To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wid...To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.展开更多
Enjoying a pleasant interior temperature in both summer and winter without the necessity for additional heating or cooling—a level of comfort already offered by private homes built with an eye to energy effi ciency.W...Enjoying a pleasant interior temperature in both summer and winter without the necessity for additional heating or cooling—a level of comfort already offered by private homes built with an eye to energy effi ciency.What has become known as the passive house standard is now increasingly demanded in tenders and competitions revolving around offi ce buildings.Below,Dr Friedrich Sick,professor at the HTW Berlin,and Stefan Schade,a graduate in Environmental Engineering/Renewable Energies who explored this particular fi eld in his thesis[1],examine the conditions necessary for the implementation of this standard.展开更多
基金UAE University Under Contracts No. 07-34-07-11/07 and 07-01-07-11/09
文摘To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.
文摘Enjoying a pleasant interior temperature in both summer and winter without the necessity for additional heating or cooling—a level of comfort already offered by private homes built with an eye to energy effi ciency.What has become known as the passive house standard is now increasingly demanded in tenders and competitions revolving around offi ce buildings.Below,Dr Friedrich Sick,professor at the HTW Berlin,and Stefan Schade,a graduate in Environmental Engineering/Renewable Energies who explored this particular fi eld in his thesis[1],examine the conditions necessary for the implementation of this standard.