Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this in...Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.展开更多
BACKGROUND Hepatitis C virus genotype 3a(HCV G3a)is highly prevalent in Pakistan.Due to the elevated cost of available Food and Drug Administration-approved drugs against HCV,medicinal natural products of potent antiv...BACKGROUND Hepatitis C virus genotype 3a(HCV G3a)is highly prevalent in Pakistan.Due to the elevated cost of available Food and Drug Administration-approved drugs against HCV,medicinal natural products of potent antiviral activity should be screened for the cost-effective treatment of the disease.Furthermore,from natural products,active compounds against vital HCV proteins like non-structural protein 3(NS3)protease could be identified to prevent viral proliferation in the host.AIM To develop cost-effective HCV genotype 3a NS3 protease inhibitors from citrus fruit extracts.METHODS Full-length NS3 without co-factor non-structural protein 4A(NS4A)and codon optimized NS3 protease in fusion with NS4A were expressed in Escherichia coli.The expressed protein was purified by metal ion affinity chromatography and gel filtration.Citrus fruit extracts were screened using fluorescence resonance energy transfer(FRET)assay against the protease and polyphenols were identified as potential inhibitors using electrospray ionization-mass spectrometry(MS)/MS technique.Among different polyphenols,highly potent compounds were screened using molecular modeling approaches and consequently the most active compound was further evaluated against HCV NS4A-NS3 protease domain using FRET assay.RESULTS NS4A fused with NS3 protease domain gene was overexpressed and the purified protein yield was high in comparison to the lower yield of the full-length NS3 protein.Furthermore,in enzyme kinetic studies,NS4A fused with NS3 protease proved to be functionally active compared to full-length NS3.So it was concluded that co-factor NS4A fusion is essential for the purification of functionally active protease.FRET assay was developed and validated by the half maximal inhibitory concentration(IC50)values of commercially available inhibitors.Screening of citrus fruit extracts against the native purified fused NS4A-NS3 protease domain showed that the grapefruit mesocarp extract exhibits the highest percentage inhibition 91%of protease activity.Among the compounds identified by LCMS analysis,hesperidin showed strong binding affinity with the protease catalytic triad having S-score value of-10.98.CONCLUSION Fused NS4A-NS3 protease is functionally more active,which is effectively inhibited by hesperidin from the grapefruit mesocarp extract with an IC50 value of 23.32μmol/L.展开更多
Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the e...Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the ecological environment. The interaction between nano-TiO2 and bovine serum albumin (BSA) was studied by using TDFS and UV methods in this research.展开更多
The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectro...The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More展开更多
X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal...X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal coating on detection results were analyzed. The results show that the RSD of the method used to detect element content in the metal coating smeared on the waste plastics ranged from 0.008% to 0.044%; the determination range of the eight elements was 0.002%-52.0%,and their detection limit ranged from 0.0002% to 0.0008%. The determination results of X-ray fluorescence spectrometry were consistent with that of ICP-AES. The method can provide technical support for the determination of damage and pollution caused by metal coating smeared on waste plastics.展开更多
A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation...A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure.展开更多
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det...In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.展开更多
