A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described ...A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate,reagent concentration,length of reaction coil,eluent acidity,etc. were optimized. In the buffer solution of NH3. H2O/NH4Cl at pH 4. 6,Al,Cr,Cu,Fe, Pb, V and Zn can be preconcentrated and then eluted with 4. 5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8. 1 ̄12. 6 with detection limits of μg/m level ,and the RSD with metals at μg/g level were 2. 3 ̄5. 0% (n= 7). The method proposed can reduce the matrix interference effectively , and has been applied to the determination of non-rare earth metals atμg/g level in high purity Eu2O3 with satisfactory results.展开更多
A novel and selective method for the fast determination of trace amounts of chromium species in water samples has been developed. The procedure is based on the selective formation of chromium diethyldithiocarbamate co...A novel and selective method for the fast determination of trace amounts of chromium species in water samples has been developed. The procedure is based on the selective formation of chromium diethyldithiocarbamate complexes at different pH in the presence of Mn(Ⅱ) as an enhancement agent of chromium signals followed by elution with organic eluents and determination by atomic flame absorption spectrometry. The maximum capacity of the employed disks was found to be (396±3) pg and (376±2) pg for Cr(Ⅲ) and Cr(Ⅵ), respectively. The detection limit of the proposed method is 49 and 43 ng·L^-1 for Cr(Ⅲ) and Cr(Ⅵ), respectively. The proposed method was successfully applied for determination of chromium species Cr(Ⅲ) and Cr(Ⅵ) in different water samples.展开更多
文摘A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate,reagent concentration,length of reaction coil,eluent acidity,etc. were optimized. In the buffer solution of NH3. H2O/NH4Cl at pH 4. 6,Al,Cr,Cu,Fe, Pb, V and Zn can be preconcentrated and then eluted with 4. 5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8. 1 ̄12. 6 with detection limits of μg/m level ,and the RSD with metals at μg/g level were 2. 3 ̄5. 0% (n= 7). The method proposed can reduce the matrix interference effectively , and has been applied to the determination of non-rare earth metals atμg/g level in high purity Eu2O3 with satisfactory results.
文摘A novel and selective method for the fast determination of trace amounts of chromium species in water samples has been developed. The procedure is based on the selective formation of chromium diethyldithiocarbamate complexes at different pH in the presence of Mn(Ⅱ) as an enhancement agent of chromium signals followed by elution with organic eluents and determination by atomic flame absorption spectrometry. The maximum capacity of the employed disks was found to be (396±3) pg and (376±2) pg for Cr(Ⅲ) and Cr(Ⅵ), respectively. The detection limit of the proposed method is 49 and 43 ng·L^-1 for Cr(Ⅲ) and Cr(Ⅵ), respectively. The proposed method was successfully applied for determination of chromium species Cr(Ⅲ) and Cr(Ⅵ) in different water samples.