In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte...In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods.展开更多
文摘In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods.