期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Research on strategies for reducing the irritability of potassium cocoyl glycinate in cleansing
1
作者 Anli Peng Jialei Yan +4 位作者 Jianming Wang Jingru Qian Yao Qin Yaxin Zhang Tingzhi Zhang 《Journal of Dermatologic Science and Cosmetic Technology》 2024年第3期49-58,共10页
Background:Potassium cocoyl glycinate,a kind of amino acid surfactant,is widely used as major component for facial cleansing.However,the interaction between surfactants and compounds in the stratum corneum has been su... Background:Potassium cocoyl glycinate,a kind of amino acid surfactant,is widely used as major component for facial cleansing.However,the interaction between surfactants and compounds in the stratum corneum has been suggested as a contributing factor to their potential skin irritancy.Objective:This study aimed to the effects of adding surfactants,polymers,lipids and active substances on diminishing skin irritation caused by potassium cocoyl glycinate.Materials and methods:Zein test and Hemolysis test enabled the identification of irritation to proteins and cells in the studied binary systems.The critical micelle concentration(CMC)was evaluated by the surface tension method.The power of the analyzed polymers to diminish irritation of potassium cocoyl glycinate was represented by the reduction rate.Results:(1)Amphoteric surfactants and nonionic surfactants are effective at reducing the irritation of potassium cocoyl glycinate in some cases by reducing CMC;(2)Addition of polymers to the potassium cocoyl glycinate solutions improves its safety of use.Hydroxypropyl methylcellulose could reduce the irritation by 88.63%;(3)Combining most lipids can assist in declining the irritation,Lppg-28-Buteth-35 could inhibit the irritation of red blood cells by 16.52%;(4)The effects of active substances varied,hydrolyzed sodium hyaluronate results in a significant reduction in irritation to cells.Conclusion:In facial cleansers based on potassium cocoyl glycinate,supplying co-surfactant,polymers,lipids and active substances can reduce the irritation to some extent,however,the effects are various. 展开更多
关键词 SURFACTANTS Potassium cocoyl glycinate skin irritation
下载PDF
Cytotoxicity,in Vivo Skin Irritation and Acute Systemic Toxicity of the Mesoporous Magnesium Carbonate Upsalite^(█) 被引量:1
2
作者 Sara Frykstrand Johan Forsgren +2 位作者 Peng Zhang Maria Stromme Natalia Ferraz 《Journal of Biomaterials and Nanobiotechnology》 2015年第4期257-266,共10页
Upsalite&reg;is a mesoporous magnesium carbonate synthesized without using surfactants and therefore highly attractive from environmental and production economy points of view. The material has recently been sugge... Upsalite&reg;is a mesoporous magnesium carbonate synthesized without using surfactants and therefore highly attractive from environmental and production economy points of view. The material has recently been suggested as drug delivery vehicle and as topical bacteriostatic agent. In order to continue exploring these and other bio-related applications of the material, primary biocompatibility studies are needed. Herein we present the first in vivo acute systemic toxicity and skin irritation analyses as well as in vitro cytotoxicity evaluations of Upsalite&reg;. The material was found to be non-toxic for human dermal fibroblasts cells up to a concentration of 1000 μg/ml and 48 h exposure in contrast to the mesoporous silica material SBA-15, used as reference, which significantly affected cell viability at particle concentration of 500 and 1000 μg/ml after the same exposure time. Topical application of Upsalite&reg;resulted in negligible cutaneous reactions in a rabbit skin irritation model and no evidence of significant systemic toxicity was found when saline extracts of Upsalite&reg;were injected in mice. Injection of sesame oil extract, however, resulted in transient weight loss, most likely due to injection of particles, and not toxic leachables. The presented results form the basis for future development of Upsalite&reg;and similar mesoporous materials in biomedical applications and further toxicity as well as biocompatibility studies should be directed towards specific areas of use. 展开更多
关键词 MESOPOROUS Magnesium Carbonate CYTOTOXICITY skin Irritation Acute Systemic Toxicity
下载PDF
Technical Approaches and in-vitro Evaluation Methods for Scalp Care 被引量:1
3
作者 Akira Nomachi Yang Jianzhong 《China Detergent & Cosmetics》 2018年第1期57-62,共6页
