modulation modes and error correction coding type... This study explores the application of single photon detection(SPD)technology in underwater wireless optical communication(UWOC)and analyzes the influence of different modulation modes and error correction coding types on communication performance.The study investigates the impact of on-off keying(OOK)and 2-pulse-position modulation(2-PPM)on the bit error rate(BER)in single-channel intensity and polarization multiplexing.Furthermore,it compares the error correction performance of low-density parity check(LDPC)and Reed-Solomon(RS)codes across different error correction coding types.The effects of unscattered photon ratio and depolarization ratio on BER are also verified.Finally,a UWOC system based on SPD is constructed,achieving 14.58 Mbps with polarization OOK multiplexing modulation and 4.37 Mbps with polarization 2-PPM multiplexing modulation using LDPC code error correction. 展开更多
关键词 error correction coding modulation mode single photon detection underwater communication wireless optical communication
下载PDF
Photostability of colloidal single photon emitter in near-infrared regime at room temperature
2
作者 靳思玥 许兴胜 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期515-520,共6页
The photostability of a colloidal single photon emitter in near-infrared regime at room temperature is investigated.The fluorescence lifetime,blinking phenomenon,and anti-bunching effect of a single CdTeSe/ZnS quantum... The photostability of a colloidal single photon emitter in near-infrared regime at room temperature is investigated.The fluorescence lifetime,blinking phenomenon,and anti-bunching effect of a single CdTeSe/ZnS quantum dot with an emission wavelength of 800 nm at room temperature are studied.The second-order correlation function at zero delay time is much smaller than 0.1,which proves that the emission from single quantum dots at 800 nm is a highly pure single-photon source.The effects of the irradiation duration on the fluorescence from single quantum dots are analyzed.The experimental results can be explained by a recombination model including a multi-nonradiative recombination center model and a multi-charged model. 展开更多
关键词 colloidal quantum dots single photon source BLINKING
下载PDF
Technetium-99m-methylene diphosphonate single photon emission computed tomography/computed tomography combined with prostate-specific antigen/free prostate-specific antigen ratio for bone metastasis of prostate cancer
3
作者 Jian He Yi-Pu Zhong Shuang Zhang 《World Journal of Clinical Cases》 SCIE 2024年第20期4082-4090,共9页
BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To inves... BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice. 展开更多
关键词 Matrix metalloproteinase 9 single photon emission computed tomography Prostate-specific antigen to free prostate-specific antigen ratio Prostate cancer Bone metastasis
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
4
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile single photon emission computed tomography X-ray computed tomography Case report
下载PDF
Internal cancellation of spikes using two avalanche photodiodes in series for single photon detection
5
作者 刘云 吴青林 +2 位作者 韩正甫 戴逸民 郭光灿 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期123-126,共4页
We propose a method of improving the performance of InGaAs/InP avalanche photodiodes by using two avalanche photodiodes in series as single photon detectors for 1550-nm wavelength. In this method, the raw single photo... We propose a method of improving the performance of InGaAs/InP avalanche photodiodes by using two avalanche photodiodes in series as single photon detectors for 1550-nm wavelength. In this method, the raw single photon avalanche signals are not attenuated, thus a high signal-to-noise ratio can be obtained compared with the existing results. The performance of the scheme is investigated and the ratio of the dark count rate to the detection efficiency is obtained to be 1.3×10^-4 at 213 K. 展开更多
关键词 quantum information quantum key distribution single photon detection single photon counting
下载PDF
Numerical analysis of In_(0.53) Ga_(0.47) As/InP single photon avalanche diodes
6
作者 周鹏 李淳飞 +2 位作者 廖常俊 魏正军 袁书琼 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期561-567,共7页
A rigorous theoretical model for Ino.53Gao.47As/InP single photon avalanche diode is utilized to investigate the dependences of single photon quantum efficiency and dark count probability on structure and operation co... A rigorous theoretical model for Ino.53Gao.47As/InP single photon avalanche diode is utilized to investigate the dependences of single photon quantum efficiency and dark count probability on structure and operation condition. In the model, low field impact ionizations in charge and absorption layers are allowed, while avalanche breakdown can occur only in the multiplication layer. The origin of dark counts is discussed and the results indicate that the dominant mechanism that gives rise to dark counts depends on both device structure and operating condition. When the multiplication layer is thicker than a critical thickness or the temperature is higher than a critical value, generation-recombination in the absorption layer is the dominative mechanism; otherwise band-to-band tunneling in the multiplication layer dominates the dark counts. The thicknesses of charge and multiplication layers greatly affect the dark count and the peak single photon quantum efficiency and increasing the multiplication layer width may reduce the dark count probability and increase the peak single photon quantum efficiency. However, when the multiplication layer width exceeds 1 μm, the peak single photon quantum efficiency increases slowly and it is finally saturated at the quantum efficiency of the single photon avalanche diodes. 展开更多