Globozoospermia is a severe form of teratozoospermia characterized by round-headed spermatozoa with an absent acrosome, an aberrant nuclear membrane and midpiece defects. Globozoospermia is diagnosed by the presence o...Globozoospermia is a severe form of teratozoospermia characterized by round-headed spermatozoa with an absent acrosome, an aberrant nuclear membrane and midpiece defects. Globozoospermia is diagnosed by the presence of 100% round-headed spermatozoa on semen analysis, and patients with this condition are absolutely infertile. The objective of this study was to investigate the differences in protein expression between human round- headed and normal spermatozoa. Two-dimensional (2-D) fluorescence difference gel electrophoresis (DIGE) coupled with mass spectrometry (MS) was used in this study. Over 61 protein spots were analysed in each paired normal/round-headed comparison, using DIGE technology along with an internal standard. In total, 35 protein spots identified by tandem mass spectrometry (MS/MS) exhibited significant changes (paired t-test, P 〈 0.05) in the expression level between normal and round-headed spermatozoa. A total of nine proteins were found to be upregulated and 26 proteins were found to be downregulated in round-headed spermatozoa compared with normal spermatozoa. The differentially expressed proteins that we identified may have important roles in a variety of cellular processes and structures, including spermatogenesis, cell skeleton, metabolism and spermatozoa motility.展开更多
Ion chromatography-ultra violet-hydride generation-Atomic Florescence Spectrometry was applied to detect 5 arsenic species in seafoods. The arsenic species studied include arsenobetaine(As B), arsenite(As(III)), dimet...Ion chromatography-ultra violet-hydride generation-Atomic Florescence Spectrometry was applied to detect 5 arsenic species in seafoods. The arsenic species studied include arsenobetaine(As B), arsenite(As(III)), dimethylarsinic acid(DMA), monomethylarsonic acid(MMA), and arsenate(As(V)), which were extracted from samples using 2% formic acid. Gradient elution using 33 mmol L^(-1) CH_3COONH_4 and 15 mmol L^(-1) Na_2CO_3 with 10 mL CH_3CH_2OH at pH 8.4 allowed the chromatographic separation of all the species on a Hamilton PRP-X100 anion-exchange column in less than 8 min. In this study, an ultrasound extraction method was used to extract arsenic species from seafood. The extraction efficiency was good and the recoveries from spiked samples were in the range of 72.6%–109%; the precision between sample replicates was higher than 3.6% for all determinations. The detection limits were 3.543 μg L^(-1) for As B, 0.4261 μg L^(-1) for As(III), 0.216 μg L^(-1) for DMA, 0.211 μg L^(-1) for MMA, and 0.709 μg L^(-1) for As(V), and the linear coefficients were greater than 0.999. We also developed an application of this method for the determination of arsenic species in bonito, Euphausia superba, and Enteromorpha with satisfactory results. Therefore, it was confirmed that this method was appropriate for the detection of arsenic species in seafood.展开更多
Polarization variable-angle synchronous fluorescence spectrometry was proposed to determine samples in turbid solution. A mixture of fluorescein, rhodamine 6G and rhodamine B was used to evaluate the technique. The ba...Polarization variable-angle synchronous fluorescence spectrometry was proposed to determine samples in turbid solution. A mixture of fluorescein, rhodamine 6G and rhodamine B was used to evaluate the technique. The background caused by scattering light was decreased remarkably. The limits of detection were 0.6 ng/ml for fluorescein, 2.3 ng/ml for rhodamine 6G and 4.1 ng/ml for rhodamine B, respectively.展开更多
In this paper the OH radicals produced by a needle-plate negative DC discharge in water vapor,N_(2)+H_(2)O mixture gas and He+H_(2)O mixture gas are investigated by a laser-induced fluorescence(LIF)system.With a balla...In this paper the OH radicals produced by a needle-plate negative DC discharge in water vapor,N_(2)+H_(2)O mixture gas and He+H_(2)O mixture gas are investigated by a laser-induced fluorescence(LIF)system.With a ballast resistor in the circuit,the discharge current is limited and the discharges remain in glow.The OH rotation temperature is obtained from fluorescence rotational branch fitting,and is about 350 K in pure water vapor.The effects of the discharge current and gas pressure on the production and quenching processes of OH radicals are investigated.The results show that in water vapor and He+H_(2)O mixture gas the fluorescence intensity of OH stays nearly constant with increasing discharge current,and in N_(2)+H_(2)O mixture gas the fluorescence intensity of OH increases with increasing discharge current.In water vapor and N_(2)+H_(2)O mixture gas the fluorescence intensity of OH decreases with increasing gas pressure in the studied pressure range,and in He+H_(2)O mixture gas the fluorescence intensity of OH shows a maximum value within the studied gas pressure range.The physicochemical reactions between electrons,radicals,ground and metastable molecules are discussed.The results in this work contribute to the optimization of plasma reactivity and the establishment of a molecule reaction dynamics model.展开更多