Scalp care is important in maintaining good conditions of scalp and hair. Key technical approaches for scalp care include reducing the chance of scalp inflammation, improving scalp defense, and activating hair follicl... Scalp care is important in maintaining good conditions of scalp and hair. Key technical approaches for scalp care include reducing the chance of scalp inflammation, improving scalp defense, and activating hair follicle cells. As the cosmetics industry is moving toward to alternative methods to animal testing based on the 3 Rs(Replacement, Reduction and Refinement), in vitro methods will be widely used to evaluate the effects of scalp care. In this paper, we describe the detailed technical approaches for scalp care and the in vitro evaluation methods for skin irritation, anti-inflammation, barrier function, blood circulation, hair growth and male pattern hair loss prevention, respectively. 展开更多
关键词 scalp health skin irritation scalp inflammation SEBUM barrier function hair growth hair loss
下载PDF
Graphene Oxide/Lauryl Betaine Nano Material Synthesis and Properties
4
作者 Wang Li Jing Jing +3 位作者 Zaixing Jiang Di Su Yongzhi Li Weihong Lu 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2021年第2期8-20,共13页
This paper aims at synthesizing a detergent with graphene oxide(GO)and lauryl betaine(LB),where the GO will have a better performance with the modification of LB.First,the complexus of GO and LB and the complexus of G... This paper aims at synthesizing a detergent with graphene oxide(GO)and lauryl betaine(LB),where the GO will have a better performance with the modification of LB.First,the complexus of GO and LB and the complexus of GO,KH550(Amino functional silane),and LB were synthesized to obtain two products,GO⁃LB and GO⁃KH550⁃LB.Then,the abilities and safety of the products were evaluated by characterization,contact angle measurement,measurement of KRAFFT Point,foaming test,emulsion ability test,decontamination capacity test,skin irritation test,and skin allergy test.Results of the experiment showed that GO⁃LB was superior to GO⁃KH550⁃LB in wetting ability and foaming stability,while GO⁃KH550⁃LB outperformed in emulsifying capacity.Besides,good abilities of removing mussels,seaweed,and protein were proved.According to the result of the irritation test of the materials to skin,they were both at the light irritation level,and the irritation of the GO⁃LB was slightly lower than that of GO⁃KH550⁃LB.Neither GO⁃LB nor GO⁃KH550⁃LB had allergic effect.Therefore,it can be concluded that as a surface active agent,graphene oxide/lauryl betaine was effective as a new detergent,which had low irritation and insignificant allergic phenomena on the human body over a long term of use. 展开更多
关键词 graphene oxide lauryl betaine surfactivity skin irritation skin allergy
下载PDF
In Vitro Assessment of Irritation Potential of an Anti-Melanogenic Agent,PF3758309,in a Reconstructed Human Epidermis Model
5
作者 Ayeong Lee Yu Rim Lee +6 位作者 Ji Yea Kim Jin Hyuk Jung Young Kum Park Yu-Jung Kim Sung-Nae Lee Sungkwan An Seunghee Bae 《北京日化》 2018年第4期33-40,共8页
Purpose:This study was designed to determine whether a novel anti-melanogenic agent,PF3758309,has the potential to cause acute cutaneous irritation using a human skin equivalent model (HSEM).Methods:Human skin equival... Purpose:This study was designed to determine whether a novel anti-melanogenic agent,PF3758309,has the potential to cause acute cutaneous irritation using a human skin equivalent model (HSEM).Methods:Human skin equivalent was constructed through incubation of normal human derived epidermal keratinocytes (HEKs)on collagen matrix insert with proliferation media.Using constructed human skin equivalent,the irritation potential of PF3758309 were investigated whether the viability of this agent-treated HESM is under 50%(irritant)or not (non-irritant)using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT)assay after applying the agent to the epidermal surface of the HSEM.Also,the PF3758309-mediated anti-pigmentation effects were analyzed using Fontana-Masson staining in the HSEM.Results:The integrity of the constructed HSEM was confirmed using immunohistochemical staining with differentiation markers of epidermis,and observed that Keratin 5,Keratin I and Involucrin were stained in basal,supra-basal and granular layers,respectively.In vitro irritation assay showed that the mean viabilities of the PF3758309 was 83.6%,78.8%and 77.8%at the treatment doses of 0.2,0.5 and I mg,respectively;however,the mean viability of the positive control (5%sodium dodecyl sulfate)-treated HESM was 2.8%.Also,in vitro corrosion assay showed that the mean viabilities of the PF3758309 was 95.3%,95.0%and 94.2% at the treatment doses of 0.2,0.5 and 1 mg,respectively.Furthermore,using a Fontana-Masson staining assay,the melanin levels in the PF3758309-treated HSEM was significantly decreased compared with the levels in control HSEM.Conclusion: The anti-melanogenic agent,PF3758309,has no skin irritation potential under the conditions used in this study. 展开更多