关键词 single photon avalanche diodes gate-mode single photon quantum efficiency dark count probability
下载PDF
Economical quantum secure direct communication network with single photons 被引量:10
7
作者 邓富国 李熙涵 +2 位作者 李春燕 周萍 周宏余 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第12期3553-3559,共7页
In this paper a scheme for quantum secure direct communication (QSDC) network is proposed with a sequence of polarized single photons. The single photons are prepared originally in the same state (0) by the server... In this paper a scheme for quantum secure direct communication (QSDC) network is proposed with a sequence of polarized single photons. The single photons are prepared originally in the same state (0) by the servers on the network, which will reduce the difficulty for the legitimate users to check eavesdropping largely. The users code the information on the single photons with two unitary operations which do not change their measuring bases. Some decoy photons, which are produced by operating the sample photons with a Hadamard, are used for preventing a potentially dishonest server from eavesdropping the quantum lines freely. This scheme is an economical one as it is the easiest way for QSDC network communication securely. 展开更多
关键词 quantum secure direct communication NETWORK single photons
下载PDF
Recent progress of SiC UV single photon counting avalanche photodiodes 被引量:6
8
作者 Linlin Su Dong Zhou +2 位作者 Hai Lu Rong Zhang Youdou Zheng 《Journal of Semiconductors》 EI CAS CSCD 2019年第12期59-69,共11页
4H-SiC single photon counting avalanche photodiodes(SPADs)are prior devices for weak ultraviolet(UV)signal detection with the advantages of small size,low leakage current,high avalanche multiplication gain,and high qu... 4H-SiC single photon counting avalanche photodiodes(SPADs)are prior devices for weak ultraviolet(UV)signal detection with the advantages of small size,low leakage current,high avalanche multiplication gain,and high quantum efficiency,which benefit from the large bandgap energy,high carrier drift velocity and excellent physical stability of 4 H-SiC semiconductor material.UV detectors are widely used in many key applications,such as missile plume detection,corona discharge,UV astronomy,and biological and chemical agent detection.In this paper,we will describe basic concepts and review recent results on device design,process development,and basic characterizations of 4 H-SiC avalanche photodiodes.Several promising device structures and uniformity of avalanche multiplication are discussed,which are important for achieving high performance of 4 HSiC UV SPADs. 展开更多
关键词 SIC avalanche photodiodes single photon counting ultraviolet detection
下载PDF
Practical non-orthogonal decoy state quantum key distribution with heralded single photon source 被引量:4
9
作者 米景隆 王发强 +1 位作者 林青群 梁瑞生 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第4期1178-1183,共6页
Recently the performance of the quantum key distribution (QKD) is substantially improved by the decoy state method and the non-orthogonal encoding protocol, separately. In this paper, a practical non-orthogonal deco... Recently the performance of the quantum key distribution (QKD) is substantially improved by the decoy state method and the non-orthogonal encoding protocol, separately. In this paper, a practical non-orthogonal decoy state protocol with a heralded single photon source (HSPS) for QKD is presented. The protocol is based on 4 states with different intensities. i.e. one signal state and three decoy states. The signal state is for generating keys; the decoy states are for detecting the eavesdropping and estimating the fraction of single-photon and two-photon pulses. We have discussed three cases of this protocol, i.e. the general case, the optimal case and the special case. Moreover, the final key rate over transmission distance is simulated. For the low dark count of the HSPS and the utilization of the two-photon pulses, our protocol has a higher key rate and a longer transmission distance than any other decoy state protocol. 展开更多
关键词 quantum key distribution decoy state non-orthogonal encoding protocol heralded single photon source
下载PDF
High photon detection efficiency InGaAs/InP single photon avalanche diode at 250 K 被引量:4
10
作者 Tingting He Xiaohong Yang +2 位作者 Yongsheng Tang Rui Wang Yijun Liu 《Journal of Semiconductors》 EI CAS CSCD 2022年第10期56-63,共8页
Planar semiconductor InGaAs/InP single photon avalanche diodes with high responsivity and low dark count rate are preferred single photon detectors in near-infrared communication.However,even with well-designed struct... Planar semiconductor InGaAs/InP single photon avalanche diodes with high responsivity and low dark count rate are preferred single photon detectors in near-infrared communication.However,even with well-designed structures and well-con-trolled operational conditions,the performance of InGaAs/InP SPADs is limited by the inherent characteristics of avalanche pro-cess and the growth quality of InGaAs/InP materials.It is difficult to ensure high detection efficiency while the dark count rate is controlled within a certain range at present.In this paper,we fabricated a device with a thick InGaAs absorption region and an anti-reflection layer.The quantum efficiency of this device reaches 83.2%.We characterized the single-photon performance of the device by a quenching circuit consisting of parallel-balanced InGaAs/InP single photon detectors and single-period sinus-oidal pulse gating.The spike pulse caused by the capacitance effect of the device is eliminated by using the characteristics of parallel balanced common mode signal elimination,and the detection of small avalanche pulse amplitude signal is realized.The maximum detection efficiency is 55.4%with a dark count rate of 43.8 kHz and a noise equivalent power of 6.96×10^(−17 )W/Hz^(1/2) at 247 K.Compared with other reported detectors,this SPAD exhibits higher SPDE and lower noise-equivalent power at a higher cooling temperature. 展开更多
关键词 single period sinusoidal pulse InGaAs/InP single photon avalanche diode parallel balanced photon detection effi-ciency dark count rate noise-equivalent power
下载PDF
Superconducting Nanowire Single Photon Detector with Optical Cavity 被引量:2
11
作者 刘杰 张立群 +3 位作者 蒋振南 Kamal Ahmad 刘建设 陈炜 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第8期143-145,共3页
Increasing the detection efficiency (DE) is a hot issue in the development of the superconducting nanowire single photon detector (SNSPD). In this work, a cavity-integrated structure coupled to the SNSPD is used t... Increasing the detection efficiency (DE) is a hot issue in the development of the superconducting nanowire single photon detector (SNSPD). In this work, a cavity-integrated structure coupled to the SNSPD is used to enhance the light absorption of nanowire. Ultra-thin Nb films are successfully prepared by magnetron sputtering, which are used to fabricate Nb/Al SNSPD with the curve of lOOnm and the square area of 4 × 4μm2 by sputtering and the lift-off method. To characterize the optical and electrical performance of the cavity-integrated SNSPD, a reliable cryogenic research system is built up based on a He3 system. To satisfy the need of light coupling, a packaging structure with collimator is conducted. Both DE and the dark count rates increase with lb. It is also found that the DE of SNSPD with cavities can be up to 0.17% at the temperature of 0.7K under the infrared light of 1550nm, which is obviously higher than that of the SNSPD directly fabricated upon silicon without any cavity structure. 展开更多
关键词 of on with Superconducting Nanowire single photon Detector with Optical Cavity DBR DE in IS been that
下载PDF
Single Photon Scattering in a Pair of Waveguides Coupled by a Whispering-Gallery Resonator Interacting with a Semiconductor Quantum Dot 被引量:2
12
作者 程木田 叶根龙 +1 位作者 纵卫卫 马小三 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第2期47-50,共4页
The single photon scattering properties in a pair of waveguides coupled by a whispering-gallery resonator in- teracting with a semiconductor quantum dot are investigated theoretically. The two waveguides support four ... The single photon scattering properties in a pair of waveguides coupled by a whispering-gallery resonator in- teracting with a semiconductor quantum dot are investigated theoretically. The two waveguides support four possible ports for an incident single photon. The quantum dot is considered a V-type system. The incident direction-dependent single photon scattering properties are studied and equal-output probability from the four ports for a single photon incident is discussed. The influences of backscattering between the two modes of the whispering-gallery resonator for incident direction-dependent single photon scattering properties are also pre- sented. 展开更多
关键词 of is from in single photon Scattering in a Pair of Waveguides Coupled by a Whispering-Gallery Resonator Interacting with a Semiconductor Quantum Dot mode with by
下载PDF
Single photon transport properties in coupled cavity arrays nonlocally coupled to a two-level atom in the presence of dissipation 被引量:2
13
作者 海莲 谭磊 +2 位作者 冯金山 徐文斌 王彬 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期257-261,共5页
We discuss the effects of dissipation on the behavior of single photon transport in a system of coupled cavity arrays, with the two nearest cavities nonlocally coupled to a two-level atom. The single photon transmissi... We discuss the effects of dissipation on the behavior of single photon transport in a system of coupled cavity arrays, with the two nearest cavities nonlocally coupled to a two-level atom. The single photon transmission amplitude is solved exactly by employing the quasi-boson picture. We investigate two different situations of local and nonlocal couplings, respectively. Comparing the dissipative case with the nondissipative one reveals that the dissipation of the system increases the middle dip and lowers the peak of the single photon transmission amplitudes, broadening the line width of the transport spectrum. It should be noted that the influence of the cavity dissipation to the single photon transport spectrum is asymmet- ric. By comparing the nonlocal coupling with the local one, one can find that the enhancement of the middle dip of single photon transmission amplitudes is mostly caused by the atom dissipation and that the reduced peak is mainly caused by the cavity dissipation, no matter whether it is a nonlocal or local coupling case. Whereas in the nonlocal coupling case, when the coupling strength gets stronger, the cavity dissipation has a greater effect on the single photon transport spectrum and the atom dissipation affection becomes weak, so it can be ignored. 展开更多