A rapid analysis method of determining content of eight compounds of open-hearth furnace slag was developed using X-ray fluorescence spectrometry and pressed powder briquettes. Matrix effect was corrected using theore...A rapid analysis method of determining content of eight compounds of open-hearth furnace slag was developed using X-ray fluorescence spectrometry and pressed powder briquettes. Matrix effect was corrected using theoretical alpha coefficient. Grains-size effect was eliminated by optimized sample preparation technique parameters. Mineral effect was corrected with standard curve of specially made standard samples. The analysis results of TiO2, TFe, SiO2, MgO, Al2O3, CaO, MnO and P2O5 in slag samples showed that both precision and accuracy are comparable with that of chemical method.展开更多
In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized ...In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized to determine the nephrotoxicity of these fractions with the help of fluorescence image analysis.As a result,the primary fraction A05 and its secondary fractions C06 "C09 and C12 "C14 were found to have significant toxicity to LLC-PK1 cell line,as determined by the survive rate less than 20% after they were treated with these fractions.These potential nephrotoxic fractions were further analyzed by multistage and high resolution mass spectrometry.The main compounds in these fractions were tentatively identified to be acetylshikonin,isobutyrylshikonin,β,β'-dimethyla-cryloylshikonin,and isovalerylshikonin,which may bring nephrotoxicity.展开更多
Retraction note:Khan M,Rauf W,Habib F,Rahman M,Iqbal M.Screening and identification of bioactive compounds from citrus against non-structural protein 3 protease of hepatitis C virus genotype 3a by fluorescence resonan...Retraction note:Khan M,Rauf W,Habib F,Rahman M,Iqbal M.Screening and identification of bioactive compounds from citrus against non-structural protein 3 protease of hepatitis C virus genotype 3a by fluorescence resonance energy transfer assay and mass spectrometry.World J Hepatol 2020;12(11):976-992 PMID:33312423 DOI:10.4254/wjh.v12.i11.976.The online version of the original article can be found at https://www.wjgnet.com/1948-5182/full/v12/i11/976.htm.展开更多
一个方法为 Na 的内容决心被开发, Mg ,艾尔, Si , P , S , Cl , K , Ca , Ti , V , Cr , Mn , Fe , Ni , Cu , Zn , Ga , Nb , Zr , Y , Sr , Rb , Ba ,在使用的海洋的沉积样品盖住 26 专业,未成年者,和踪...一个方法为 Na 的内容决心被开发, Mg ,艾尔, Si , P , S , Cl , K , Ca , Ti , V , Cr , Mn , Fe , Ni , Cu , Zn , Ga , Nb , Zr , Y , Sr , Rb , Ba ,在使用的海洋的沉积样品盖住 26 专业,未成年者,和踪迹元素的 La 和 Ce 等等由X光检查荧光 spectrometry 熔化了玻璃圆盘。刻度用海洋的沉积被成为证明引用材料和样品由在不同比例与流沉积和碳酸盐标准样品混合几海洋的沉积准备了的合成标准。矩阵效果用理论高山被改正哈象内部标准的系数,经验系数和散布放射(为踪迹元素) 。方法的精确性被证明参考材料 GBW07314, GBW07334 和 GSMS6 的分析评估。结果在与 RSD 的对标准的证明价值的好同意不到 2.60% 除了 Y,有 RSD 的 Cr, Ga, Ce, La, Nb, Rb,和 V 不到 9.0%(n=12 ) 。展开更多
A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g...A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%.展开更多
A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The methodis based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure ...A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The methodis based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and thenswept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atom-ization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected areas follows: reactive acidity, 20% HCl; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin-1; atomizing tempera-ture, 200 °C; negative high voltage, -300V; light current, 100 mA; integral time, 7s. The detection limit of the presentedmethod is 0.072 μg L-1 for selenium. The calibration curve shows a satisfactory line in the concentration range from 0.000 to1.000 μg L-1 Se. The recovery is 95.8%-102.2% .展开更多
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFF0701202)the National Natural Science Foundation of China(Grant No.11875087)。
文摘Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.
