In this bench scale submerged membrane bioreactor, effect of solid retention time and hydraulic retention time on membrane fouling propensity has been studied. This experiment is carried out at different solid retenti...In this bench scale submerged membrane bioreactor, effect of solid retention time and hydraulic retention time on membrane fouling propensity has been studied. This experiment is carried out at different solid retention time of 5, 10, 30, 70 and 98 days; and fouling behavior of membrane bioreactor is investigated. Average effluent quality is found to be 88.14%-94.38%. The experiment with different hydraulic retention is carried for 3 to 4 days and fouling behavior has been investigated. The effluent quality at different hydraulic retention time of 1, 2, 3, 5, 10 and 24 hours has been investigated. This paper aims to search optimal values of solid and hydraulic retention times at which lower fouling and higher organic removal efficiency can be obtained. This study has been mainly focused on operating parameters rather than microbial structure, effect and analysis of activated sludge to membrane fouling.展开更多
The steel company SSAB in Oxel?sund, Sweden operates a coke-oven plant and has since a long time operated an activated sludge plant for treatment of effluent water. Along with more stringent requirements on discharge ...The steel company SSAB in Oxel?sund, Sweden operates a coke-oven plant and has since a long time operated an activated sludge plant for treatment of effluent water. Along with more stringent requirements on discharge quality, especially focusing on nitrogen compounds and a new consent value for total nitrogen discharge (< 30 ppm of total N) the company decided to operate a pilot plant facility to investigate two major issues: 1) To define the conditions and restrictions for nitrification of ammonia nitrogen in the water;2) To find out how efficiently a denitrification would perform. In order to find answers to these questions SSAB hired a pilot plant for testing. The test facility is based on a single sludge activated sludge reactor system for biological nutrient removal, with a reactor volume of 3.8 m3. After a test period of 5 months it was possible to draw reliable conclusions regarding the performance. The untreated wastewater has a high content of total nitrogen, around 240 ppm. The major nitrogen part is ammonia nitrogen, but an important fraction is found as thiocyanate nitrogen. The following main conclusions were drawn from the test operation: · It was found to be crucial that the solids retention time (SRT) was kept at a sufficiently high level. During the successful operation the SRT was in the range of 40 - 50 days;· It is desirable to have an equalization basin upstream the main biological reactor to meet short time peak loads, defined as both flow and pollution;· The major toxic risks for the biological process were high thiocyanate and ammonia concentrations in the raw wastewater;· The system showed however a good microbiological capacity to acclimatize to the prevailing conditions after the needed time;· The tests did not include an optimization of the oxygen supply with respect to nitrification;however it was evident that the oxygen level was sufficient to maintain a complete nitrification at normal operating conditions;· Once the nitrification was established it was also possible to reach a high degree of denitrification—as long as an external carbon source was applied;· It was found that both the cyanide nitrogen and especially the thiocyanate nitrogen were reduced by the process. The cyanide reduction is probably related both to precipitation by ferrous ions and biological transformation.展开更多
Millions of tons of waste activated sludge(WAS) produced from biological wastewater treatment processes cause severe adverse environmental consequences. A better understanding of WAS composition is thus very critica...Millions of tons of waste activated sludge(WAS) produced from biological wastewater treatment processes cause severe adverse environmental consequences. A better understanding of WAS composition is thus very critical for sustainable sludge management. In this work, the occurrence and distribution of several fundamental sludge constituents were explored in WAS samples from nine full-scale wastewater treatment plants(WWTPs) of Beijing, China. Among all the components investigated, active heterotrophic biomass was dominant in the samples(up to 9478 mg/L), followed by endogenous residues(6736 mg/L),extracellular polymeric substances(2088 mg/L), and intracellular storage products(464 mg/L)among others. Moreover, significant differences(p 〈 0.05) were observed in composition profiles of sludge samples among the studied WWTPs. To identify the potential parameters affecting the variable fractions of sludge components, wastewater source as well as design and operational parameters of WWTPs were studied using statistical methods. The findings indicated that the component fraction of sewage sludge depends more on wastewater treatment alternatives than on wastewater characteristics among other parameters. A principal component analysis was conducted, which further indicated that there was a greater proportion of residual inert biomass in the sludge produced by the combined system of the conventional anaerobic/anoxic/oxic process and a membrane bioreactor. Additionally, a much longer solids retention time was also found to influence the sludge composition and induce an increase in both endogenous inert residues and extracellular polymeric substances in the sludge.展开更多
文摘In this bench scale submerged membrane bioreactor, effect of solid retention time and hydraulic retention time on membrane fouling propensity has been studied. This experiment is carried out at different solid retention time of 5, 10, 30, 70 and 98 days; and fouling behavior of membrane bioreactor is investigated. Average effluent quality is found to be 88.14%-94.38%. The experiment with different hydraulic retention is carried for 3 to 4 days and fouling behavior has been investigated. The effluent quality at different hydraulic retention time of 1, 2, 3, 5, 10 and 24 hours has been investigated. This paper aims to search optimal values of solid and hydraulic retention times at which lower fouling and higher organic removal efficiency can be obtained. This study has been mainly focused on operating parameters rather than microbial structure, effect and analysis of activated sludge to membrane fouling.