关键词 single photon transport dissipative coupled cavity arrays dissipative two-level atom local and nonlocal couplings
下载PDF
Quantum frequency down-conversion of single photons at 1552 nm from single InAs quantum dot 被引量:2
14
作者 马奔 魏思航 +3 位作者 陈泽升 尚向军 倪海桥 牛智川 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第9期595-599,共5页
Near-infrared single photon sources in telecommunication bands, especially at 1550 nm, are required for long-distance quantum communication. Here a down-conversion quantum interface is implemented, where the single ph... Near-infrared single photon sources in telecommunication bands, especially at 1550 nm, are required for long-distance quantum communication. Here a down-conversion quantum interface is implemented, where the single photons emitted from single In As quantum dot at 864 nm is down converted to 1552 nm by using a fiber-coupled periodically poled lithium niobate(PPLN) waveguide and a 1.95 μmm pump laser, and the frequency conversion efficiency is ~40%. The singlephoton purity of quantum dot emission is preserved during the down-conversion process, i.e., g^((2))(0), only 0.22 at 1552 nm.This present technique advances the Ⅲ-Ⅴ semiconductor quantum dots as a promising platform for long-distance quantum communication. 展开更多
关键词 quantum frequency down-conversion quantum dot telecommunication band single photon
下载PDF
Quantification of Tc-99m-ethyl cysteinate dimer brain single photon emission computed tomography images using statistical probabilistic brain atlas in depressive end-stage renal disease patients:Correlation with disease severity and symptom factors 被引量:1
15
作者 Heeyoung Kim In Joo Kim +3 位作者 Seong-Jang Kim Sang Heon Song Kyoungjune Pak Keunyoung Kim 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第27期2151-2159,共9页
This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the r... This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pailidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients. 展开更多
关键词 single photon emission computed tomography end-stage renal disease depression statisticalprobabilistic brain atlas disease severity cerebral blood flow SYMPTOM BRAIN neural regeneration
下载PDF
Detection efficiency characteristics of free-running InGaAs/InP single photon detector using passive quenching active reset IC 被引量:1
16
作者 郑福 王超 +1 位作者 孙志斌 翟光杰 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期460-464,共5页
InGaAs/InP avalanche photodiodes (APD) are rarely used in a free-running regime for near-infrared single photon detection. In order to overcome the detrimental afterpulsing, we demonstrate a passive quenching active... InGaAs/InP avalanche photodiodes (APD) are rarely used in a free-running regime for near-infrared single photon detection. In order to overcome the detrimental afterpulsing, we demonstrate a passive quenching active reset integrated circuit. Taking advantage of the inherent fast passive quenching process and active reset to reduce reset time, the integrated circuit is useful for reducing afterpulses and is also area-efficient. We investigate the free-running single photon detector's afterpulsing effect, de-trapping time, dark count rate, and photon detection efficiency, and also compare with gated regime operation. After correction for deadtime and afterpulse, we find that the passive quenching active reset free-running single photon detector's performance is consistent with gated operation. 展开更多
关键词 single photon detector free-running passive quenching active reset
下载PDF
PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response 被引量:1
17
作者 樊馨 王海鹏 +8 位作者 贠明凯 孙校丽 曹学香 刘双全 柴培 李道武 刘宝东 王璐 魏龙 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期542-550,共9页
A point spread function(PSF) for the blurring component in positron emission tomography(PET) is studied. The PSF matrix is derived from the single photon incidence response function. A statistical iterative recons... A point spread function(PSF) for the blurring component in positron emission tomography(PET) is studied. The PSF matrix is derived from the single photon incidence response function. A statistical iterative reconstruction(IR) method based on the system matrix containing the PSF is developed. More specifically, the gamma photon incidence upon a crystal array is simulated by Monte Carlo(MC) simulation, and then the single photon incidence response functions are calculated. Subsequently, the single photon incidence response functions are used to compute the coincidence blurring factor according to the physical process of PET coincidence detection. Through weighting the ordinary system matrix response by the coincidence blurring factors, the IR system matrix containing the PSF is finally established. By using this system matrix, the image is reconstructed by an ordered subset expectation maximization(OSEM) algorithm. The experimental results show that the proposed system matrix can substantially improve the image radial resolution, contrast,and noise property. Furthermore, the simulated single gamma-ray incidence response function depends only on the crystal configuration, so the method could be extended to any PET scanner with the same detector crystal configuration. 展开更多