文摘BACKGROUND Hepatitis C virus genotype 3a(HCV G3a)is highly prevalent in Pakistan.Due to the elevated cost of available Food and Drug Administration-approved drugs against HCV,medicinal natural products of potent antiviral activity should be screened for the cost-effective treatment of the disease.Furthermore,from natural products,active compounds against vital HCV proteins like non-structural protein 3(NS3)protease could be identified to prevent viral proliferation in the host.AIM To develop cost-effective HCV genotype 3a NS3 protease inhibitors from citrus fruit extracts.METHODS Full-length NS3 without co-factor non-structural protein 4A(NS4A)and codon optimized NS3 protease in fusion with NS4A were expressed in Escherichia coli.The expressed protein was purified by metal ion affinity chromatography and gel filtration.Citrus fruit extracts were screened using fluorescence resonance energy transfer(FRET)assay against the protease and polyphenols were identified as potential inhibitors using electrospray ionization-mass spectrometry(MS)/MS technique.Among different polyphenols,highly potent compounds were screened using molecular modeling approaches and consequently the most active compound was further evaluated against HCV NS4A-NS3 protease domain using FRET assay.RESULTS NS4A fused with NS3 protease domain gene was overexpressed and the purified protein yield was high in comparison to the lower yield of the full-length NS3 protein.Furthermore,in enzyme kinetic studies,NS4A fused with NS3 protease proved to be functionally active compared to full-length NS3.So it was concluded that co-factor NS4A fusion is essential for the purification of functionally active protease.FRET assay was developed and validated by the half maximal inhibitory concentration(IC50)values of commercially available inhibitors.Screening of citrus fruit extracts against the native purified fused NS4A-NS3 protease domain showed that the grapefruit mesocarp extract exhibits the highest percentage inhibition 91%of protease activity.Among the compounds identified by LCMS analysis,hesperidin showed strong binding affinity with the protease catalytic triad having S-score value of-10.98.CONCLUSION Fused NS4A-NS3 protease is functionally more active,which is effectively inhibited by hesperidin from the grapefruit mesocarp extract with an IC50 value of 23.32μmol/L.
基金Suppoted by National Nature Science Foundation of China (Grant Nos. 41130746, 41272371)the Doctor Foundation of SWUST of China (Grant No. 11zx7139)
文摘Although scientific and policy bodies have stated that nanomaterials are not intrinsically toxic, there is interest in evaluating if and how many engineered nanomaterials may do harm to the health of mankind and the ecological environment. The interaction between nano-TiO2 and bovine serum albumin (BSA) was studied by using TDFS and UV methods in this research.
文摘The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More
基金Supported by Project of Ningbo Entry-Exit Inspection and Quarantine Bureau(K21-2013)
文摘X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal coating on detection results were analyzed. The results show that the RSD of the method used to detect element content in the metal coating smeared on the waste plastics ranged from 0.008% to 0.044%; the determination range of the eight elements was 0.002%-52.0%,and their detection limit ranged from 0.0002% to 0.0008%. The determination results of X-ray fluorescence spectrometry were consistent with that of ICP-AES. The method can provide technical support for the determination of damage and pollution caused by metal coating smeared on waste plastics.
文摘A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure.
文摘In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.
基金Acknowledgment We thank Beijing Proteome Research Center, (Beijing, China) for its enthusiastic technological support and for the theory of 2-D DIGE. We also thank(Changsha, China) College of Life Sciences at Hunan Normal University for supporting the MS technology. Finally, we are very grateful to our collaborators for their help, as well as their valuable discussions and suggestions during the course of this work. This work was supported by two grants from the National Natural Science Foundation of China (NO. 30170480 and NO. 30470884).