关键词 Human skin EQUIVALENT PF3758309 Irritation skin Anti-melanogenesis
下载PDF
Needle-free injection of insulin powder: delivery efficiency and skin irritation assessment 被引量:1
6
作者 Chun-yu LI Zhe-wei WANG +11 位作者 Can TU Jia-bo WANG Bing-qian JIANG Qi LI Ling-na ZENG Zhi-jie MA Ping ZHANG Yan-ling ZHAO Ya-ming ZHANG Dan YAN Rui TAN Xiao-he XIAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2014年第10期888-899,共12页
Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection(PNI... Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection(PNI) device with an automatic mechanical unit was designed. Its efficiency in delivering insulin was evaluated in alloxan-induced diabetic rabbits. The skin irritation caused by the device was investigated and the results were analyzed in relation to aerodynamic parameters. Inorganic salt-carried insulin powders had hypoglycemic effects, while raw insulin powders were not effective when delivered by PNI, indicating that salt carriers play an important role in the delivery of insulin via PNI. The relative delivery efficiency of phosphate-carried insulin powder using the PNI device was 72.25%. A safety assessment test showed that three key factors(gas pressure, cylinder volume, and nozzle distance) were related to the amount of skin irritation caused by the PNI device. Optimized injection conditions caused minimal skin lesions and are safe to use in practice. The results suggest that PNI has promising prospects as a novel technology for delivering insulin and other biological drugs. 展开更多
关键词 Powder needleless injection INSULIN Transdermal drug delivery skin irritation
原文传递
Development and application of a novel method to assess exposure levels of sensitizing and irritating substances leaching from menstrual hygiene products
7
作者 Q.Marcelis A.Gatzios +3 位作者 E.Deconinck V.Rogiers T.Vanhaecke B.Desmedt 《Emerging Contaminants》 2021年第1期116-123,共8页
Menstrual hygiene products(MHPs)like tampons,sanitary towels and panty liners are widely used by women and come in close contact with the intimate parts of the human body,which consist of mucosae that lack the importa... Menstrual hygiene products(MHPs)like tampons,sanitary towels and panty liners are widely used by women and come in close contact with the intimate parts of the human body,which consist of mucosae that lack the important barrier function of normal skin.Hence,substances leaching from MHP can easily penetrate and become systemically available.This study aims to develop a new in chemico methodology that allows to identify and measure realistic consumer exposure levels of several skin sensitizers and irritants leaching from MHPs under simulated use conditions.To assess the leaching of chemicals from MHPs,a menstrual fluid simulant(MFS)simulating pH,osmolarity and protein binding was first established.Subsequently,an analytical methodology was developed for nine well-known skin sensitizers and skin irritants.In short,the MFS samples underwent salting-out assisted liquid-liquid extraction before ultra-high performance liquid chromatography coupled with a triple-quadrupole mass spectrometry analysis.Validation was performed according to the total error approach with acceptability limits of±15%regarding the total analytical error(including systematic and random bias).Fifteen commercially available MHPs were assessed.Six products were found to leach at least one of the following five sensitizing and irritating compounds:a-isomethyl ionone,benzyl salicylate,hexyl cinnamaldehyde,linalool and piperonal.Piperonal was the most abundant compound leaching from the MHPs,with leaching concentration levels measured to 28.22 mg/g.In addition,the leaching level of benzyl salicylate was found to be 11.03 mg/g.The latter fragrance concentration is above 10 mg/g and would trigger mandatory labelling if the Cosmetic Regulation would apply for MHPs.However,none of the identified and quantified skin sensitizers were mentioned on the packaging.In conclusion,this novel methodology makes it possible to estimate realistic human exposure levels to skin sensitizers and irritants through the use of MHPs.Availability of these exposure estimates is vital to carry out a quantitative health risk assessment of these substances. 展开更多
关键词 Consumer product safety Menstrual hygiene products FRAGRANCE skin sensitization skin irritation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部