关键词 point spread function single photon incidence system matrix positron emission tomography
下载PDF
Efficient quantum private comparison protocol utilizing single photons and rotational encryption 被引量:1
18
作者 寇天翊 车碧琛 +3 位作者 窦钊 陈秀波 赖裕平 李剑 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第6期221-227,共7页
As a branch of quantum secure multiparty computation,quantum private comparison is applied frequently in many fields,such as secret elections,private voting,and identification.A quantum private comparison protocol wit... As a branch of quantum secure multiparty computation,quantum private comparison is applied frequently in many fields,such as secret elections,private voting,and identification.A quantum private comparison protocol with higher efficiency and easier implementation is proposed in this paper.The private secrets are encoded as single polarized photons and then encrypted with a homomorphic rotational encryption method.Relying on this method and the circular transmission mode,we implement the multiplexing of photons,raising the efficiency of our protocol to 100%.Our protocol is easy to realize since only single photons,unitary operation,and single-particle measurement are introduced.Meanwhile,the analysis shows that our protocol is also correct and secure. 展开更多
关键词 quantum private comparison rotational encryption polarized single photons EFFICIENCY
下载PDF
Statistical analysis of the temporal single-photon response of superconducting nanowire single photon detection 被引量:1
19
作者 何宇昊 吕超林 +5 位作者 张伟君 张露 巫君杰 陈思井 尤立星 王镇 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期150-154,共5页
A new method to study the transient detection efficiency (DE) and pulse amplitude of superconducting nanowire single photon detectors (SNSPD) during the current recovery process is proposed -- statistically analyz... A new method to study the transient detection efficiency (DE) and pulse amplitude of superconducting nanowire single photon detectors (SNSPD) during the current recovery process is proposed -- statistically analyzing the single photon response under photon illumination with a high repetition rate. The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event. This proves that static measurement results can be used to analyze the transient current recovery process after a detection event. The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs. 展开更多
关键词 single photon detector recovery process kinetic inductance
下载PDF
Same day yttrium-90 radioembolization with single photon emission computed tomography/computed tomography: An opportunity to improve care during the COVID-19 pandemic and beyond 被引量:1
20
作者 Mohammad Elsayed Mohammad Loya +9 位作者 James Galt David M Schuster Zachary L Bercu Janice Newsome David Brandon Sonia Benenati Keywan Behbahani Richard Duszak Ila Sethi Nima Kokabi 《World Journal of Gastrointestinal Oncology》 SCIE 2021年第5期440-452,共13页
BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical chal... BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19,thus improving patient access.AIM To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography(SPECT/CT)in order to optimize therapy.METHODS All patients were selected for Y-90 RE through a multidisciplinary tumor board,and were screened and tested for COVID-19 infection per institutional protocol.A same day procedure was developed,consisting of angiography,imaging,and Y-90 resin particle delivery.Routine SPECT/CT after technetium-99m macroaggregated albumin(Tc-99m MAA)administration was performed for assessment of arterial supply,personalized dosimetry,and extrahepatic activity.Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery,by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles.RESULTS A total of 14 patients underwent same day Y-90 RE between March and June 2020.Mean lung shunt fraction was 6.13%(range 3.5%-13.1%).Y-90 RE was performed for a single lesion in 7 patients,while the remaining 7 patients had treatment of multifocal lesions.The largest lesion measured 8.3 cm.All patients tolerated the procedure well and were discharged the same day.CONCLUSION Same day Y-90 RE with resin-based microspheres is feasible,and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond.We recommend consideration of SPECT/CT,especially among patients with complex malignancies,for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE. 展开更多
关键词 Yttrium-90 radioembolization Same day Selective internal radiotherapy Transarterial radioembolization single photon emission computed tomography/computed tomography Dosimetry COVID-19
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部