文摘Globozoospermia is a severe form of teratozoospermia characterized by round-headed spermatozoa with an absent acrosome, an aberrant nuclear membrane and midpiece defects. Globozoospermia is diagnosed by the presence of 100% round-headed spermatozoa on semen analysis, and patients with this condition are absolutely infertile. The objective of this study was to investigate the differences in protein expression between human round- headed and normal spermatozoa. Two-dimensional (2-D) fluorescence difference gel electrophoresis (DIGE) coupled with mass spectrometry (MS) was used in this study. Over 61 protein spots were analysed in each paired normal/round-headed comparison, using DIGE technology along with an internal standard. In total, 35 protein spots identified by tandem mass spectrometry (MS/MS) exhibited significant changes (paired t-test, P 〈 0.05) in the expression level between normal and round-headed spermatozoa. A total of nine proteins were found to be upregulated and 26 proteins were found to be downregulated in round-headed spermatozoa compared with normal spermatozoa. The differentially expressed proteins that we identified may have important roles in a variety of cellular processes and structures, including spermatogenesis, cell skeleton, metabolism and spermatozoa motility.
基金funded by the National Major ScientificInstrument and Equipment Development Project of China (No.2012YQ090229)
文摘Ion chromatography-ultra violet-hydride generation-Atomic Florescence Spectrometry was applied to detect 5 arsenic species in seafoods. The arsenic species studied include arsenobetaine(As B), arsenite(As(III)), dimethylarsinic acid(DMA), monomethylarsonic acid(MMA), and arsenate(As(V)), which were extracted from samples using 2% formic acid. Gradient elution using 33 mmol L^(-1) CH_3COONH_4 and 15 mmol L^(-1) Na_2CO_3 with 10 mL CH_3CH_2OH at pH 8.4 allowed the chromatographic separation of all the species on a Hamilton PRP-X100 anion-exchange column in less than 8 min. In this study, an ultrasound extraction method was used to extract arsenic species from seafood. The extraction efficiency was good and the recoveries from spiked samples were in the range of 72.6%–109%; the precision between sample replicates was higher than 3.6% for all determinations. The detection limits were 3.543 μg L^(-1) for As B, 0.4261 μg L^(-1) for As(III), 0.216 μg L^(-1) for DMA, 0.211 μg L^(-1) for MMA, and 0.709 μg L^(-1) for As(V), and the linear coefficients were greater than 0.999. We also developed an application of this method for the determination of arsenic species in bonito, Euphausia superba, and Enteromorpha with satisfactory results. Therefore, it was confirmed that this method was appropriate for the detection of arsenic species in seafood.
文摘Polarization variable-angle synchronous fluorescence spectrometry was proposed to determine samples in turbid solution. A mixture of fluorescein, rhodamine 6G and rhodamine B was used to evaluate the technique. The background caused by scattering light was decreased remarkably. The limits of detection were 0.6 ng/ml for fluorescein, 2.3 ng/ml for rhodamine 6G and 4.1 ng/ml for rhodamine B, respectively.
基金supported by National Natural Science Foundation of China(No.51777091)Innovative Talents Team Project of‘Six Talent Peaks’of Jiangsu Province(No.TDJNHB-006)Postgraduate Research&Practice Innovation Program of Jiangsu Province in China(No.SJCX20_0345)。
文摘In this paper the OH radicals produced by a needle-plate negative DC discharge in water vapor,N_(2)+H_(2)O mixture gas and He+H_(2)O mixture gas are investigated by a laser-induced fluorescence(LIF)system.With a ballast resistor in the circuit,the discharge current is limited and the discharges remain in glow.The OH rotation temperature is obtained from fluorescence rotational branch fitting,and is about 350 K in pure water vapor.The effects of the discharge current and gas pressure on the production and quenching processes of OH radicals are investigated.The results show that in water vapor and He+H_(2)O mixture gas the fluorescence intensity of OH stays nearly constant with increasing discharge current,and in N_(2)+H_(2)O mixture gas the fluorescence intensity of OH increases with increasing discharge current.In water vapor and N_(2)+H_(2)O mixture gas the fluorescence intensity of OH decreases with increasing gas pressure in the studied pressure range,and in He+H_(2)O mixture gas the fluorescence intensity of OH shows a maximum value within the studied gas pressure range.The physicochemical reactions between electrons,radicals,ground and metastable molecules are discussed.The results in this work contribute to the optimization of plasma reactivity and the establishment of a molecule reaction dynamics model.