文摘The steel company SSAB in Oxel?sund, Sweden operates a coke-oven plant and has since a long time operated an activated sludge plant for treatment of effluent water. Along with more stringent requirements on discharge quality, especially focusing on nitrogen compounds and a new consent value for total nitrogen discharge (< 30 ppm of total N) the company decided to operate a pilot plant facility to investigate two major issues: 1) To define the conditions and restrictions for nitrification of ammonia nitrogen in the water;2) To find out how efficiently a denitrification would perform. In order to find answers to these questions SSAB hired a pilot plant for testing. The test facility is based on a single sludge activated sludge reactor system for biological nutrient removal, with a reactor volume of 3.8 m3. After a test period of 5 months it was possible to draw reliable conclusions regarding the performance. The untreated wastewater has a high content of total nitrogen, around 240 ppm. The major nitrogen part is ammonia nitrogen, but an important fraction is found as thiocyanate nitrogen. The following main conclusions were drawn from the test operation: · It was found to be crucial that the solids retention time (SRT) was kept at a sufficiently high level. During the successful operation the SRT was in the range of 40 - 50 days;· It is desirable to have an equalization basin upstream the main biological reactor to meet short time peak loads, defined as both flow and pollution;· The major toxic risks for the biological process were high thiocyanate and ammonia concentrations in the raw wastewater;· The system showed however a good microbiological capacity to acclimatize to the prevailing conditions after the needed time;· The tests did not include an optimization of the oxygen supply with respect to nitrification;however it was evident that the oxygen level was sufficient to maintain a complete nitrification at normal operating conditions;· Once the nitrification was established it was also possible to reach a high degree of denitrification—as long as an external carbon source was applied;· It was found that both the cyanide nitrogen and especially the thiocyanate nitrogen were reduced by the process. The cyanide reduction is probably related both to precipitation by ferrous ions and biological transformation.
基金supported by the National Natural Science Foundation of China(Nos.51408589 and 51138009)State Key Joint Laboratory of Environment Simulation and Pollution Control of China(Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,No.14Z03ESPCR)Youth Innovation Promotion Association of the Chinese Academy of Sciences
文摘Millions of tons of waste activated sludge(WAS) produced from biological wastewater treatment processes cause severe adverse environmental consequences. A better understanding of WAS composition is thus very critical for sustainable sludge management. In this work, the occurrence and distribution of several fundamental sludge constituents were explored in WAS samples from nine full-scale wastewater treatment plants(WWTPs) of Beijing, China. Among all the components investigated, active heterotrophic biomass was dominant in the samples(up to 9478 mg/L), followed by endogenous residues(6736 mg/L),extracellular polymeric substances(2088 mg/L), and intracellular storage products(464 mg/L)among others. Moreover, significant differences(p 〈 0.05) were observed in composition profiles of sludge samples among the studied WWTPs. To identify the potential parameters affecting the variable fractions of sludge components, wastewater source as well as design and operational parameters of WWTPs were studied using statistical methods. The findings indicated that the component fraction of sewage sludge depends more on wastewater treatment alternatives than on wastewater characteristics among other parameters. A principal component analysis was conducted, which further indicated that there was a greater proportion of residual inert biomass in the sludge produced by the combined system of the conventional anaerobic/anoxic/oxic process and a membrane bioreactor. Additionally, a much longer solids retention time was also found to influence the sludge composition and induce an increase in both endogenous inert residues and extracellular polymeric substances in the sludge.