文摘A rapid analysis method of determining content of eight compounds of open-hearth furnace slag was developed using X-ray fluorescence spectrometry and pressed powder briquettes. Matrix effect was corrected using theoretical alpha coefficient. Grains-size effect was eliminated by optimized sample preparation technique parameters. Mineral effect was corrected with standard curve of specially made standard samples. The analysis results of TiO2, TFe, SiO2, MgO, Al2O3, CaO, MnO and P2O5 in slag samples showed that both precision and accuracy are comparable with that of chemical method.
基金Supported by the National Key Scientific and Technological Project of China(No.2009ZX09502-012)the Research Fund for the Doctoral Program of Higher Education of China(No.20090101110126)the Zhejiang Province Science and Technology Plan Project,China(No.2008C23065)
文摘In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized to determine the nephrotoxicity of these fractions with the help of fluorescence image analysis.As a result,the primary fraction A05 and its secondary fractions C06 "C09 and C12 "C14 were found to have significant toxicity to LLC-PK1 cell line,as determined by the survive rate less than 20% after they were treated with these fractions.These potential nephrotoxic fractions were further analyzed by multistage and high resolution mass spectrometry.The main compounds in these fractions were tentatively identified to be acetylshikonin,isobutyrylshikonin,β,β'-dimethyla-cryloylshikonin,and isovalerylshikonin,which may bring nephrotoxicity.
文摘Retraction note:Khan M,Rauf W,Habib F,Rahman M,Iqbal M.Screening and identification of bioactive compounds from citrus against non-structural protein 3 protease of hepatitis C virus genotype 3a by fluorescence resonance energy transfer assay and mass spectrometry.World J Hepatol 2020;12(11):976-992 PMID:33312423 DOI:10.4254/wjh.v12.i11.976.The online version of the original article can be found at https://www.wjgnet.com/1948-5182/full/v12/i11/976.htm.
基金Supported by China Ministry of Science and Technology (2000DEB20081)China Ocean Mineral Resources R&D Association (COMRA) (No.DY105-05-01-05)+1 种基金China Ministry of Education(No.205089)China National Natural Science Foundation (No.40076015)
文摘一个方法为 Na 的内容决心被开发, Mg ,艾尔, Si , P , S , Cl , K , Ca , Ti , V , Cr , Mn , Fe , Ni , Cu , Zn , Ga , Nb , Zr , Y , Sr , Rb , Ba ,在使用的海洋的沉积样品盖住 26 专业,未成年者,和踪迹元素的 La 和 Ce 等等由X光检查荧光 spectrometry 熔化了玻璃圆盘。刻度用海洋的沉积被成为证明引用材料和样品由在不同比例与流沉积和碳酸盐标准样品混合几海洋的沉积准备了的合成标准。矩阵效果用理论高山被改正哈象内部标准的系数,经验系数和散布放射(为踪迹元素) 。方法的精确性被证明参考材料 GBW07314, GBW07334 和 GSMS6 的分析评估。结果在与 RSD 的对标准的证明价值的好同意不到 2.60% 除了 Y,有 RSD 的 Cr, Ga, Ce, La, Nb, Rb,和 V 不到 9.0%(n=12 ) 。
基金supported by the Key Science and Technology pnasp Minsty of Educaton umder contr act(N0.200010-0079).
文摘A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%.
文摘A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The methodis based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and thenswept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atom-ization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected areas follows: reactive acidity, 20% HCl; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin-1; atomizing tempera-ture, 200 °C; negative high voltage, -300V; light current, 100 mA; integral time, 7s. The detection limit of the presentedmethod is 0.072 μg L-1 for selenium. The calibration curve shows a satisfactory line in the concentration range from 0.000 to1.000 μg L-1 Se. The recovery is 95.8%-102.2% .